Connect Alarm Panel Programming PowerSeries Pro - 30002600 PDF
Connect Alarm Panel Programming PowerSeries Pro - 30002600 PDF
Johnson Controls —
Connect Alarm
The alarm system need to be set up in order to connect to the server that
provides the connection service for the Connect Alarm smartphone application.
The alarm system can connect to the server over Ethernet (recommended) or
Cellular but not both.
2 Johnson Controls —
Connect Alarm – data consumption
There are four sessions that can be used. In this document integration session
1 is used though any session can be used. See “configuration of four
‘integration sessions’ ”.
3 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – HEX and ASCII data
To enter HEX data, perform the following:
Step 1 – Enter a section that allows for HEX data entries
Step 2 – Press [*] to enter HEX programming, the ‘Ready’ LED
will flash to indicate that HEX programming has been entered
Step 3 – Enter the required HEX data where switch from digits
to letters is done with '*‚ button :
1=A
2=B
3=C
4=D
5=E
6=F
Step 4 – Press [*] to exit HEX programming, the ‘Ready’ LED
will return to solid
Alphanumeric keyboard (for entering the APN or the domain
name of the server): to enter '.', change to ASCII (press the
'*' button and switch to ASCII with the <> buttons) and enter
046 and press the '*' button.
4 Johnson Controls —
Connect Alarm – Ethernet connection part 1
008 Static DNS 2 (set automatically when DHCP is enabled). Panel’s DNS IP can be seen in menu [851][989]
5 Johnson Controls —
Connect Alarm – Ethernet connection part 2
Menu Option Value/Name
010 Set option ‘2’ (Video Verification Enabled)
851 106 Enter URL of the cloud server: connect.tycomonitor.com (receiver 1 URL name)
425 Set options ‘3’ (integration Over Ethernet) and ‘5’ (Integration Protocol)
426 Set option ‘3’ (Real-Time Notification)
429 0517 (hex) -- 1303 (dec) Integration Notification Port
431 Enter URL of the cloud server: connect.tycomonitor.com (integration 1 URL name)
6 Johnson Controls —
Connect Alarm – Cellular connection part 1
7 Johnson Controls —
Connect Alarm – Cellular connection part 2
8 Johnson Controls —
Connect Alarm – group setting
Visual verification can be sent to two receivers in parallel using the group feature. It is useful in
case of connection to two power-manage servers or when using both SurGard receiver and
power-manage server and wanting that the visual verification will be sent to both servers.
Do the following:
In menu [851][018] enter the two receivers that will receive the video. For example, to
create a group of receivers 1 and 2, enter 0102.
9 Johnson Controls —
Connect Alarm – further steps and remarks
Connection to the cloud server is made via ITv2 and Fibro protocols in parallel to ensure
smooth and quick app reactions. This is different from ‘neo go’ application that required ITv2
connection only.
In case of concurrent connection with SurGard, both SurGard and power-manage cloud server
should be getting events simultaneously
Once fully programmed, please reboot panel (disconnect all power supplies including AC and
battery)
Make sure that non-used receivers IP fields are set to 0.0.0.0 (Ethernet Receiver 1 Address:
[851][103], Ethernet Receiver 2 Address: [851][113], Cellular Receiver 1 Address: [851][203],
Cellular Receiver 2 Address: [851][213])
10 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – further steps and remarks
11 Johnson Controls —
Connect Alarm – configuration of four ‘integration sessions’
If Integration session 1 in panel is used for different purpose, then Session 2, 3 or 4 can be used instead.
12 Johnson Controls —
Connect Alarm – configuration of four receivers
If the receiver 1 (for Ethernet connection) or receiver 3 (for cellular connection) are used for different
purpose than Connect Alarm application can use the other receivers (2 or 4).
[300] [001] [300] [002] [300] [003] [300] [004] “panel/receiver communication path” (not used
paths should be configured to [01] “Phone Line”)
13 Johnson Controls —
Connect Alarm Activation
Before end user uses the app for the first time, installer activation is required
Activation can be done in one of two options:
Select a panel from the power-manage web GUI in Panels page and press the ACTIVATE button
Notes:
The ACTIVATE button appears in panels that are not activated.
If installer code changes then the panel needs to be re-activated
The user-app activation which is done by the ‘connect alarm activation’ mobile-app can be performed only
when there is an active connection between the power-manage server and the Neo panel. When using a
GPRS/Cellular Neo panel, most of the time the panel is disconnected (the panel is connected when user
is logged in the user-app ‘connect alarm’ and up to 5 minutes after exiting installer menu) from the server
and therefore the panel cannot be activated. To reconnect the panel to the server please send to the
panel the following SMS: connectXXXXXXXXXXXX05205917105501304neo go or exit from installer
code.
The XXXXXXXXXXXX should be replaced with the panel ID which is located in installer menu
[851][422] (also called ‘panel webname’ in the ‘connect alarm activation’ or ‘panel ID’ in the ‘connect
alarm’ application).
Sending the SMS will cause the panel to connect within few seconds to the server so the activation
process can complete
15 Johnson Controls —
Connect Alarm – App installation and first use
Install ‘ConnectAlarm’ app from Google Play Store or Apple App store
View the ‘Connect Alarm Video Tutorial’ in the web page http://dsc.com/connect-alarm/ for instruction how
to start the application for the first time and how to control the panel using the app.
16 Johnson Controls —
Contact information
Technical support:
30002600
17 Johnson Controls —