0% found this document useful (0 votes)
79 views4 pages

Instrument Identification Notes & Instructions

This document provides instructions for installing and commissioning level measurement instruments on various vessels. It lists the equipment tag, model, and notes for each instrument. The notes specify things to check like the product code and instructions for installation and commissioning like ensuring the probe tip is positioned correctly and setting the instrument for the proper damping constant.

Uploaded by

Luca Lorati
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views4 pages

Instrument Identification Notes & Instructions

This document provides instructions for installing and commissioning level measurement instruments on various vessels. It lists the equipment tag, model, and notes for each instrument. The notes specify things to check like the product code and instructions for installation and commissioning like ensuring the probe tip is positioned correctly and setting the instrument for the proper damping constant.

Uploaded by

Luca Lorati
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

INSTRUMENT IDENTIFICATION NOTES & INSTRUCTIONS

Equipment Installation Instrument TAG BH Purchase Code Instrument Type Notes for mechanical completion team/commissioning team

Check:
1)"HA1C", "00800" are present in the product code
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) = top of the internal vessel
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.4

GWR 5301 Level Indicator &


V-0450 top mounted on 3" Transmitter, C, 3B probe coaxial
horizontal vessel chamber, cold insulated 104-0xA(B)-LIT-04701 RT-96936 perforated, remote head
Check:
1)"HA1C", "00703" are present in the product code
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) = top of the internal vessel
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.4

E-0420 GWR 5301 Level Indicator &


horizontal vessel top mounted on 3" Transmitter, C, 3B probe coaxial
(warm side) chamber, hot insulated 104-0xA(B)-LIT-04105 RT-96937 perforated, remote head
Check:
1)"HA1S", "00700" and "QT" are present in the product code
2) verify with the actual installation whether cut is needed; in case it is, cut as
required; consult Emerson Reference Manual 00809-0100-4530, Rev GA Oct. 19 or following rev.
before cutting; consult Emerson for support;
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) elev.= 50% internal vessel diam.
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.2

top mounted on 2"


chamber, chamber GWR 5301 Level Indicator &
V-0501 connected side-side to Transmitter, S, 3B probe coaxial
horizontal vessel 6" stand-pipe 104-0xA(B)-LZIT-05200 RT-96938 perforated, remote head
Check:
1) "HA1S", "00700" and "QT" are present in the product code
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) elev.= 50% internal vessel diam.
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required.
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
-set for DC=1.2

GWR 5301 Level Indicator &


V-0502 top mounted on 2" Transmitter, S, 3B probe coaxial
horizontal vessel chamber 104-0xA(B)-LZIT-05500 RT-96938 perforated, remote head
Check: 1) "HA1S", "00700" are present in the product code
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) elev.= 50% internal vessel diam.
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
-set for DC=1.2

top on 2" chamber,


chamber connected GWR 5301 Level Indicator &
V-0502 side-side to 6" stand- Transmitter, S, 3B probe coaxial
horizontal vessel pipe 104-0xA(B)-LIT-05501 RT-96940 perforated, remote head
Check:
1) "HA1P", "00700" are present in the product code
2) cut the probe as required; consult Emerson Reference Manual 00809-0100-4530, Rev GA Oct. 19 or
following rev. before cutting; consult Emerson for support
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) elev.= 50% internal vessel diam.
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required.
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
-set for DC=1.4

GWR 5301 Level Indicator &


V-0503 top mounted on 2" Transmitter, P, 3B probe coaxial
horizontal vessel chamber 104-0xA(B)-LIT-05801 RT-96941 perforated, remote head
Check: 1) "HA1C", "00500" and "QT" are present in the product code
Other notes:
- 0% (LRV) elev. = 400mm from internal bottom of the vessel=13.6% internal vessel diam.; 100% (URV)
elev. =50% internal vessel diam.
- set for DC=1.4

GWR 5301 Level Indicator &


V-1110 top mounted on 3" Transmitter, C, 3B probe coaxial
horizontal vessel chamber, cold insulated 104-0xA(B)-LIT-26001 RT-96944 perforated, remote head
Check: 1) "HA1C", "00500" and "QT" are present in the product code
Other notes:
- 0% (LRV) elev. = 400mm from internal bottom of the vessel=13.6% internal vessel diam.; 100% (URV)
elev. =50% internal vessel diam.
- set for DC=1.4

GWR 5301 Level Indicator &


V-1110 top mounted on 3" Transmitter, C, 3B probe coaxial
horizontal vessel chamber, cold insulated 104-0xA(B)-LZIT-26000 RT-96944 perforated, remote head
Check: 1)"HA1C", "00711" are present in the product code
Other notes:
- 0% (LRV) elev. = internal bottom of the vessel; 100% (URV) = top of the internal vessel
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.4

E-0420 GWR 5301 Level Indicator &


horizontal vessel top mounted on 3" Transmitter, C, 3B probe coaxial
(cold side) chamber, hot insulated 104-0xA(B)-LIT-04106 RT-96945 perforated, remote head
Check: 1)"HA1C", "00611" are present in the product code
Other notes:
- 0% (LRV) elev. = vessel BTL; 100% (URV) = vessel TTL
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.4

V-0401
vertical vessel GWR 5301 Level Indicator &
(inside cold box Z- top mounted on 3" Transmitter, C, 3B probe coaxial
0401) chamber, cold insulated 104-0xA(B)-LIT-04102 RT-96942 perforated, remote head
Check: 1)"HA1S", "01002" are present in the product code
Other notes:
- 0% (LRV) elev. = vessel BTL; 100% (URV) = upper chamber flange CL
- probe TIP shall not contact the bottom of the pipe/chamber: 5mm clearance min. required
- ensure with actual installation that probe tip extends at least 150mm below
0% (LRV)
- set for DC=1.2

V-0510 GWR 5301 Level Indicator &


vertical vessel top mounted on 2" Transmitter, S, 3B probe coaxial
(loose stick-built) chamber 104-0xA(B)-LIT-05401 RT-96943 perforated, head mounted

REFERENCE DRAWINGS FOR MECHANICAL ASSEMBLY VERIFICATION


SOK6631205 Isometric Drawings rev.6
SOK2314708 E-0420 Reboiler Constr. Drawing rev.1
SOK2314707 Flare KO Drum V-1110 Constr. Drawing rev.2
SOK2314706 MR V-0503 Constr. Drawing rev.2
SOK2314705 2nd Stage Suction Scrubber V-0502 Constr. Drawing rev.2
SOK2314704 1st Stage Suction Scrubber V-0501 Constr. Drawing rev.2
SOK2314703 LNG Flash Vessel V-0450 Constr. Drawing rev.2
SOK0975549 V-0510 Surge Vessel Constr. Drawing rev.2