One Way Slab Design
One Way Slab Design
Load Calculations:
Dead load of the slab = 3.125 kN/m2
Floor Finish on the slab = 2.0 kN/m2
Total Dead load on the slab,wd = 5.125 kN/m2
Total Live load on the slab,wl = 1.50 kN/m2
Ast(reqd) =
f ck
2fy [ √ Mu
1− 1−4 .598 2
bd f ck
. bd
]
60.91 mm2
Required percentage of steel, pt = 100Ast/b.d
= 0.12 %
It is greater than minimum percentage of steel, 0.12%
Limiting percentage of steel for U.R.S.,pt limit = 19.94 x fck/fy
= 1.20 %
Hence the section is Under reinforced section
Dia.Of bar used for +ve reinforcement = 8 mm
Spacing of the bars,Sv = (b x Asv) /Ast 335.10 mm
say 200.00 mm
Minimum spacing required = 3.d = 300.00 mm Whichever is less
300.00 mm
Provide T8 @ 200 C/C as +ve reinforcement
Provided percentage of steel = 0.25 %
Distribution reinforcement:
Minimum percentage of steel = 0.12 %
Area of steel required, Ast(dist) = 621.15 mm2
Dia.Of bar used for dist. Reinforcement = 8 mm
Spacing of the bars,Sv=(bxAsv) /Ast(dist)= 414.73 mm
say 250.00 mm
Minimum spacing required = 5.d = 500.00 mm Whichever is less
300.00 mm
Provide T8 @ 250 C/C as distribution reinforcement
(leff/d)basic = 20
Percentage of tensile reinforcement = 0.25 %
Modification factor for Tension rein.Kt = 1.28 (From IS:456)
Modification factor for Comp. rein.Kc = 1.00 (From IS:456)
(leff/d)Max. = (leff/d)basic * Kt * Kc = 25.60
(leff/d)provided = 14.51 < (leff/d)max
Hence Provided depth is adequate.
Load Calculations:
Dead load of the slab = 3.125 kN/m2
Floor Finish on the slab = 1.0 kN/m2
Total Dead load on the slab,wd = 4.125 kN/m2
Total Live load on the slab,wl = 15.00 kN/m2
Ast(reqd) =
f ck
2fy [ √ Mu
1− 1−4 .598 2
bd f ck
. bd
]
128.32 mm2
Required percentage of steel, pt = 100Ast/b.d
= 0.12 %
It is greater than minimum percentage of steel, 0.12%
Limiting percentage of steel for U.R.S.,pt limit = 19.94 x fck/fy
= 1.20 %
Hence the section is Under reinforced section
Dia.Of bar used for +ve reinforcement = 8 mm
Spacing of the bars,Sv = (b x Asv) /Ast 335.10 mm
say 200.00 mm
Minimum spacing required = 3.d = 300.00 mm Whichever is less
300.00 mm
Provide T8 @ 200 C/C as +ve reinforcement
Provided percentage of steel = 0.25 %
Distribution reinforcement:
Minimum percentage of steel = 0.12 %
Area of steel required, Ast(dist) = 649.026 mm2
Dia.Of bar used for dist. Reinforcement = 8 mm
Spacing of the bars,Sv=(bxAsv) /Ast(dist)= 414.73 mm
say 200.00 mm
Minimum spacing required = 5.d = 500.00 mm Whichever is less
300.00 mm
Provide T8 @ 200 C/C as distribution reinforcement
(leff/d)basic = 26
Percentage of tensile reinforcement = 0.25 %
Modification factor for Tension rein.Kt = 1.28 (From IS:456)
Modification factor for Comp. rein.Kc = 1.00 (From IS:456)
(leff/d)Max. = (leff/d)basic * Kt * Kc = 33.28
(leff/d)provided = 15.59 < (leff/d)max
Hence Provided depth is adequate.