0% found this document useful (0 votes)
63 views

EXPERIMENT5

This document outlines an experiment to determine the coefficient of discharge, velocity, and contraction for flow through an orifice using a hydraulics bench. The experiment involves measuring flow rates at different head heights and calculating coefficients based on Bernoulli's equation and measurements of orifice diameter, vena contracta diameter, and Pitot tube readings. Students are to perform the experiment, record measurements, calculate coefficients, and answer questions about the assumptions and reliability of the coefficient values.

Uploaded by

Chanel Ann
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views

EXPERIMENT5

This document outlines an experiment to determine the coefficient of discharge, velocity, and contraction for flow through an orifice using a hydraulics bench. The experiment involves measuring flow rates at different head heights and calculating coefficients based on Bernoulli's equation and measurements of orifice diameter, vena contracta diameter, and Pitot tube readings. Students are to perform the experiment, record measurements, calculate coefficients, and answer questions about the assumptions and reliability of the coefficient values.

Uploaded by

Chanel Ann
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

HYDRAULICS DEPARTMENT

Name:_______________________________
Subject & Section:______________________ Date Performed:________________
Instructor:____________________________ Date Submitted:________________

EXPERIMENT NO. 5

FLOW THROUGH AN ORIFICE

OBJECTIVE:

To determine the coefficient of discharge, velocity, and contraction of a small orifice.

EQUIPMENT:

Hydraulics Bench
Flow Through an Orifice Apparatus
Stopwatch

25
DERIVATION:

From the application of Bernoulli’s Equation (conservation of mechanical


energy for a steady, incompressible frictionless flow) :
The ideal orifice outflow velocity at the jet vena contracta (narrowest diameter) is

vi = (2gh)1/2

where h is the height of fluid above the orifice.

The actual velocity is

v = Cv(2gh)1/2 ------------------(1)

Cv is the coefficient of velocity, which allows for the effects of viscosity and,
therefore Cv <1

For the Pitot tube hc = v2/2g ; ie. vi = (2ghc)1/2

Hence Cv = ( hc / ho )1/2

The actual flow rate of the jet is defined as :

Qt = Acv

where Ac is the cross- sectional area of the vena contracta, given by :

Ac = Cc A o Cc = ( Ac / Ao ) = ( dc2/ do2 )

where

Ao is the orifice area and Cc is the coefficient of contraction and, therefore, Cc< 1

Hence

Q t = Ao Cc Cv(2gh)1/2

The product Cc Cv is called the discharge coefficient, Cd, so finally

Q t = Ao Cd (2gh)1/2

If Cd is assumed to be constant, then a graph of Qt plotted against ( h )1/2 will be


linear and the slope, S = CdAo ( 2g )1/2

26
PROCEDURE:

(EQUIPMENT SET-UP)

1. Position the apparatus across the channel on top of the hydraulic bench and
level it using the adjustable feet and the spirit level on the base. Connect the
flexible inlet pipe to the hydraulic bench snap connector in the top channel.
Place the end of the overflow tube directly into the hydraulics bench overflow
(located in the side wall of the volumetric tank), and adjust the inlet pipe to
the approximate level of the head required for the experiment.

2. Remove the orifice plate from the recess in the cylinder base, by releasing
the two screws (take care not to lose the ‘O’ –ring seal). Check the orifice
profile.

3. Replace the required orifice. The sharp-edged orifice (if used) should be
installed with the sharp edge uppermost.

4. Turn on the pump and open the bench valve gradually. As the water level
rises in the reservoir towards the top of the overflow tube, adjust the bench
valve to give a water level of 2 to 3 mm above the overflow level, with the
end of the inlet tube fully submerged. This will ensure a constant head and
produce a steady flow through the orifice.

(TAKING A SET OF RESULTS)

In the first part of the experiment, adjust the overflow pipe and inlet pipe as
described above, to obtain a constant head height.

DETERMINATION OF THE COEFFICIENT OF DISCHARGE

To measure Cd, the discharge is obtained by collection of a known quantity of


water from the orifice in the volumetric tank, and recording the value of the
head ho on the orifice.

DETERMINATION OF THE COEFFICIENT OF VELOCITY

To measure Cv, the Pitot tube is inserted into the emerging jet close to the
underside of the tank, and the values of the Pitot head h c and head ho on the
orifice are noted.

27
DETERMINATION OF THE COEFFCIENT OF CONTRACTION (SHARP-EDGED
ORIFICE)

This should be done using the sharp-edged orifice, as there is likely to be


insufficient contraction to obtain a reliable value for the other orifices.

1. Measure Cc it is necessary to find the diameter of the jet at the vena


contracta. This is done by utilizing the fine wire attached to the head of
the Pitot tube, the plane of the wire being normal to the direction of
traverse of the tube. The wire is brought to each edge of the jet in turn,
just below the tank, and the position of the tube as read on the lead
screws and graduated nut read in each case. The difference of the
readings represents the diameter of the jet.

2. The second part of the experiment the inflow to the tank is reduced to
lower the level in the tank in stages, the discharge from the orifice being
measured at each stage. Care should be taken to allow the level to settle
to a steady value after the inflow to the tank has been changed, and it is
advisable to read this level several times while the discharge is being
collected and to record the mean value over the timed interval. About
eight different flow rates should be sufficient to establish the relationship
between discharge and head on the orifice.

APPLICATION OF PRINCIPLE:

1. Is it justifiable to assume that Cd is a constant over the range of steady flows


tested?
2. Why are the Cd values significantly less than 1.00?
3. Comparing Cd values for the steady and the falling head tests, which value is
likely to be more reliable?

28
FINAL DATA SHEET

NAME:_____________________________________________________ DATE: _______________________


SUBJECT & SECTION:_______________________________________ GROUP NO.___________________
SEAT NO. __________

EXPERIMENT NO.5

FLOW THROUGH AN ORIFICE

Vena Orifice Pitot Flow


Orifice Volume Time Coeff.
Contracta Head Head rate Coeff. Of Coeff of
Diameter Of
Diameter Discharge Contraction k
do V t Velocity
dc ho hc Qt (Cd) (Cc)
(m) (m3) (sec) (Ct)
(m) (m) (m) (m3/s)
1
2
3
4
5
6
7
8
9
10
11

29

You might also like