10/13/16 kW

GUARDIAN® SERIES
10/13/16 kW Residential Standby Generators
Air-Cooled Gas Engine
1 of 6

Standby Power Rating


INCLUDES:
G007171-0, G007172-0 (Aluminum - Bisque) – 10 kW 60 Hz
 True Power™ Electrical Technology G007173-0, G007174-0, G007175-0 (Aluminum - Bisque) – 13 kW 60 Hz
G007176-0, G007177-0, G007178-0 (Aluminum - Bisque) – 16 kW 60 Hz
 Two-line multilingual digital LCD Evolution™ controller 
(English/Spanish/French/Portuguese)
 Two transfer switch options available: 
100 amp 16 circuit switch or 
200 amp service rated smart switch
 Electronic governor
 Standard Wi-Fi™ connectivity
 System status & maintenance interval LED indicators
 Sound attenuated enclosure
 Flexible fuel line connector
 Natural gas or LP gas operation
 5 Year limited warranty
 Listed and labeled by the Southwest Research Institute
or
allowing installation as close as 18 in (457 mm) to a
structure.*
*Must be located away from doors, windows, and fresh air Note: CETL or CUL certification only applies to unbundled units and units packaged with limited
intakes and in accordance with local codes. circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only.
https://assets.swri.org/library/DirectoryOfListedProducts/
ConstructionIndustry/973_DoC_204_13204-01-01_Rev9.pdf

FEATURES
 INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of  SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
Generac’s success in providing the most reliable generators possible. Generac’s G- state-of-the-art power maximizing regulation system is standard on all Generac
Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and
the most. The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the
rigors of extended run times in high temperatures and extreme operating conditions. surge loads to the engine. Digital voltage regulation at ±1%.
 TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave  SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network
form produce less than 5% Total Harmonic Distortion for utility quality power. This provides parts and service know-how for the entire unit, from the engine to the
allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component.
appliances, such as variable speed HVAC systems.
 TEST CRITERIA:  GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC
 PROTOTYPE TESTED  NEMA MG1-22 EVALUATION
product line is offered with its own transfer systems and controls for total system
 SYSTEM TORSIONAL TESTED  MOTOR STARTING ABILITY
compatibility.
 MOBILE LINK™ WI-FI CONNECTIVITY: FREE with select Guardian Series home
standby generators, Mobile Link Wi-Fi allows users to monitor the status of the
generator from anywhere in the world using a smartphone, tablet, or PC. Easily
access information such as the current operating status and maintenance alerts.
Users can connect an account to an authorized service dealer for fast, friendly, and
proactive service. With Mobile Link, users are taken care of before the next power
outage.

TM
®
10/13/16 kW

10/13/16 kW Features and Benefits


Engine
 Generac G-Force design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
 “Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life.
 Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
 Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer
2 of 6
engine life. Now featuring up to a 2 year/200 hour oil change interval.
 Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
 High temperature shutdown Prevents damage due to overheating.

Generator
 Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
 Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
 Displaced phase excitation Maximizes motor starting capability.
 Automatic voltage regulation Regulating output voltage to ±1% prevents damaging voltage spikes.
 UL 2200 listed For your safety.

Transfer Switch (if applicable)


 Fully automatic Transfers vital electrical loads to the energized source of power.
 NEMA 3R Can be installed inside or outside for maximum flexibility.
 Remote mounting Mounts near an existing distribution panel for simple, low-cost installation.

Evolution™ Controls
 AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy, at-a-glance status indication in any condition.
 Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
 Sealed, raised buttons Smooth, weather-resistant user interface for programming and operations.
 Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
 Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home.
 Utility interrupt delay Prevents nuisance startups of the engine, adjustable 2–1500 seconds from the factory default setting of
5 seconds by a qualified dealer.
 Engine warm-up Verifies engine is ready to assume the load. Setpoint approximately 5 seconds.
 Engine cool-down Allows engine to cool prior to shutdown. Setpoint approximately 1 minute.
 Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing
flexibility and potentially lower fuel costs to the owner.
 Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
 Main line circuit breaker Protects generator from overload.
 Electronic governor Maintains constant 60 Hz frequency.

Unit
 SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
 Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
 Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
®

10/13/16 kW
10/13/16 kW Features and Benefits
Installation System
 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
 Integral sediment trap Meets IFGC and NFPA 54 installation requirements.

Connectivity
 Ability to view generator status Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application 3 of 6
for complete peace of mind.
 Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
 Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due.
 Monthly report with previous month’s activity Detailed monthly reports provide historical generator information.
 Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
 Weather information Provides detailed local ambient weather conditions for generator location.
®
10/13/16 kW

10/13/16 kW Specifications
Generator
Model G007171-0, G007172-0 G007173-0, G007174-0, G007176-0, G007177-0,
(10 kW) G007175-0 (13 kW) G007178-0 (16 kW)
Rated maximum continuous power capacity (LP) 10,000 Watts* 13,000 Watts* 16,000 Watts*
Rated maximum continuous power capacity (NG) 9,000 Watts* 13,000 Watts* 16,000 Watts*
Rated voltage 240
Rated maximum continuous load current – 240 volts (LP/NG) 41.7 / 37.5 54.2 / 54.2 66.7 / 66.7
Total Harmonic Distortion Less than 5%
4 of 6 Main line circuit breaker 45 Amp 60 Amp 70 Amp
Phase 1
Number of rotor poles 2
Rated AC frequency 60 Hz
Power factor 1.0
Battery requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
Unit weight (lb/kg) 338/153 385/175 420/191
Dimensions (L x W x H) in / cm 48 x 25 x 29 / 121.9 x 63.5 x 73.7
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load** 61 65 65
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode** 57 55 55
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series
Number of cylinders 1 2
Displacement 460 cc 816 cc
Cylinder block Aluminum w/ cast iron sleeve
Valve arrangement Overhead valve
Lifter type Solid Hydraulic
Ignition system Solid-state w/ magneto
Governor system Electronic
Compression ratio 9.5:1
Starter 12 VDC
Oil capacity including filter Approx. 1.1 qt / 1.0 L Approx. 2.2 qt / 2.1 L
Operating rpm 3,600
Fuel consumption
Natural Gas ft³/hr (m³/hr)
1/2 Load 101 (2.86) 154 (4.36) 182 (5.15)
Full Load 127 (3.60) 225 (6.37) 245 (6.94)
Liquid Propane ft3/hr (gal/hr) [L/hr]
1/2 Load 36 (0.97) [3.66] 56 (1.54) [5.83] 62 (1.70) [6.45]
Full Load 54 (1.48) [5.62] 90 (2.45) [9.28] 109 (2.99) [11.32]
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5–7.0 in water column (0.87–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LP
gas. For BTU content, multiply ft3/hr x 2,500 (LP) or ft3/hr x 1,000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser.
MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place.
OFF Stops unit. Power is removed. Control and charger still operate.
Ready to Run/Maintenance messages Standard
Engine run hours indication Standard
Programmable start delay between 2–1500 seconds Standard (programmable by dealer only)
Utility voltage loss/Return to utility adjustable (brownout setting) From 140-171 V / 190-216 V
Future set capable exerciser/Exercise set error warning Standard
Run/Alarm/Maintenance logs 50 events each
Engine start sequence Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration).
Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Charger Fault/Missing AC Warning Standard
Low Battery/Battery Problem Protection and Battery Condition Indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overcurrent Protection Standard
Safety Fused/Fuse Problem Protection Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal Fault/Incorrect Wiring Protection Standard
Common External Fault Capability Standard
Field Upgradable Firmware Standard
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for
supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum kilovolt amps
and current are subject to and limited by such factors as fuel BTU (Megajoule) content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each
1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 6 °C (10 °F) above 16 °C (60 °F).
®

10/13/16 kW
10/13/16 kW Switch Options
G007172-0 G007174-0 G007177-0
Limited Circuits Switch Features Model
(10 kW) (13 kW) (16 kW)
 16 space, 24 circuit. Breakers not included. No. of poles 2
 Electrically operated, mechanically-held contacts for fast, positive connections. Current rating (amps) 100
 Rated for all classes of load, 100% equipment rated, both inductive and Voltage rating (VAC) 120 / 240, 1Ø
resistive.
Utility voltage monitor (fixed)*
 2-pole, 250 VAC contactors. -Pick-up 80%
 30 millisecond transfer time. -Dropout 65% 5 of 6
 Dual coil design. Return to utility* Approx. 15 sec
 Rated for both copper and aluminum conductors. Exercises bi-weekly for  Standard
 Main contacts are silver plated or silver alloy to resist welding and sticking. 5 minutes*
 NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor ETL or UL Listed Standard
mounting flexibility.
Total circuits available 24
 Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from
Tandem breaker capabilities 8 tandems
Siemens, Murray, Eaton, and Square D for the most flexible and cost effective
install. Circuit breaker protected
Available RMS Symmetrical 10,000
Fault Current @ 250 Volts
Dimensions *Function of Evolution controller
Exercise can be set to weekly or monthly
Height Width W1
Depth
H1 H2 W1 W2
in 26.75 30.1 10.5 13.5 6.91
cm 67.94 76.43 26.67 34.18 17.54

Wire Ranges H2 H1

Conductor Lug Neutral Lug Ground Lug


2/0 - #14 2/0 - #14 2/0 - #14

DEPTH W2

Service Rated Smart Switch Features Model


G007175-0 G007178-0
 Includes Smart A/C Management (SACM) module standard. (13 kw) (16 kW)
 Intelligently manages up to four air conditioner loads with no additional No. of poles 2
hardware. Current rating (amps) 200
 Up to eight large (240 VAC) loads can be managed with Smart Management Voltage rating (VAC) 120/240, 1Ø
Modules (SMMs). Utility voltage monitor (fixed)*
 Electrically operated, mechanically-held contacts for fast, clean connections. -Pick-up 80%
 Rated for all classes of load, 100% equipment rated, both inductive and -Dropout 65%
resistive. Return to utility* 15 sec
 2-pole, 250 VAC contactors. Exercises bi-weekly for 5 minutes* Standard
 Service equipment rated, dual coil design. ETL or UL Listed Standard
 Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R
 Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000
 NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM - #6
mounting flexibility.
*Function of Evolution Controller
Dimensions Exercise can be set to weekly or monthly
W1

200 Amps 120/240, 1ø


Open Transition Service Rated
Height Width
Depth
H1 H2 W1 W2
in 26.75 30.1 10.5 13.5 6.3
H1
cm 67.94 76.45 26.67 34.3 16.01
H2

Wire Ranges
Conductor Lug Neutral Lug Ground Lug
400 MCM - #4 350 MCM - #6 2/0 - #14
DEPTH W2
®
10/13/16 kW

10/13/16 kW Available Accessories


Model # Product Description
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell
G005819-0 26R Wet Cell Battery
battery for use with all air-cooled standby product (excluding PowerPact®).
The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18
G007101-0 Battery Pad Warmer
°C). (Not necessary for use with AGM-style batteries).
Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 °F (-18
6 of 6 G007102-0 Oil Warmer
°C).
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in
G007103-1 Breather Warmer
climates where heavy icing occurs.
Auxiliary Transfer Switch  The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you
G005621-0
Contact Kit may not need. Not compatible with 50 amp pre-wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek,
G007027-0 - Bisque Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes lo-
cated in the base.
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future
G005703-0 - Bisque Touch-Up Paint Kit
corrosion. The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006482-0 – 10 kW Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance
Scheduled Maintenance Kit
G007216-0 – 13 / 16 kW on a Generac automatic standby generator (oil not included).
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring
G007005-0 Wi-Fi LP Fuel Level Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power
failure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill.
Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages
G007000-0 (50 amps)
Smart Management Module large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using
G007006-0 (100 amps)
SMM’s can reduce the overall size and cost of the system.
The Mobile Link 4G LTE Cellular Accessory allows users to monitor the status of the generator from anywhere
Mobile Link™ 4G LTE Cellular  in the world, using a smartphone, tablet, or PC. Easily access information such as the current operating status
G007169-0
Accessory and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and
proactive service. With Mobile Link, users are taken care of before the next power outage.

Dimensions & UPCs


1218 mm
637.6 mm [48.0 in]
[25.1 in]
Model UPC
G007171-0 696471074680
G007172-0 696471074673
G007173-0 696471076400 727.2 mm
[28.6 in]

G007174-0 696471077100
G007175-0 696471077117
G007176-0 696471076417
G007177-0 696471077124
648 mm 1232 mm
[25.5 in]
G007178-0 696471077131 LEFT SIDE VIEW
[48.5 in]

FRONT VIEW

Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com