0% found this document useful (0 votes)
95 views

Magnetic Particle Testing Report

The magnetic particle testing report summarizes an inspection of 1690 socket flat head screws and rivet nuts. Magnetic particle testing was performed according to ASME and ASTM standards using wet fluorescent particles to inspect all accessible surfaces. No defects were found and the parts passed inspection criteria. The inspection utilized an Ultramag NDT Systems yoke equipment with a 4.5 kg lifting capacity operating on 220 volts AC current.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views

Magnetic Particle Testing Report

The magnetic particle testing report summarizes an inspection of 1690 socket flat head screws and rivet nuts. Magnetic particle testing was performed according to ASME and ASTM standards using wet fluorescent particles to inspect all accessible surfaces. No defects were found and the parts passed inspection criteria. The inspection utilized an Ultramag NDT Systems yoke equipment with a 4.5 kg lifting capacity operating on 220 volts AC current.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

MAGNETIC PARTICLE TESTING REPORT

Report no : AXIS/MPT/079/46 Date of inspection : 01/06/2020


Client : TEC AERO DEVICES Project : HH/PO-012/1187/2020-21

Job Description : Socket Flat Head Screws ISO Quantity : 1690


10642 & Rivet Nuts BN 224

Socket Flat Head Screws ISO 10642 Socket Flat Head Screws ISO 10642
1) 1. M3*16= 150 NO’s 7) 12. M6*25= 520 NO’s
2) 2.M5*20= 100 NO’s 8) 19.M3*8= 100 NO’s
3) 3. M5*25= 100 NO’s 9) 13. M6*40= 120 NO’s
4) 4.M6*16= 100 NO’s Rivet Nuts BN 224
5) 5.M6*20= 100 NO’s 10) 7. M6*14 = 100 NO’s
6) 6.M6*24= 100 NO’s 11) 8.M6*15 = 100 NO’s
12) 10.M6*18 = 100 NO’s
Material : AISI 4135 Procedure No : ASME SEC V, Article – 7,ASTM E1444
Temperature : Ambient Acceptance criteria : ASME SEC V, Article - 7
Equipment Trade Mark: Ultramag NDT Systems Equipment Sr No : 20130311516
Equipment Type : YOKE Cal due date :30/09/2020
Type of Magnetism : Rounded Testing medium: Wet fluorescent Lifting capacity: 4.5 KGS
Current Used AC/DC: AC Current Range: 220 Volts
Stage of Examination: Inspection Surface preparation: Satisfactory
Demagnetization : N/A Post – Cleaning : Done

Inspection coverage:
Magnetic Particle Testing was performed on all accessible areas of the above mentioned weld joints.
MPT Inspection Results:
No defect indications were observed at the time of inspection, and found acceptable as per
the applicable acceptance criteria.

Tested By: Witnessed By: Client:

L.JANAKIRAM
(ASNT NDT L-II UT,RT,MT,PT)

Note: This Results Belongs to only the item tested above. Format No: MT/003/Rev-02