0% found this document useful (0 votes)
85 views

Technical Data For Boiler Unit

This document provides technical specifications for a boiler unit including: general project information; dimensions; water/steam process data; combustion process data; data for atomizing steam and electric systems; pressure part details; burner specifications; water level and steam pressure operations; and manual information. The boiler unit has a steam output of 18,000 kg/h and works at a pressure of 7.0 kg/cm2. It uses diesel or fuel oil and has dimensions of 3,220mm in diameter and 9,100mm in total height.

Uploaded by

nestor mospan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views

Technical Data For Boiler Unit

This document provides technical specifications for a boiler unit including: general project information; dimensions; water/steam process data; combustion process data; data for atomizing steam and electric systems; pressure part details; burner specifications; water level and steam pressure operations; and manual information. The boiler unit has a steam output of 18,000 kg/h and works at a pressure of 7.0 kg/cm2. It uses diesel or fuel oil and has dimensions of 3,220mm in diameter and 9,100mm in total height.

Uploaded by

nestor mospan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

TECHNICAL DATA FOR BOILER UNIT 735430#01.

Technical data for boiler unit

1 General data

 Project No.:.......735430,735432,735434,735436,735438,735440,735442,735444,735446
 Hull No.:.........................SAS-411,-412,-417,-418,-419,-423,-424,-425,-426
 Classification society:...........................................................................RINA
 Pressure gauge calibration:..................................................................kg/cm2
 Thermometer calibration:...........................................................................°C
 Language for signs:...................................................................................UK

2 Dimensions for boiler unit

 Height to top of local control panel:...............................................8,010 mm


 Diameter incl. insulation:................................................................3,220 mm
 Total height incl. retraction of burner lance:...................................9,100 mm
 Weight of boiler unit excl. water:....................................................26,500 kg
 Weight of boiler unit incl. water:....................................................36,700 kg

3 Water/steam process data

 Steam output:...............................................................................18,000 kg/h


 Working pressure:..........................................................................7.0 kg/cm2
 Max. allowable working pressure:.................................................9.0 kg/cm2
 Working temperature:...........................................................................170°C
 Feed water operation:...................................................................modulating
 Feed water temperature, operation:...................................................85-95°C
 Feed water temperature, layout:..............................................................60°C

4 Combustion process data

 Min. calorific value of diesel oil:................................................42,200 kJ/kg


 Min./max. viscosity of diesel oil:..........................................4/12 cSt at 50°C
 Density of diesel oil:.......................................................................820 kg/m3

Language UK Page 1/4


TECHNICAL DATA FOR BOILER UNIT 735430#01.0

 Min. calorific value of fuel oil:...................................................40,200 kJ/kg


 Max. viscosity of fuel oil:......................................................700 cSt at 50°C
 Density of fuel oil:..........................................................................990 kg/m3
 Fuel oil temperature before pre-heater:...................................................55°C
 Fuel oil viscosity at burner inlet:...........................................................15 cSt
 Fuel oil temperature at burner inlet:......................................................140°C
 Ambient air temperature:........................................................................45°C
 Air excess No. at 100% load:...................................................................1.15
 Flue gas temperature (clean boiler):.....................................................346°C
 Air consumption at 100% load:....................................................20,530 kg/h
 Flue gas flow (approx.):...............................................................21,853 kg/h
 Pressure loss across pin elements:...............................................183 mmWC
 Expected back pressure from stack at full load:............................15 mmWC

5 Data for atomising steam

 Atomising steam pressure at burner, max.:....................................6.5 kg/cm2


 Atomising steam consumption, max.:.................................................78 kg/h
 Atomising air pressure at burner, max.:.........................................6.5 kg/cm2
 Atomising air consumption, max.:....................................................138 kg/h

6 Data for electric systems

 Power supply:......................................................................3 x 440 V, 60 Hz


 Control voltage:...................................................................1 x 220 V, 60 Hz
 Pilot voltage:............................................................................................24V
 Insulation class:....................................................................................B or F
 Degree of protection:...............................................................................IP44
 Colour of local control panel:..........................................Munsell 7.5 BG 7/2
 Colour of power panel:....................................................Munsell 7.5 BG 7/2

7 Data for pressure part

 Boiler type:....................................................................Large oil fired boiler


 Model:.............................................................MISSION OL model 20000
 Test pressure:...............................................................................13.5 kg/cm2
 Number of pin elements:.............................................................................81

Language UK Page 2/4


TECHNICAL DATA FOR BOILER UNIT 735430#01.0

 Protection of boiler body:...........................................trapezoid plate 10x100


 Colour of insulation plates:................................................hot dip galvanized

8 Data for burner

 Burner type:......................................................Steam atomising, modulating


 Model:.........................................................................................KBSD 1500
 Burner capacity on diesel oil, min./max.:................................150/1,243 kg/h
 Burner capacity on fuel oil, min./max.:...................................150/1,305 kg/h
 Colour of burner................................................................................standard

9 Data for water level operation

 Too high water level alarm:.............................................................+165 mm


 High water level warning:...............................................................+135 mm
 Normal water level:...............................................................................0 mm
 Start stand-by feed water pump:...............................mm/bar g/not AI supply
 Low water level warning:.................................................................-145 mm
 Too low water level alarm:...............................................................-190 mm

10 Data for steam pressure operation

 Safety valve:..................................................................................9.0 kg/cm2


 Safety valve:..................................................................................9.0 kg/cm2
 High steam pressure alarm and burner off:....................................8.5 kg/cm2
 High steam pressure warning:........................................................8.3 kg/cm2
 Steam dump opening pressure:......................................................8.2 kg/cm2
 Burner start/stop:.....................................................................7.2/8.2 kg/cm2
 Burner operation:...........................................................................7.0 kg/cm2
 Low steam pressure warning:........................................................4.0 kg/cm2

Language UK Page 3/4


TECHNICAL DATA FOR BOILER UNIT 735430#01.0

11 Manuals

 Language for manuals:..............................................................................UK


 Set of instruction manuals:...........................................................................5
 Document revision date:................................................................April 2002

Language UK Page 4/4