PROPOSED EARTH RETAINING STRUCTURE USING
WELLGUARD WALL SYSTEM
+ 68.0
1200 1245
CAPPING BEAM + 66.0
150 mm dia. Sub Soil Drain Wrapped
SANDY SOIL
in Geotextile & Laid To Fall
W23 PANEL
3000
Determined
On Site
(2000)
To Be
+ 63.0
BOUNDARY
Road Pavement
900mm Wide
x 450mm ht.
Tie Beam
PT12 POST
9000
TYPICAL SECTION @ HIGHEST BACKFILL LEVEL
1200
610 225 450 225
150 mm dia. Sub Soil Drain Wrapped
in Geotextile & Laid To Fall
W23 PANEL
To Be Determined On Site
COARSE
AGGREGATE
(2000)
WEEP
BOUNDARY
HOLES
2T16
200 + 63.0
250
3T16
R10 @ 200 Links
1stPOUR
900
PT12 POST
TIE BEAM DETAIL
ALL CONCRETE MIX TO
GRADE C 25/30 (Cube
compressive strength of 30
N/mm2 @ 28 days)
G H
6.00m 40.70m 16.00m
TOW +66.00m
TOW +65.00m TOW +65.00m
BOW +63.00m
BOW +63.00m BOW +63.00m
Wall Height 3.0m
Wall Height 2.0m Wall Height 2.0m
W23 Panels
W22 Panels W22 Panels
63.45 64.00 64.00
63.00 63.00
Datum 60.00m
10.20m 27.80m 18.20m 5.50m
0.50m
62.70m
Elevation Of WellGuard Wall System