0% found this document useful (0 votes)
65 views

2700 0 29 6 137 Rectangular Column (Reinf. On 2 Sides) : Short Column Slender Column

This document contains technical specifications and calculations for the design of a reinforced concrete column, including load values, section properties, material properties, effective length calculations, moment due to eccentricity, percentage reduction assumptions, and final design loads. The document contains calculations for moments in the x and y directions at various steps in the design process.

Uploaded by

manoj_mousam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views

2700 0 29 6 137 Rectangular Column (Reinf. On 2 Sides) : Short Column Slender Column

This document contains technical specifications and calculations for the design of a reinforced concrete column, including load values, section properties, material properties, effective length calculations, moment due to eccentricity, percentage reduction assumptions, and final design loads. The document contains calculations for moments in the x and y directions at various steps in the design process.

Uploaded by

manoj_mousam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

A Load 2700

Moment x-dir y-dir


Bottom 0 29
Top 6 137

Col Type Rectangular Column (reinf. on 2 sides)

x-dir y-dir
Unsupported Length 8250 8250
Col Size 200 900
d'/D 0.05 0.20
d' 40

Concrete 20
Steel 415

Effective Length Ratio


0.80 from IS Code
0.90 manual Calculation
Effective Length to be considered from Manual Calculation
Effective Length (le) lex Ley
7425 7425
E Slenderness Ratio
le/D 8 Short Column
le/b 37 Slender Column
Moment due to Slen Muax 0
Muay 372

Min Ecc ex 46.5


ey 23.2
Moment due to ecc Mux 125.55
Muy 62.55

G Reduction of Moments
Percentage assumed 2.18
Asc 3924

Puz 2841

k1 K2 Pb
x-x 0.219 0.096 367
y-y 0.184 -0.022 291

Kx 0.06
Ky 0.06

Additional Moments due to ecc Max 0


May 21

Modified Initial Moments Mux 3.6


Muy 70.6

Summary of Moments
A Moment due to eccentricity + Modified additional moments
Mux 126
Muy 83

B Modified initial moments + Modified additional moments


Mux 4
Muy 91

C 0.4Muz + Modified additional moments


Mux 0
Muy 32

Final Design Loads


Pu 2700
Mux 126
Muy 91

# Sensitivity : This Document is Classified as "LNT Internal Use".

You might also like