0% found this document useful (0 votes)
679 views6 pages

Thyssenkrupp Elevator (India) : Schematics - 1 Electrical Details

This document provides electrical schematics and details for a lift/elevator installation. It includes: - Wiring diagrams showing connections from the controller, motor, and lights to the main power supply and circuit protection devices. - Specifications for cable sizes and types for the power and lighting circuits. - Details on the hoistway light layout including bulkhead fittings, switches, and locations of top, intermediate, and pit lights. - Notes that the installation engineer should mark the cable routes through the lift shaft on the drawing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
679 views6 pages

Thyssenkrupp Elevator (India) : Schematics - 1 Electrical Details

This document provides electrical schematics and details for a lift/elevator installation. It includes: - Wiring diagrams showing connections from the controller, motor, and lights to the main power supply and circuit protection devices. - Specifications for cable sizes and types for the power and lighting circuits. - Details on the hoistway light layout including bulkhead fittings, switches, and locations of top, intermediate, and pit lights. - Notes that the installation engineer should mark the cable routes through the lift shaft on the drawing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

ThyssenKrupp Elevator Electrical Details Date :

( India ) Schematics - 1 JOB NO


Layout Drg. No.
Project Name and Location :
Wing No. Lift No.

To To To For m/c room For car light in For hoistway


Controller Motor Controller lights Controller lights

To Governor unit

DPIC DPIC DPIC


TPIC OR OR OR
ELCB MCB MCB MCB

Earthing plate

12 gauge GI or 14 gauge copper. M/C Room area

Earthing
3 Phase 4 Wires Power Cable for
bracket
……….. HP Motor.

Single Phase 3 Wires Lighting


6 Guage GI or Cable for Main Light supply.
8 Gauge
copper or
3X20
Aluminium
strip.

METER ROOM area

Earthing from earth


plate. DPIC
TPIC OR
MCB
Earthing from electrical
source.

TKE's Representative's Name : Client's Representative's Name :


Doc No. : 0095OP999901360 Page 8

ThyssenKrupp Elevator Electrical Details Date :

( India ) Schematics - 2 JOB NO


Layout Drg. No.
Project Name and Location :
Wing No. Lift No.

Hoistway light wiring from m/c room


hoistway light switch to pit light box.
M/C Room

Terrece Level
Top light

Top bulk head fitting to be fixed 2500 mm up


from top floor landing.

Top floor Level

Bulk head fitting with 40 watts lamp &


3 pin plug socket with operating switch
to be provided on each landing or at
every 3 meters..

300 mm 300 mm

300 mm 300 mm

Installation Engineer should mark


the position in this drawing from
which corner the power and light
cables should run through the lift
shaft including shaft lights.

Pit Light Sw.

Pit sw.and
Hooter Box
1000 mm
just near the Bottom floor Level
floor level

Pit light Pit Depth

6oo mm

TKE's Representative's Name : Client's Representative's Name :


Doc No. : 0095OP999901360 Page 9

You might also like