Example 2 (Steel Frame Structure Modeling) : Staad-Pro V8i Example 2
Example 2 (Steel Frame Structure Modeling) : Staad-Pro V8i Example 2
Internal hinge
Pin support
Fixed support
Fixed support Roller support
Roller support
Edit the modeling commands of steel frame structure, where steel member
section as follows:
1. Frame columns W6X15
2. Truss frame (vertical C8X13)
3. Horizontal in x and z direction W8X21at level y = 6m)
4. Horizontal in z direction double C10X30 at level y = 7m and y =8m)
5. External inclined double angle L3X2X3/16)
6. Internal inclined angle L2.5X2X3/8)
7. Roof thickness 3cm
Page 1 of 6
UNIVERSITY OF TECHNOLOGY
(Building & Construction Engineering Department)
Staad-Pro V8i Example 2 2016 - 2017 by: Prof. Dr. Nabeel Al-Bayati
SOLUTION:
Frame Idealizations (Beams and Columns)
Hinge
At Z = 0 At Z = 4m
Hinge
At Z = 8m At Z = 12m
Page 2 of 6
UNIVERSITY OF TECHNOLOGY
(Building & Construction Engineering Department)
Staad-Pro V8i Example 2 2016 - 2017 by: Prof. Dr. Nabeel Al-Bayati
At y = 6m
At y = 7m
Page 3 of 6
UNIVERSITY OF TECHNOLOGY
(Building & Construction Engineering Department)
Staad-Pro V8i Example 2 2016 - 2017 by: Prof. Dr. Nabeel Al-Bayati
At y = 8m
Page 4 of 6
UNIVERSITY OF TECHNOLOGY
(Building & Construction Engineering Department)
Staad-Pro V8i Example 2 2016 - 2017 by: Prof. Dr. Nabeel Al-Bayati
Page 5 of 6
UNIVERSITY OF TECHNOLOGY
(Building & Construction Engineering Department)
Staad-Pro V8i Example 2 2016 - 2017 by: Prof. Dr. Nabeel Al-Bayati
************************************************
*Define plate s section
ELEMENT PROPERTY
85 TO 96 THICKNESS 0.03
************************************************
*Define Truss members which resisted only axial loads
MEMBER TRUSS
7 TO 10 14 15 22 TO 25 29 30 37 TO 40 44 45 52 TO 55 59 60
************************************************
MEMBER RELEASES
17 32 START MZ
20 35 END MZ
************************************************
*Define Materials Properties
CONSTANTS
E STEEL ALL
DEN STEEL ALL
POI STEEL ALL
ALPHA STEEL ALL
************************************************
*Define Support Type
SUPPORTS
1 TO 31 BY 10 FIXED
17 27 PINNED
7 37 FIXED BUT FX FZ MX MZ
FINISH
Page 6 of 6