0% found this document useful (0 votes)
50 views

Laboratory Manual Basic Electrical Engineering Laboratory

This document outlines the laboratory manual for the Basic Electrical Engineering course at Jorhat Engineering College in Assam, India. It provides instructions on laboratory conduct, including arriving prepared and on time, maintaining cleanliness, handling equipment carefully, and obtaining daily signatures. It also lists 8 experiments on topics like calibrating measurement devices, verifying circuit theorems, and measuring power and power factor in resistor-inductor circuits using various methods. Students are to complete the listed experiments, record their results, and have their work checked and graded.

Uploaded by

prathap kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views

Laboratory Manual Basic Electrical Engineering Laboratory

This document outlines the laboratory manual for the Basic Electrical Engineering course at Jorhat Engineering College in Assam, India. It provides instructions on laboratory conduct, including arriving prepared and on time, maintaining cleanliness, handling equipment carefully, and obtaining daily signatures. It also lists 8 experiments on topics like calibrating measurement devices, verifying circuit theorems, and measuring power and power factor in resistor-inductor circuits using various methods. Students are to complete the listed experiments, record their results, and have their work checked and graded.

Uploaded by

prathap kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

LABORATORY MANUAL

Basic Electrical Engineering


Laboratory

Department of Instrumentation Engineering


JORHAT ENGINEERING COLLEGE
Assam-785007
Do’s
Ø Be punctual, maintain discipline & silence.
Ø Keep the Laboratory clean and tidy.
Ø Leave your shoes in the rack outside.
Ø Handle the equipment carefully.
Ø Save all your files properly.
Ø Come prepared with programs/algorithms/related manuals.
Ø Follow the procedure that has been instructed.
Ø Get the signature on experiment result sheet daily.
Ø For any clarification contact faculty/staff in charge only.
Ø Log off the system properly before switching off .

Don’ts
Ø Avoid unnecessary chat or walk.
Ø Disfiguring of furniture is prohibited.
Ø Avoid using cell phones unless absolutely necessary.
Ø Do not use personal pen drives without permission.
Ø Do not displace monitor, keyboard, mouse etc.
Ø Avoid late submission of laboratory reports.
EE102 BEE LABORATORY Semester I L-T-P 1 CREDIT
0-0-2

Experi Title of the Experiment Objective of the Experiment


ment
No.
1 Calibration of Ammeter To compare the readings of an Ammeter (M.C. or M.I.) with
those of a substandard one and hence to draw the (a) Calibration
curve (b) Correction Curve
2 Calibration of Voltmeter To compare the readings of a voltmeter (M.C. or M.I.) with
those of a substandard one and hence to draw the a) Calibration
curve (b) Correction Curve

3 Calibration of milli-voltmeter To calibrate a millivoltmeter as an ammeter with the help of a


as Ammeter substandard ammeter and hence to draw the, (a) Calibration
curve (b) Correction Curve
4 Verification of Thevenin’s To verify the Thevenin’s Theorem with the help of an
Theorem electronic trainer.
5 Verification of Maximum To verify the Maximum Power Transfer Theorem with the help
Power Transfer Theorem of an electronic trainer.
6 Power and Power Factor (Cos To measure the power dissipated in a single phase R-L circuit
Φ) in a single phase R-L series and to calculate power and also to draw phasor diagram for each
circuit. (3 voltmeter Method) reading and have to find the value of power factor from it.

7 Power and Power Factor in a To measure the power dissipated in a single phase R-L parallel
single phase R-L Parallel circuit and to calculate power factor (Cos Φ) by three ammeter
circuit. method.

8 Measurement of Power and To measure the power dissipated in a single phase R-L circuit
power factor by wattmeter. with the help of a wattmeter and find power factor by measuring
the voltage and current in the circuit.

Text book
Ø Electrical Machines, D P Kothari and R J Nagrath
Student Profile
Name
Roll Number
Department
Year

Student Performance
Sl. No. Title of the Experiment Remarks
1 Calibration of Ammeter

2 Calibration of Voltmeter

3 Calibration of milli-voltmeter as Ammeter

4 Verification of Thevenin’s Theorem


5 Verification of Maximum Power Transfer
Theorem
6 Power and Power Factor (Cos Φ) in a single
phase R-L series circuit. (3 voltmeter Method)

7 Power and Power Factor in a single phase R-L


Parallel circuit.

8 Measurement of Power and power factor by


wattmeter.

Office Use
Checked and found
…………………………………………………
Grade/ Marks
…………………………………………………
Signature
……………………………………………………