LCD Display Panel: - 2-Stage Charger Design

This document provides a summary of key features for the OnlineUPS product line from 1KVA to 10KVA models. It includes details on true double-conversion technology, wide input voltage range, programmable power management outlets, LCD display, and optional features like hot standby mode and isolation transformers. The summary highlights the benefits of clean power, high efficiency, flexible battery options, and communications features for monitoring and maintenance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views3 pages

LCD Display Panel: - 2-Stage Charger Design

This document provides a summary of key features for the OnlineUPS product line from 1KVA to 10KVA models. It includes details on true double-conversion technology, wide input voltage range, programmable power management outlets, LCD display, and optional features like hot standby mode and isolation transformers. The summary highlights the benefits of clean power, high efficiency, flexible battery options, and communications features for monitoring and maintenance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

OnlineUPS

LCD Display Panel

ONLI NE UPS
• True double-conversion online UPS • Smart battery charger design to optimize
Atrue doubleconversionUPSwill provide clean,high level quality battery performance
power to fully protect mission-critical devicessuch assensitive . TitanPro1-3Kseries isequipped with 2-stage charger design
networks,small computer centers,servers,telecomapplications,as to guarantee battery discharge time.Besides,it will adjust
well asfor industrial applications. charging voltage according to outside temperature.This
• Output power factor 0.9 featureswill extend the useful service life of batteries.
. TitanPro 6Kand up models are equipped with 3-stage
Compared to the onlineUPSsinthe current market,TitanProseries extendable charger for optimized battery performance.
providesbetter output power factor up to 0.9.It offershigher This feature extends the useful service life of batteries and
performanceand efficiencyfor critical applications. optimizes battery recharge time. Besides, the extendable
• Wide input voltage range (110 V -300 V) charger design can be stacked in numbers for large-capacity
battery charging.
TitanPro can still provide stable power to connected devicesunder

•Maintenance bypass available for 6K and up


unstablepower environments.

• Programmable power management outlets models


With programmable power
Internal bypassassurescontinuouspowerto critical devices
managementoutlets,userscan easilyand
during UPSmaintenance.
independently control load segments.
During power failure,this featureenables
usersto extend battery time to mission-
•OptionalhotstandbymodeandN+Xparallel
criticaldevicesby shutting down the redundancyavailablefor6Kandupmodels
For genuinely redundant power protection, TitanPro(6K and up
non-criticaldevices. Programmable Outlets(P1)
- connect to non-criticaldevices
models) can either be used in parallel operation with up to 3
unitsorhot standbymode.SlaveUPSwill backup the load in the
event of criticalcomponent failure.It increasespower safetyand
• 50/60 Hz Frequency Converter Mode availability.
Lockoutput frequencyat 50Hzor 60Hzto suit power sensitive
equipments.
•Adjustable battery numbers for 6K and up
models
• ECO mode operation for energy saving TitanPro(6Kandup models)canstill normaloperatewell with only
Offersefficiencyashigh as97%to cut energyusage&cost. UPS 18or 19internal batteries.
power application via static bypass,timely returning to online
doubleconversionwhen the need arises. • Built-in isolation transformer (Option)
With built-in isolation
• Emergency Power Off (EPO) Function transformer, theUPSwill
Thisfeature can securethe personnel and equipment in caseof offer full isolation and
firesor otheremergencies. complete common mode

• SNMP+USB+RS-232 multiplecommunications noise rejection for connected


preciousequipment.It
for 1-3K models become an ideal power
Thisfeatureallowseither USBorRS-232communication port to source with 100% protection
work with SNMPinterfacesimultaneously. against unexpected AC power

•DSP technology applied for 6K and up models


problems.

A DSP controller providesan improved and cost-effective


solution with high performance.
OnlineUPS

1KVA/1.5KVA/2KVA/3KVA/6KVA/10KVA Online UPS Selection Guide


MODEL TitanPro 1K (L) TitanPro 1.5K (L) TitanPro 2K (L) TitanPro 3K (L) Titan Pro 6K (L) Titan Pro 10K (L)
PHASE Single phase with ground
CAPACITY 1000 VA/900W 1500 VA/1350W 2000 VA/1800W 3000 VA/2700W 6000 VA/5400W 10000VA/9000W
INPUT
Nominal Voltage 200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VAC
55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50%load 110-300 VAC at 50% load
Voltage Range 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load 176-300 VAC at 100% load
Frequency Range 40 Hz ~ 70 Hz 46 ~ 54 Hz or 56 ~ 64Hz
ONLI NE UPS

Power Factor ≧ 0.99 @ Nominal Voltage (100% Load) ≧0.99 @ 100%Load


OUTPUT
Output Voltage 200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1% ± 1%
FrequencyRange(SynchronizedRange) 47~53 Hz or 57~63 Hz 46 ~ 54 Hz or 56 ~ 64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ±0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 3:1
≦ 2 % THD ( Linear Load) ≦ 3 % THD (Linear Load)
Harmonic Distortion
≦ 4 % THD (Non-linear Load) ≦ 6 % THD (Non-linear Load)
Transfer AC Mode to Batt. Mode Zero
Time Inverter to Bypass 4 ms (Typical) Zero
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 87% 90% 89%
Battery Mode 83% 87% 88%
BATTERY
Battery Type 12 V / 7Ah 12 V / 9Ah 12 V / 7Ah 12 V / 9Ah 12 V / 7Ah 12 V / 9Ah
Numbers 3 3 6 6 20 20
Standard Typical Recharge Time 7 hours recoverto 9 hours recoverto
4 hours recover to 90% capacity
Model 90% capacity 90% capacity
Charging Current (max.) 1.0 A 1.0 A
Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% 273.0 VDC ±1%
Battery Type Depending on applications Depending on applications
Long-run Numbers 3 3 6 6 18-20
Model Charging Current (max.) 8.0 A 4.0 A
Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% 273.0 VDC ±1%
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Dimension,DxWxH(mm) 397 x 145 x 220 421 x 190 x 318 592 x 250 x 576
Model Net Weight (kgs) 13 14 26 28 81 83
Long-run Dimension,Dx W x H(mm) 397 x 145 x 220 421 x 190 x 318 592 x 250 x 576
Model Net Weight (kgs) 7 7 13 13 25 27
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 50dB@1Meter Less than 55dB@1Meter Less than 58dB@1Meter
MANAGEMENT
Smart RS-232
Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, andMAC
USB
Optional SNMP Power management from SNMP manager and web browser
*Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100VAC,200VAC or 208 VAC.
** L means long-run model

Tower Battery Pack (Optional built-in charger)


Capacity (VA) 1K/1.5K 2K/3K
Battery Type 12 V 7 Ah 12 V 9 Ah 12 V 7 Ah 12 V 9 Ah 12 V 7 Ah 12 V 9 Ah
Battery Number 6pcs 6 pcs 16 pcs 16 pcs 18 pcs 18 pcs
Dimension (DxWxH) mm 397 x 145 x 220 535 x 190 x 318 535 x 190 x 318
Net Weight (kgs) 18 20 49.4 55.3 60.9 67.5
Capacity (VA) 6K/10K
Battery Type 12 V 7 Ah 12 V 9 Ah 12 V 7 Ah 12 V 9 Ah 12 V 7 Ah 12 V 9 Ah
Battery Number 40 pcs 40 pcs 60 pcs 60 pcs 80 pcs 80 pcs
Dimension (DxWxH) mm 592 x 250 x 576 830 x 250 x 576 815 x 250 x 826
Net Weight (kgs) 109 125 166 190 210 242
* There are several battery options for Titan Pro 2K/3K/6K/10K. Please check the above table for the detailed dimensions.

Cel/WhatsApp : 955035523
Tel.Fijo : 01 224-3975 / 01 637-8101
Dirección : Calle Marchand N°558 San Borja, Lima
E-mail : [email protected]
Web : www.centralionperu.com
OnlineUPS

Rack Battery Pack


Form Factor 2U 3U

Capacity (VA) 1K 1K / 1.5K 2K 2K / 3K 6K/10K

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah

Battery Number 4 pcs 6 pcs 8 pcs 12 pcs 20 pcs 20 pcs


UPS

Dimension
(DxWxH)mm 380 x 438 x 88 480 x 438 x 88 600 x 438 x 88 580 X 438 X 131

Net Weight (kgs) 16.9 21.3 28.7 40.8 57 65


ONLI NE

Software
ViewPower - UPS ManagementSoftware
* Allowscontrolandmonitoringof multipleUPSsviaLANand INTERNET
* User-friendly poweranalysisgraphs
* Real-timedynamicgraphsof UPSdata
* SafelyOSshutdownandprotectionfrom datalossduring power failure
* Warningnotificationsviaaudiblealarm,broadcast,mobilemessenger,ande-mail
* ScheduledUPSon/off,batterytest,programmableoutletcontrol,andaudiblealarmcontrol
* Passwordsecurityprotectionandremoteaccessmanagement
* SupportsmultipleOSandlocallanguages

Accessory
Remote Control Agent
SNMP Card

* Allowscontrolandmonitoringof multipleUPSsthroughRJ-45networkconnection
* Real-timedynamicgraphsof UPSdata(voltage,frequency,loadlevel,batterylevel)
* Warning notificationsviaaudible alarm,broadcast,mobilemessenger,e-mail and SNMPtraps
* Historicdata log stored in centralized PCdatabase
* Simplefirmware upgrade with one click
* Password security protection and remoteaccessmanagement
* Supportsoptional environmental monitoring detector for temperature,humidity and smoke
* 2-year product warranty

AS-400 Card

* Capableof selecting the statusof the dry-contact signal by setting jumper to meet different
application requirements.
* Suitable applications:IBM Server,Personal PC& Workstationsequipments,Auto-controlled
industrial equipment & communication applications

9-pin interface RS-232 interface

Rackmount Slider PDU & Maintenance Bypass Switch External Maintenance Bypass Switch
Simple installation for
mounting Titan Pro Rack
in your server rack
enclosure.
Automatic Transfer Switch(ATS)

Cel/WhatsApp : 955035523
Tel.Fijo : 01 224-3975 / 01 637-8101
Dirección : Calle Marchand N°558 San Borja, Lima