Location: Doc No: Client: Page No: PMC

This document discusses the design of foundation pilings for gas compressors and coolers. It provides machine data, soil parameters, foundation plans and elevations. It describes checking the foundations for factors like eccentricity, weight, frequency, amplitude, wind and seismic loads. Pile capacity is checked for each foundation. Annexures include load data and drawings from vendors as well as calculations of dynamic pile stiffness for two compressors.

Uploaded by

Neeraj Dubey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Location: Doc No: Client: Page No: PMC

This document discusses the design of foundation pilings for gas compressors and coolers. It provides machine data, soil parameters, foundation plans and elevations. It describes checking the foundations for factors like eccentricity, weight, frequency, amplitude, wind and seismic loads. Pile capacity is checked for each foundation. Annexures include load data and drawings from vendors as well as calculations of dynamic pile stiffness for two compressors.

Uploaded by

Neeraj Dubey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Location: GNAQ

Doc No:
CLIENT:
Page No:
PMC:
7.5 CHECK FOR PILING LOADS .......................................................................................... 45
7.6 STAAD OUTPUT .............................................................................................................. 46
8. DESIGN OF MP GAS COMPRESSOR (611-K-104A) FOUNDATION PILING................................. 52
8.1 DESIGN PHILOSOPHY FOR COMPRESSOR FOUNDATIONS .................................... 52
8.2 MACHINE DATA .............................................................................................................. 52
8.3 SOIL PARAMETERS FOR DESIGN ................................................................................ 55
8.4 FOUNDATION PLAN & ELEVATION .............................................................................. 56
8.5 GEOMETRY OF FOUNDATION ...................................................................................... 59
8.6 CHECK FOR ECCENTRICITY ......................................................................................... 60
8.7 CHECK FOR FOUNDATION WEIGHT ............................................................................ 60
8.8 CHECK FOR FREQUENCY ............................................................................................. 61
8.9 CHECK FOR AMPLITUDE............................................................................................... 64
8.10 DYNAMIC FORCES AND MOMENT ............................................................................... 68
8.11 CHECK FOR AMPLITUDE (ENGINE) ............................................................................. 69
8.12 WIND LOAD CALCULATION .......................................................................................... 77
8.13 SEISMIC LOAD CALCULATION ..................................................................................... 77
8.14 PILE CAPACITY CHECK ................................................................................................. 78
9. DESIGN OF COOLER (611-E-104A) FOUNDATION PILING .......................................................... 82
9.1 DESCRIPTION.................................................................................................................. 82
9.2 LOADING DATA............................................................................................................... 82
9.3 ANALYSIS CONCEPT ..................................................................................................... 83
9.4 STAAD DIAGRAMS ......................................................................................................... 84
9.5 CHECK FOR PILING LOADS .......................................................................................... 85
9.6 STAAD OUTPUT .............................................................................................................. 86
ANNEXURE-1 LP GAS COMPRESSOR ENGINE DRIVEN (611-K-101A) GA DRAWING AND LOAD DATA FROM VENDOR
ANNEXURE-2 COOLER (611-E-101A) GA DRAWING AND LOAD DATA FROM VENDOR
ANNEXURE-3 MP GAS COMPRESSOR ENGINE DRIVEN (611-K-104A) GA DRAWING AND LOAD DATA FROM VENDOR
ANNEXURE-4 COOLER (611-E-104A) GA DRAWING AND LOAD DATA FROM VENDOR
ANNEXURE-5 CALCULATION OF DYNAMIC STIFFNESS OF PILE FOR COMPRESSOR 611-K- 101A
ANNEXURE-6 CALCULATION OF DYNAMIC STIFFNESS OF PILE FOR COMPRESSOR 611-K-
104A
GCPA-611-CV-CL-GCC-A-08 (Rev 1)

Page 3 of 91
M/s PDIL
.......................................... 45
.......................................... 46
DATION PILING................................. 52
NS .................................... 52
.......................................... 52
.......................................... 55
.......................................... 56
.......................................... 59
.......................................... 60
.......................................... 60
.......................................... 61
......................................... 64
.......................................... 68
.......................................... 69
.......................................... 77
.......................................... 77
.......................................... 78
G .......................................................... 82
......................................... 82
......................................... 82
.......................................... 83
.......................................... 84
.......................................... 85
.......................................... 86
101A) GA DRAWING AND LOAD DATA FROM VENDOR
DATA FROM VENDOR
-104A) GA DRAWING AND LOAD DATA FROM VENDOR
DATA FROM VENDOR
E FOR COMPRESSOR 611-K- 101A
E FOR COMPRESSOR 611-K-