Alcatel 4400 Quick Reference Commands
Alcatel 4400 Quick Reference Commands
com/2008/06/17/alcatel-4400-quick-reference-commands/
Here’s some reference commands for an Alcatel-Lucent OmniPCX, I just want to share with
you, and also because i’m always forgot something that i’ve learned. :hammer:
ADDRESSING MODES
- By index >tabeqt
HARDWARE MAINTENANCE
RESOURCES MAINTENANCE
- All coupler’s status >config
NETWORK MAINTENANCE
INCIDENTS
DECT (PWT)
- Put out of service a DECT Base station outserv ‘bs’ cr cpl bs_nbr
- Put out of service a DECT ADPCM Block >outserv ‘dsp’ cr cpl dsp_nbr
DATA BASE
ACCOUNTING
OTHER COMMANDS
APPLICATION
ENTITIES
PILOT
QUEUE
PROCESSING GROUP
AGENT
RULES
DISTRIBUTION
TRUNK-GROUP TRUNK
DIALOG CONTEXT
CSTA
STATISTIC PILOT
Share this:
Share
Related
Post navigation
← BBM Naik Lagi? Hiks…
Telephone Numbers 1 (International) →
1.
3.
Weedew, yang dah jadi Voip Engineer. Lo blm makan2 tuh Bull. Kapan dong, gw
tungguin yah. Voip yang gw tau buat nge PadLock ext.nya cewe2 cakep. Trus ntar dia
tlp gw deh minta dibukain PadLocknya. Hehee..
4.
@Pak Onay
huahahaa.. Ampun pak onay, saya masih beginner!
5.
6.
@kumis
nyang mane mis??? ke kosan aja.
7.
8.
@dzuwi
Wahh gw juga lagi ngawinin alcatel sama cisco nih (*Ngeles dikit).
Kalo keberatan ya jgn diangkut sekaligus mbak, mabok ntar. Ajarin dd dong Data
mining nya… yah yah yah?
9.
Bul mantap neh dah gaewe? BtW basih kost di kapuk? (gw mo numpang mandi klo lg
nginep di benkel) “Hueheheheh…..
10.
@semua
Mau nanya. Coupler state pbx gue ngehang di Z24_2 INIT 1 nih, padahal yang
dicolok itu Z24. Gimana ya?
Tolong. Trims!
11.
@toxicbrother
1. Pastikan board z24_2 sudah di create terlebih dahulu. Shelf>Board>Consult
Modify/Create
2. Coba lepas board z24_2 (jangan ditancap) dulu, sampai Board CPU6/CPU7, INTIP
(jika ada), juga CPU redundant (kalo ada) statusnya Ready alias In Service. Jika
sudah ‘In Service’, baru tancapkan itu board z24_2 dan tunggu hingga kondisi In
Service
Kalo sudah in service, coba cek status trunk (trkstat) untuk koneksi analog/digital yg
sudah terkoneksi. Pastikan untuk tiap extention statusnya F (Free) atau B (Busy), jika
ada yg hs (nah ini baru hang namanya) :P reset board dengan rscpl. CMIIW
12.
13.
@pak onay
hs itu (kalo di pabx) artinya out of service, kalo kepanjangannya apa gue jg gak tau
persis nay. Tapi kalo inget mata kuliah sistem digital yg materinya multiplexer (kalo
gak salah ya), hs itu kondisi signal clock saat berada di zero level (mudah2an
bener…). CMIIW lagi ah..
14.
15.
superboy April 3, 2009 at 5:24 PM Reply
16.
@superboy
Yohaiii…ilmu jgn disimpen,gak guna nantinya.
btw, ini masternya alcatel nih :p (thx for coming)
17.
ada yg tahu cara break bios di cpu6 ? karena ketika load tdk ada bios proses….
Mas ahmad,
Saat CPU6 ataupun Call Server load pertama kali (detect hardware), tunggu
hingga muncul pesan di display:
Semoga membantu.
18.
Misi mas,,,
mau nanya…
biasanya kan kalo IP phone urutannya IP PBX -> Switch -> IP Phone
nah itu kan yg lewat paket eth…
kalo misalkan end nya Analog Phone dengan topologi yang sama kira2 apa ya yg
dimofikasi??
mohon bantuannya soalnya lagi ngawinin ALcatel dengan Produk perangkat aktif :D
19.
mas anggri,
Analog phone tidak bisa dikoneksikan dengan switch, analog phone dikoneksikan
dengan media MDF/LSA yang di jumper ke IP PBX. PBX Alcatel nya tipe apa yah
mas? kalau tipe crystal keluaran dari board eZ32 (analog phone extension), eUA32
(digital phone extension), NDDI (PSTN Telkom), atau NPRAE (ISDN)
diterminasikan ke MDF lalu di jumper ke terminasi extension yang berasal dari area
(handset). Sama halnya dengan Alcatel tipe Media Gateway (MG) yang dikoneksikan
dengan output dari board pada port2 SLI (analog extension), UAI (digital extension),
APA (PSTN), dll.
20.
1.Mas tuk trunk group d pabx itu, digunakan dlm kondisi apa aja seh?
2. Terus maksud “follow me” PABX itu gimana? krn ada yg definisikan beda2
3. Cara buat “number+pause+extension”, gmana tuh? bisa kasih pembelajarannya.
4.mohon share ya mas..
21.
gembuls February 15, 2011 at 8:52 PM Reply
Mas Rexy,
Sebelumnya, PABX yang digunakan merk apa yah? saya coba jawab yah
1. Trunk digunakan (logikanya) untuk pencabangan dari satu menjadi banyak atau
sebaliknya banyak dijadikan satu, maksudnya satu output untuk beberapa input atau
satu input untuk beberapa output. kalau digunakan untuk PABX, misalnya: satu line
PSTN digunakan secara bersama-sama untuk beberapa line extension, begitu
sebaliknya satu line extension untuk outgoing call nya menggunakan banyak nomor
PSTN yang berbeda secara bergantian, yang di define dalam satu trunk.
2. “Follow Me” sama halnya dengan forward line, artinya jika ada incoming call ke
suatu extension yang di set fitur “Follow Me” tersebut, maka PABX akan mem-
forward (mengalihkan) ke nomor tujuan yang di set (misal: nomor Handphone).
3. Saya kurang paham dengan pertanyaan yang di maksud, maksudnya untuk buat
speed dial ke nomor extension atau bagaimana yah? kalau maksudnya seperti itu,
pertama harus diaktifkan dulu fitur DTMF nya di sisi PABX, untuk ‘pause’ ini sendiri
prefix nya berbeda-beda pada sisi si penelfon, kalau dari handphone ada yang
menggunakan ‘*’ (bintang), ‘,’ (koma), untuk beberapa tipe ada yang menggunakan
huruf ‘P’. jadi kita bisa menyimpan speed dial dengan format number+’pause’
prefix+extension
4. Kalau kurang jelas dengan jawaban saya, tanya lagi yah…berarti saya yang salah
tangkap maksud pertanyaan nya,hehehe….
22.
mau tanya dong, kalau misalnya buat user yg banyak sekaligus atau menghapus user
banyak sekaligus gimana ya? apa ada command linenya? saya rencana mau
menghapus user dan membuat forward massal.
Pake release berapa mas? kalau pake release dibawah R9.1 coba dengan web
interface 4760.
1. aktifkan web interface 4760
mgr —> system –> system parameters –> Use of 4760 –> True (abis ini restart
pabx dulu)
2. lalu akses di browser dengan menggunakan alamat IP dari OmniPCX, pilih
configuration.
23.
someone would have some manual command line since I have installed the onmivista
thank you very much
Hi Jorge,
as far as I know, there is no CLI on OmniVista.
24.
gan ane mnta bantuannya, ane kmren setting ip PABX Alcatel-lucent tapi ane lupa
ipnya, tau g cara bkin pabxnya biar balik ke setting defaultnya? kl0 tau tolong bales
ke [email protected]
bisa dilihat dimari gan –> How to reset OXE default password
tapi ini kan untuk rubah password jd default, kl0 rubah ipnya jd default
gmn?
oh iya, sorry salah baca. untuk rubah IP Address, bisa ganti dengan
command:
#netadmin
atau bisa juga menggunakan linux command: ifconfig
dengan login menggunakan serial console
jadi harus lewat linux y gan? kl0 lwt wndows? trus kabel consolenya
dipasang dibagian mana di pabxnya kan banyak tu portnya
25.
26.
Hi, Gembuls
Hi Sergei,
you can use this command:
# siteid
look at the cpu type, cpu6 or cpu7 is for alcatel omnipcx 4400 (crystal) and
cpu8 or later is for alcatel omnipcx enterprise (media gateway)
27.
Hi Sergei,
I think it’s not possible (I don’t know exactly), because PBX it doesn’t same
with switches/router device. but if you’re using an Alcatel OmniPCX you can
export your configuration to text file, using 4760 web interface.
28.
Pak.. Mau tanya dong.. cara setting timer di alcatel pabx.. supaya extension 1 dapat
telp keluar 10 menit extension 2 dapat telp keluar 15 menit dimana yah kalau lewat
mgr?
Terima kasih
o
gembuls June 26, 2012 at 10:22 AM Reply
Pak Alex,
timer di alcatel pbx berlaku untuk keseluruhan system. dan bisa di apply pada
extension tertentu.
1. Set Timer:
System -> Go down hierarchy -> Timer -> 260 -> 100 (by default)
rubah sesuai yang dibutuhkan satuan waktu milliseconds
done.
29.
Hi Jorge,
# telnet xxx.xxx.xxx.xxx
just telnet the IP Address from your PC to the remote device, simple like that.
can you explain more detail about the question?
to set a hotline, you can configure hunting group which have a member from
user extensions.
30.
Hi, Gembuls,
your help is highly appreciated. Frankly speaking, we mostly or even have to use the
telnet interface, but not the web one.
In this respect, do you probably know anything about the request “rack_table cr 0″
that can be sent to Alcatel PBX through telnet terminal?
The point here is that by this method we can get some PBX config information.
Among the parameters we get, there are the following:
Crystal rack_type : s14_slots
Crystal rack_fict : TRUE
…,
So, the question here is “Can we possibly figure out what exactly the type of the rack
is on the basis of the “Crystal rack_type” parameter?” For example,
In terms of “s14_slots” we cannot be sure what exactly the rack type it is. Might you
know what the rack type it is? Common or crystal hardware?
Crystal 0 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 0 | 6 | CPU_CS|———- | IN SERVICE | NO PCMS CODE |
| 0 | 10 | CPU_CS|———- | REG NOT INIT | NO PCMS CODE |
+——————————————————————-+
Crystal 2 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 2 | 0 | GD|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 2 | SLI 16(Z)|———- | IN SERVICE | NO PCMS CODE |
| 2 | 3 | UAI 8|———- | IN SERVICE | NO PCMS CODE |
| 2 | 4 | PRA T2|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 5 | SLI 16(Z)|———- |ONLY OPS FILE | BAD PCMS CODE |
| 2 | 8 | CS|———- | CALL SERVER | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|002 | 00 -GD (INT_HS ) -X- -X- ( INT_HS) MEX – 00 |003 |
|————————————————————————-|
|002 | 00 -GD (MAIN ) — 8/8 — ( INT_A) INTIP3A – 01 |019 |
|————————————————————————-|
Crystal 3 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 3 | 0 | MEX|———- | REG NOT INIT | NO PCMS CODE |
| 3 | 1 | GA|———- |ONLY OPS FILE | BAD PCMS CODE |
| 3 | 3 | GA|———- |ONLY OPS FILE | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|003 | 00 – MEX (INT_HS ) -X- -X- ( INT_HS) MGD – 00 |002 |
|————————————————————————-|
Crystal 19 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 19 | 0 | FICTIF| | REG NOT INIT | NO PCMS CODE |
| 19 | 1 | INTIP3A| | IN SERVICE | NO PCMS CODE |
| 19 | 2 | INTIP3A| | OUT OF SERV | NO PCMS CODE |
| 19 | 3 | Z_FICTIF| | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
Hi Sergei,
Yeah I’m prefer to use telnet or via console rather than using web interface to
configure. Based on the ‘config all’ outputs, that’s a common hardware or
Media Gateway Large Type.
Because in Media Gateway Large there is CS (Call Server) board and also GD
(Gateway Driver) board, both of them used for call processing, that is an easy
way to recognize from the hardware types (look at Crystal 2).
On Media Gateway Large (3U) there is 9 available boards, Media Gateway
Medium (2U) there is 6 available boards, and for Media Gateway Small (1U)
there is 3 available boards per-unit/shelf. there is Call Server (CS) and
Gateway Driver (GD) boards on each. If you have an extended shelf (look at
the Crystal 3), it’s using MEX board connected to the GD’s Module port to
communicate the other boards (on crystal 3) to the CS board.
Cristal 0 :
+————————————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|——————–|———–|——————|—————————|
| 0 | 0 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 1 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 2 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 3 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 4 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 5 | GPA |———- | IN SERVICE | 3BA53097AAAA02 |
| 0 | 6 | CPU6 |———- | IN SERVICE | NO PCMS CODE |
| 0 | 7 | PRA2 |———- | IN SERVICE | 3BA23076AABD01 |
| 0 | 8 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 9 | NPRAE |———- | IN SERVICE | 3BA23254AAAD03 |
| 0 | 10 | NDDI2 |———- | IN SERVICE | 3BA23171AAAD04 |
| 0 | 11 | NDDI2 |———- | IN SERVICE | 3BA23171AAAD04 |
| 0 | 12 | eUA32 |———- | IN SERVICE | 3BA23266AAAA02 |
| 0 | 13 | UA32 |———- | IN SERVICE | 3BA53050ABBC01 |
| 0 | 14 | Z24 |———- | IN SERVICE | 3BA53065AFBA02 |
| 0 | 15 | INTOF2A |———- | IN SERVICE | 3BA23260AAAB04 |
| 0 | 16 | BRA2 |———- | IN SERVICE | 3BA23073ABAC03 |
| 0 | 17 | NPRAE |———- | IN SERVICE | 3BA23254AAAD03 |
| 0 | 18 | NDDI |———- | IN SERVICE | 3BA53095AWBC02 |
| 0 | 19 | NDDI |———- | IN SERVICE | 3BA53095AWBC02 |
| 0 | 20 | CPU6 |———- | IN SERVICE | BAD PCMS CODE |
| 0 | 21 | Z24 |———- | IN SERVICE | 3BA53065AFBA02 |
| 0 | 22 | eZ32 |———- | IN SERVICE | 3BA23265ABCB04 |
| 0 | 23 | eZ32 |———- | IN SERVICE | 3BA23265ABBB01 |
| 0 | 24 | NPRAE |———- | IN SERVICE | 3BA23254AAAD04 |
| 0 | 25 | eZ32 |———- | IN SERVICE | BAD PCMS CODE |
| 0 | 26 | Z24_2 |———- | IN SERVICE | 3BA53065NAAG02 |
| 0 | 27 | INTIPA | INT-IP | IN SERVICE | 3BA23193ACAF06 |
+—————————————————————————————-+
31.
So, one more little question. What does it mean: “s14_slots” in “Crystal rack_type”
for crystal 0?
it doesn’t necessary while you recongnize via rack_table command but based
on your output from ‘config all’ commands, that you are using media gateway
type. You can identifying by physical board appearance and what type of
board which is created on configuration, simple like that.
32.
om gembul, kalau pengen menambahkan extension baru gimana cara di pabx nya
alcatel
o
gembuls July 24, 2012 at 9:44 PM Reply
33.
On my OmniPCX 4000 I can call to numbers starting with 2,5,7, but here in my
country some new cellphones starts with the number 3, and my pbx is restricted to not
dial numbers starting with 3, where can I change this so I can be able to dial numbers
starting with the number 3?…. thank you
Hi Rodrigo,
You can setup dial numbers at ‘Discriminator Rule’ menu, from Translator –>
Numbering Plan –> Discriminator Rule
this configuration relates to the Access Categories/Public Network Categories,
Automatic Route Selection (ARS), User Extensions Configuration, and
Entities.
34.
this is alcatel forum?I am alcatel 4400 expert , contact me if you have question or
looking for technical friend , me too
[email protected]
o
no dude, this is not alcatel forum. i’m using this blogs just for knowledge
sharing
Hi, how to check how many analog , digital extensions used in the system and
how many are free? and what is the total capacity of the sytem
35.
36.
Hi,
I am trying to figure out what Shelf and Board number my PCM board is located at in
the system. Is that information available trough the CLI? Any help is appreciated.
Hi Brian,
as oxeman4400 wrote below, you can use ‘config’ command:
for example:
# config 0 (for shelf 0)
# config 1 (for shelf 1)
and so on..
37.
38.
Mas Hari,
cara mudahnya:
– lewat handset, by default dengan prefix: #*0 (feature –> set in/out services)
untuk merelease/disable extension.
– angkat handset, tekan extension yang diinginkan jumlah digit sesuai
numbering, setelah itu masukkan secret code: 0000 (by default)
Makasih mas atas infonya pertanyaan lagi mis no ext 103 rusak( digital
) lalu no ext 222 ( analog) mau saya rubah menjadi 103 bisa tidak
mas ?
Bisa mas, tinggal di swap port nya aja. karena port analog dengan
digital berbeda dan card nya pun juga beda.
Cara gampangnya:
1. Release port pada extension 103 dan 222 dengan prefix #*0 (by
default). Setelah di release begitu angkat handset voice guide akan
meminta anda memasukkan nomor extension.
2. Aktivasi extension di handset ext. 222 tadi lalu masukkan extension
baru 103
39.
You can change phone set type from digital to analog or otherwise
analog to digital via mgr menu:
1. Telnet/console to PBX, using CLI command: mgr
2. Users –> Consult/modify User Extension –> Change ‘Set Type’
option to correct phone
3. Change Shelf address, Board Address, and Equipment Address
parameters depends on your phone plugged into (manual). or another
way you can change port parameters (shelf, board, and equipment
address) on extension 222 into ‘255’ with prefix set in/out service
(#*0), then you activate your extension on the phone set with new
extension 103.
notes:
– if you can not change or swap your extension from digital to analog,
change phone set type to 4035T first, set all equipment address (shelf,
board, equipment) to ‘255’ to release then you can change it to
analog/digital.
– another way but not recommended: delete user extension 103 and
222 and then recreate it with new Set Type :D
40.
Hi Gembul,
Need to know howto trace/setting routing auto attendant from trunk. Use OXO 4400
gr command.
Thanks
Create Virtual extension first and Import the wave file in AA menu , Please
give landing group same as virtual extension.
41.
bos mau tanya cara setting pabx omni alcatel gimna ya?
Bagian mana yang mau disetting bos? apakah bisa lebih spesific?
42.
Hi How To check the Licenses in 4400 OXE System, any particular cmd?
o
gembuls March 14, 2013 at 4:56 PM Reply
How many hardware ports are available? and how many of them are in
use and total licenses used in system . If i select choice 2 , i ‘m nt able
to find out his
Hi shankar,
in OXE, license is binding on software not on hardware.
using command: config 1 2 (1 is shelf number, and 2 is board number)
43.
How the integration of Voicemail 4645/4635 in 4400 and Common hardware and also
how to config to users.
I need ur email ID
44.
I hope this is common hardware system. But what is crystal 0 , 1,2,3,4, etc. what is No
PCMS code and Bad PCMS code and also what is that inter crystal topology?
Please expain me this configuration in details, then easy to comapre with other site
details.
Crystal 0 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 0 | 6 | CPU_CS2|———- | IN SERVICE | NO PCMS CODE |
| 0 | 10 | CPU_CS2|———- | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
Crystal 1 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 1 | 0 | UA_FICTIF| | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
Crystal 2 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 2 | 0 | GD3|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 2 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 3 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 4 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 6 | DPNSS|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 7 | PRA T2|———- | IN SERVICE | BAD PCMS CODE |
| 2 | 8 | CS2|———- | CALL SERVER | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|002 | 00 -GD3 (INT_A ) === 77/78 === ( MAIN) pwMEX – 00 |004 |
|————————————————————————-|
|002 | 00 -GD3 (INT_A ) === 78/78 === ( MAIN) pwMEX – 00 |005 |
|————————————————————————-|
|002 | 00 -GD3 (MAIN ) — 26/26 — ( INT_A) INTIP3A – 01 |019 |
|————————————————————————-|
Crystal 3 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 3 | 0 | GD3|———- | IN SERVICE | BAD PCMS CODE |
| 3 | 2 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 3 | 3 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 3 | 4 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 3 | 6 | PRA T2|———- | IN SERVICE | BAD PCMS CODE |
| 3 | 7 | PRA T2|———- | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|003 | 00 -GD3 (INT_A ) === 78/78 === ( MAIN) pwMEX – 00 |006 |
|————————————————————————-|
|003 | 00 -GD3 (MAIN ) — 26/26 — ( INT_A) INTIP3A – 01 |019 |
|————————————————————————-|
Crystal 4 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 4 | 0 | pwMEX|———- | IN SERVICE | NO PCMS CODE |
| 4 | 1 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 4 | 2 | APPLI|———- | LANX 16_1 | BAD PCMS CODE |
| 4 | 3 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 4 | 4 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 4 | 8 | SLI2 8 (Z)|———- | IN SERVICE | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|004 | 00 -pwMEX (MAIN ) — 77/78 — ( INT_A) MGD3 – 00 |002 |
|————————————————————————-|
Crystal 5 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 5 | 0 | pwMEX|———- | IN SERVICE | NO PCMS CODE |
| 5 | 1 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 5 | 2 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 5 | 4 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 5 | 5 | SLI2 16(Z)|———- | IN SERVICE | BAD PCMS CODE |
| 5 | 8 | SLI2 16(Z)|———- | IN SERVICE | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|005 | 00 -pwMEX (MAIN ) — 78/78 — ( INT_A) MGD3 – 00 |002 |
|————————————————————————-|
Crystal 6 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 6 | 0 | pwMEX|———- | IN SERVICE | NO PCMS CODE |
| 6 | 1 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 6 | 2 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 6 | 3 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
| 6 | 4 | UAI 16|———- | IN SERVICE | BAD PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|006 | 00 -pwMEX (MAIN ) — 78/78 — ( INT_A) MGD3 – 00 |003 |
|————————————————————————-|
Crystal 18 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 18 | 0 | GD|———- | IN SERVICE | BAD PCMS CODE |
| 18 | 1 | 4645|———- | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|018 | 00 -GD (MAIN ) — 24/24 — ( INT_A) INTIP3A – 01 |019 |
|————————————————————————-|
Crystal 19 :
+——————————————————————-+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|—-|—-|————|———–|————–|—————–|
| 19 | 0 | FICTIF| | REG NOT INIT | NO PCMS CODE |
| 19 | 1 | INTIP3A| | IN SERVICE | NO PCMS CODE |
| 19 | 2 | INTIP3A| | OUT OF SERV | NO PCMS CODE |
| 19 | 3 | Z_FICTIF| | IN SERVICE | NO PCMS CODE |
+——————————————————————-+
+————————————————————————-+
| CR | CPL Type Role Free/Tot Role Type CPL | CR |
|————————————————————————-|
|019 | 01 -INTIP3A (INT_A ) === 26/26 === ( MAIN) GD3 – 00 |002 |
|————————————————————————-|
|019 | 01 -INTIP3A (INT_A ) === 26/26 === ( MAIN) GD3 – 00 |003 |
|————————————————————————-|
|019 | 01 -INTIP3A (INT_A ) === 24/24 === ( MAIN) GD – 00 |018 |
|————————————————————————-|
45.
Hi gembuls , Is there any update about my query. Please can you expalin me asap.
46.
hi shankar,
bad pcms code means that you are not using the correct license or maybe
you’re using open license. crystal number is a shelf number in this case you
are using 6 shelfs, shelf 0, 2,3,4,5, and 6
what is your query dude? I’m sorry for late of reply, I’m just a blogger not an
alcatel supports. you can contact an alcatel support center via alcatel business
partner.
47.
Hi Gembuls, how to check how many analog , digital extensions used in the system
and how many are free? and what is the total capacity of the sytem
o
hi shankar,
you can check it with command: spadmin
choose no.2 and here you can see what features you were use with license
availability.
I.e: Analog Phones 65/1000 (65 means your analog phones were used, 1000
means your license capabilities.
48.
Hi, Thanks, I already tried that command, but it is not showing analog, digital and IP
parameter. and sorry i’m disturbing you, i’m a new learner for OXE and
49.
Hi,
This is regarding the SNMP configuration fro Alcatel 4400 System for R
8.01 and also I refered R 8. Document.
50.
hi shankar,
51.
Hi Gembuls, Thanks for the information, one more clarification is required, if you
delete any config in DDI Default config menu, how to check again, what was the their
in previous config
Can u please suggest me for this.
52.
Hi Gembuls,
Saya ingin memasang VOIP system baru, tapi PBX lama (Lucent) tetap digunakan
sebagai backup kalo terjadi failure di VOIP. Apakah hal ini bisa dilakukan? Dan
bagaimana caranya?
Terima kasih atas bantuannya
o
bisa pak, Interconnect antar pabx dengan analog line bisa menggunakan
Tieline, cara lainnya dengan menggunakan SIP Trunk: http://bit.ly/16wwRly
53.
Hi gembuls,
to enable trunk, you can create trunk configuration and then apply it using
ARS. for detail reads the manual configuration of alcatel-lucent omnipcx
54.
Hi gembus,
How to view the backup file of OXE/4400 system ( Mao file ) in offline. Just want to
check the what are all the things is configured on it. ( in OXO , backup we can load
and view in OMC software)
55.
Mas Gembul, bagaimana carnya untuk mengeset operational states pada board di
alcatel 4400 (OXE)?
di ‘create’ dulu mas board nya setelah shelf nya ter-create. Menu MGR >
Shelf > Board > Create > Pilih board sesuai dengan tipe board yang dipasang.
56.
Pak mau tanya, hari ini saya tidak bisa telnet ke pabx alcatel 4400 saya, ping ke IP
nya pun tidak bisa. Sebelumnya lancar. Apa yang salah yah? Terima kasih.
coba cek koneksi physical dari pabx ke network nya dulu pak, kalo gak ada
masalah coba cek konfigurasi ip di pabx.
57.
58.
Selamat Pagi Pak, pagi ini saya coba restart PABX nya dan telnet sudah bisa. Terima
kasih.
59.
hi gembuls i am new about this pabx oxe …why when i try to modify the directory
name of a user is not changing even i save the changes through f1 to save when i
verify it still the old name is there? i apreciate your help. thanks
60.
Pak, hari ini saya telnet ke PABX, waktu ketik MGR keluar error :
error : error 13 : parse error
error : error 13 : parse error
panic : internal error, file “/twdhs3/prodc1/ws/si_c17/,ao/code/resdico.c”, line 71
61.
o
gembuls April 3, 2014 at 6:15 PM Reply
yes, of course. you can record a conversation via voice mail (omnipcx), or use
third-party appliance, for example: omnipcx record suite :)
62.
hi guys…
I want if it is possible to know how make a release on the hard disk of the cpu6 of
omnipcx4400.
best regards.
yes it’s posibble, release cpu6 board from it shelf then loose the screw on hard
disk.
63.
hi guys…
i want to know how to download database on empty hard disk of cpu6 of omnipcx
4400 pabx .
best regards.
which databases you want to download if the hard disk was empty?
if you want to download the databases:
1. backup your databases first (if you need the latest databases)
2. connect to pbx with FTP connection
3. download backup file from directory: DHS3Dyn\BACKUP\IMMED
– retrive the file which you want to backup from IMMED directory based on
name of file
64.
hi guys….
I want to know how to download a software release of my database which was backed
up on the hard disk of cpu6 to make this database active.
thank you
hi sarah, you can do the backup-restore procedure via swinst, choose no.2
(expert mode) then choose no.4 (Backup & Restore Operations). after you
backup the databases you can download that file using FTP
65.
hi guys..
how can i know the system version(release) and if i have any problem in this issue
how can i behave.
thank you.
66.
67.
mantab gan ilmu sharenya semaga jadi orang yg bijaksana .alloh berkati agan amin
68.
mohon maaf kalau mau jualan bukan disini tempatnya, silahkan buka lapak di
tempat lain ya…
69.
Hi,
Gembuls/Arif Romansyah
Terima kAsih
license di ALU itu cuma satu pak, ya file OPS itu. untuk menambah license
SIP Phone ataupun IP Phone coba contact vendor/business partner ALU,
karena itu di generate sesuai kebutuhan (ada harga pastinya) dan mengikat ke
CPU-ID.
untuk cek license dan cek fitur apa saja yang available, bisa gunakan
command: spadmin
70.
Hi, I have some problems with the time setting on OXE. The systhem take into
account the modification of the date but the extensions not. Can you help me?
would you like to describe the details? do you have changed time & date via
swinst?
71.
Alex October 15, 2014 at 3:02 PM Reply
Hi all there, i try to figure out why i cannot apply changes when i manage my
database with mgr. Someone could help me on this matter?
did you login with mtcl user? apply/save config with ctrl + v
72.
I did. For example when I’m on the consult/mofify: Dynamic State User. I put the
directory number in the where box, I hit ENTER key but nothing happens. Weird
not using enter to confirm but use hold Ctrl button on your keyboard + v
73.
Yes I did
Leave a Reply
https://gembuls.wordpress.com/category/telecommunication/
As your request my friends, I want to share about restoring the ‘root’ and ‘mtcl’ password to
default on Alcatel-Lucent OmniPCX if you have lost it.
1. From terminal console, Reboot OmniPCX into single user mode using Grub. at the boot
prompt, hold on boot process and then press ‘e’ (without quote) to edit the kernel line from
default boot configuration.
2. Select cursor to the kernel, by default system will load the kernel from /boot/vmlinux
directory and root directory location was on /dev/hda5. and then press ‘e’ once again to edit
the parameters.
5. In this step you will boot into single user mode and you can change the password of root
and mtcl. at the prompt enter this command:
# passwd (this will change the 'root' password)
# passwd mtcl (this will change the 'mtcl' password)
after you set up the root and mtcl password, reboot your system with command:
# shutdown -r 0
1. Same step with OXE, interrupt boot loader by hold any key on this section:
2. Edit boot loader configuration, please press ‘c’ to edit boot parameter with command line
in this section:
4. System will booting to single user mode, change the root and mtcl password using this
command:
after you set up the root and mtcl password, reboot your system with command:
# shutdown -r 0
done!
remark: you must change the root and mtcl default password to securing your system
Share this:
Share
Related
How to Install Asterisk-GUIIn "Telecommunication"
Post navigation
← Active Directory Recycle Bin
Untuk Dirimu, Calon Pengantinku →
1.
hi
actually I tried your mentioned structure on CS common hardware R9130148 but after
single boot I get ” inter your root maintenance password or cntrol+d ” after giving
root password I log in in root account and I change my mtcl account but after normal
boot I could not log in with new password ….
any idea ??please share your experience.
also admin do you have any idea about RADIUS SERVER on oxe?
thanks again
hi expert,
so, you didn’t have any experience about this right? how come you called
yourself as an expert? (i’m sorry just kidding….. :D) refer to your question:
1. Can you explain to me by email about what you have done while resetting
your password and what a release used with a screenshot?
2. Hmm…Radius server on OXE? it’s interesting, but….what for? can you tell
me the main concept?
hi thank you .
I am expert and I am not GOD (about your sentence :-) i’m sorry just
kidding).
I will send screenshot ASAP and also will describe my issue about
RADIUS server in email.
for comfort and for god sake forget about “expert ” , I am technical
person.
2.
3.
Jacob Peled February 13, 2014 at 7:10 PM Reply
Seems that it a solution for old systems. you are not getting the prompt through which
you can enter the command “passwd” . You are getting a message:
Now if you know the root password in order to get into the …# prompt. You can do it
in the normal way anyway. I mean let the system boot, and get into it by the root user,
and change the “mtcl” user’s password.
Bottom line if you change the Root password, and don’t know what it is – You are in
deep deep trouble.
4.
That was very helpful, thanks very much, but my only problem now is that when the
system reboots is reboot in grub mode every time.
It doesn’t go on to boot in Linux mode. Please help me.
Leave a Reply