Compresor Less Refrigerator
Compresor Less Refrigerator
Abstract
The thermoelectric effect has been proven as a source of cooling and small power generation as defined by
the Peltier-Seebeck effect. Thermoelectric modules, optimized by semiconductors, have been used for
temperature regulation by operating as a heat pump to maintain computing devices and integrated circuits at
optimum temperatures for improved processing efficiency. Thermoelectric modules have also been used to
capture microwatt electrical power from personal computing and other small scale devices by way of
utilizing the waste heat rejected through its heat sink. In modern data centers and server farms, water
cooling of electronics has been widely adapted as a more efficient cooling method than standard air
conditioning and ventilation systems due to its vastly larger thermal capacity. However, even high density
electronics cabinets and processing units are low level heat applications unfit for waste heat recovery by
standard thermodynamics cycles and heat pumps. When applying the thermoelectric effect to the
temperature difference between the heat source of the processing electronics and the heat sink of a water
cooling system, potential exists for practical and economic energy recovery.
This study demonstrates the feasibility of waste energy recovery from high power density electronics in data
centers and server farms by way of the practical and economic application of thermoelectricity. An
overview of thermoelectricity and the thermoelectric effect is given, including a review of semiconductor
materials and electronics cabinet cooling techniques. This report describes an investigation into the
efficiency of applying thermoelectricity to low temperature waste heat situations. Conclusions are presented
concerning the effectiveness of this application towards waste heat utilization for power recovery.
Saghar Mehdi ,IJSRM volum 4 issue 07 July 2016 [www.ijsrm.in] Page 4480
DOI: 10.18535/ijsrm/v4i7.17
Problem Description
The objective of this project is to analyze the
efficiency of applying TE devices to a data center
to assess the practicality and feasibility of waste
heat recovery. Data centers produce relatively low Cooling Fan
temperature waste heat when compared to other We are using two Cooling fans in our refrigerator
applications. The efficiency of the electrical which are respectively mounted on one heat sink
conductors used in thermoelectric waste heat each. The main purpose of a cooling fan is to
recovery can be used to assess the magnitude of Dissipate heat from the heat sink by taking in
power generation. Material selection is necessary fresh air. The fans used in this fridge work on 12
to optimize the efficiency of the thermoelectric volts DC and draws 0.18 amps. The power
modules while maintaining an economic solution consumption of each fan is 2.16 watts.
as well as selection of the optimum heat sink to
make execution of TE devices in a data center Insulation Material
realistic. Two materials have been used as insulator in
constructing the body of refrigerator. For
MATERIALS USED preventing air leakage proper fixing has been
In this project, various equipment’s and materials done. The two materials used are given as follows:
are used for the proper functioning and Thermocol
performance of the fridge. These equipment’s and
materials are as follows:
Peltier Unit
Thermocol
On the heat side of the peltier unit, a heat sink For evaluating the performance of our mini
along with the fan works to dissipate the heat from compressor-less solar fridge we tested it using a
the peltier unit in the outer environment. Fluke multimeter - 287 and data is recorded.
Afterwards graph was prepared for the same by
The Peltier thermoelectric Device will be so
taking the data from the multimeter.
arranged in a box with proper insulation system
and heat sink so that efficient cooling takes place
at all the time.
To turn off the fried, switch can be turned off.
Then the glowing led will also stop glowing
indicating no power for the fridge.
Battery charging
The batteries used in the fridge are charged from
the solar panels using a charge controller rated Working Fridge with temperature monitoring
12volts, 10 amps. The battery is connected to the As shown in the above figure, it can be observed
charge controllers which get supply from the solar that the refrigerator is operational as led is
panels and feeds it to the battery. glowing. Also in the background the multimeter is
showing the temperature inside the refrigerator
OBSERVATIONS simultaneously in the real
time.
As shown in the table, from the readings given Starting time: 26 minutes 2 seconds
following observations can be made: Final stable temperature: 16.9 °C
Starting temperature: 30.9 °C Final time: 48 minutes 8 seconds