You are on page 1/ 3

Diagnostic Products Product Selection Guide

SensoControl® Diagnostic Meters and Test Port Couplings

A Pneumatics
Meter Selection Guide
The Parker The Parker The Parker Service The Parker Service
Service Junior Serviceman Plus Master Easy Master Plus
Pressure Sensing

B Hydraulics
n n n n
Flow Sensing n n n
Temperature Sensing n n n
Rotational Speed Sensing n n n
Auxiliary Sensing n n n
Pressure Differential

C Thermoplastics
n n n
Automatic Sensor Recognition n n n

Frequency Sensing n n n
Auto Power Off n n n n
Battery Monitoring n n n n

Battery Type AA (2 req’d) Rechargeable LI-ion Rechargeable Ni-MH Rechargeable LI-ion


PC Compatible (Windows 7) n n n

D Swivels
Minimum/Maximum Memory n n n n
Self Contained Memory n n n
On-Line Data Transfer n n n
Text Display (Lines) 2 4 8 48
Inputs 1 2-3 4 26
Data Points (Maximum in Memory) 270,000 1,000,000 1,000,000,000

E Valves
Numbered LCD Display n n n n
Basic Hydraulic Calculations n n n
USB Interface n n n
CAN Sensors n n
Graphic Color Display n

F Diagnostic
Additional Storage Media n n

The Parker Serviceman Plus, Parker Service Master Easy and the Parker Service Master Plus require the appropriate sensors to perform measurement functions.

Test Port Coupling Selection Guide

Body Material* Locking Rated


Test Port Valving Style Standard Seal Material Temp Range**
Size Mechanism Pressure
Br SS S

PD Series Flush Face 1/8” n n n Ball Nitrile 6000 psi -40° to +250° F
Appendices

PDP Series Ball (Nipple only) 1/8” n Ball Nitrile 6000 psi -40° to +250° F
EMA3 Series Poppet 1/8” n n Threads Nitrile/Fluorocarbon 9000 psi -15° to +250° F

* See Fluid Compatibility chart and/or consult QCD for questions regarding proper material for specific applications.
CODE: Br = Brass; SS = Stainless Steel; S = Steel
** Temperature Range for standard seal material

F-3 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
Diagnostic Products ServiceJunior™
SensoControl® Digital Pressure Gauge

The Parker ServiceJunior is an integrated digital pressure


gauge with minimum/maximum memory capability.
A Pneumatics

Capabilities:
• Hand held digital pressure gauge
• Measure and Display
-Pressure

Features:
B Hydraulics

• Easy operation
• Backlit display
• User-adjustable pressure units
• Min/Max memory
• Battery life indicator applications
C Thermoplastics

• Ranges for hydraulics and pneumatics


• Scanning rate of 10ms
• Fluid temperature: -4° to 176° F
• Colored covers correspond with pressure ranges for easy
identification

Cover Color Code


Blue -14.5 to 230 PSI (-1 to 16 bar)
D Swivels

Green 0 to 1500 PSI (0 to 100 bar)


Orange 0 to 5800 PSI (0 to 400 bar)
Red 0 to 8700 PSI (0 to 600 bar)

Part Numbers and Specifications


ServiceJunior Overload
ServiceJunior with ServiceJunior with Resolution
with PD Measuring Range Pressure Accuracy
E Valves

EMA3 Coupler 1/4”NPT Port (psi)


Coupler (psi)
SCJR-0250-PD SCJR-0250-EMA SCJR-0250-4MP -14.5 to 230 PSI (-1 to 16 bar) 580 0.1
SCJR-1500-PD SCJR-1500-EMA SCJR-1500-4MP 0 to 1500 PSI (0 to 100 bar) 2,900 1
0.5% FS
SCJR-5800-PD SCJR-5800-EMA SCJR-5800-4MP 0 to 5800 PSI (0 to 400 bar) 11,600 1
SCJR-8700-PD* SCJR-8700-EMA** SCJR-8700-4MP 0 to 8700 PSI (0 to 600 bar) 17,400 1
* PD Couplers rated to 6,000 PSI max
F Diagnostic

** EMA3 Couplers rated to 9,000 PSI max

Accessories
Part Number Description
PD240 PD Series Diagnostic Coupler
SCA-7/16-EMA-3 7/16 - 20UNF-2B female to M16X2.0 EMA3 female swivel
SCJA-1/4 7/16 - 20UNF-2B female to 1/4” NPT male adapter
PDH-19 19” PD Hose extension to be used with PD nipple
Appendices

PDH-32 32” PD Hose extension to be used with PD nipple


SMA3-400 16” (400 mm) Hose assembly for EMA M16X2.0 interface
SCC-110 Storage case for one gauge and diagnostic adapters
SCC-300 Storage case for three gauges and diagnostic adapters

F-4 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
Diagnostic Products ServiceJunior™
SensoControl® Diagnostic Tee Kits

A Pneumatics
B Hydraulics
PD Style Kits

SCJR1-KIT-PD SCJR2-KIT-PD SCJR3-KIT-PD

C Thermoplastics
ServiceJunior Gauge: ServiceJunior Gauge: ServiceJunior Gauge:
1 1 1
Range: 0 to 5800 psi (0 to 400 bar) Range: 0 to 1500 psi (0 to 100 bar) Range: -14.5 to 230 psi (-1 to 16 bar)
PD style JIC Tee Fittings ServiceJunior Gauge: ServiceJunior Gauge:
6 1 1
1/4 through 1 inch sizes Range: 0 to 5800 psi (0 to 400 bar) Range: 0 to 1500 psi (0 to 100 bar)
PD style ORFS Tee Fttings PD style JIC Tee Fittings ServiceJunior Gauge:
6 6 1
1/4 through 1 inch sizes 1/4 through 1 inch sizes Range: 0 to 5800 psi (0 to 400 bar)
PD style Whip Hose PD style ORFS Tee Fttings PD style JIC Tee Fittings
1 6 6
32 inch (800 mm) length 1/4 through 1 inch sizes 1/4 through 1 inch sizes
Case - includes 3 plastic PD style Whip Hoses PD style ORFS Tee Fttings

D Swivels
1 2 6
storage compartments 32 inch (800 mm) length 1/4 through 1 inch sizes
Case - includes 3 plastic PD style Whip Hoses
1 3
storage compartments 32 inch (800 mm) length
Case - includes 3 plastic
1
storage compartments

EMA Style Kits

E Valves
SCJR1-KIT-EMA SCJR2-KIT-EMA SCJR3-KIT-EMA
ServiceJunior Gauge: ServiceJunior Gauge: ServiceJunior Gauge:
1 1 1
Range: 0 to 5800 psi (0 to 400 bar) Range: 0 to 1500 psi (0 to 100 bar) Range: -14.5 to 230 psi (-1 to 16 bar)
EMA style JIC Tee Fittings ServiceJunior Gauge: ServiceJunior Gauge:
6 1 1
1/4 through 1 inch sizes Range: 0 to 5800 psi (0 to 400 bar) Range: 0 to 1500 psi (0 to 100 bar)
EMA style ORFS Tee Fittings EMA style JIC Tee Fittings ServiceJunior Gauge:
6 6 1

F Diagnostic
1/4 through 1 inch sizes 1/4 through 1 inch sizes Range: 0 to 5800 psi (0 to 400 bar)
EMA style Whip Hose EMA style ORFS Tee Fittings EMA style JIC Tee Fittings
1 6 6
32 inch (800 mm) lengt 1/4 through 1 inch sizes 1/4 through 1 inch sizes
EMA style Union EMA style Whip Hoses EMA style ORFS Tee Fttings
1 2 6
female to male adapter 32 inch (800 mm) length 1/4 through 1 inch sizes
Case - includes 3 plastic EMA style Unions EMA style Whip Hoses
1 2 3
storage compartments female to male adapter 32 inch (800 mm) length
Case - includes 3 plastic EMA style Unions
1 3
storage compartments female to male adapter
Appendices

Case - includes 3 plastic


1
storage compartments

F-5 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings