Iraq - Wireless Hardware Acceptance Check List - V1: # Site Information

The document is a checklist for accepting wireless hardware at an Iraq site. It contains 44 items to inspect, including verifying that the cabinet and batteries are in good condition, cables are properly installed and labeled, alarms and grounding systems are correctly configured, and radio equipment is installed according to standards. Upon completion of the inspection, the site conditions will be noted as conditionally accepted, rejected, or conditionally rejected.

Uploaded by

Aws Hameed
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views

Iraq - Wireless Hardware Acceptance Check List - V1: # Site Information

The document is a checklist for accepting wireless hardware at an Iraq site. It contains 44 items to inspect, including verifying that the cabinet and batteries are in good condition, cables are properly installed and labeled, alarms and grounding systems are correctly configured, and radio equipment is installed according to standards. Upon completion of the inspection, the site conditions will be noted as conditionally accepted, rejected, or conditionally rejected.

Uploaded by

Aws Hameed
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

# Site Information IRAQ_WIRELESS HARDWARE ACCEPTANCE CHECK LIST_V1

Comments
1 SITE A ID
2 SITE B ID
Back
3 LINK TYPE :
Edge ✘ Termi
4 SITE A NAME
bone
5 SITE B NAME nal
6 Site topology (GF/RT) site
7 Site Type (ID/OD)
8 Site category
9 Region
10 Area
11 Company
12 Inspection Date Conditio
13 Vendor Representative : Conditio
14 BeeCable Inspection : nally Reject
Task Description Accept nally Reject
#
accepte ed Status Comments
1
ed
Cabinet has no external or internal damage
accepte ed i
2 Cabinet is sealed and weatherd proof i
3 d
Cabinet is fixed and bolted to concert foundation by 4 screws j i
4 Cabinet door can open without obstacle j i
5 Cabinet without internal Alarms j i
6 Cabinet without External alarms j ir
7 Cabinet Bulbar connect with Main Busbar with labels j ir
8 check Door coolant system j ir
9 All boards are plugged in correctly and secured. Racks configuration is according to site configuration . j ir
10 cabinet configuration is verified with configuration data sheet. j ir
11 All Cables entered in correct hole j ir
12 No scratches and damage in the Batteries (for new Batteries only ) j ir
13 Batteries Properly installed (write number of battery set and capacity ) , battery test j ir
14 Batteries pip & Sensor & cover installed j ir
15 Batteries cables systemized with labeled both ends with shrink j ir
16 internal Alarm cabling is wired and labeled correctly in both sides j ir
17 All external alarms connected to the SLPU, labeled and Systemized j ir
18 BBU grounded j ir
j ir
j
19 BBU Main and Standby Power connected to 06 port in DCDU1 and DCDU2 with labels and Systemization
20 BBU fixed by 4 screws
j ir
21 All Fibers connected with BBU with Good Systemization & Labels ir
22 DCDU grounded j ir
23 DCDU cables systemized with labels bootless and shrink j ir
24 DCDU fixed by 4 screws j ir
25 All RRU cables connected with DCDU with Good Systemization & Labels & shrink j ir
26 All Cables in the Rectifier with Bootless j ir
27 All Cables in the Rectifier installed in the CB of LLVD & BLVD according to Huawei Design j ir
j ir
j
28 AC cable with bootless at both ends (Rectifier & MDB)
ir
j
29 GPS installed properly
ir
j
30 GPS Arrester grounded
ir
j
31 GPS Cable covered by shielded flexible PIP
ir
j
32 GPS Cable weatherproofed
ir
j
33 DC Cables & Fiber Systemized from the cabinet till base of tower without cross
ir
j
34 DC Cables Systemized in the tower without cross by clamps each 1.5m
ir
j
35 DC Cable Grounded from RRU Side
ir
j
36 RRU Installation according to Huawei Standard
ir
37 RRU DC power cable grounded by earth kit
j ir
38 RRU Grounding & Labeled from RRU Side & BusBar
j ir
39 Fiber Loop inside tray box with color Labels not less than 3m loop
j ir
40 Tray and loop Box installed properly
j ir
41 RET is connected and waterproofed
j ir
42 RET is fixed and labeled
j ir
43 Optical cables systemization and labels from both ends
j ir
44 Optical cables fixing and clamped on tower & without cross
j ir
45 Jumpers weatherproofed & Labeled from RRU Side & Antenna Side
j ir
46 Antenna directions and tilt angles and height according RF design
j ir
47 Antenna fittings tightened and Antenna without damage
j ir
48 Maximum VSWR is less than 1.3
j ir
49 No Rubbish after swap installation
j ir
50 No Dismantle Materials on site
j ir
51 All ground cables connected without Daisy chain
j ir
52 Key and IT cable available on site
j ir
53 All new installed Busbar should be installed/isolated properly
j ir
54 No potential security hazard.
j ir
55 Site secured. Doors are locked tight.
j ir
56 clear alarm from NMC & SO EM
j ir
57 Antenna Mechanical Tilt installation (Mechanical tilt =0)
j ir
58 all link budget, RF design ,Huawei standard to be handed over to O&M on site j
j mrrAzimuth (Degree)
Antenna height
# Sector ID Leg No. M -Tilt (Degree)
(from ground)
r
1 Sector 1 r
2 Sector 2 r
3 Sector 3
4 Sector 4
# EXTERNAL ALARM DESCRIPTION. Status Comments
1 SHELTER DOOR OPEN (for indoor only) i
i
2 HIGH ROOM TEMPERATURE 32°C (for indoor only)
j i
3 AIRCON (1) FAILURE  (for indoor only)
j i
4 AIRCON (2) FAILURE  (for indoor only)
j i
5 GENERATOR 1 FAILURE
j ir
6 GENERATOR 2 FAILURE
j ir
7 GENERATOR LOW FUEL ALARM
j ir
8 AVIATION LIGHT FAILURE
j ir
9 AC MAINS FAILURE
j ir
10 RECTIFIER FAULT ALARM
j ir
11 RECTIFIER MAJOR
j ir
12 RECTIFIER MINOR
j ir
13 DC LOW VOLTAGE ALARM
j ir
14 FIRE ALARM (for indoor only)
j r
j r
r
r
r