Continental PST marine
Injector type
BK2Q-9K546-AG
Reference Number
Old Grading Data
New Grading Data 98EJEF
Date and Time 01/07/2019 11:32:49
Calibration
Test comments ford ranger#2
Electrical
Parameter Min. Max. Value Units Status
Capacitance 0.75 2.1 1.04 μF
Flush
Purge
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1598 bar
Response 0 0 383 µS
Delivery 0 0 60.86 mm3/st
Back leak flow 0 0 32.5 mL/min
TP1
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1599 bar
Response 304 456 386 µS
Delivery 55.61 63.73 61 mm3/st
Back leak flow 0 80 34.4 mL/min
TP2
Parameter Min. Max. Value Units Status
Pressure 1386 1414 1401 bar
Response 292 438 373 µS
Delivery 37.17 42.72 40.43 mm3/st
Back leak flow 0 55 24.9 mL/min
TP3
Parameter Min. Max. Value Units Status
Pressure 1188 1212 1201 bar
Response 280 420 342 µS
Delivery 1.22 5.65 2.36 mm3/st
Back leak flow 0 45 2.9 mL/min
TP4
Parameter Min. Max. Value Units Status
Pressure 990 1010 999 bar
Response 264 396 333 µS
Delivery 7.49 13.06 9.62 mm3/st
Back leak flow 0 45 2.5 mL/min
TP5
Parameter Min. Max. Value Units Status
Pressure 740 760 750 bar
Response 258 386 330 µS
Delivery 5.33 10.13 6.91 mm3/st
Back leak flow 0 30 7.2 mL/min
TP6
Parameter Min. Max. Value Units Status
Pressure 290 310 301 bar
Response 0 0 0 µS
Delivery 2.51 6.66 4.94 mm3/st
Back leak flow 0 30 4.4 mL/min
Static leak
Parameter Min. Max. Value Units Status
Pressure 990 1010 1000 bar
Response 0 0 0 µS
Delivery 0 0 0 mm3/st
Back leak flow 0 30 7.7 mL/min
NOP
Parameter Min. Max. Value Units Status
Injector pressure 57 157 0 bar
Delivery 0.2 2 0 mm3/st
Grading code
Sv = 4.00 : T v = Issue-11 : F p = A262A902 : F v = 1.25 : Rv = 1.05 : Lv = 2.06 :