UT61E Computer Interface Software
UT61E Computer Interface Software
¾ System Requirements(UT61E)
To use UT61E Interface Program, you need the following hardware and software:
An IBM PC or equivalent computer with 80586 or higher processor and 600 x 800 pixel or better
monitor.
Microsoft Windows 95 or above.
At least 128MB of RAM.
Can access to a local or a network CD-ROM.
A free serial port RS-232 and a usb port.
A mouse or other pointing device supported by Windows.
¾ Hardware install:
If what to use is multimeter the RS-232s provide with the form connect a
people's line, the RS-232 pick up a people line of red unauthorized biography
lose the line to receive to carry to insert multimeter fix in the slot with a back of
the form protection, then go on-line of another on carry with computer of string
a right conjunction is then.
If what to use is multimeter the USB provide with the form connect a people's
line, the USB pick up a people line of red unauthorized biography lose the line to
receive to carry to insert multimeter fix in the slot with a back of the form
protection, then go on-line of another on carry with computer of string a right
conjunction is then.
¾ Installing UT61E Interface Program
(figure 1)
******************************************** 1*********************************************
UT61E Interface Software Manual
3.click UT61E Setup to display the contents of the folder.Double-click the file Setup.Exe.
(see figure 2)
(figure 2)
(figure 3)
******************************************** 2*********************************************
UT61E Interface Software Manual
(figure 4)
6. The software installs to complete, the customer can find out" the DMM Interface
Program- UT61E" in program folder ,see figure 5
click to Test
(figure 5)
******************************************** 3*********************************************
UT61E Interface Software Manual
.From the Windows Start menu, choose Programs > DMM Interface Program > UT61E
Press COMSetup to select corresponding COM 1/ 2 / 3 / 4. OR USB connect
Press Connect from menu bar to start the connection, the icon will be displayed.
Below is the full screen of the software shown on the computer (see figure 6)
Icon area
(figure 6)
******************************************** 4*********************************************
UT61E Interface Software Manual
¾ Graphic operation
(figure 7)
During the connection, you can select the following functions by clicking the
corresponding icon or the menu bar:
Fill: Click the box to select “fill-up graph” or unclick to select “line graph”.
Record: Setting the number of record to be shown on graphic.
******************************************** 5*********************************************
UT61E Interface Software Manual
¾ Data record
(figure 8)
During the connection, you can select the following functions by clicking the corresponding icon or
the menu bar:
Repeat: Click the box to keep the repeated record, or unclick the box to ignore the repeated record.
The
repeated records will be shown in graphic no matter what the selection is.
Sampling Interval: Click to enable sampling interval function, or unclick to disable the function
Enter the sampling interval’s time, the unit is second.
Clear: To clear all the current records permanently.
Open fils: To read records form old file (*.db) .
Save as: To save all the current records to file (*.txt、*.xls、*.db)。
print: To print the current records.
(figure9)
******************************************** 6*********************************************
UT61E Interface Software Manual
Set max value: Click to enable the SetMax function or unclick to disable.
Enter the upper limit value in integer. It will only compare the current value obtained to the upper limit in
integer, it does not identify range or function,
Set min value: Click to enable the SetMin function or unclick to disable.
Enter the lower limit value in integer. It will only compare the current value obtained to the upper limit in
integer, it does not identify range or function.
Set Max value
Measure value
(figure 10)
: The Meter is connected properly to the computer and data is recording.
OL!! Overload, the recorded value exceeds the SetMax and SetMin value. It will be flashing and the
computer will connect .
******************************************** 7*********************************************
UT61E Interface Software Manual
Remarks:
If abnormal digits or symbols were found after installation, please remove font ”UNIT-A2” and then
install new font set from ”FONT” directory on the provided CD-ROM.
The software designed to display the current measured value from the Meter. When the data hold,
Max or Min functions are enabled, it is normal that the Meter displayed value difference from the
computer due to the Meter display has already locked.
**END**