This document discusses converting graphics from R3.x to R4.x standards. Key points include: 1. The conversion process involves using tools like the Project Attribute Utility and HIS Database Conversion Tool to update attributes and databases during the conversion from R3.08.x to R4.01.x. 2. Additional work is required to customize screen resolutions, rework link parts and text alignment, and check for overlapping Z-orders and regrouping of entities after conversion. 3. New graphic builder tools in R4.x like stencils, out-of-the-box and custom parts, and layers are discussed in relation to additional work needed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views33 pages

Yokogawa Centum VP Hmi Graphics Design PDF

This document discusses converting graphics from R3.x to R4.x standards. Key points include: 1. The conversion process involves using tools like the Project Attribute Utility and HIS Database Conversion Tool to update attributes and databases during the conversion from R3.08.x to R4.01.x. 2. Additional work is required to customize screen resolutions, rework link parts and text alignment, and check for overlapping Z-orders and regrouping of entities after conversion. 3. New graphic builder tools in R4.x like stencils, out-of-the-box and custom parts, and layers are discussed in relation to additional work needed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

Centum VP Graphics

Olivier Suc
Project Manager
Good Manufacturing
Practices, Inc

<date> Company Logo


From Requirements to Delivery

1. Customer’s Graphic Specifications


2. R3.x standard parts and graphics
3. Conversion process
4. Additional work
5. Summary

<Presentation Title> 2009 User Conference& Technology Fair


<date>
2
Customers’ Graphic Specifications

Power Industry Standards


Piping Colors
– DodgerBlue (Feedwater)
– Salmon (Steam)
– Yellow (Gas)
– Brown (Fuel Oil)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
3
Customers’ Graphic Specifications

Graphic Requirements
– Valve Colors and Status Indications

Mode Status
Status
Indication

Traveling
Indication

<Presentation Title> 2009 User Conference& Technology Fair


<date>
4
Customers’ Graphic Specifications

Graphic Requirements
– Pumps Colors and Status Indications

Status
Indication
Mode Status (Stopped
(Manual/Auto) /Running)

Permissives

<Presentation Title> 2009 User Conference& Technology Fair


<date>
5
R3.x standard parts and graphics

New Project but re-use existing standards


Current Hardware/Software Standards
– Dell (Corporate Program)
– Windows XP and Windows 2003
– Matrox Card, 4 LCD-screen configurations
– R3.08.10
Graphic standards to re-use
– Multi-platform Corporate standards (Ovation, Centum)
– Operators Familiarity (behavior, look and feel)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
6
R3.x standard parts and graphics

Customer has
– Interest in the new Trend tool
– Interest in the new Alarm Management System
– Interest in the new graphic capabilities

<Presentation Title> 2009 User Conference& Technology Fair


<date>
7
R3.x standard parts and graphics

Hardware/Software
– Dell (Corporate Program)Æ T3400 Æ PCI Slot-5 is
not to be used for VI-701 card.
– Windows XP and Windows 2003
– Matrox Card, 4 LCD-screen configurations Æ Nvidia
NVS 440 (4-screen) or NVS290 (2-screen)
– R3.08.10ÆR4.01.03
Graphic standards to re-use
– Multi-platform Corporate standards (Ovation, Centum)
– Operators Familiarity (behavior, look and feel)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
8
R3.x standard parts and graphics

Graphic standards to re-use


– Multi-platform Corporate standards (Ovation, Centum)

– Operators Familiarity (behavior, look and feel)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
9
R3.x standard parts and graphics

<Presentation Title> 2009 User Conference& Technology Fair


<date>
10
Conversion Process

Develop R3.08.x applications for existing


customers
Develop R4.01.x applications for new customers
ÆVMWare

<Presentation Title> 2009 User Conference& Technology Fair


<date>
11
Conversion Process

<Presentation Title> 2009 User Conference& Technology Fair


<date>
12
Conversion Process

R3.08 to R4.01 conversion


– Project Attribute Utility ÆRegistration
– System View

<Presentation Title> 2009 User Conference& Technology Fair


<date>
13
Conversion Process

R3.08 to R4.01 conversion


– HIS Database Conversion Tool

Unchecked – Not much converts Checked – All converts but


ungrouped

<Presentation Title> 2009 User Conference& Technology Fair


<date>
14
Conversion Process

R3.08 to R4.01 conversion

– Necessity to go to all link parts and formerly grouped


entities and check all overlapping Z-order
– Necessity to re-group all link parts and formerly
grouped entities.
Æ Most of the work for the conversion. Could be
painstaking with animated parts.

<Presentation Title> 2009 User Conference& Technology Fair


<date>
15
Conversion Process

System View looks the same

Except for the


(CENTUM VP) in
the title bar.

<Presentation Title> 2009 User Conference& Technology Fair


<date>
16
Conversion Process (Before)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
17
Conversion Process (After)

<Presentation Title> 2009 User Conference& Technology Fair


<date>
18
Additional Work

1. Screen resolution seems off


Æneed to customize the dimension
2. Text alignment is off
Æ Rework the linkparts or apply 4.01.26 registry patch

<Presentation Title> 2009 User Conference& Technology Fair


<date>
19
Additional Work

New Graphic Builder

<Presentation Title> 2009 User Conference& Technology Fair


<date>
20
Additional Work

Stencil (linkparts)
Graphic window
<Presentation Title> 2009 User Conference& Technology Fair
<date>
21
Additional Work

Out-Of-The-Box
Stencil parts

Custom parts

<Presentation Title> 2009 User Conference& Technology Fair


<date>
22
Additional Work

Stencil and parts edition

Part tab

Right Click

<Presentation Title> 2009 User Conference& Technology Fair


<date>
23
Additional Work

Stencil and parts


– Make a collection of re-usable parts
– Stencil is saved in its own folder inside the project
folder (Project folder\linkpartsVP)
– Stencil folder can be copied over to another project
using Windows Explorer

<Presentation Title> 2009 User Conference& Technology Fair


<date>
24
Additional Work

Layers
Insert a picture
of a P&ID

Graphic Layers to
separate different
categories of data

<Presentation Title> 2009 User Conference& Technology Fair


<date>
25
Additional Work

‘Controls’ Layer is active. All Layers are displayed.

<Presentation Title> 2009 User Conference& Technology Fair


<date>
26
Additional Work

‘Oil Layer’ Layer is active. All Layers are hidden.

<Presentation Title> 2009 User Conference& Technology Fair


<date>
27
Additional Work

Layers
– Simplify the management of complex graphics
– Separate elements of the graphics by categories
– Improve placement and edition accuracy

<Presentation Title> 2009 User Conference& Technology Fair


<date>
28
Additional Work

Parts Placement / Position


– As originally defined the parts will be inserted with
(X1,Y1) coordinates as a reference.

Y2
Y1

X1 X1

Overall length

<Presentation Title> 2009 User Conference& Technology Fair


<date>
29
Additional Work

Parts Placement / Position


– As the part get updated, Y2 > Y1.
– The graphic will see the newly updated pump drop
from its former location to Y2-Y1 pixels below
– Similar behavior will occur if the X axis is changed.

<Presentation Title> 2009 User Conference& Technology Fair


<date>
30
Additional Work

Universal Color Design


– Computers color coding
Name Area R G B
Light Blue Raw Water, Treated Water and Feedwater 46 82 B4
Grey Activated Carbon Filters 66 66 66
Light Pink Cation & Anion FF C0 CB
Dark Blue Waste Neutralization 19 19 70
Orange Sulfuric Acid FF A5 0
Green Caustic 9A CD 32
Light Pink Phosphate FF B5 FF
Olive Green Re-Alkalization 80 80 0
Yellow System Maintenance FF FF 55
Dark Pink Emergency Eye Wash F4 0 7A
White Electrical Information FF FF FF

– Standardization of color schemes and conventions

<Presentation Title> 2009 User Conference& Technology Fair


<date>
31
Summary

Still not converting the graphics 100%


Unified Color Design
Layers
Stencils
XAML
WPF (Windows Presentation Foundation) .Net
objects/components

<Presentation Title> 2009 User Conference& Technology Fair


<date>
32
Title: Tahoma Bold, 22 points
(do not use an extremely different size).

First Level: Tahoma, 28 points


Second Point: Tahoma, 28 points
Third Point: Tahoma, 28 points
Fourth Point: Tahoma, 28 points
– Subpoint: Tahoma, 24 points
• Another Subpoint: Tahoma, 20 points
– Another Subpoint: Tahoma, 18 points
» Last Point: Tahoma, 16 points

<Presentation Title> 2009 User Conference& Technology Fair


<date>
33

You might also like