Datasheet: Variable Speed Drives

This document provides specifications for a variable speed drive with the following key details: - Model reference is SACFW110017T4SZ and product code is 10574765 - It has a rated current of 17A under normal overload conditions and 13.5A under heavy overload conditions. - It can control motors up to 12.5HP/9.2kW under normal overload conditions and up to 10HP/7.5kW under heavy overload conditions when powered from 460V/60Hz.

Uploaded by

simbamike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views5 pages

Datasheet: Variable Speed Drives

This document provides specifications for a variable speed drive with the following key details: - Model reference is SACFW110017T4SZ and product code is 10574765 - It has a rated current of 17A under normal overload conditions and 13.5A under heavy overload conditions. - It can control motors up to 12.5HP/9.2kW under normal overload conditions and up to 10HP/7.5kW under heavy overload conditions when powered from 460V/60Hz.

Uploaded by

simbamike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DATASHEET

Variable Speed Drives


Main Features
Reference : SACFW110017T4SZ
Product code : 10574765
Product line : CFW11

Basic data
Power supply : 380-480 V
Input minimum-maximum voltage : 323-528 V
Number of phases
Input :3
Output :3
Supply voltage range 380-480 V 380-480 V
Overload regime Normal (ND) Heavy (HD) Normal (ND) Heavy (HD)
Rated current 17A 13.5
Overload current at 60 s 18,7A 18,7A
Overload current at 3 s 25,5A 30

Maximum applicable motor


Voltage/Frequency Power (HP / kW) [1]
Normal Overload (ND) Heavy Overload (HD)
380V / 50Hz 10 / 7,5 7,5 / 5,5
380V / 60Hz 10 / 7,5 7,5 / 5,5
400V / 50Hz 10 / 7,5 7,5 / 5,5
400V / 60Hz 10 / 7,5 7,5 / 5,5
440V / 50Hz 12,5 / 9,2 10 / 7,5
440V / 60Hz 12,5 / 9,2 10 / 7,5
460V / 60Hz 12,5 / 9,2 10 / 7,5
____ 480V / 60Hz 12,5 / 9,2 10 / 7,5
Dynamic braking [2] : Standard with braking
Electronic supply : Internal
Safety Stop : No
RFI internal filter [3] : Without filter
External filter : Not available
Link Inductor : Yes
Memory card : Included in the product
USB port : Standard in the product
Line frequency : 50/60Hz
Line frequency range (minimum - maximum) : 48-62 Hz
Phase unbalance : Less or equal to 3% of input rated line voltage
Transient voltage and overvoltage : Category III
Rated current of single-phase input
- Overload (ND) :
- Overload (HD) :
Rated current of three-phase input
- Overload (ND) : 17A
- Overload (HD) : 13,5 A
Power factor : 0,94
Displacement factor : 0,98
Rated efficiency : ≥ 97%
Maximum connections (power up cycles - on/off) per hour : 60
DC power supply : Allow
Standard switching frequency
- Overload ND : 5 kHz
- Overload HD : 5 kHz
Selectable switching frequency : 1,25; 2; 2,5; 5 and 10 kHz
Real-time clock : Yes, in the HMI
COPY Function : Yes, by HMI/MMF
Dissipated power:
Mounting type Overload Overload (*)
ND HD ND HD
Surface 360 W 270 W Not applicable Not applicable
Flange 50 W 40 W Not applicable Not applicable
Source available to the user
Output voltage : 24 Vcc
Maximum capacity : 500 mA

The information contained are reference


16/04/2020 Page 1 / 4
values. Subject to change without notice.
DATASHEET
Variable Speed Drives
Control/performance data
Power supply : Switched-mode power supply
Control method : V/f, VVW, Vector and PM motor
Encoder interface : Only with 'Slot 2' accessory
Control output frequency : 0 to 300 Hz
Frequency resolution : Equivalent to 1 rpm
V/F Control
- Speed resolution : 1% of rated speed
- Speed range : 1:20
VVW Control
- Speed resolution : 1% of rated speed
- Speed range : 1:30
Sensorless vector control
- Speed resolution : 0,5% of rated speed
- Speed range : 1:100
Vector control with encoder
- Speed resolution : 0,05% of rated speed
- Speed range : Up to 0 rpm
Analog inputs
Quantity (standard) :2
Levels : 0-10V, 0/4-20mA and -10-+10V
Impedance
- Impedance for voltage input : 400 kΩ
- Impedance for current input : 500 Ω
Function : Programmable
Maximum allowed voltage : ±30 Vcc
Digital inputs
Digital inputs - Quantity (standard) :6
Activation : Active low and high
Maximum low level :3V
Minimum high level : 18 V
Input current : 11 mA
Maximum input current : 13,5 mA
Function : Programmable
Maximum allowed voltage : 30 Vcc
Analog outputs
____
Analogic outputs - Quantity (standard) :2
Levels : 0 to 10V, 0 to 20mA and 4 to 20mA
RL for voltage output : 10 kΩ
RL for current output : 500 Ω
Function : Programmable
Digital outputs
Digital outputs - Quantity (standard) : 3 NO/NC relays
Maximum voltage : 240 Vca
Maximum current :1A
Function : Programmable
Communication
- Modbus-RTU (with accessory: RS485-01; RS485-05; CAN/RS485-01; RS232-01 or RS232-05)
- Modbus/TCP (with accessory: MODBUSTCP-05)
- Profibus DP (with accessory: PROFDP-05)
- Profibus DPV1 (with accessory: PROFIBUS DP-01)
- Profinet (with accessory: PROFINETIO-05)
- CANopen (with accessory: CAN/RS485-01 or CAN-01)
- DeviceNet (with accessory: DEVICENET-05; CAN/RS485-01 or CAN-01)
- EtherNet/IP (with accessory: ETHERNET/IP-05 or ETHERNETIP-2P-05)
- EtherCAT (with accessory: ETHERCAT-01)
- BACnet (with accessory: RS485-01 or CAN/RS485-01)
Protections available
- Output overcurrent/short circuit
- Power supply phase loss
- Under/Overvoltage in power
- Overtemperature
- Motor overload
- IGBT's modules overload
- Fault/External alarm
- Breaking resistor overload
- CPU or memory failure
- Output phase-ground short circuit
Operation interface (HMI)
Avaliability : Included in the product
Installation : Local
Number of HMI buttons :9

The information contained are reference


16/04/2020 Page 2 / 4
values. Subject to change without notice.
DATASHEET
Variable Speed Drives
Operation interface (HMI)
Display : Graphic LCD
Indication accuracy : 5% of rated current
Speed resolution : 1 rpm
Standard HMI degree of protection : IP56
HMI battery type : CR2032
HMI battery life expectancy : 10 years
Remote HMI type : Detachable of the inverter
Remote HMI frame : Accessory
Remote HMI degree of protection : IP56
Ambient conditions
Enclosure : IP21
Degree of pollution :2
Temperature
- Minimum : -10 °C / 14 °F
- Nominal [4] : 50 °C / 122 °F
Current reduction factor [5] : 2 % per °C of 50 (122) o 60 °C (140 °F)
Relative humidity (non-condensing)
- Minimum : 5%
- Maximum : 90%
Altitude
- Rated conditions : 1000 m (3281 ft)
- Maximum altitude allowed for operation : 4000 m (13123 ft)
Current Reduction factor[6]
- Current derating factor (for altitudes above rated) : 1% for each 100 m above
- Voltage derating factor (for altitudes above 2000 m / 6562 ft) : 1,1% for each 100 m above
Sustainability policies
RoHS : Yes
Conformal Coating : 3C2
Dimensions
Size :B
Height : 316 mm / 12.4 in
Width : 190 mm / 7.48 in
Depth : 227 mm / 8.94 in
Weight : 9,1 kg / 20.1 lb
____
Mechanical installation
Mounting position : Surface or flange
Fixing screw : M5
Tightening torque : 5 N.m / 3.69 lb.ft
Allows side-by-side assembly : Yes, without top cap
Minimum spacing around the inverter
- Top : 40 mm / 1.57 in
- Bottom : 45 mm / 1.77 in
- Front : 10 mm / 0.39 in
- Side : 30 mm / 1.18 in

Electrical connections
Cable gauges and tightening torque:
Recommended cable Recommended tightening torque
gauge to 75 °C (167 °F)
Power 4,0 mm² (10 AWG) 1,2 N.m / 0,89 lb.ft
Braking 2,5 mm² (12 AWG) 1,2 N.m / 0,89 lb.ft
Grounding 4,0 mm² (10 AWG) 1,7 N.m / 1.25 lb.ft
Control 0,5 to 1,5 mm² (20 to 14 AWG) 0,5 N.m / 0.37 lb.ft

Additional especifications
Maximum breaking current : 12,9 A
Minimum resistance for the brake resistor : 62 Ω
Recommended aR fuse : FNH00-35K-A
Recommended aR fuse : Not applicable
Recommended circuit breaker : ACW100H-FMU20-3
Recommended circuit breaker : Not applicable

Standards
Safety - UL 508C - Power conversion equipment.
- UL 840 - Insulation coordination including clearances and creepage distances
for electrical equipment.
- EN 61800-5-1 - Safety requirements electrical, thermal and energy.
- EN 50178 - Electronic equipment for use in power instalations
- EN 60204-1 - Safety of machinery. Electrical equipment of machines. Part
1: General requirements. Note: To have a machine in accordance with this
standard, the machine manufacturer is responsible for installing an emergency
stop device and supply disconnecting device.
- EN 60146 (IEC 146) - Semiconductor converters.

The information contained are reference


16/04/2020 Page 3 / 4
values. Subject to change without notice.
DATASHEET
Variable Speed Drives
- EN 61800-2 - Adjustable speed electrical power drive systems - Part 2:
General requirements - Rating especifications for low voltage adjustable
frequency AC power drive systems.
Electromagnetic compatibility EN 61800-3 - Adjustable speed electrical power drive systems - Part 3: EMC
product standard including specific test methods.
- EN 55011 - Limits and methods of measurement of radio disturbance
characteristics of industrial, scientific and medical (ISM) radio-frequency
equipment.
- CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment
- Eletromagnetic disturbance characteristics - Limits and methods of
measurement.
- EN 61000-4-2 - Eletromagnetic compatibility (EMC) - Part 4: Testing and
measurement techniques - Section 2: Eletrostatic discharge immunity test.
- EN 61000-4-3 - Eletromagnetic compatibility (EMC) - Part4: Testing
and measurement techniques - Section 3: Radiated, radio-frequency,
electromagnetic field immunity test.
- EN 61000-4-4 - Eletromagnetic compatibility (EMC) - Part4: Testing and
measurement techniques - Section 4: Electrical fast transient/burst immunity
test.
- EN 61000-4-5 - Eletromagnetic compatibility (EMC) - Part4: Testing and
measurement techniques - Section 5: Surge immunity test.
- EN 61000-4-6 - Eletromagnetic compatibility (EMC) - Part4: Testing and
measurement techniques - Section 6: Immunity to conducted disturbances,
induced by radio-frequency fields.
Mechanical construction - EN 60529 - Degrees of protection provided by enclosures (IP code).
- UL 50 - Enclosures for electrical equipment.
- EN 60529 e UL 50

Certifications

Notes
1) Orientative motor power, valid for WEG Motors standard of IV poles. The correct sizing must be done according to the nominal current of
the motor used, which must be less than or equal to the rated output current of the inverter;
2) Braking resistor is not included;
3) With category for emission level conducted;
4) Without derating and with minimum spaces;
5) For temperatures above the nominal and maximum temperature (with derating of current and minimum spaces);
____
6) For altitude over of specified;
7) All images are merely illustrative;
8) For more information, see the users manual of the CFW-11 (size B).

The information contained are reference


16/04/2020 Page 4 / 4
values. Subject to change without notice.
1 2 3 4 5 6

10,25 0,404
6 0,236
A

98,3 3,87

9 0,354
11,5 0,453
DETALHE B
ESCALA 1 : 2
150 5,906
189,59 7,464
227,01 8,937
B

315,5 12,421

300 11,811
C

70,15 2,762

MASSA BRUTA/GROSS WEIGHT kg MASSA LÍQUIDA/NET WEIGHT kg ESCALA/SCALE

E
RESUMO DE MODIFICAÇÕES EXECUTADO VERIFICADO LIBERADO DATA
ECM LOC VER
SUMMARY OF MODIFICATIONS EXECUTED CHECKED RELEASED DATE
EXEC CFW11/700
VERIF/CHECKED MEC B/ SIZE B
10003578752

SWD - A3
LIBER/RELEASED
IP21
DT LIBER/REL DT FOL/SHEET 1 1
Propriedade da WEG. Proibida reprodução sem autorização prévia./ WEG's property. Forbidden reproduction without previous authorization.

You might also like