H Series Serial Driver
H Series Serial Driver
1 System Configuration....................................................................................................... 3
2 Selection of External Device .......................................................................................... 10
3 Example of Communication Setting ............................................................................... 11
4 Setup Items .................................................................................................................... 95
5 Cable Diagram ............................................................................................................. 100
6 Supported Device......................................................................................................... 165
7 Device Code and Address Code.................................................................................. 172
8 Error Messages............................................................................................................ 175
1
H Series Serial Driver
PREFACE
This manual describes how to connect the Display and the External Device.
In this manual, the connection procedure will be described by following the below sections:
1 System Configuration
)"1 System Configuration" (page 3)
This section shows the types of External
Devices which can be connected and SIO
type.
Setup Items
4
This section describes communication
)"4 Setup Items" (page 95)
setup items on the Display.
Set communication settings of the Display
with GP-Pro EX or in off-line mode.
5 Cable Diagram
)"5 Cable Diagram" (page 100)
This section shows cables and adapters
for connecting the Display and the
External Device.
Operation
1 System Configuration
The system configuration in the case when the External Device of Hitach IES Co., Ltd. and the Display are
connected is shown.
Setting Cable
Series CPU Link I/F SIO Type
Example Diagram
Setting Cable
Port on the CPU
H-20, H-28, H-40, H-64 RS232C Example 1 Diagram 1
unit (page 11) (page 100)
Setting Cable
Port on the CPU
H-252C(CPU22-02HC)*1 *2 RS232C Example 1 Diagram 1
unit (page 11) (page 100)
Setting Cable
Port on the CPU
RS232C Example 1 Diagram 1
unit (page 11) (page 100)
H-300(CPU-03Ha)*1
Setting Cable
H H-700(CPU-07Ha)*1
RS232C Example 2 Diagram 1
(Procedure 1) H-2000(CPU-20Ha)*1 (page 13) (page 100)
H-2002(CPU2-20H)*1 COMM-H
COMM-2H Setting Cable
RS422/485
Example 3 Diagram 2
(4wire) (page 15) (page 102)
Setting Cable
Port on the CPU
RS232C Example 1 Diagram 1
unit (page 11) (page 100)
H-302(CPU2-03H)*1
Setting Cable
H-702(CPU2-07H)*1
RS232C Example 2 Diagram 1
H-4010(CPU3-40H)*1 (page 13) (page 100)
H-1002(CPU2-10H)*1 COMM-2H
Setting Cable
RS422/485
Example 3 Diagram 2
(4wire) (page 15) (page 102)
Setting Cable
Series CPU Link I/F SIO Type
Example Diagram
EH-150(EH-CPU104)
EH-150(EH-CPU104A) Serial port 1 on
Setting Cable
EH-150(EH-CPU208) the CPU unit
RS232C Example 6 Diagram 3
EH-150(EH-CPU208A) Serial port 2 on (page 21) (page 106)
EH-150(EH-CPU308) the CPU unit
EH-150(EH-CPU316)
Setting Cable
RS232C Example 6 Diagram 3
(page 21) (page 106)
Setting Cable
Port1 on the
RS232C Example 9 Diagram 12
EH-SIO unit*3 (page 27) (page 152)
Setting Cable
RS232C*4 Example 10 Diagram 12
EH-150(EH-CPU516) (page 29) (page 152)
EH-150(EH-CPU548) Setting Cable
Port2 on the RS422/485
Example 11 Diagram 6
EH-SIO unit*3 (4wire)*4 (page 31) (page 119)
Setting Cable
RS422/485
Example 12 Diagram 7
(2wire)*4 (page 33) (page 123)
Setting Cable
Series CPU Link I/F SIO Type
Example Diagram
Setting Cable
EH-150(EH-CPU104A) Serial port 1 on
RS232C Example 13 Diagram 3
EH-150(EH-CPU208A) the CPU unit (page 35) (page 106)
Setting Cable
RS232C Example 13 Diagram 3
EH-150(EH-CPU308A) (page 35) (page 106)
EH-150(EH-CPU316A)
Setting Cable
EH-150(EH-CPU448) Serial port 1 on RS422/485
Example 14 Diagram 4
EH-150(EH-CPU448A) the CPU unit (4wire) (page 37) (page 108)
EH-150(EH-CPU516)
EH-150(EH-CPU548) Setting Cable
RS422/485
Example 15 Diagram 5
EH-150 (2wire) (page 39) (page 112)
(Procedur
e 2) Setting Cable
Port1 on the
RS232C Example 16 Diagram 12
EH-SIO unit*3 (page 41) (page 152)
Setting Cable
RS232C*4 Example 17 Diagram 12
EH-150(EH-CPU516) (page 43) (page 152)
EH-150(EH-CPU548) Setting Cable
Port2 on the RS422/485
Example 18 Diagram 6
EH-SIO unit*3 (4wire)*4 (page 45) (page 119)
Setting Cable
RS422/485
Example 19 Diagram 7
(2wire)*4 (page 47) (page 123)
Setting Cable
Port 1 on the
RS232C Example 20 Diagram 3
CPU unit (page 49) (page 106)
MICRO-EH(EH-A23)*5
Setting Cable
MICRO-EH(EH-D23)*5 RS422/485
Example 21 Diagram 8
MICRO-EH(EH-A28)*5 (4wire) (page 51) (page 130)
MICRO-EH(EH-D28)*5 Port 2 on the
CPU unit Setting Cable
RS422/485
MICRO- Example 22 Diagram 9
(2wire) (page 53) (page 134)
EH
(Procedure
Setting Cable
1) Port on the CPU
RS232C Example 20 Diagram 3
unit (page 49) (page 106)
Setting Cable
Series CPU Link I/F SIO Type
Example Diagram
Setting Cable
Port 1 on the
RS232C Example 26 Diagram 3
CPU unit (page 61) (page 106)
MICRO-EH(EH-A23)*5
Setting Cable
MICRO-EH(EH-D23)*5 RS422/485
Example 27 Diagram 8
MICRO-EH(EH-A28)*5 (4wire) (page 63) (page 130)
MICRO-EH(EH-D28)*5 Port 2 on the
CPU unit Setting Cable
RS422/485
MICRO- Example 28 Diagram 9
(2wire) (page 65) (page 134)
EH
(Procedure
Setting Cable
2) Port on the CPU
RS232C Example 26 Diagram 3
unit (page 61) (page 106)
Setting Cable
Serial port on
EH-WD10DR RS232C Example 32 Diagram 3
the CPU unit (page 73) (page 106)
Setting Cable
Web RS232C Example 40 Diagram 3
controller (page 89) (page 106)
(Procedure Setting Cable
1 and 2) Serial port on RS422/485
EH-WA23DR Example 41 Diagram 13
the CPU unit (4wire) (page 91) (page 153)
Setting Cable
RS422/485
Example 42 Diagram 14
(2wire) (page 93) (page 158)
Setting Cable
Series CPU Link I/F SIO Type
Example Diagram
Setting Cable
RS232C Example 33 Diagram 3
(page 75) (page 106)
Setting Cable
Serial port on RS422/485
Example 34 Diagram 4
the CPU unit (4wire) (page 77) (page 108)
Setting Cable
R422/S485
Example 35 Diagram 5
(2wire) (page 79) (page 112)
EHV-CPU128
EHV Setting Cable
EHV-CPU64 Port 1 on the
(Procedure RS232C Example 36 Diagram 12
EHV-CPU32 EH-SIO unit*3 (page 81) (page 152)
1 and 2)
EHV-CPU16
Setting Cable
RS232C Example 37 Diagram 12
(page 83) (page 152)
Setting Cable
Port 2 on the RS422/485
Example 38 Diagram 6
EH-SIO unit*3 (4wire) (page 85) (page 119)
Setting Cable
RS422/485
Example 39 Diagram 7
(2wire) (page 87) (page 123)
*2 When the peripheral port 2 on the CPU unit is used, CNCOM-05 conversion cable by Hitachi IES Co., Ltd. needs to be used
between the 8 pin connector and D-sub 15 pin connecter.
*3 Version 2.0 or later of the EH-SIO software supports Procedure 1; version 2.1 or later supports Procedure 2. Furthermore,
only EH-CPU548(Ver.E402 or later)/EH-CPU516(Ver.E202 or later) can use EH-SIO.
*4 Bit8 is used for interface selection of Port2 (RS232C or RS422/485).
*5 Model No. of the External Device "" differs depending on the specification of each External Device.
*6 Communication board (RS232C).Can be used in the CPU of which version is Ver.0101 or later.
*7 Communication board (RS422/RS485).Can be used in the CPU of which version is Ver.0100 or later.
Usable port
Usable port
Series
RS-232C RS-422/485(4 wire) RS-422/485(2 wire)
*1
COM1 , COM2,
PS-2000B - -
COM3*1, COM4
PS-3450A, PS-3451A COM1, COM2*1*2 COM2*1*2 COM2*1*2
PS-3650A, PS-3651A COM1*1 - -
PS-3700A (Pentium®4-M) COM1*1, COM2 , *1
COM3*2 COM3*2
PS-3710A COM3*2 , COM4
PS-3711A COM1*1, COM2*2 COM2*2 COM2*2
COM1*1*2, COM2*1,
PL-3000B COM1*1*2 COM1*1*2
COM3, COM4
*1 The RI/5V can be switched. Please switch with the change switch of IPC.
*2 It is necessary to set up the SIO type with the Dip switch. Please set up as follows according to SIO
type to be used.
Examples of communication settings of the Display and the External Device, recommended by Digital
Electronics Corp., are shown.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
*1 To enable the termination resistance, enter B100(H). In addition, enter the Station No. set on the Display in
lower 2 digits of A100 (or B100)
Mode Setting Switch
DIP Switch Settings Description
SW03 ON
Port 1 Transmission Speed: 19,200 bps
SW04 OFF
SW05 ON Port 1 Operation: Specified port
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
*1 To enable the termination resistance, enter B200(H). In addition, enter the Station No. set on the Display in
lower 2 digits of A200 (or B200)
Mode Setting Switch
DIP Switch Settings Description
SW03 ON
Port 1 Transmission Speed: 19,200 bps
SW04 OFF
SW05 ON Port 1 Operation: Specified port
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Always OFF
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Interface Type: RS232C
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
*1 To enable the termination resistance, enter F100(H). In addition, enter the Station No. set on the Display in
lower 2 digits of E100 (or F100)
Mode Setting Switch
DIP Switch Settings Description
SW03 ON
Port 1 Transmission Speed: 19,200 bps
SW04 OFF
SW05 ON Port 1 Operation: Specified port
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
*1 To enable the termination resistance, enter F200(H). In addition, enter the Station No. set on the Display in
lower 2 digits of E200 (or F200)
Mode Setting Switch
DIP Switch Settings Description
SW03 ON
Port 1 Transmission Speed: 19,200 bps
SW04 OFF
SW05 ON Port 1 Operation: Specified port
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Always OFF
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Interface Type: RS232C
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch inside the front cover of the External Device to enable the communication with the ladder
software.
Set as the following table.
DIP Switch Settings Description
SW01 ON
Transmission Speed: 19,200 bps
SW02 OFF
Please refer to the manual of the External Device for more details about other
SW03 OFF transmission speed settings.
SW04 OFF
2. Set 0000(H) in I/O No.WRF01A and turn I/O No.R7F6 ON to write the settings in the FLASH memory in the
External Device.
• WRF01A
Limit Bit Settings Description
15 0 Procedure 1
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 0 Procedure 1
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 0 Procedure 1
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 0 Procedure 1
13 0 Station No.: Disable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 0 Procedure 1
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 0 Procedure 1
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch inside the front cover of the External Device to enable the communication with the ladder
software.
Set as the following table.
DIP Switch Settings Description
SW01 ON
Speed: 19,200 bps
SW02 OFF
Please refer to the manual of the External Device for more details about other
SW03 OFF
transmission speed settings.
SW04 OFF
2. Set 8000(H) in I/O No.WRF01A and turn I/O No.R7F6 ON to write the settings in the FLASH memory in the
External Device.
• WRF01A
Limit Bit Settings Description
15 1 Procedure 2
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 1 Procedure 2
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 1 Procedure 2
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 1 Procedure 2
13 0 Station No.: Disable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 1 Procedure 2
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Set the following communication settings in I/O No.WRF03D and turn I/O No.R7F6 ON to write the settings
in the FLASH memory in the External Device.
• WRF03D
Limit Bit Settings Description
15 1*1 Setting Change Request
14 1 Procedure 2
13 1 Station No.: Enable
Transmission speed: 19,200bps
11 to 8 0010(H) Please refer to the manual of the External Device for more details about other
transmission speed settings.
7 to 0 0 Station No.*2
*1 For communication settings, set "1". It will be changed to "0" when turning the power of the External
Device again.
*2 Set the Station No. with BCD 2 digits. Bit position of 7 to 4 corresponds to the digit of 10, and of 3 to
0 corresponds to the digit of 1.
• R7F6
Limit Bit Settings Description
- 1 Writing in FLASH memory
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
Please refer to the manual of the Web controller for more details.
1. If you set the operation mode setting switch of the External Device as follows, the temporary IP address of the
Ethernet port will be set to 192.168.0.1.
<Operation Mode Setting Switch>
•Set the rotary switch to "2"
2. Use the LAN cable to connect the Ethernet port of PC to the Ethernet port of the Web controller.(connect via
HUB or with the cross cable directly.)
3. Enter "http://192.168.0.1/mwconfig.cgi" in the address input box of the Web Browser to access the External
Device.
To access, you need to set the upper 3 bytes of PC's IP address to 192.168.0.. (ex. 192.168.0.10)
4. Login in the displayed System Configuration Login screen.
5. Select [Serial Protocol]-[Passive HIProtocol] from [System Configuration] on the displayed screen for
communication settings. After settings, click [SET] to confirm the setting values.
Serial-Passive HIProtocol
Setup Items Setting Value
Interface Type RS232C
Transmission Control Procedure Procedure1 1:1*1
Transmission Speed 19.2 kbps
Station No. 0
*1 To use Procedure 2, select [Procedure2 1:1].
6. Set the operation mode setting switch of the External Device and turn ON the power again.
<Operation Mode Setting Switch>
•Set the rotary switch to "0"
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Start the programming software and create the project. The project is displayed in the offline mode.
2. Select [Editor Communication Setting] from the [Tool] menu to display the communication setting dialog
box.
3. Select either "USB" or "Serial" for the communication method to transfer the communication setting to the
External Device and click [Setting].
4. Use the USB cable or serial cable (by Hitachi IES Co., Ltd.) to connect PC to the External Device.
5. Select [Mode Change] - [Online] from the [Online] menu to move to the online mode.
6. Select [CPU Settings] - [Serial Communication Settings] from the [Tool] menu to perform the communication
settings.
• CPU Communication Settings (Serial Communication Settings)
Setup Items Settings
Serial Communication Settings Specified
Port Type RS232C
Speed 19.2 kbps
Communication Procedure Procedure 1 (1:1)*1
*1 To use Procedure 2 for communication, select [Procedure 2 (1:1)].
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Start the programming software and create the project. The project is displayed in the offline mode.
2. Select [Editor Communication Setting] from the [Tool] menu to display the communication setting dialog
box.
3. Select either "USB" or "Serial" for the communication method to transfer the communication setting to the
External Device and click [Setting].
4. Use the USB cable or serial cable (by Hitachi IES Co., Ltd.) to connect PC to the External Device.
5. Select [Mode Change] - [Online] from the [Online] menu to move to the online mode.
6. Select [CPU Settings] - [Serial Communication Settings] from the [Tool] menu to perform the communication
settings.
• CPU Communication Settings (Serial Communication Settings)
Setup Items Settings
Serial Communication Settings Specified
Port Type RS422/RS485
Speed 19.2 kbps
Communication Procedure Procedure 1 (1:n)*1
Station No. Enter the Station No. set on the display.*2
*1 To use Procedure 2 for communication, select [Procedure 2 (1:n)].
*2 If you set the Station No. to "None", communication is not available.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Start the programming software and create the project. The project is displayed in the offline mode.
2. Select [Editor Communication Setting] from the [Tool] menu to display the communication setting dialog
box.
3. Select either "USB" or "Serial" for the communication method to transfer the communication setting to the
External Device and click [Setting].
4. Use the USB cable or serial cable (by Hitachi IES Co., Ltd.) to connect PC to the External Device.
5. Select [Mode Change] - [Online] from the [Online] menu to move to the online mode.
6. Select [CPU Settings] - [Serial Communication Settings] from the [Tool] menu to perform the communication
settings.
• CPU Communication Settings (Serial Communication Settings)
Setup Items Settings
Serial Communication Settings Specified
Port Type RS422/RS485
Speed 19.2 kbps
Communication Procedure Procedure 1 (1:n)*1
Station No. Enter the Station No. set on the display.*2
*1 To use Procedure 2 for communication, select [Procedure 2 (1:n)].
*2 If you set the Station No. to "None", communication is not available.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
• Communication Setting Switch 1 (for Port 1)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Always OFF
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more
details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
• Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 OFF Interface Type: RS232C
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more
details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
• Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485C
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more
details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
1. Use the DIP switch on the EH-SIO for communication settings.
• Communication Setting Switch 2 (for Port 2)
DIP Switch Settings Description
01 OFF
02 ON Speed: 19,200 bps
Please refer to the manual of the External Device for more details about other
03 ON
transmission speed settings.
04 ON
05 OFF Transmission character configuration settings
06 ON Data Length: 7 bits
Stop Bit: 1 bit
07 OFF Parity: Even
08 ON Interface Type: RS422/RS485C
2. Ladder program is required for initial settings. Please refer to the manual of the External Device for more
details.
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
Please refer to the manual of the Web controller for more details.
1. If you set the operation mode setting switch of the External Device as follows, the temporary IP address of the
Ethernet port will be set to 192.168.0.1.
<Operation Mode Setting Switch>
•Set only the DIP switch4 to ON
2. Use the LAN cable to connect the Ethernet port of PC to the Ethernet port of the Web controller.(connect via
HUB or with the cross cable directly.)
3. Enter "http://192.168.0.1/mwconfig.cgi" in the address input box of the Web Browser to access the External
Device.
To access, you need to set the upper 3 bytes of PC's IP address to 192.168.0.. (ex. 192.168.0.10)
4. Login in the displayed System Configuration Login screen.
5. Select [Serial Protocol]-[Passive HIProtocol] from [System Configuration] on the displayed screen for
communication settings. After settings, click [SET] to confirm the setting values.
Serial-Passive HIProtocol
Setup Items Setting Value
Interface Type RS232C
Transmission Control Procedure Procedure1 1:1*1
Transmission Speed 19.2 kbps
Station No. 0
*1 To use Procedure 2, select [Procedure2 1:1].
6. Set the operation mode setting switch of the External Device and turn ON the power again.
<Operation Mode Setting Switch>
•Set all the DIP switch to OFF
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
Please refer to the manual of the Web controller for more details.
1. If you set the operation mode setting switch of the External Device as follows, the temporary IP address of the
Ethernet port will be set to 192.168.0.1.
<Operation Mode Setting Switch>
•Set only the DIP switch4 to ON
2. Use the LAN cable to connect the Ethernet port of PC to the Ethernet port of the Web controller.(connect via
HUB or with the cross cable directly.)
3. Enter "http://192.168.0.1/mwconfig.cgi" in the address input box of the Web Browser to access the External
Device.
To access, you need to set the upper 3 bytes of PC's IP address to 192.168.0.. (ex. 192.168.0.10)
4. Login in the displayed System Configuration Login screen.
5. Select [Serial Protocol]-[Passive HIProtocol] from [System Configuration] on the displayed screen for
communication settings. After settings, click [SET] to confirm the setting values.
Serial-Passive HIProtocol
Setup Items Setting Value
Interface Type RS-422/485
Transmission Control Procedure Procedure1 1:1*1
Transmission Speed 19.2 kbps
Station No. 0
*1 To use Procedure 2, select [Procedure2 1:1].
6. Set the operation mode setting switch of the External Device and turn ON the power again.
<Operation Mode Setting Switch>
•Set all the DIP switch to OFF
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
Procedure
Please refer to the manual of the Web controller for more details.
1. If you set the operation mode setting switch of the External Device as follows, the temporary IP address of the
Ethernet port will be set to 192.168.0.1.
<Operation Mode Setting Switch>
• Set only the DIP switch4 to ON
2. Use the LAN cable to connect the Ethernet port of PC to the Ethernet port of the Web controller.(connect via
HUB or with the cross cable directly.)
3. Enter "http://192.168.0.1/mwconfig.cgi" in the address input box of the Web Browser to access the External
Device.
To access, you need to set the upper 3 bytes of PC's IP address to 192.168.0.. (ex. 192.168.0.10)
4. Login in the displayed System Configuration Login screen.
5. Select [Serial Protocol]-[Passive HIProtocol] from [System Configuration] on the displayed screen for
communication settings. After settings, click [SET] to confirm the setting values.
Serial-Passive HIProtocol
Setup Items Setting Value
Interface Type RS-422/485
Transmission Control Procedure Procedure1 1:1*1
Transmission Speed 19.2 kbps
Station No. 0
*1 To use Procedure 2, select [Procedure2 1:1].
6. Set the operation mode setting switch of the External Device and turn ON the power again.
<Operation Mode Setting Switch>
•Set all the DIP switch to OFF
4 Setup Items
Set communication settings of the Display with GP-Pro Ex or in off-line mode of the Display.
The setting of each parameter must be identical to that of External Device.
)"3 Example of Communication Setting" (page 11)
Device Setting
To display the setting screen, click ([Setting]) of the External Device you want to set from [Device-Specific
Settings ] of [Device/PLC Settings ].
When connecting multiple External Devices, you can click from [Device-Specific Settings] of [Device/PLC
Settings] to add the External Device which is available to set.
• Refer to the Maintenance/Troubleshooting manual for information on how to enter off-line mode
or about the operation.
Communication Settings
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings] in the off-line
mode. Touch the External Device you want to set from the displayed list.
To make the communication settings correctly, confirm the serial interface specifications of
SIO Type Display unit for [SIO Type].
We cannot guarantee the operation if a communication type that the serial interface does
not support is specified.
For details concerning the serial interface specifications, refer to the manual for Display
unit.
Speed Select speed between the External Device and the Display.
Data Length Select data length.
Parity Select how to check parity.
Stop Bit Select stop bit length.
Select the communication control method to prevent overflow of transmission and
Flow Control
reception data.
Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the
Timeout
response from the External Device.
Device Setting
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings]. Touch the
External Device you want to set from the displayed list, and touch [Device Settings].
Option
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings]. Touch the
External Device you want to set from the displayed list, and touch [Option].
5 Cable Diagram
The cable diagram shown below may be different from the cable diagram recommended by Hitachi IES Co., Ltd.
Please be assured there is no operational problem in applying the cable diagram shown in this manual.
• The FG pin of the main body of the External Device must be D-class grounded. Please refer to the manual of
the External Device for more details.
• SG and FG are connected inside the Display. When connecting SG to the External Device, design the system
not to form short-circuit loop.
• Connect the isolation unit, when communication is not stabilized under the influence of a noise etc..
Cable Diagram 1
Display
Cable*1 Remarks
(Connection Port)
*2 Only the COM port which can communicate by RS-232C can be used.
) COM Port of IPC (page 8)
Cable Diagram 2
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield Terminal block
TERM Signal name
Display RDA TXDP
CA3-ADPCOM-01
RDB TXDN
SDA RXDP Terminal
resistance
CA3-ADPTRM-01 SDB RXDN 120 Ω (1/2W)
SG TXDG
FG RXDG
• 1:n Connection
External Device External Device
Signal name Shield Terminal block Terminal block
Shield
TERM Signal name Signal name
Display RDA TXDP TXDP
CA3-ADPCOM-01 Terminal
RDB TXDN TXDN resistance
120 Ω (1/2W)
SDA RXDP RXDP
CA3-ADPTRM-01 SDB RXDN RXDN
SG TXDG TXDG
FG RXDG RXDG
• 1:n Connection
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield Terminal block
TERM Signal name
Display RDA TXDP
CA4-ADPONL-01 Terminal
RDB TXDN resistance
120 Ω (1/2W)
SDA RXDP
CA3-ADPTRM-01 SDB RXDN
SG TXDG
FG RXDG
• 1:n Connection
External Device External Device
Signal name Shield Terminal block Terminal block
Shield
TERM Signal name Signal name
Display RDA TXDP TXDP
CA4-ADPONL-01 Terminal
RDB TXDN TXDN resistance
120 Ω (1/2W)
SDA RXDP RXDP
CA3-ADPTRM-01 SDB RXDN RXDN
SG TXDG TXDG
FG RXDG RXDG
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
D-Sub 9 pin (plug) External Device External Device
Pin Signal name Shield Terminal block Terminal block
Shield
CA4-ADPONL-01 1 TERMRX Signal name Signal name
Display 2 RDA TXDP TXDP
Terminal
7 RDB TXDN TXDN resistance
3 SDA RXDP RXDP 120 Ω (1/2W)
8 SDB RXDN RXDN
5 SG TXDG TXDG
9 TERMTX RXDG RXDG
Shell FG
Cable Diagram 3
Display
Cable*1 Remarks
(Connection Port)
*2 Only the COM port which can communicate by RS-232C can be used.
) COM Port of IPC (page 8)
External Device
Display EH-VCB02 RJ-45 connector
B. When using the cable (WVCB02H) by Hitachi IES Co., Ltd. and the conversion cable (EH-RS05) by Hitachi
IES Co., Ltd.
External Device
Display WVCB02H RJ-45 connector
EH-RS05
C. When using your own cable 1 and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Shield External Device
Pin Signal name Pin Signal name RJ-45 conncetor
EH-RS05
2 RD(RXD) 2 SD
Display 3 SD(TXD) 3 RD
6 DR(DSR) 5 CS
4 ER(DTR) 7 DR
5 SG 9 SG
7 RS(RTS) 8 PHL
8 CS(CTS) 4 RS
Shell FG 14 PV12
D. When using your own cable 2 and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug) External Device
Shield RJ-45 conncetor
Pin Signal name Pin Signal name EH-RS05
2 RD(RXD) 2 SD
Display 3 SD(TXD) 3 RD
6 DR(DSR) 5 CS
4 ER(DTR) 7 DR
5 SG 9 SG
7 RS(RTS) 8 PHL
8 CS(CTS) 4 RS
Shell FG 14 PV12
Cable Diagram 4
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face, your own cable and the conversion cable (EH-RS05) by Hitachi IES Co.,
Ltd.
• 1:1 Connection
External Device
Signal name D-Sub 15 pin (plug)
Shield
TERM Pin Signal name
External Device
Display RDA 14 TX RJ-45 conncetor
CA3-ADPCOM-01
RDB 2 TXN EH-RS05
SDA 7 RX
CA3-ADPTRM-01 SDB 3 RXN
SG 9 SG
FG
• 1:n Connection
External Device
Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield
TERM Pin Signal name Pin Signal name
Display External Device
RDA 14 TX 14 TX RJ-45 conncetor
CA3-ADPCOM-01
RDB 2 TXN 2 TXN EH-RS05
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 3 RXN 3 RXN
SG 9 SG 9 SG
FG
*For more information about the termination resistance, contact Hitachi IES Co., Ltd.
B. When using your own cable and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
• 1:1 Connection
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Shield
Pin Signal name Pin Signal name External Device
1 RDA 14 TX RJ-45 conncetor
2 RDB 2 TXN EH-RS05
Display 3 SDA 7 RX
7 SDB 3 RXN
5 SG 9 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
*For more information about the termination resistance, contact Hitachi IES Co., Ltd.
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face, your own cable and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
TERM Pin Signal name
Display External Device
RDA 14 TX
CA4-ADPONL-01 RJ-45 conncetor
RDB 2 TXN EH-RS05
SDA 7 RX
CA3-ADPTRM-01 SDB 3 RXN
SG 9 SG
FG
• 1:n Connection
*For more information about the termination resistance, contact Hitachi IES Co., Ltd.
D. When using the online adapter (CA4-ADPONL-01), your own cable and the conversion cable (EH-RS05) by
Hitachi IES Co., Ltd.
• 1:1 Connection
D-Sub 9 pin (plug)
External Device
Pin Signal name D-Sub 15 pin (plug)
CA4-ADPONL-01 Shield
1 TERMRX Pin Signal name External Device
Display 2 RDA 14 TX RJ-45 conncetor
7 RDB 2 TXN EH-RS05
3 SDA 7 RX
8 SDB 3 RXN
5 SG 9 SG
9 TERMTX
Shell FG
• 1:n Connection
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield Shield
CA4-ADPONL-01 1 TERMRX Pin Signal name Pin Signal name
External Device
Display 2 RDA 14 TX 14 TX RJ-45 conncetor
7 RDB 2 TXN 2 TXN EH-RS05
3 SDA 7 RX 7 RX
8 SDB 3 RXN 3 RXN
5 SG 9 SG 9 SG
9 TERMTX
Shell FG
*For more information about the termination resistance, contact Hitachi IES Co., Ltd.
Cable Diagram 5
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face, your own cable and the conversion cable (EH-RS05) by Hitachi IES Co.,
Ltd.
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
External Device
TERM Pin Signal name RJ-45 conncetor
Display RDA 14 TX
CA3-ADPCOM-01 EH-RS05
RDB 2 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 3 RXN
SG 9 SG
FG
• 1:n Connection
B. When using your own cable and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
• 1:1 Connection
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Terminal Shield External Device
resistance Pin Signal name Pin Signal name
100 Ω (1/2W) RJ-45 conncetor
1 RDA 14 TX EH-RS05
2 RDB 2 TXN
Display 3 SDA 7 RX
7 SDB 3 RXN
5 SG 9 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug)
Terminal Shield External Device
resistance Pin Signal name Pin Signal name Pin Signal name RJ-45 conncetor
100 Ω (1/2W)
1 RDA 14 TX 14 TX EH-RS05
2 RDB 2 TXN 2 TXN
Display 3 SDA 7 RX 7 RX
7 SDB 3 RXN 3 RXN
5 SG 9 SG 9 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face, your own cable and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
External Device
TERM Pin Signal name RJ-45 conncetor
Display RDA 14 TX
CA4-ADPONL-01 EH-RS05
RDB 2 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 3 RXN
SG 9 SG
FG
• 1:n Connection
External Device External Device
Signal name Shield D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug) External Device
TERM Pin Signal name Pin Signal name RJ-45 conncetor
Display RDA 14 TX 14 TX EH-RS05
CA4-ADPONL-01
RDB 2 TXN 2 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 3 RXN 3 RXN
SG 9 SG 9 SG
FG
D. When using the online adapter (CA4-ADPONL-01), your own cable and the conversion cable (EH-RS05) by
Hitachi IES Co., Ltd.
• 1:1 Connection
D-Sub 9 pin (plug)
External Device
Pin Signal name Shield D-Sub 15 pin (plug) External Device
CA4-ADPONL-01 1 TERMRX Pin Signal name RJ-45 conncetor
Display 2 RDA 14 TX EH-RS05
7 RDB 2 TXN
3 SDA 7 RX
8 SDB 3 RXN
5 SG 9 SG
9 TERMTX
Shell FG
• 1:n Connection
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name Shield D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug)
CA4-ADPONL-01 1 TERMRX External Device
Pin Signal name Pin Signal name
RJ-45 conncetor
Display 2 RDA 14 TX 14 TX EH-RS05
7 RDB 2 TXN 2 TXN
3 SDA 7 RX 7 RX
8 SDB 3 RXN 3 RXN
5 SG 9 SG 9 SG
9 TERMTX
Shell FG
E. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face, your own cable and the conversion cable (EH-RS05) by Hitachi IES Co.,
Ltd.
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
External Device
TERM Pin Signal name RJ-45 conncetor
Display RDA 7 RX
CA3-ADPCOM-01 EH-RS05
RDB 3 RXN
SDA 14 TX
CA3-ADPTRM-01 SDB 2 TXN
SG 9 SG
FG
• 1:n Connection
External Device External Device
Signal name Shield D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug)
TERM External Device
Pin Signal name Pin Signal name RJ-45 conncetor
Display RDA 7 RX 7 RX
CA3-ADPCOM-01 EH-RS05
RDB 3 RXN 3 RXN
SDA 14 TX 14 TX
CA3-ADPTRM-01 SDB 2 TXN 2 TXN
SG 9 SG 9 SG
FG
F. When using your own cable and the conversion cable (EH-RS05) by Hitachi IES Co., Ltd.
• 1:1 Connection
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Terminal Shield External Device
resistance Pin Signal name Pin Signal name RJ-45 conncetor
100Ω (1/2W)
1 DATA+ 7 RX EH-RS05
2 DATA- 3 RXN
Display 3 NC 14 TX
7 NC 2 TXN
5 GND(SG) 9 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Terminal Shield Shield External Device
resistance Pin Signal name Pin Signal name Pin Signal name RJ-45 conncetor
100Ω (1/2W)
1 DATA+ 7 RX 7 RX EH-RS05
2 DATA- 3 RXN 3 RXN
Display 3 NC 14 TX 14 TX
7 NC 2 TXN 2 TXN
5 GND(SG) 9 SG 9 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
Cable Diagram 6
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Signal name External Device
Shield
TERM Pin Signal name
Display RDA 1 SD+
CA3-ADPCOM-01
RDB 2 SD-
SDA 3 RD+
CA3-ADPTRM-01 SDB 4 RD-
SG 6 SG
FG 5 TERM
• 1:n Connection
Signal name External Device External Device
Shield Shield
TERM Pin Signal name Pin Signal name
Display RDA 1 SD+ 1 SD+
CA3-ADPCOM-01
RDB 2 SD- 2 SD-
SDA 3 RD+ 3 RD+
CA3-ADPTRM-01 SDB 4 RD- 4 RD-
SG 6 SG 6 SG
FG 5 TERM 5 TERM
• 1:n Connection
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
D-Sub 9 pin (plug)
Pin Signal name External Device External Device
Shield Shield
CA4-ADPONL-01 1 TERMRX Pin Signal name Pin Signal name
Display 2 RDA 1 SD+ 1 SD+
7 RDB 2 SD- 2 SD-
3 SDA 3 RD+ 3 RD+
8 SDB 4 RD- 4 RD-
5 SG 6 SG 6 SG
9 TERMTX 5 TERM 5 TERM
Shell FG
Cable Diagram 7
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Signal name Shield External Device
TERM Pin Signal name
Display RDA 1 SD+
CA3-ADPCOM-01
RDB 2 SD-
SDA 3 RD+
CA3-ADPTRM-01 SDB 4 RD-
SG 6 SG
FG 5 TERM
• 1:n Connection
Signal name Shield External Device Shield External Device
TERM Pin Signal name Pin Signal name
Display RDA 1 SD+ 1 SD+
CA3-ADPCOM-01
RDB 2 SD- 2 SD-
SDA 3 RD+ 3 RD+
CA3-ADPTRM-01 SDB 4 RD- 4 RD-
SG 6 SG 6 SG
FG 5 TERM 5 TERM
• 1:n Connection
D-Sub 9 pin (socket) External Device Shield External Device
Terminal Shield
resistance Pin Signal name Pin Signal name Pin Signal name
100 Ω (1/2W)
1 RDA 1 SD+ 1 SD+
2 RDB 2 SD- 2 SD-
Display 3 SDA 3 RD+ 3 RD+
7 SDB 4 RD- 4 RD-
5 SG 6 SG 6 SG
4 ERA 5 TERM 5 TERM
8 CSA
9 ERB
6 CSB
Shell FG
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
Signal name Shield External Device Shield External Device
TERM Pin Signal name Pin Signal name
Display RDA 1 SD+ 1 SD+
CA4-ADPONL-01
RDB 2 SD- 2 SD-
SDA 3 RD+ 3 RD+
CA3-ADPTRM-01 SDB 4 RD- 4 RD-
SG 6 SG 6 SG
FG 5 TERM 5 TERM
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
D-Sub 9 pin (plug)
Pin Signal name Shield External Device
CA4-ADPONL-01 1 TERMRX Signal name
Pin
Display 2 RDA 1 SD+
7 RDB 2 SD-
3 SDA 3 RD+
8 SDB 4 RD-
5 SG 6 SG
9 TERMTX 5 TERM
Shell FG
• 1:n Connection
D-Sub 9 pin (plug)
Pin Signal name Shield External Device Shield External Device
CA4-ADPONL-01 1 TERMRX Signal name
Pin Pin Signal name
Display 2 RDA 1 SD+ 1 SD+
7 RDB 2 SD- 2 SD-
3 SDA 3 RD+ 3 RD+
8 SDB 4 RD- 4 RD-
5 SG 6 SG 6 SG
9 TERMTX 5 TERM 5 TERM
Shell FG
E. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Signal name Shield External Device
TERM Pin Signal name
Display RDA 3 RD+
CA3-ADPCOM-01
RDB 4 RD-
SDA 1 SD+
CA3-ADPTRM-01 SDB 2 SD-
SG 6 SG
FG 5 TERM
• 1:n Connection
Signal name Shield External Device Shield External Device
TERM Pin Signal name Pin Signal name
Display RDA 3 RD+ 3 RD+
CA3-ADPCOM-01
RDB 4 RD- 4 RD-
SDA 1 SD+ 1 SD+
CA3-ADPTRM-01 SDB 2 SD- 2 SD-
SG 6 SG 6 SG
FG 5 TERM 5 TERM
• 1:n Connection
Cable Diagram 8
Display
Cable Remarks
(Connection Port)
A.When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name D-Sub 15 pin (plug)
Shield
TERM Pin Signal name
Display RDA 13 SDP
CA3-ADPCOM-01
RDB 12 SDN
SDA 11 RDP
CA3-ADPTRM-01 SDB 10 RDN
SG 7 SG
FG 9 RT
14 RSP
15 CSN
• 1:n Connection
External Device External Device
Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield Shield
TERM Pin Signal name Pin Signal name
Display RDA 13 SDP 13 SDP
CA3-ADPCOM-01
RDB 12 SDN 12 SDN
SDA 11 RDP 11 RDP
CA3-ADPTRM-01 SDB 10 RDN 10 RDN
SG 7 SG 7 SG
FG 9 RT 9 RT
14 RSP 14 RSP
15 CSN 15 CSN
• 1:n Connection
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name D-Sub 15 pin (plug)
Shield
TERM Pin Signal name
Display RDA 13 SDP
CA4-ADPONL-01
RDB 12 SDN
SDA 11 RDP
CA3-ADPTRM-01 SDB 10 RDN
SG 7 SG
FG 9 RT
14 RSP
15 CSN
• 1:n Connection
External Device External Device
Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield Shield
TERM Pin Signal name Pin Signal name
Display RDA 13 SDP 13 SDP
CA4-ADPONL-01
RDB 12 SDN 12 SDN
SDA 11 RDP 11 RDP
CA3-ADPTRM-01 SDB 10 RDN 10 RDN
SG 7 SG 7 SG
FG 9 RT 9 RT
14 RSP 14 RSP
15 CSN 15 CSN
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
D-Sub 9 pin (plug)
External Device
Pin Signal name D-Sub 15 pin (plug)
Shield
CA4-ADPONL-01 1 TERMRX Pin Signal name
Display 2 RDA 13 SDP
7 RDB 12 SDN
3 SDA 11 RDP
8 SDB 10 RDN
5 SG 7 SG
9 TERMTX 9 RT
Shell FG 14 RSP
15 CSN
• 1:n Connection
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name D-Sub 15 pin (plug) D-Sub 15 pin (plug)
CA4-ADPONL-01 Shield Shield
1 TERMRX Pin Signal name Pin Signal name
Display 2 RDA 13 SDP 13 SDP
7 RDB 12 SDN 12 SDN
3 SDA 11 RDP 11 RDP
8 SDB 10 RDN 10 RDN
5 SG 7 SG 7 SG
9 TERMTX 9 RT 9 RT
Shell FG 14 RSP 14 RSP
15 CSN 15 CSN
Cable Diagram 9
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
TERM Pin Signal name
Display RDA 13 SDP
CA3-ADPCOM-01
RDB 12 SDN
SDA 11 RDP
CA3-ADPTRM-01 SDB RDN
10
SG 7 SG
FG 9 RT
14 RSP
15 CSN
• 1:n Connection
External Device External Device
Signal name Shield D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield
TERM Pin Signal name Pin Signal name
Display RDA 13 SDP 13 SDP
CA3-ADPCOM-01
RDB 12 SDN 12 SDN
SDA 11 RDP 11 RDP
CA3-ADPTRM-01 SDB RDN
10 10 RDN
SG 7 SG 7 SG
FG 9 RT 9 RT
14 RSP 14 RSP
15 CSN 15 CSN
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Terminal Shield
resistance Pin Signal name Pin Signal name
120 Ω (1/2W)
1 RDA 13 SDP
2 RDB 12 SDN
Display 3 SDA 11 RDP
7 SDB 10 RDN
5 SG 7 SG
4 ERA 9 RT
8 CSA 14 RSP
9 ERB 15 CSN
6 CSB
Shell FG
• 1:n Connection
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
TERM Pin Signal name
Display RDA 13 SDP
CA4-ADPONL-01
RDB 12 SDN
SDA 11 RDP
CA3-ADPTRM-01 SDB RDN
10
SG 7 SG
FG 9 RT
14 RSP
15 CSN
• 1:n Connection
External Device External Device
Signal name Shield D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Shield
TERM Pin Signal name Pin Signal name
Display RDA 13 SDP 13 SDP
CA4-ADPONL-01
RDB 12 SDN 12 SDN
SDA 11 RDP 11 RDP
CA3-ADPTRM-01 SDB RDN
10 10 RDN
SG 7 SG 7 SG
FG 9 RT 9 RT
14 RSP 14 RSP
15 CSN 15 CSN
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name Shield D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug)
CA4-ADPONL-01 1 TERMRX Pin Pin
Signal name Signal name
Display 2 RDA 13 SDP 13 SDP
7 RDB 12 SDN 12 SDN
3 SDA 11 RDP 11 RDP
8 SDB 10 RDN 10 RDN
5 SG 7 SG 7 SG
9 TERMTX 9 RT 9 RT
Shell FG 14 RSP 14 RSP
15 CSN 15 CSN
E. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield D-Sub 15 pin (plug)
TERM Pin Signal name
Display
CA3-ADPCOM-01 RDA 11 RDP
RDB 10 RDN
SDA 13 SDP
CA3-ADPTRM-01 SDB 12 SDN
SG 7 SG
FG 9 RT
14 RSP
15 CSN
• 1:n Connection
External Device External Device
Signal name Shield D-Sub 15 pin (plug) Shield D-Sub 15 pin (plug)
TERM Pin Signal name Pin Signal name
Display RDA 11 RDP 11 RDP
CA3-ADPCOM-01
RDB 10 RDN 10 RDN
SDA 13 SDP 13 SDP
CA3-ADPTRM-01 SDB 12 SDN 12 SDN
SG 7 SG 7 SG
FG 9 RT 9 RT
14 RSP 14 RSP
15 CSN 15 CSN
External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug)
Terminal Shield
resistance Pin Signal name Pin Signal name
120Ω (1/2W)
1 DATA+ 11 RDP
2 DATA- 10 RDN
Display 3 NC 13 SDP
7 NC 12 SDN
5 GND(SG) 7 SG
4 ERA 9 RT
8 CSA 14 RSP
9 ERB 15 CSN
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) D-Sub 15 pin (plug) D-Sub 15 pin (plug)
Terminal Shield Shield
resistance Pin Signal name Pin Signal name Pin Signal name
120Ω (1/2W)
1 DATA+ 11 RDP 11 RDP
2 DATA- 10 RDN 10 RDN
Display 3 NC 13 SDP 13 SDP
7 NC 12 SDN 12 SDN
5 GND(SG) 7 SG 7 SG
4 ERA 9 RT 9 RT
8 CSA 14 RSP 14 RSP
9 ERB 15 CSN 15 CSN
6 CSB
Shell FG
Cable Diagram 10
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name RJ-45 conncetor
Shield
TERM Pin Signal name
Display RDA 4 SDP
CA3-ADPCOM-01
RDB 5 SDN
SDA 7 RDP
CA3-ADPTRM-01 SDB 6 RDN
SG 1 SG
FG 8 TERM
• 1:n Connection
External Device External Device
Signal name RJ-45 conncetor RJ-45 conncetor
Shield Shield
TERM Pin Signal name Pin Signal name
Display RDA 4 SDP 4 SDP
CA3-ADPCOM-01
RDB 5 SDN 5 SDN
SDA 7 RDP 7 RDP
CA3-ADPTRM-01 SDB 6 RDN 6 RDN
SG 1 SG 1 SG
FG 8 TERM 8 TERM
External Device
D-Sub 9 pin (socket) RJ-45 conncetor
Terminal Shield
resistance Pin Signal name Pin Signal name
120 Ω (1/2W)
1 RDA 4 SDP
2 RDB 5 SDN
Display 3 SDA 7 RDP
7 SDB 6 RDN
5 SG 1 SG
4 ERA 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) RJ-45 conncetor RJ-45 conncetor
Terminal Shield Shield
resistance Pin Signal name Pin Signal name Pin Signal name
120 Ω (1/2W)
1 RDA 4 SDP 4 SDP
2 RDB 5 SDN 5 SDN
Display 3 SDA 7 RDP 7 RDP
7 SDB 6 RDN 6 RDN
5 SG 1 SG 1 SG
4 ERA 8 TERM 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name RJ-45 conncetor
Shield
TERM Pin Signal name
Display RDA 4 SDP
CA4-ADPONL-01
RDB 5 SDN
SDA 7 RDP
CA3-ADPTRM-01 SDB 6 RDN
SG 1 SG
FG 8 TERM
• 1:n Connection
D.When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
D-Sub 9 pin (plug) External Device
Pin Signal name RJ-45 conncetor
CA4-ADPONL-01 Shield
1 TERMRX Pin Signal name
Display 2 RDA 4 SDP
7 RDB 5 SDN
3 SDA 7 RDP
8 SDB 6 RDN
5 SG 1 SG
9 TERMTX 8 TERM
Shell FG
• 1:n Connection
D-Sub 9 pin (plug) External Device External Device
Pin Signal name RJ-45 conncetor RJ-45 conncetor
CA4-ADPONL-01 Shield Shield
1 TERMRX Pin Signal name Pin Signal name
Display 2 RDA 4 SDP 4 SDP
7 RDB 5 SDN 5 SDN
3 SDA 7 RDP 7 RDP
8 SDB 6 RDN 6 RDN
5 SG 1 SG 1 SG
9 TERMTX 8 TERM 8 TERM
Shell FG
Cable Diagram 11
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA 4 SDP
CA3-ADPCOM-01
RDB 5 SDN
SDA 7 RDP
CA3-ADPTRM-01 SDB 6 RDN
SG 1 SG
FG 8 TERM
• 1:n Connection
External Device External Device
Signal name Shield RJ-45 conncetor RJ-45 conncetor
Shield
TERM Pin Signal name Pin Signal name
Display RDA 4 SDP 4 SDP
CA3-ADPCOM-01
RDB 5 SDN 5 SDN
SDA 7 RDP 7 RDP
CA3-ADPTRM-01 SDB 6 RDN 6 RDN
SG 1 SG 1 SG
FG 8 TERM 8 TERM
External Device
D-Sub 9 pin (socket) RJ-45 conncetor
Terminal Shield
resistance Pin Signal name Pin Signal name
120 Ω (1/2W)
1 RDA 4 SDP
2 RDB 5 SDN
Display 3 SDA 7 RDP
7 SDB 6 RDN
5 SG 1 SG
4 ERA 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) RJ-45 conncetor RJ-45 conncetor
Terminal Shield Shield
resistance Pin Signal name Pin Signal name Pin Signal name
120 Ω (1/2W)
1 RDA 4 SDP 4 SDP
2 RDB 5 SDN 5 SDN
Display 3 SDA 7 RDP 7 RDP
7 SDB 6 RDN 6 RDN
5 SG 1 SG 1 SG
4 ERA 8 TERM 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA 4 SDP
CA4-ADPONL-01
RDB 5 SDN
SDA 7 RDP
CA3-ADPTRM-01 SDB 6 RDN
SG 1 SG
FG 8 TERM
• 1:n Connection
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA 4 SDP 4 SDP
CA4-ADPONL-01
RDB 5 SDN 5 SDN
SDA 7 RDP 7 RDP
CA3-ADPTRM-01 SDB 6 RDN 6 RDN
SG 1 SG 1 SG
FG 8 TERM 8 TERM
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
• 1:n Connection
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
CA4-ADPONL-01 1 TERMRX Pin Signal name Pin Signal name
Display 2 RDA 4 SDP 4 SDP
7 RDB 5 SDN 5 SDN
3 SDA 7 RDP 7 RDP
8 SDB 6 RDN 6 RDN
5 SG 1 SG 1 SG
9 TERMTX 8 TERM 8 TERM
Shell FG
E. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA 7 RDP
CA3-ADPCOM-01
RDB 6 RDN
SDA 4 SDP
CA3-ADPTRM-01 SDB 5 SDN
SG 1 SG
FG 8 TERM
• 1:n Connection
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA 7 RDP 7 RDP
CA3-ADPCOM-01
RDB 6 RDN 6 RDN
SDA 4 SDP 4 SDP
CA3-ADPTRM-01 SDB 5 SDN 5 SDN
SG 1 SG 1 SG
FG 8 TERM 8 TERM
External Device
D-Sub 9 pin (socket) RJ-45 conncetor
Terminal Shield
resistance Pin Signal name Pin Signal name
120Ω (1/2W)
1 DATA+ 7 RDP
2 DATA- 6 RDN
Display 3 NC 4 SDP
7 NC 5 SDN
5 GND(SG) 1 SG
4 ERA 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
• 1:n Connection
External Device External Device
D-Sub 9 pin (socket) RJ-45 conncetor RJ-45 conncetor
Terminal Shield Shield
resistance Pin Signal name Pin Signal name Pin Signal name
120Ω (1/2W)
1 DATA+ 7 RDP 7 RDP
2 DATA- 6 RDN 6 RDN
Display 3 NC 4 SDP 4 SDP
7 NC 5 SDN 5 SDN
5 GND(SG) 1 SG 1 SG
4 ERA 8 TERM 8 TERM
8 CSA
9 ERB
6 CSB
Shell FG
Cable Diagram 12
Display
Cable Remarks
(Connection Port)
Cable Diagram 13
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Display
Terminal block
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display
RDA 3 TX
CA3-ADPCOM-01
RDB 5 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 6 RXN
SG 1 SG
FG
• 1:n Connection
Display
Terminal block
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA 3 TX 3 TX
CA3-ADPCOM-01
RDB 5 TXN 5 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 6 RXN 6 RXN
SG 1 SG 1 SG
FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
• 1:n Connection
Display External Device External Device
D-Sub 9 pin (socket) RJ-45 conncetor RJ-45 conncetor
Terminal Shield Shield
resistance Pin Signal name Pin Signal name Pin Signal name
100 Ω (1/2W)
1 RDA 3 TX 3 TX
2 RDB 5 TXN 5 TXN
Display 3 SDA 7 RX 7 RX
7 SDB 6 RXN 6 RXN
5 SG 1 SG 1 SG
4 ERA
8 CSA
9 ERB
6 CSB
Shell FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
Display
Terminal block
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA 3 TX
CA4-ADPONL-01
RDB 5 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 6 RXN
SG 1 SG
FG
• 1:n Connection
Display
Terminal block
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA
CA4-ADPONL-01 3 TX 3 TX
RDB 5 TXN 5 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 6 RXN 6 RXN
SG 1 SG 1 SG
FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
Display
D-Sub 9 pin (plug)
Shield External Device
Pin Signal name RJ-45 conncetor
CA4-ADPONL-01 1 TERMRX Pin Signal name
Display 2 RDA 3 TX
7 RDB 5 TXN
3 SDA 7 RX
8 SDB 6 RXN
5 SG 1 SG
9 TERMTX
Shell FG
• 1:n Connection
Display
D-Sub 9 pin (plug)
Shield External Device External Device
Pin Signal name RJ-45 conncetor RJ-45 conncetor
Shield
CA4-ADPONL-01 1 TERMRX Pin Signal name Pin Signal name
Display 2 RDA 3 TX 3 TX
7 RDB 5 TXN 5 TXN
3 SDA 7 RX 7 RX
8 SDB 6 RXN 6 RXN
5 SG 1 SG 1 SG
9 TERMTX
Shell FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
Cable Diagram 14
Display
Cable Remarks
(Connection Port)
A. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Display
Terminal block
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA
CA3-ADPCOM-01 3 TX
RDB 5 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 6 RXN
SG 1 SG
FG
• 1:n Connection
Display
Terminal block
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA
CA3-ADPCOM-01 3 TX 3 TX
RDB 5 TXN 5 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 6 RXN 6 RXN
SG 1 SG 1 SG
FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
• 1:n Connection
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
C. When using the online adapter (CA4-ADPONL-01), the terminal block conversion adapter (CA3-ADPTRM-
01) by Pro-face and your own cable
• 1:1 Connection
Display
Terminal block
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA
CA4-ADPONL-01 3 TX
RDB 5 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 6 RXN
SG 1 SG
FG
• 1:n Connection
Display
Terminal block
External Device External Device
Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA 3 TX 3 TX
CA4-ADPONL-01
RDB 5 TXN 5 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 6 RXN 6 RXN
SG 1 SG 1 SG
FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
D. When using the online adapter (CA4-ADPONL-01) by Pro-face and your own cable
• 1:1 Connection
Display
D-Sub 9 pin (plug)
External Device
Pin Signal name Shield RJ-45 conncetor
CA4-ADPONL-01 1 TERMRX Pin Signal name
Display 2 RDA 3 TX
7 RDB 5 TXN
3 SDA 7 RX
8 SDB 6 RXN
5 SG 1 SG
9 TERMTX
Shell FG
• 1:n Connection
Display
D-Sub 9 pin (plug)
External Device External Device
Pin Signal name Shield RJ-45 conncetor Shield RJ-45 conncetor
CA4-ADPONL-01 1 TERMRX Signal name Signal name
Pin Pin
Display 2 RDA 3 TX 3 TX
7 RDB 5 TXN 5 TXN
3 SDA 7 RX 7 RX
8 SDB 6 RXN 6 RXN
5 SG 1 SG 1 SG
9 TERMTX
Shell FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
E. When using the COM port conversion adapter (CA3-ADPCOM-01), the terminal block conversion adapter
(CA3-ADPTRM-01) by Pro-face and your own cable
• 1:1 Connection
Display
Terminal block
External Device
Signal name Shield RJ-45 conncetor
TERM Pin Signal name
Display RDA 3 TX
CA3-ADPCOM-01
RDB 5 TXN
SDA 7 RX
CA3-ADPTRM-01 SDB 6 RXN
SG 1 SG
FG
• 1:n Connection
Display
Terminal block
External Device External Device
Signal name Shield Shield
RJ-45 conncetor RJ-45 conncetor
TERM Pin Signal name Pin Signal name
Display RDA TX TX
CA3-ADPCOM-01 3 3
RDB 5 TXN 5 TXN
SDA 7 RX 7 RX
CA3-ADPTRM-01 SDB 6 RXN
6 RXN
SG 1 SG 1 SG
FG
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
• 1:n Connection
• Please turn on the DIP Switch 1 to enable build-in resistance(100Ω) on the remotest External
Device side.
6 Supported Device
Double Word
Device Bit Address Word Address 32 bits Remarks
Address
WX0000- *1 *2
External Input X00000-X05A95 DX0000-DX05A6
WX05A7
WY0000- *2
External Output Y00000-Y05A95 DY0000-DY05A6
WY05A7
*1 *3
Remote Input Relay X10000-X49995 WX1000-WX4997 DX1000-DX4996
*3
Remote Output Relay Y10000-Y49995 WY1000-WY4997 DY1000-DY4996
WDT0000-
Watchdog Timer - -
WDT1023
TMR0000-
Retentive Timer - -
TMR1023
Up Counter CU0000-CU2047 - -
RCU0000-
Ring Counter - -
RCU2047
TM0000 -
Extended Timer - -
TM2047
Timer Counter
- TC0000-TC2047 -
(Elapsed Value)
Extended Timer
- TV0000 - TV2047 -
(Elapsed Value)
Double Word
Device Bit Address Word Address 32 bits Remarks
Address
WR0000-
Word Internal Output - DR0000-DRC3FE
WRC3FF
WN0000-
Network Link Area - DN0000-DN7FFE
WN7FFF
*1 Write disable
*2 Specify as shown below.
(Example) External input unit No.1, Slot No.2, Internal Module Bit No.34
X01234
(Example) External input unit No.1, Slot No.2, Internal Module Word No.34
WX0123
(Example) Remote External Input Remote Master No.1, Remote Slave No.2, Slot No.3, Internal Module Word
No.4
WX1234
• Available type and range of device vary depending on CPU. Be sure to check them in each CPU
manual before using.
Device Address
CPU Link Unit No.
CPU Link Loop No.
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EXReference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
Double Word
Device Bit Address Word Address 32 bit Remarks
Address
Y0100-Y0109 WY40
DY105-DY106
Y1016-Y1031 WY105-WY107
DY205-DY206
External Output Y2016-Y2031 WY205-WY207
DY305-DY306
Y3016-Y3031 WY305-WY307
DY405-DY406
Y4016-Y4031 WY405-WY407
Timer Counter
- TC000-TC255 -
(Elapsed Value)
WR0000- *4
Word Internal Output - DR0000-DRC3FE
WRC3FF
*1 Write disable
*2 Each timer or counter needs to be defined on the ladder program.
*3 Both the Up-down counter Up input and Down input are defined by CT, however, the device names of the
External Device are CTU, CTDrespectively.
To access CTU, define the corresponding address as CTU on the ladder program of the External Device.
Similarly, to access CTD, define the corresponding address as CTD on the ladder program of the External
Device.
*4 In case of EH-WD10DR, the address range is "WR0000-WR3FFF", "DR0000-DR3FFE".
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EXReference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
Double Word
Device Bit Address Word Address 32 bits Remarks
Address
WX0000- *1 *2
External Input X00000-X05A95 DX0000-DX05A6
WX05A7
WY0000- *2
External Output Y00000-Y05A95 DY0000-DY05A6
WY05A7
WX1000- *1 *3
Remote Input Relay X10000-X45A95 DX1000-DX45A6
WX45A7
WY1000- *3
Remote Output Relay Y10000-Y45A95 DY1000-DY45A6
WY45A7
WM0000- DM0000-
Data Area M00000-M7FFFF
WM7FFF DM7FFE
TDN0000-
Off Delay Timer - -
TDN2559
WDT0000-
Watchdog Timer - -
WDT2559
TMR0000-
Retentive Timer - -
TMR2559
Up Counter CU000-CU511 - -
Double Word
Device Bit Address Word Address 32 bits Remarks
Address
Timer Counter
- TC0000-TC2559 -
(Elapsed Value)
WR00000- WR0000-
Word Internal Output DR0000-DREFFE
WREFFFF WREFFF
*1 Write disable
*2 Specify as shown below.
(Example) External input unit No.1, Slot No.2, Internal Module Bit No.34
X01234
(Example) External input unit No.1, Slot No.2, Internal Module Word No.3
WX0123
(Example) Remote External Input Remote Master No.1, Remote Slave No.2, Slot No.3, Internal Module Word
No.4
WX1234
Device Address
CPU Link Unit No.
CPU Link Loop No.
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EXReference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
Use device code and address code when you select "Device Type & Address" for the address type in data displays.
Device Code
Device Device Name Address Code
(HEX)
X Word Address
80
External Input WX Word Address
DX 20 Word Address
Y Word Address
81
External Output WY Word Address
DY 21 Word Address
M Word Address
82
Data Area WM Word Address
DM 22 Word Address
L Word Address
83
CPU Link WL Word Address
DL 23 Word Address
Timer Counter
TC 60 Word Address
(Elapsed Value)
Extended Timer
TV 61 Word Address
(Elapsed Value)
WR 00 Word Address
Word Internal Output
DR 24 Word Address
WN 01 Word Address
Network Link Area
DN 25 Word Address
Device Code
Device Device Name Address Code
(HEX)
X Word Address
80
External Input WX Word Address
DX 20 Word Address
Y Word Address
81
External Output WY Word Address
DY 21 Word Address
M Word Address
82
Data Area WM Word Address
DM 22 Word Address
Device Code
Device Device Name Address Code
(HEX)
X Word Address
80
External Input WX Word Address
DX 20 Word Address
Y Word Address
81
External Output WY Word Address
DY 21 Word Address
EX Word Address
84
Extension External Input WEX Word Address
EY Word Address
85
Extension External Output WEY Word Address
M Word Address
82
Data Area WM Word Address
DM 22 Word Address
L Word Address
83
CPU Link WL Word Address
DL 23 Word Address
WR 00 Word Address
Word Internal Output
DR 24 Word Address
WN 01 Word Address
Data Area
DN 25 Word Address
Timer Counter
TC 60 Word Address
(Elapsed Value)
8 Error Messages
Error messages are displayed on the screen of the Display as follows: "No. :Device Name:Error Message(Error
Occurrence Area)". Each description is shown below.
Item Description
No. Error No.
Name of the External Device where error occurs. Device name is a title of the External
Device Name
Device set with GP-Pro EX.((Initial value[PLC1])
Error Message Displays messages related to the error which occurs.
Displays IP address or device address of the External Device where error occurs, or error
codes received from the External Device.
• Refer to your External Device manual for details on received error codes.
• Refer to "When an error is displayed (Error Code List)" in "Maintenance/Troubleshooting Manual"
for details on the error messages common to the driver.
• Please refer to the manual of the External Device for more detail of received error codes.