Installation & Operation LCD Display

1. The document provides installation and operation instructions for a line-interactive UPS model iFP 600VA-2KVA. 2. It describes how to inspect the UPS, connect it to a power source, plug in equipment, and turn the UPS on and off. 3. The rear panel diagram shows outlet and port locations, and troubleshooting tips are provided for issues like no display, always on battery mode, or continuous beeping.

Uploaded by

Bashar Mohammad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views

Installation & Operation LCD Display

1. The document provides installation and operation instructions for a line-interactive UPS model iFP 600VA-2KVA. 2. It describes how to inspect the UPS, connect it to a power source, plug in equipment, and turn the UPS on and off. 3. The rear panel diagram shows outlet and port locations, and troubleshooting tips are provided for issues like no display, always on battery mode, or continuous beeping.

Uploaded by

Bashar Mohammad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Line-interactive UPS

FSP Manual Guide iFP 600VA~2KVA

Installation & Operation LCD Display


Operation Display
 Inspection UPS LCD Description
• The following items are inside the box: mode
UPS When UPS is powered on, it
●UPS unit & User manual
Power will enter this mode for 4
• Remove the UPS from its package and inspect it for damage that on seconds.
may have occurred during shipping. If any damage is discovered,
AC Mode LCD information will be
re-pack the unit and return it to the place of purchase. displayed in the following
order when LCD is touched.
 Connect to Utility Power 1.Output voltage
• Connect AC power cord to utility power. Then, the UPS will start 2.Input voltage
3.Load level
to charge inside battery. For best result, charge the battery for 6
4.Battery capacity
hours prior to initial use. When AVR is functioning,
icon will flash every
second.
 Plug in Equipment Overload When overload occurs,
• Plug your equipment to Battery Backup Outlets on the rear panel in AC alarm will beep every 0.5
of the UPS. mode icon will flash. second.
• NOTE: Make sure that the UPS is powered on to protect all
important devices from data loss during power failure. Battery Alarm will beep every 10
Mode seconds and LCD
• CAUTION: NEVER connect a laser printer or scanner to the
information will be displayed
battery backup outlets of UPS. The equipment may draw in the following order when
significantly power to overload the UPS. LCD is touched.
1.Output voltage
 Turn On/Off the UPS 2.Input voltage
When battery level is low,
3.Load level
• Please transport the UPS system only in the original package to icon will flash.
4.Battery capacity
protect against shock and impact. Overload When overload occurs,
in battery alarm will beep every 0.5
Rear Panel mode icon will flash. second.

NOTE: If backlight shuts off, you may activate it by touching the screen.

Fault Code Table:


Fault condition LCD Solutions
Output short Disconnect short-circuited loads and
circuited restart the UPS again.

400-800VA Overload fault Disconnect all output loads and


restart the UPS again.

Overcharge Call for service immediately.

Bad/severely Please replace the battery.


discharged
battery
High output Call for service immediately.
1000VA voltage fault

Over- Call for service immediately.


temperature

If fault alarm occurs, please call for service immediately.

1500-2000VA

A: Outlets
B: AC input
C: Fuse/Breaker
D: USB port
E: Surge protection
Line-interactive UPS
FSP Manual Guide iFP 600VA~2KVA

Safety caution Troubleshooting


• This UPS utilizes voltage that may be hazardous. Do not attempt Problem Possible Cause Solutions
Nothing is The UPS is not Press the power switch again to
to disassemble the unit. The unit contains no user replaceable
displayed on on. turn on the UPS.
parts. Only factory service personnel may perform repairs. LCD panel. Battery voltage Charge the battery at least 6
• This pluggable type A equipment with battery already installed by is too low. hours.
the supplier is operator installable and may be operated by Battery fault. Replace the battery.
laymen.
The UPS Power cord Re-plug the power cord.
• The mains socket outlet that supplies the UPS shall be installed always on loose.
near the UPS and shall be easily accessible. battery mode.
• During the installation of this equipment it should be assured that The UPS Please check Please check the fault code for
the sum of the leakage currents of the UPS and the connected continuously the fault code the details.
loads does not exceed 3.5mA. beeps. for the details.
Backup time Battery voltage Charge the battery at least 6
• Connection to any other type of receptacle other than a two-pole,
too short. is too low. hours.
three-wire grounded receptacle may result in shock hazard as Overload. Remove some unnecessary
well as violate local electrical codes. loads. Before reconnecting
• In the event of an emergency, press the "OFF" button and equipment, please verify that the
disconnect the power cord from the AC power supply to properly load matches the UPS capability
specified in the specs.
disable the UPS.
Battery defect. Replace the battery.
• Do not allow any liquids or any foreign object to enter the UPS.
• Do not place beverages or any other liquid-containing vessels on
or near the unit. Specification
• This unit intended for installation in a controlled environment 600VA/800VA
(temperature controlled, indoor area free of conductive Model iFP 600 iFP 800
Capacity 600VA/ 800VA/
contaminants). Avoid installing the UPS in locations where there
360W 480W
is standing or running water, or excessive humidity.
Input voltage 220/230/240 Vac
• Do not plug the UPS input into its own output. Input Voltage 140-290 Vac
• Do not attach a power strip or surge suppressor to the UPS. Range
• Do not attach non-computer-related items, such as medical Output Voltage ± 10%(bat mode)
equipment, life-support equipment, microwave ovens, or vacuum Regulation
Transfer Time Typical 2-6 ms
cleaners to UPS.
Waveform Simulated Sinewave
• Do not dispose of batteries in a fire as they may explode.
Battery Type 12V/7Ah 12V/9Ah
• Internal battery voltage is 12VDC.Sealed, lead -acid, 6-cell battery. Battery Number 1 1
• A battery can present a risk of electrical shock and high sh ort Charging Time 4 hours recover to 90% capacity
circuit current. The following precautions should be observed Dimension(mm) 300 x 101 x 142
when working on batteries: Net Weight (kgs) 4.25 4.9
1) Remove watches, rings, or other metal objects from the hands. Humidity 0-90% RH @ 0-40°C non-condensing)
Noise Level Less than 40dB
2) Use tools with insulated handles.
*Specifications are subject to change without notice.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries. 1000VA/1500VA/2000VA
5) Disconnect charging source prior to connecting or Model iFP 1000 iFP 1500 iFP 2000
disconnecting batteries terminal. Capacity 1000VA/ 1500VA/ 2000VA/
• Servicing of batteries should be performed or supervised by 600W 900W 1200W
personnel knowledgeable of batteries and the required Input voltage 220/230/240 Vac
precautions. Keep unauthorized personnel away from batteries. Input Voltage 140-290 Vac
Range
• When replacing batteries, replace with the same number and type
Output Voltage ± 10%(bat mode)
of sealed lead-acid battery. Regulation
• Do not open or mutilate the battery or batteries. Release Transfer Time Typical 2-6 ms
electrolyte is harmful to the skin and eyes. It may be toxic. Waveform Simulated Sinewave
• Attention, hazardous through electric shock. Also with dis - Battery Type 12V/7Ah 12V/9Ah 12V/9Ah
connection of this unit from the mains, hazardous voltage still may Battery Number 2 2 2
Charging Time 4-6 hours recover to 90% capacity
be accessible through supply from battery. The battery supply
Dimension(mm) 320 x 130 x 182
should be therefore disconnected in the plus and minus pole at
Net Weight (kgs) 8.2 10.4 11
the connectors of the battery when maintenance or service work Humidity 0-90% RH @ 0-40°C non-condensing)
inside the UPS is necessary. Noise Level Less than 40dB
• To reduce the risk of overheating the UPS, do not cover the UPS' *Specifications are subject to change without notice.
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space
heater or furnaces.
• Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.