100% found this document useful (2 votes)
284 views2 pages

Bk2q-9k546-Ag 20190701 113249 PDF

The document contains test results from calibrating a Continental PST marine injector with reference number 98EJEF on 01/07/2019 at 11:32:49. It includes measurements for parameters like pressure, response, delivery and back leak flow across different tests points like flush, purge, TP1-TP6, static leak and NOP. It also lists the grading code details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
284 views2 pages

Bk2q-9k546-Ag 20190701 113249 PDF

The document contains test results from calibrating a Continental PST marine injector with reference number 98EJEF on 01/07/2019 at 11:32:49. It includes measurements for parameters like pressure, response, delivery and back leak flow across different tests points like flush, purge, TP1-TP6, static leak and NOP. It also lists the grading code details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Continental PST marine

Injector type
BK2Q-9K546-AG
Reference Number
Old Grading Data
New Grading Data 98EJEF
Date and Time 01/07/2019 11:32:49

Calibration
Test comments ford ranger#2

Electrical
Parameter Min. Max. Value Units Status
Capacitance 0.75 2.1 1.04 μF

Flush

Purge
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1598 bar
Response 0 0 383 µS
Delivery 0 0 60.86 mm3/st
Back leak flow 0 0 32.5 mL/min

TP1
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1599 bar
Response 304 456 386 µS
Delivery 55.61 63.73 61 mm3/st
Back leak flow 0 80 34.4 mL/min

TP2
Parameter Min. Max. Value Units Status
Pressure 1386 1414 1401 bar
Response 292 438 373 µS
Delivery 37.17 42.72 40.43 mm3/st
Back leak flow 0 55 24.9 mL/min

TP3
Parameter Min. Max. Value Units Status
Pressure 1188 1212 1201 bar
Response 280 420 342 µS
Delivery 1.22 5.65 2.36 mm3/st
Back leak flow 0 45 2.9 mL/min

TP4
Parameter Min. Max. Value Units Status
Pressure 990 1010 999 bar
Response 264 396 333 µS
Delivery 7.49 13.06 9.62 mm3/st
Back leak flow 0 45 2.5 mL/min
TP5
Parameter Min. Max. Value Units Status
Pressure 740 760 750 bar
Response 258 386 330 µS
Delivery 5.33 10.13 6.91 mm3/st
Back leak flow 0 30 7.2 mL/min

TP6
Parameter Min. Max. Value Units Status
Pressure 290 310 301 bar
Response 0 0 0 µS
Delivery 2.51 6.66 4.94 mm3/st
Back leak flow 0 30 4.4 mL/min

Static leak
Parameter Min. Max. Value Units Status
Pressure 990 1010 1000 bar
Response 0 0 0 µS
Delivery 0 0 0 mm3/st
Back leak flow 0 30 7.7 mL/min

NOP
Parameter Min. Max. Value Units Status
Injector pressure 57 157 0 bar
Delivery 0.2 2 0 mm3/st

Grading code

Sv = 4.00 : T v = Issue-11 : F p = A262A902 : F v = 1.25 : Rv = 1.05 : Lv = 2.06 :

You might also like