Shading of The PV System - Effects and Measures: Fronius International GMBH Froniusplatz 1, 4600 Wels
Shading of The PV System - Effects and Measures: Fronius International GMBH Froniusplatz 1, 4600 Wels
Dirt
Snow
Chimneys
Trees
Cables
LESS YIELD
LATER „RETURN ON
INVESTMENT“ (ROI)
5
Fronius International GmbH / Verschattung der PV-Anlage - Auswirkungen und Maßnahmen
Good planning helps to
reduce the effects of
shading!
6 Fronius International GmbH / Verschattung der PV-Anlage - Auswirkungen und Maßnahmen
WHAT HAPPENS IF THERE IS SHADING?
7,5
E=800W/m²
6,0
E=600W/m²
- high irradiation, high current
/ Only minimum changes in voltage
4,5
1,5
/ If no shading existent:
/ Diode is inactive
/ If shading existent:
/ Diode is active
/ Effect:
/ Minimize losses
/ Module string is hardly affected
/ "Bottleneck effect" is minimized
/ Protects against damage to the shaded cells
120 half-cells
6*20 half-cells connected in
60-72 cells parallel / 0% power / 50% power
3 or more bypass diods (each 2*20 half-cells are (e.g.: sliding snow)
connected to a bypass diode)
12 Fronius International GmbH / Verschattung der PV-Anlage - Auswirkungen und Maßnahmen
Second basic rule:
Wechselrichter
plugs
Optimizer
61 instead of 21 MC4 plugs PV Modules
21 Fronius International GmbH / Shading of the PV system - effects and measures
STRING INVERTERS VS. DC OPTIMIZER
YIELD COMPARISON*
22 *Assc. Prof. Dr. W.-Toke Franke. 2020. The Impact of Optimizers for PV-Modules - A comparative study. University of Southern Denmark Fronius International GmbH / Leistungselektronik auf Modulebene
STRING INVERTERS VS. DC OPTIMIZER
YIELD COMPARISON
Additional yield with string inverter system taking all the different scenarios into
account!!
Good system planning and the greatest possible avoidance of shading is the
most important point!