1000uf Cap
1000uf Cap
ESK, +85°C
Overview Applications
The KEMET ESK single-ended aluminum electrolytic Typical applications include general purpose coupling,
capacitors are designed for high-density printed circuit decoupling, bypass, and filtering in consumer electronics.
boards requiring a miniature solution.
Benefits
• Operating temperature of up to 85°C
• 2,000 hour operating life
• Case with Ø D ≥ 5 mm
• Safety vent on the capacitor base
Environmental Compliance
As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental
effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like
China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic
equipment. All products in this catalog are produced to help our customers’ obligations to guarantee their products and fulfill
these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed
from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will
closely follow any changes in legislation world wide and make any necessary changes in its products, whenever needed.
Some customer segments such as medical, military and automotive electronics may still require the use of lead in electrode
coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels
for RoHS compatible capacitors.
Due to customer requirements, there may appear additional markings such as lead free (LF) or lead-free wires (LFW) on the
label.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 2
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Dimensions – Millimeters
D
LL−
D L p d LL+/LL−
Size Code
Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance
C3 5.0 ±0.5 11.0 +1.5/-0 2.0 ±0.5 0.5 Nominal 20/15 Mininimum
E3 6.3 ±0.5 11.0 +1.5/-0 2.5 ±0.5 0.5 Nominal 20/15 Mininimum
G3 8.0 ±0.5 11.0 +1.5/-0 3.5 ±0.5 0.6 Nominal 20/15 Mininimum
G7 8.0 ±0.5 14.0 +2.0/-0 3.5 ±0.5 0.6 Nominal 20/15 Mininimum
G4 8.0 ±0.5 15.0 +2.0/-0 3.5 ±0.5 0.6 Nominal 20/15 Mininimum
H9 10.0 ±0.5 12.5 +1.5/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
H1 10.0 ±0.5 12 +1.5/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
H2 10.0 ±0.5 15.0 +2.0/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
H4 10.0 ±0.5 20.0 +2.0/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
L2 13.0 ±0.5 16.0 +2.0/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
L3 13.0 ±0.5 20.0 +2.0/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
L4 13.0 ±0.5 25.0 +2.0/-0 5.0 ±0.5 0.6 Nominal 20/15 Mininimum
M7 16.0 ±0.5 25.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
M1 16.0 ±0.5 26.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
M2 16.0 ±0.5 32.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
M3 16.0 ±0.5 36.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
M4 16.0 ±0.5 40.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
N5 18.0 ±0.5 25.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
N1 18.0 ±0.5 32.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
N2 18.0 ±0.5 36.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
N3 18.0 ±0.5 40.0 +2.0/-0 7.5 ±0.5 0.8 Nominal 20/15 Mininimum
Q3 22.0 ±0.5 35.0 +2.0/-0 10.0 ±0.5 0.8 Nominal 20/15 Mininimum
Q4 22.0 ±0.5 40.0 +2.0/-0 10.0 ±0.5 0.8 Nominal 20/15 Mininimum
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 3
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Performance Characteristics
Life Test 2,000 hours (see conditions in Test Methods & Performance)
Z (−25°C)/Z (20°C) 8 6 5 3 3 7 10 15
Z (−40°C)/Z (20°C) 10 8 6 4 3 – – –
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 4
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Ripple Current Maximum ripple current specified at 120 Hz 85°C No ripple current applied
The sum of DC voltage and the peak AC voltage
Voltage No voltage applied
must not exceed the rated voltage of the capacitor.
Performance The following specifications will be satisfied when the capacitor is restored to 20°C:
Capacitance Change Within ±20% of the initial value
Shelf Life
The capacitance, ESR and impedance of a capacitor will not change significantly after extended storage periods, however,
the leakage current will very slowly increase.
KEMET's E aluminum electrolytic capacitors should not be stored in high temperatures or where there is a high level of
humidity. The suitable storage condition for KEMET's E aluminum electrolytic capacitors is +5 to +35°C and less than 75%
in relative humidity. KEMET's E aluminum electrolytic capacitors should not be stored in damp conditions such as water,
saltwater spray or oil spray. KEMET's E aluminum electrolytic capacitors should not be stored in an environment full of
hazardous gas (hydrogen sulphide, sulphurous acid gas, nitrous acid, chlorine gas, ammonium, etc.) KEMET's E aluminum
electrolytic capacitors should not be stored under exposure to ozone, ultraviolet rays or radiation.
If a capacitor has been stored for more than 18 months under these conditions and it shows increased leakage current,
then a treatment by voltage application is recommended.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 5
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 6
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 7
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 8
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 9
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 10
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
(1) Insert packaging code. See Ordering Options Table for available options.
* When capacitance exceeds 1,000 µF, the DF value (%) is increased by 2% for every additional 1,000 µF.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 11
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Installing
• As a general principle, lower-use temperatures result in a longer, useful life of the capacitor. For this reason, it should be
ensured that electrolytic capacitors are placed away from heat-emitting components. Adequate space should be allowed
between components for cooling air to circulate, particularly when high ripple current loads are applied. In any case, the
maximum category temperature must not be exceeded.
• Do not deform the case of the capacitors or use capacitors with a deformed case.
• Verify that the connections of the capacitors are able to insert on the board without excessive mechanical force.
• If the capacitors require mounting through additional means, the recommended mounting accessories shall be used.
• Verify the correct polarization of the capacitor on the board.
• Verify that the space around the pressure relief device is according to the following guideline:
> 16 to ≤ 40 mm > 3 mm
> 40 mm > 5 mm
It is recommended that capacitors always be mounted with the safety device uppermost or in the upper part of the capacitor.
• If the capacitors are stored for a long time, the leakage current must be verifi ed. If the leakage current is superior to the
value listed in this catalog, the capacitors must be reformed. In this case, they can be reformed by application of the rated
voltage through a series resistor approximately 1 kΩ for capacitors with VR ≤ 160 V (5 W resistor) and 10 kΩ for the other
rated voltages.
• In the case of capacitors connected in a series, a suitable voltage sharing must be used.
In the case of balancing resistors, the approximate resistance value can be calculated as: R = 60/C.
KEMET recommends, nevertheless, to ensure that the voltage across each capacitor does not exceed its rated voltage.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 12
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
The capacitive component of the equivalent series circuit, (equivalent series capacitance - ESC), is determined by applying
an alternate voltage of ≤ 0.5 V at a frequency of 120 or 100 Hz and 20°C (IEC 384-1, 384-4).
1 C = capacitance (F)
C=
2π fZ f = frequency (Hz)
Z = impedance (Ω)
reactive
ideal δ
actual
active
Tan δ is measured with the same set-up used for the series capacitance ESC.
Tan δ = ω x ESC x ESR where:
ESC = Equivalent series capacitance
ESR = Equivalent series resistance
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 13
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Co Re L
Tolerance limits of the rated capacitance must be taken into account when calculating this value.
Impedance (Z)
Impedance of an electrolytic capacitor results from a circuit formed by the following individual equivalent series
components:
Co Re L
Ce
Co = Aluminum oxide capacitance (surface and thickness of the dielectric.)
Re = Resistance of electrolyte and paper mixture (other resistances not depending on the frequency are not considered: tabs,
plates, etc.)
Ce = Electrolyte soaked paper capacitance.
L = Inductive reactance of the capacitor winding and terminals.
Impedance of an electrolytic capacitor is not a constant quantity that retains its value under all conditions; it changes
depending on frequency and temperature.
Impedance as a function of frequency (sinusoidal waveform) for a certain temperature can be represented as follows:
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 14
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Z [ohm ]
1,000
100
ω Ce
1/ω
10 B
Re ωL
A
1
1/ω
ω Co
C
0.1
0.1 1 10 100 1,000 10,000
F [K Hz]
• Capacitive reactance predominates at low frequencies.
• With increasing frequency, capacitive reactance Xc = 1/ωCo decreases until it reaches the order of magnitude of
electrolyte resistance Re(A)
• At even higher frequencies, resistance of the electrolyte predominates: Z = Re (A - B)
• When the capacitor’s resonance frequency is reached (ω0), capacitive and inductive reactance mutually cancel each other
1/ωCe = ωL, ω0 = 1/SQR(LCe)
• Above this frequency, inductive reactance of the winding and its terminals (XL = Z = ωL) becomes effective and leads to
an increase in impedance
Generally speaking, it can be estimated that Ce ≈ 0.01 Co.
Impedance as a function of frequency (sinusoidal waveform) for different temperature values can be represented as follows
(typical values):
Z (ohm)
10 µF
1,000
100
-40°C
10 20°C
85°C
1
0.1
0.1 1 10 100 1,000 10,000
F (K H z)
Re is the most temperature-dependent component of an electrolytic capacitor equivalent circuit. Electrolyte resistivity will
decrease if temperature rises.
In order to obtain a low impedance value throughout the temperature range, Re must be as little as possible. However, Re
values that are too low indicate a very aggressive electrolyte, resulting in a shorter life of the electrolytic capacitor at high
temperatures. A compromise must be reached.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 15
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
A high leakage current fl ows after applying voltage to the capacitor then decreases in a few minutes, for example, after
prolonged storage without any applied voltage. In the course of continuous operation, the leakage current will decrease and
reach an almost constant value.
After a voltage-free storage the oxide layer may deteriorate, especially at a high temperature. Since there are no leakage
currents to transport oxygen ions to the anode, the oxide layer is not regenerated. The result is that a higher than normal
leakage current will fl ow when voltage is applied after prolonged storage.
As the oxide layer is regenerated in use, the leakage current will gradually decrease to its normal level.
The relationship between the leakage current and voltage applied at constant temperature can be shown schematically as
follows:
VR VS VF V
Where:
VF = Forming voltage
If this level is exceeded, a large quantity of heat and gas will be generated and the capacitor could be damaged.
VR = Rated voltage
This level represents the top of the linear part of the curve.
VS = Surge voltage
This lies between VR and VF. The capacitor can be subjected to VS for short periods only.
Electrolytic capacitors are subjected to a reforming process before acceptance testing. The purpose of this preconditioning
is to ensure that the same initial conditions are maintained when comparing different products.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 16
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 17
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Packaging Quantities
Bulk Auto-insertion
Size Diameter Length
Code (mm) (mm) Standard
Cut Leads Ammo Tape & Reel
Leads
C3 5.0 11.0 10,000 15,000 2,000 2,600
E3 6.3 11.0 10,000 15,000 2,000 2,200
G3 8.0 11.0 6,000 8,000 1,000 1,500
G4 8.0 15.0 5,000 5,000 1,000 1,500
G7 8.0 14.0 5,000 5,000 1,000 1,500
H9 10.0 12.5 4,000 4,000 700 1,200
H1 10.0 12.0 4,000 4,000 700 1,200
H2 10.0 15.0 3,000 4,000 700 1,200
H4 10.0 20.0 2,400 3,000 700 1,200
L2 13.0 16.0 2,400 2,400 500
L3 13.0 20.0 2,000 2,000 500
L4 13.0 25.0 1,600 1,600 500
M7 16.0 25.0 1,000 500 300
M1 16.0 26.0 1,000 500 300
M2 16.0 32.0 800 500 300
M3 16.0 36.0 600 500 300
M4 16.0 40.0 600 500 300
N5 18.0 25.0 800 500 300
N1 18.0 32.0 500 500
N2 18.0 36.0 500 500
N3 18.0 40.0 500 500
Q3 22.0 35.0 400 400
Q4 22.0 40.0 300 400
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 18
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Marking
KEMET Logo
Polarity Stripe (−)
Rated Capacitance
Rated Voltage
(VDC)
Date Code Series, Rated
Month*/Year* Temperature
Manufacturing
Internal Codes
*Y = Year
Code 01 02 03 04 05 06 07 08 09
Year 2011 2012 2013 2014 2015 2016 2017 2018 2019
*M = Month
Code 01 02 03 04 05 06 07 08 09 10 11 12
Month 1 2 3 4 5 6 7 8 9 10 11 12
Construction
Aluminum Can
Insulating Sleeve
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 19
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
D D
L L
W2
H H
W2
H0
H0
W1
W1
t t
W0
W
W0
W
P0 D0
d P0 D0
Mounting tape
d Mounting tape
Adhesive tape
Adhesive tape
W2
H
W2
W1
W1
t t
W0
W
W0
W
I
P0 D0
P0 d
D0 Mounting tape
d Mounting tape Adhesive tape
Adhesive tape
Dimensions
D L p d P P0 P1 P2 W W0 W1 W2 H0 H1 I D0 t
(mm)
Tolerance +0.5 +0.8/−0.2 ±0.05 ±1.0 ±0.3 ±0.7 ±1.3 +1/−0.5 ±0.5 Maximum Maximum ±0.75 ±0.5 Maximum ±0.2 ±0.2
4 5–7 2.5 0.45 12.7 12.7 5.1 6.35 18 12 11 3 16.0 18.5 4 0.7
Formed to
≤7 2.5 0.45 12.7 12.7 5.1 6.35 18 12 11 3 16.0 18.5 4 0.7
2.5 mm 5
>7 2.5 0.50 12.7 12.7 5.1 6.35 18 12 11 3 16.0 18.5 4 0.7
4 5–7 5.0 0.45 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
≤7 5.0 0.45 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
5
>7 5.0 0.50 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
Formed to
≤7 5.0 0.50 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
5 mm 6
>7 5.0 0.50 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
≤7 5.0 0.50 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
8
>7 5.0 0.50 12.7 12.7 3.85 6.35 18 12 11 3 16.0 18.5 4 0.7
4 5–7 1.5 0.45 12.7 12.7 5.6 6.35 18 12 11 3 18.5 4 0.7
≤7 2.0 0.45 12.7 12.7 5.35 6.35 18 12 11 3 18.5 4 0.7
5
>7 2.0 0.50 12.7 12.7 5.35 6.35 18 12 11 3 18.5 4 0.7
≤7 2.5 0.50 12.7 12.7 5.1 6.35 18 12 11 3 18.5 4 0.7
Straight leads 6
>7 2.5 0.50 12.7 12.7 5.1 6.35 18 12 11 3 18.5 4 0.7
≤7 3.5 0.50 12.7 12.7 4.6 6.35 18 12 11 3 18.5 4 0.7
8
>7 3.5 0.50 12.7 12.7 4.6 6.35 18 12 11 3 18.5 4 0.7
10 ≤ 20 5.0 0.60 12.7 12.7 3.85 6.35 18 12 11 3 18.5 1 4 1.0
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 20
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
D H
H
W
W
T
Ammo Reel
Diameter Length H W T D H W
Maximum Maximum ±2 ±0.5 +1/−0.1
4 All 230 340 42
5 ≤7 230 340 42
5 11 275 340 42
6.3 ≤7 235 340 45
6.3 11 230 340 48
8 ≤7 270 340 48
8 11 235 340 48
350 30 50
8 >11 ≤ 20 240 340 57
10 ≤ 13 250 340 52
10 >13 ≤ 20 256 340 57
10 >20 250 340 60
12 All 270 340 57
13 All 285 340 62
16 All 265 340 62
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 21
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Construction Data
The manufacturing process begins with the anode foil being
electrochemically etched to increase the surface area and then
“formed” to produce the aluminum oxide layer. Both the anode and Extended cathode
cathode foils are then interleaved with absorbent paper and wound
into a cylinder. During the winding process, aluminum tabs are Anode foil
attached to each foil to provide the electrical contact.
The deck, complete with terminals, is attached to the tabs and then Foil tabs
folded down to rest on top of the winding. The complete winding
is impregnated with electrolyte before being housed in a suitable
container, usually an aluminum can, and sealed. Throughout the
Tissues
process, all materials inside the housing must be maintained at the
highest purity and be compatible with the electrolyte. Cathode foil
Each capacitor is aged and tested before being sleeved and packed.
The purpose of aging is to repair any damage in the oxide layer Etching
and thus reduce the leakage current to a very low level. Aging is
normally carried out at the rated temperature of the capacitor and
Forming
is accomplished by applying voltage to the device while carefully
controlling the supply current. The process may take several hours to
complete. Winding
Electrical: Mechanical/Visual:
• Leakage current • Overall dimensions Sleeving
• Capacitance • Torque test of mounting stud
• ESR • Print detail
Packing
• Impedance • Box labels
• Tan Delta • Packaging, including packed
quantity
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 22
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Single-Ended Aluminum Electrolytic Capacitors – ESK, +85°C
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes
no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury
or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4004_ESK • 3/11/2020 23
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Mouser Electronics
Authorized Distributor
KEMET:
ESK107M025AE3EA ESK477M063AL4EA ESK107M050AG3AA ESK228M025AL4EA ESK106M063AC3AA
ESK107M025AE3AA ESK107M035AE3AA ESK108M025AH4AA ESK228M025AL4AA ESK228M035AM7AA
ESK106M350AH2AA ESK108M016AH2AA ESK108M6R3AG3AA ESK107M025AC3AA ESK226M050AC3AA
ESK106M050AC3AA ESK107M063AH1EA ESK108M025AH4EA ESK227M025AG3EA ESK337M050AH4AA
ESK477M035AH2EA ESK478M025AN2AA ESK108M035AL3AA ESK476M035AC3AA ESK225M100AC3AA
ESK105M050AC3AA ESK478M035AN2AA ESK474M100AC3FA ESK106M016AC3AA ESK225M100AC3FA
ESK107M6R3AC3AA ESK106M350AH2EA ESK106M035AC3AA ESK105M100AC3FA ESK226M016AC3AA
ESK107M050AG3EA ESK475M100AC3FA ESK335M100AC3AA ESK106M063AC3FA ESK227M063AH2AA
ESK477M6R3AE3AA ESK226M025AC3AA ESK476M035AC3EA ESK106M400AH2EA ESK226M050AC3FA
ESK226M063AE3AA ESK107M016AC3AA ESK107M010AC3AA ESK105M250AE3AA ESK476M025AC3FA
ESK106M100AE3EA ESK477M050AH4EA ESK226M050AC3EA ESK335M050AC3AA ESK475M100AC3AA
ESK107M025AC3EA ESK476M050AE3EA ESK227M063AH2EA ESK226M400AL4AA ESK476M100AH1AA
ESK478M025AM2AA ESK106M050AC3DA ESK477M035AH2AA ESK477M050AH4AA ESK338M016AL4AA
ESK478M050AQ4AA ESK107M016AE3AA ESK336M025AC3AA ESK477M010AE3AA ESK105M100AC3AA
ESK478M6R3AL3AA ESK475M050AC3AA ESK226M100AE3AA ESK337M016AG3AA ESK476M025AC3AA
ESK228M035AM2AA ESK226M250AH4AA ESK476M100AH2AA ESK227M100AL4AA ESK478M010AL4AA
ESK337M025AH1AA ESK476M200AL3AA ESK338M6R3AL3AA ESK227M010AC3AA ESK476M016AC3AA
ESK227M050AH2AA ESK106M160AG3AA ESK107M450AQ4AA ESK107M063AG3AA ESK478M050AQ3AA
ESK477M025AH2AA ESK228M016AL4AA ESK109M025AQ4AA ESK227M016AG3DA ESK336M450AM3AA
ESK227M6R3AC3AA ESK105M400AG3AA ESK337M035AH2AA ESK226M450AM7AA ESK226M010AC3AA