Multiload II Modbus PDF
Multiload II Modbus PDF
Sent:(FPOWERUP) Received:(000)
logmsg_queued bit is set
Modbus:
Fn=0x06, Write 0 to Register 7012
Upload the driver number and any other additional information to be included with stored BOL in Multiload
Sent:(U95000004504) Received: (0T1)
Sent:(U9510001234) Received: (0T1)
Sent:(U952 ) Received: (0T1)
Sent:(U953 ) Received: (0T1)
Sent:(U954 ) Received: (0T1)
Modbus:
Fn=0x16, Write data to Registers 2700 … 2724
Fn=0x16, Write data to Registers 2725 … 2749
Fn=0x16, Write data to Registers 2750 … 2774
Fn=0x16, Write data to Registers 2775 … 2799
Fn=0x16, Write data to Registers 2800 … 2824
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
0000)
Sent:(R112001) Received:
(0001120010000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
0000)
Sent:(R112002) Received:
(0001120020000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
0000)
Sent:(R112003) Received:
(0001120030000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
0000)
Sent:(R112004) Received:
(0001120040000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
0000)
Modbus:
Fn=0x03, Read Registers 3000 … 3006 (Preset Gross Totalizers)
Fn=0x03, Read Registers 3144 … 3191 (Component Gross Totalizers)
Fn=0x03, Read Registers 3336 … 3432 (Additive Gross Totalizers)
Etc…
Upload selected recipe definitions into index in range of 001-019 (recommend using preset number as index).
Sent:(U5000010001100Regular Unlead RUL
02010000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000) Received: (0a1)
Modbus:
Fn=0x06, Write Index 1 to Register 2200
Fn=0x16, Write Recipe Data to Registers 2201 … 2267
Authorize preset for batch indicating volume and recipe definition index.
Sent:(MAM000100100000100000) Received: (0T1)
Modbus:
Fn=0x16, Write Authorization Data (1, 0, 1000, 1, 1) to Registers 7500 … 7504
Chapter 8 – Communication Trace Example 170
Wait until preset state is PRESET_END_OF_BATCH and pick up totals (with MRS) and/or totalizers.
Sent:(MRS000) Received:
(0T1RS000001107970000000001000000001000+0022400000000001000+00224000000000+0000000000000
0+00000000000000+00000000000000+00000000000000+00000000000000+00000000000000+000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
000000000000000000000000000000000000000000000000)
Modbus:
Fn=0x03, Read Registers 4060 … 4067 (Preset Gross Volumes)
Chapter 8 – Communication Trace Example 171
When preset state returns to PRESET_IDLE, prompting for next batch can begin again.
A transaction can be ended by MultiLoad (Driver pulls card) or from the Host with a MET command
And uncleared batched will be set to end batch waiting for the host to acknowledge with a MEB command to
clear totals.
When all presets have been cleared, RCU status will go to TRANSACTION_DONE.
Sent:(Q) Received: (0D0C238)
Modbus:
Fn=0x03, Read Register 7000