VS6M Solenoid Operated Directional Control Valve Form 1019381 Rev. 09 14
VS6M Solenoid Operated Directional Control Valve Form 1019381 Rev. 09 14
CONTINENTAL HYDRAULICS
VS6M
SOLENOID OPERATED DIRECTIONAL VALVES
NFPA D03
OPERATIONS MOUNTING SURFACE
ISO 4401-03-02-0-03
The valve can be supplied for valve functions requiring 2 positions or 3
positions, as well as 3 way or 4 way flow functions.
Single Solenoid 3.3 lbs 1.5 kg
DIN 43650, AMP junior, DEUTSCH DT04-2P coil connections. WEIGHT
Salt spray resistance up to 600h (test according to UNI EN ISO 9227 Dual Solenoid 4.4 lbs 2.0 kg
and UNI EN ISO 10289 tests and standards).
FLUID VISCOSITY
2 WWW.CONTINENTALHYDRAULICS.COM - [email protected]
IDENTIFICATION CODE
D12 12V DC
2
Dual Solenoid D24 24V DC
2 Position
Detented (No Spring)
3
Dual Solenoid
3 Position
Spring Centered
SPOOLS
P→B or P→A
A All ports blocked
T blocked
1, 2, 3, 5
P blocked, P blocked,
F1 3, 5
A and B restricted to T A or B restricted to T
P→T,
L All ports open, restricted
A and B blocked
[email protected] - WWW.CONTINENTALHYDRAULICS.COM 3
PRESSURE DROPS ∆P-Q
(OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70°F - 50°C)
3A, F1 2 2 3 3
B 1 1 3 3 2
F 3 3 1 1
L 4 4 4 4 3
PERFORMANCE CURVE
DC VOLTAGE
CURVE SPOOL
1 A, 2A
2 F1
3 L, B
4 F
5 1A
6 1B
NOTES:
1. The values indicated in the graphs are relevant to the standard
solenoid valve, with D24 coils.
2. Valve performance was tested in a four way circuit (full loop).
Performances may be reduced from that shown when used in a
three-way circuit (half circuit), i.e. A or B port plugged.
3. The values have been obtained according to ISO 6403 norm with
solenoids at rated temperature and supplied with voltage equal to
90% of the nominal voltage. The value have been obtained with
filtration according to ISO 4406:1999 class 18/16/13.
4 WWW.CONTINENTALHYDRAULICS.COM - [email protected]
OVERALL AND MOUNTING DIMENSIONS - DIN STYLE VERSION
VS6M-2*, 3* Dimensions in mm [IN]
Mounting surface
Manual Override with sealing
Integrated in the Coil Removal rings:4 pcs.
Tube Space AS568-012 90
Shore A
VS6M-1*, 5*
[email protected] - WWW.CONTINENTALHYDRAULICS.COM 5
COIL FEATURES
RESISTANCE CURRENT POWER CONSUMPTION
VOLTAGE
CODE AT 68°F CONSUMPTION (±5%)
[VOLT]
[Ω] (±1%) [A] (±5%) [W]
VS6M - SOLENOID OPERATED DIRECTIONAL VALVES
The coils are fastened to the tube by a threaded nut and can be rotated 360°.
COIL CONNECTION
K1 - DIN 43650
This solenoid has three terminal posts. Use bi-polar connectors that meet ISO 4400 / DIN 43650
(EN 175301-803). Protection against atmospheric agent: IP 65*
K2 - AMP JUNIOR
Plug for this type of connector. Protection against atmospheric agent: IP 67*
*NOTE: The protection degree is guaranteed only with the connector correctly connected and installed.
SEAL KIT
Buna Seal Kit 1019393
BOLT KIT
BD03-125 1008406
NOTES:
1. Bolt kit consists of: qty. 4 10-24 NC screws / qty. 4 #10 Lock washer
2. The recommended torque value for fasteners is: 4 lb.ft (5.4 Nm)
6 WWW.CONTINENTALHYDRAULICS.COM - [email protected]
VS6M - SOLENOID OPERATED DIRECTIONAL VALVES
[email protected] - WWW.CONTINENTALHYDRAULICS.COM 7
VS6M - SOLENOID OPERATED DIRECTIONAL VALVES
[email protected]
5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM
FORM NO. 1019381. REV. 09/2014. © 2014 CONTINENTAL HYDRAULICS. ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT NOTICE.