DS-BT Relays
DS-BT Relays
4,000 V BREAKDOWN
VOLTAGE DS RELAYS
DS-BT
RELAYS
FEATURES
20.65 10.65 •4,000 V breakdown voltage
.813 .419
•Reinforced insulation between coil and contacts
10.5
.413 •Surge voltage withstand: 1500 V FCC Parts 68
mm inch
SPECIFICATIONS
Contact Characteristics
Arrangement 2 Form C 2 Form D Arrangement 2 Form C 2 Form D
Initial contact resistance, max. Max. operating speed 60 cpm at rated load
50 mΩ
(By voltage drop 6 V DC 1 A) Initial insulation resistance*1 Min. 100 MΩ (at 500 V DC)
Contact material Gold-clad silver 750 Vrms 500 Vrms
Initial Between open contacts
Nominal switching capacity 2 A 30 V DC 1 A 30 V DC break- for 1 min. for 1 min.
Rating Max. switching power 60 W, 125 VA 30 W, 62.5 VA down Between contacts and coil 4,000 Vrms for 1 min.
(resistive Max. switching voltage 220 V DC, 250 V AC voltage*2 Between contacts sets 750 V 500 V
load) Max. switching current 2A 1A FCC surge voltage between open
1,500 V
Min. switching capacity**1 10 µA 10 mV DC contacts
Electrical Mechanical (at 180 cpm) 2×107 106 Operate time*3 (at nominal volt-
Approx. 3 ms
life (min. age)
ope.) Electrical (at 20 cpm) 2×105 Release time (without diode)*3
Approx. 2 ms
**1 This value can change due to the switching frequency, environmental (at nominal voltage)
conditions, and desired reliability level, therefore it is recommended to Temperature rise Max. 65°C
check this with the actual load. 10 to 55 Hz
Functional*4
Coil Vibration at double amplitude of 3.3 mm
resistance 10 to 55 Hz
Arrangement 2 Form C 2 Form D Destruction*5
at double amplitude of 5 mm
Nominal operating power 360 mW 540 mW
Shock Functional*6 Min. 294 m/s2 (30 G)
Remarks resistance Destruction Min. 980 m/s2 (100 G)
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section Conditions for oper- Ambient –40°C to +70°C –40°C to +60°C
*2 Detection current: 10mA ation, transport and temp. –40°F to +158°F –40°F to +140°F
*3 Excluding contact bounce time storage*7
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs (Not freezing and
*5 Half-wave pulse of sine wave: 6ms condensing at low Humidity 5 to 85%R.H.
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
temperature)
AMBIENT ENVIRONMENT (Page 61) Unit weight Approx. 4.0 g 0.14 oz
192
DS-BT
TYPES AND COIL DATA (at 20°C 68°F)
1) 2 Form C type
Pick-up Drop-out Nominal operating Coil Nominal Max. allowable
Operating Coil voltage,
Part No. voltage, voltage, current, resistance, operating voltage, V DC
function V DC
V DC (max.) V DC (min.) mA (±10%) Ω (±10%) power, mW (at 50°C 122°F)
DSBT2-S-DC1.5V 1.5 1.125 0.15 240 6.25 1.95
DSBT2-S-DC3V 3 2.25 0.3 120 25 3.9
DSBT2-S-DC5V 5 3.75 0.5 72 69.4 6.5
Single side
DSBT2-S-DC6V 6 4.5 0.6 60 100 360 7.8
stable
DSBT2-S-DC9V 9 6.75 0.9 40 225 11.7
DSBT2-S-DC12V 12 9 1.2 30 400 15.6
DSBT2-S-DC24V 24 18 2.4 15 1,600 31.2
2) 2 Form D type
Pick-up Drop-out Nominal operating Coil Nominal Max. allowable
Operating Coil voltage,
Part No. voltage, voltage, current, resistance, operating voltage, V DC
function V DC
V DC (max.) V DC (min.) mA (±10%) Ω (±10%) power, mW (at 50°C 122°F)
DSBT2-M-2D-DC1.5V 1.5 1.125 0.15 360 4.2 1.8
DSBT2-M-2D-DC3V 3 2.25 0.3 180 16.7 3.6
DSBT2-M-2D-DC5V 5 3.75 0.5 108 46.3 6
Single side
DSBT2-M-2D-DC6V 6 4.5 0.6 90 66.7 540 7.2
stable
DSBT2-M-2D-DC9V 9 6.75 0.9 60 150 10.8
DSBT2-M-2D-DC12V 12 9 1.2 45 266.7 14.4
DSBT2-M-2D-DC24V 24 18 2.4 22.5 1,066.7 28.8
Note: Standard packing Tube: 25 pcs. Case: 1,000 pcs.
DIMENSIONS mm inch
PC board pattern (Bottom view)
20.65 10.65
.813 .419 8-0.9 dia.
8-.035 dia.
10.50
.413
9.9 7.62 7.82
.390 .300 .308
REFERENCE DATA
1. Mechanical life test Change of pick-up and drop-out voltage Change of contact resistance
Tested sample: DSBT2-S-DC5V, 10 pcs.
Pick-up/drop-out voltage, V DC
4
Pick-up voltage Max. 100
–
x
Min.
3
Max.
Max.
–
x
–
x
2 Drop-out voltage
Max. Min.
– Min.
x 10
1
Min.
0 0
0 10 100 1000 0 10 100 1000
No. of operations, × 104 No. of operations, × 104
193
DS-BT
2. Electrical life test (resistive)
Tested sample: DSBT2-S-DC12V, 6 pcs.
Condition: 2 A 30 V DC resistive load, 30 cpm 7 100
Pick-up/drop-out voltage, V DC
Pick-up voltage N.C. contact
Circuit Max.
Contact resistance, mΩ
6 – N.O. contact
x
Min.
5
N.O.:
30 V DC No.11–13 Max.
N.C.: 4 –
x
No. 4–6 Max.
–
x
3 Min.
Drop-out voltage 10 Min.
Max.
–
2 x
Min.
1
0 5 10 15 20 0 5 10 15 20
No. of operations, × 104 No. of operations, × 104
80 Coil
Coil temperature rise, °C
70 6
N.O. contact
2A
1A T1: Operate time 5
Operate time, ms
0A T1
60 T2 T2: Operate bounce
Coil time
4
50
3
40 N.C. contact
2
T3: Release time
T3
30 T4 T4: Release bounce
time 1
1.5 6 1.5
5
Measured terminals: 9-13
1.0 4 1.0
Specified value: Less than 3.75 V DC Specified value: More than 0.50 V DC 40 Mean: AC 5169 V
– 3.22 V DC
Mean value (x): –– 1.65 V DC
Mean value (x): Max.: AC 5800 V
Max.: 3.69 V DC Max.: 2.23 V DC Min.: AC 4700 V
Min.: 2.65 V DC Min.: 0.78 V DC
30
20 20
Quantity
Quantity
Quantity
20
10 10
10
0
2.0 2.5 3.0 3.5 4.0 4.5 5.0 0 0.5 1.0 1.5 2.0 2.5 3.0 AC 4000 AC 5000 AC 6000
Pick-up voltage, V Drop-out voltage, V Breakdown voltage, V AC
194
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
This datasheet has been downloaded from:
www.DatasheetCatalog.com