1. The document details the design of a two-way reinforced concrete slab for a three storey residence. 2. Key properties of the slab include spans of 2.95m and 2.2m, a thickness of 125mm, and rebar diameters of 12mm. 3. The design loads, moments, and flexural reinforcement are calculated according to design code requirements. 4. Reinforcement along both spans consists of #12 bars spaced at 300mm with temperature bars of #10 bars at 300mm.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

Structural Analysis Template

1. The document details the design of a two-way reinforced concrete slab for a three storey residence. 2. Key properties of the slab include spans of 2.95m and 2.2m, a thickness of 125mm, and rebar diameters of 12mm. 3. The design loads, moments, and flexural reinforcement are calculated according to design code requirements. 4. Reinforcement along both spans consists of #12 bars spaced at 300mm with temperature bars of #10 bars at 300mm.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project: PROPOSED THREE STOREY RESIDENCE

Client:
Location:
Job No. Designed By: JRCM Checked By:
Subject S1 Date: 11/26/2016 Date:
DESIGN OF TWO WAY SLAB AS PER NSCP 2010
Input

Material Properties

f'c = 20.7 MPa Concrete Compressive Strength


fys = 275 MPa Reinforcing Bar Yield Strength, Along S-Direction
fyl = 275 MPa Reinforcing Bar Yield Strength, Along L-Direction

Slab Properties
Ln = 2.95 m Long Span length
Sn = 2.2 m Short Span length
h = 125 mm Slab Thickness
dbl = 12 mm Bar diameter Along L-Direction
dbs = 12 mm Bar diameter Along S-Direction

Loading Data
DL = 2.9375 kPa Dead Load (Self Weight)
SD = 4.12 kPa Super Imposed Dead Load
LL = 1.9 kPa Live Load

Support Condition
Case: 9

Note: Hatch Lines means continuous .


Output:
1. Check short span to long span ratio
Sn/Ln = 0.75 0.74576 > =0.5, hence Two-Way Slab
2. Minimum slab thickness
hmin = 57.22222 mm < h =125, O.K.
3. Compute design loads
Factored Dead Load = 1.2 {D + SD}= 8.47 kPa
Factored Live Load = 1.6LL = 3.04 kPa

Wu = 11.509 kPa

4. Determine design moment


Along Short direction
a. Moment @ discontinuous end = 1.09 kN - m
b. Moment @ midspan = 2.43 kN - m
c. Moment @ continuous edge = 4.34 kN - m

Along Long - direction


a. Moment @ discontinuous end = 0.35 kN - m
b. Moment @ midspan = 0.88 kN - m
c. Moment @ continuous edge = 1.4 kN - m

5. Flexural Design
Along Short Direction
a. @ Discontinuous end b. @ Midspan b. @ Continuous edge
Mu = 1.09 kN-m Mu = 2.43 kN-m Mu = 4.34 kN-m
d = 99.00 mm d = 99.00 mm d = 99.00 mm
Rn = 0.12 Mpa Rn = 0.28 Mpa Rn = 0.49 Mpa
p = 0.0004 p = 0.0010 p = 0.0018
p(min) = 0.0020 p(min) = 0.0020 p(min) = 0.0020
As = 198.00 mm^2 As = 198.00 mm^2 As = 198.00 mm^2
Sp = 300.00 mm.o.c. Sp = 300.00 mm.o.c. Sp = 300.00 mm.o.c.
Sp (t) = 300.00 mm.o.c. Sp (t) = 300.00 mm.o.c. Sp (t) = 300.00 mm.o.c.
Along Long Direction
a. @ Discontinuous end b. @ Midspan b. @ Continuous edge
Mu = 0.35 kN-m Mu = 0.88 kN-m Mu = 1.40 kN-m
d = 87.00 mm d = 87.00 mm d = 87.00 mm
Rn = 0.05 Mpa Rn = 0.13 Mpa Rn = 0.21 Mpa
p = 0.0002 p = 0.0005 p = 0.0008
p(min) = 0.0020 mm^2 p(min) = 0.0020 mm^2 p(min) = 0.0020 mm^2
As = 174.00 mm^2 As = 174.00 mm^2 As = 174.00 mm^2
Sp = 300.00 mm.o.c. Sp = 300.00 mm.o.c. Sp = 300.00 mm.o.c.
Sp (t) = 300.00 mm.o.c. Sp (t) = 300.00 mm.o.c. Sp (t) = 300.00 mm.o.c.

Design Summary:

Along Short Direction Along Long Direction


Steel @ Discontinuous edge: Ø 12 @ 300 mm. o.c. Steel @ Discontinuous edge: Ø 12 @ 300 mm. o.c.
Steel @ Midspan: Ø 12 @ 300 mm. o.c. Steel @ Midspan: Ø 12 @ 300 mm. o.c.
Steel @ Continuous Edge: Ø 12 @ 300 mm. o.c. Steel @ Continuous Edge: Ø 12 @ 300 mm. o.c.

Temperature Bars: Ø 10 mm @300mm.oc