TITLE: DESIGN OF PADEYE USING CHEEK PLATES
LOCATION: Bottom of Spreader Beam
Reference: Rev C1
Material Properties:
Yield strength of plate Fy 345 MPa
Material performance factor phi 0.9
Loads (using factors for Lift Points):
Dynamic Amplification Factor DAF 1.1 (1.1 for onshore lift, 1.2 for offshore)
Skew Load Factor SLF 1.4 (generally 1.4)
Contingency Factor CF 1.35 (generally 1.35)
Load applied to padeye SWL 350 kN (35 T, 32mm)
Maximum angle from vertical Alpha 10 degrees
Factored Vertical Load Pf 877 kN = (1.05 + 1.35 * (DAF*SLF*CF-1))*SWL
Factored Horizontal Load Hf 44 kN = 0.05 * Pf (see Reference)
Dr
Padeye Geometry: Rm
CHEEK PL.
Diameter of Pin Dp 59 mm
Diameter of Hole Dh 62 mm
Diameter of Cheek Pl. Dc 140 mm MAIN PLATE
Thickness of Cheek Pl. Tc 32 mm Dh
Radius of Main Plate Rm 200 mm Hh
Height to Center of Hole Hh 95 mm
Length of Main Plate Lp 350 mm
Lp
Thickness of Main Plate Tp 32 mm
a) Capacity at Base of the Padeye
Case 1: Load acts Vertically
Factored Moment at Base Mf 5.5 kN.m = Hf * (Hh+Dh/2)/1000
Moment Resistance at Base Mr 27.8 kN.m = phi * (Lp * Tp^2/4) * Fy * 1e-6
Tension Resistance at Base Pr 3478 kN = phi* Lp * Tp * Fy * 1e-3
Interaction Mf/Mr 0.20
Pf/Pr 0.25
0.45 < 1.0 OK
Case 2: Load acts 10 degrees from Vertical
Shear at Base Vfy 152 kN =Pf*sin(alpha*pi()/180)
Shear Resistance at Base Vry 2295 kN = phi * Lp * Tp * 0.66 Fy * 1e-3
Tension at Base Pf_2 864 kN = Pf*cos(alpha*pi()/180)
Moment in Plane of Plate Mfy 19 kNm = Vfy * (Hh+Dh/2)/1000
Moment Resistance Mry 304 kNm = phi * (Tp*Lp^2/4) *Fy * 0.000001
Interaction Mf/Mr 0.20
Pf_2/Pr 0.25
0.455 Vfy/Vry 0.03 (Interaction from 13.4.6 of S16.1)
0.727 Mfy/Mry 0.05
0.52 < 1.0 OK
b) Shear Pullout Capacity of Ring
Tear out height hv 169 mm = Rm-Dh/2
Area subject to shear Aw 24768 mm2 = 2* (hv * Tp + 2*(Dc-Dh/2)*Tc)
Shear strength Fs 228 MPa = 0.66*Fy
Shear Resistance Vr 5076 kN = phi*Aw*Fs * 1e-3
Vr >= Pf OK
c) Pullout Capacity in Main Plate
Length in tension (1/4 cheek) Lt 110 mm = PI() * Dc * 1/4
Length in shear Ls 485 mm = PI() * Dc * 1/4 + 2*SQRT(Rm^2-(Dc/2)^2)
Area for pull out At 13755 mm2 = Tp * (Lt + 0.66*Ls)
Direct Tension Resistance TFr 4271 kN = phi*At*Fy * 1e-3
Tfr >= Pf OK
d) Bearing
Bearing Capacity Br 1759 kN = phi*Fy*Dp*(Tp+2*Tc)/1000
Br >= Pf OK
Page 1 of 1
Printed: 5/5/2020 at 12:07 PM