0% found this document useful (0 votes)
225 views7 pages

UT312 English Manual

This document provides instructions for operating the UT312 vibration meter. It includes: 1) An introduction describing the meter's functions for measuring vibration displacement, speed, and acceleration of mechanical equipment. 2) Instructions on unpacking the meter and its components, and safety notices for proper use. 3) A description of the meter's components including the sensor, display, buttons, and switch. 4) Steps for setup and operation including installing batteries, selecting the measurement mode, taking measurements, and technical specifications.

Uploaded by

leivaj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
225 views7 pages

UT312 English Manual

This document provides instructions for operating the UT312 vibration meter. It includes: 1) An introduction describing the meter's functions for measuring vibration displacement, speed, and acceleration of mechanical equipment. 2) Instructions on unpacking the meter and its components, and safety notices for proper use. 3) A description of the meter's components including the sensor, display, buttons, and switch. 4) Steps for setup and operation including installing batteries, selecting the measurement mode, taking measurements, and technical specifications.

Uploaded by

leivaj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

P/N:110401103773X

DATE:2018.06.26
REV.2
CONTENTS

I. Introduction to UT312 Product----------------------------------------------------------------------------1


II. Unpacking Inspection---------------------------------------------------------------------------------------2
III. Safety Notices------------------------------------------------------------------------------------------------ 2
IV. Instrument Structure----------------------------------------------------------------------------------------3
V. Instrument Setup and Operation-------------------------------------------------------------------------4
VI. Technical Indicators-----------------------------------------------------------------------------------------6
VII. Maintenance--------------------------------------------------------------------------------------------------7
I.INTRODUCTION TO UT312 PRODUCT II.UNPACKING INSPECTION
UT-312 vibration meter is a split portable vibration measurer which consists of acceleration Please unpack and check if following items are deficient or damaged or not. Please contact
sensor and digital measurement display circuit. It is mainly used to measure vibration the nearest sales service agent of our company if there is any deficiency or damage.
displacement, speed (or intensity) and acceleration of mechanical equipment. Current status 1. Host--------------------------------------------------------------------1set
(such as excellence, notice or danger) can be determined for equipment (such as fan, pump, 2. Sensor (with magnetic base)------------------------------------1 (standard) pcs assembled to host
compressor and motor, etc) by above measuring data according to enterprise & machine 3. Signal wire of sensor----------------------------------------------1 (standard) wire assembled to host
standards by comparing with national metrological verification regulations of JJG 676-2000 4. Hanging rope--------------------------------------------------------1 (standard) wire assembled to host
working vibration meter. 5. 9V battery------------------------------------------------------------1 section
Such instrument has measuring value locking, low-voltage prompt and automatic shutdown 6. Manual----------------------------------------------------------------1 book
functions. With advantages such as wide measurement scope, simple operation and 7. Certificate-------------------------------------------------------------1 sheet
convenient carrying, it can be used for patrol detection of equipment vibration in power,
metallurgic and petrochemical industries widely so it is an ideal tally instrument. III.SAFETY NOTICES
Working principle: Warning: Please pay attention to possible danger and conditions for user or damage
factors for vibration meter!
Acceleration sensor Please use vibration meter according to steps shown in the manual or it may be damaged.
Please abide by following guidelines to avoid instrument damage.
To check if shell is ruptured or lacks of plastic pieces or not before using vibration meter.
Integer I Adjustment I Please do not use vibration meter with damaged shell.
Wave filter AC/DC A/D LCD Please replace battery as soon as possible to avoid error of measuring data if battery symbol
of appears.
Please do not continue to use vibration meter which operates abnormally. Please send it to
Integer II Adjustment II fixed repair agent of our company for repair.
Please do not use vibration meter in wet environment with combustible and explosive gas.
Please do not detach shell of vibration meter to avoid damage. signal wire of sensor three-gear toggle switch
Please do not try to charge battery to avoid personal injury due to battery explosion. Please sensor shell
pay attention to + and - poles during battery installation.
Please pay attention to protect LCD of vibration meter to avoid scratch or crush. LCD measurement key

2. Symbol (shown in Figure 2 and Form 2)


IV.INSTRUMENT STRUCTURE
1. Instrument structure (shown in Figure 1 and Form 1) 1. Vibration acceleration
2. Vibration speed
1.Signal wire of sensor 2.Sensor
3. Vibration displacement

Vibration acceleration
4.Three-gear toggle switch
3. LCD Vibration speed
Vibration displacement
3. Key instructions (shown in Figure 1)
The 5 element shown in Figure 1: Measurement key button

V.INSTRUMENT SETUP AND OPERATION


6.Measurement key 5.Shell
1.Battery installation
Please open cell box on the instrument back and then install 6F22 type 9V laminated cell into
cell box. Please pay attention to polarity then cover it.
2.Power Inspection VI.TECHNICAL INDICATORS
Please press measurement key and observe display. Battery replacement mark in the left end
1. General Specification
of display shows low battery voltage and prompt of battery replacement. No mark refers to
normal voltage for measurement. (Machine will power off automatically 1 minute after LCD display: 3 1/2-bit display; The maximum display: 1999
loosening the key.) Under-voltage display:
3.Selection of measurement mode Sensor type: Acceleration sensor
Please toggle measurement selection switch of vibration meter to select measurement Power demand: 1 6F22 9V carbon or alkali battery
acceleration, speed or displacement. Right arrow on display will point to selected Service life: To operate for more than 20 hours continuously
measurement unit. Outline dimension: 185 (H) * 68 (W) * 0 (D) mm (for host)
4.Measurement Weight: About 300g (including battery)
Please connect signal wires connected to sensor to input connector of left sensor then absorb 2.Environment Limitation
sensor with magnetic base to vertical cross section of measured article during usage for the Indoor usage
1st time. Instrument can enter into measurement status instantly by pressing measurement Safety standard: GB 4793, 1-2007
key by thumb. Measuring value will be maintained after loosening the key. Measurement also Pollution level: Grade 2
can be continued by pressing measurement key again. Data will be maintained for 1 minute Operation temperature & humidity: 0 ~40 (not more than 90%RH)
after loosening the key and instrument will power off automatically at the same time. (Note: Storage temperature & humidity: 0 ~+40 (not more than 80%RH)
Please tighten clasp when connecting signal wires and hold instrument and sensor in hands Atmospheric pressure: 75~106KPa
after measurement. It is not allowed to hoist sensor by signal wires to avoid influence to 3.Technical Specification
service life of such wires.) Accuracy: 5% of 1 word (% of reading + word quantity); Correction period is 1 year;
Ambient temperature: 0 ~40
Ambient humidity: 80% RH
Temperature coefficient: 0.1*(accuracy)/
Vibration measurement scope 2. General Maintenance
Vibration Vibration Vibration Please inspect signal wires of sensor constantly because instrument may not display due to
Measurement unit acceleration (O-P) speed (RMS) displacement (P-P) damage or poor contact of such wires. It is not allowed to pull or drag signal wires forcefully.
Range Sensor core is closed completely. It can not be detached except sensor signals.
Frequency response Please clean dirty instrument shell by wet cloth and neutral detergent. Please do not use
scope and amplitude error abrasive or solvent.
Please send damaged vibration meter to fixed repair agent or professional repair personnel of
~ ~ ~ our company if required. Please do not try to repair it individually.
Linear error of amplitude
Please do not scratch or contaminate LCD of vibration meter during usage to avoid oil stain,
water leakage, damage or influence to it.
VII.MAINTENANCE Please take battery out if it will not be used for a long time.
Please do not store instruments in wet environment and strong magnetic field under high
Warning: It is not allowed to scratch LCD of vibration meter during battery replacement temperature.
and measurement to avoid damage or influence to measurement precision. It is also not
allowed to charge replaced battery to avoid personal injury due to explosion! 3.Common Troubleshooting
1. Battery installation and replacement Common troubles Possible reason
Be sure to replace battery in a timely manner when symbol of appears for vibration No bootstrap Poor battery contact
meter. Battery replacement method is as follows: Without signal input Broken signal wire
Removing cell cover: Please replace 6F22 9V battery by the same model. Please do not Display of double arrows by gear switchover Poor toggle of toggle switch
install improper battery. Tripping display or system halted Broken toggle switch or poor toggle
Please pay attention to + and - polarity during battery installation.
Please install cell cover after installation.

You might also like