AQL Sampling Plan and Sampling Table of Aventura Component Pvt. LTD

The document outlines 3 different inspection levels (I, II, III) and their corresponding sampling plans, sample sizes, and acceptance quality limits (AQL) for different lot sizes of components. Level II is generally used for second category components, while Level I and III are used for first and third category components respectively, where Level I has smaller sample sizes and tighter acceptance limits compared to Level III. Tables are provided detailing the code letter, sample size, reject numbers at each AQL level for each lot size range for each inspection level.

Uploaded by

Ranjit Singh
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
276 views

AQL Sampling Plan and Sampling Table of Aventura Component Pvt. LTD

The document outlines 3 different inspection levels (I, II, III) and their corresponding sampling plans, sample sizes, and acceptance quality limits (AQL) for different lot sizes of components. Level II is generally used for second category components, while Level I and III are used for first and third category components respectively, where Level I has smaller sample sizes and tighter acceptance limits compared to Level III. Tables are provided detailing the code letter, sample size, reject numbers at each AQL level for each lot size range for each inspection level.

Uploaded by

Ranjit Singh
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

AQL Sampling plan And Sampling Table of Aventura Component pvt. Ltd.

DOC. NO. AQL-01 Date-30/09/2010


Three Inspection level:I,II,III are given in table -1 for general use.Normally, Inspector level II is used. However inspection level
-I may be used when less discrimination is needed, or level -III may be used for greater discrimination
Sampling size code letters General Inspection level
Lot Size I II III
2 to 8 A A B
9 to 15 A B C
16 to25 B C D
26 to 50 C D F
51 to 90 C E F
91 to 150 D F G
151 to 280 E G H
281 to 500 F H J
501 to 1200 G J K
1201 to 3200 H K L
3201 to 10000 J L M
10001 to 35000 K M N
35001 to 150000 L N P
150001 to 500000 M P Q
500001 over N Q R

Prepared By Approved By
General level -II for - Sampling plan,Sample size,Reject levels And AQL- use for Second Categary component

Lot Size Cde letter sample Size 0.65 1 1.5 2.5 4 6.5 10 15

2 to 8 A 2 1 ^ v

9 to 15 B 3 1 ^ v 2

16 to25 C 5 1 ^ v 2 3

26 to 50 D 8 1 ^ v 2 3 4

51 to 90 E 13 1 ^ v 2 3 4 6

91 to 150 F 20 1 ^ v 2 3 4 6 8

151 to 280 G 32 ^ v 2 3 4 6 8 11

281 to 500 H 50 v 2 3 4 6 8 11 15

501 to 1200 J 80 2 3 4 6 8 11 15 22

1201 to 3200 K 125 3 4 6 8 11 15 22

3201 to 10000 L 200 4 6 8 11 15 22

10001 to 35000 M 315 6 8 11 15 22

35001 to 150000 N 500 8 11 15 22

150001 to 500000 P 800 11 15 22


500001 over Q 1250 15 22
General level -I for - Sampling plan,Sample size,Reject levels And AQL- use for First Categary component

Lot Size Cde letter sample Size 0.65 1 1.5 2.5 4 6.5 10 15

2 to 8 A 2 1 ^ v

9 to 15 B 3 1 ^ v 2

16 to25 C 5 1 ^ v 2 3

26 to 50 D 8 1 ^ v 2 3 4

51 to 90 E 13 1 ^ v 2 3 4 5

91 to 150 F 20 1 ^ v 2 3 4 5 6

151 to 280 G 32 ^ v 2 3 4 5 6 8

281 to 500 H 50 v 2 3 4 5 6 8 10

501 to 1200 J 80 2 3 4 5 6 8 10 13

1201 to 3200 K 125 3 4 5 6 8 10 13 ^

3201 to 10000 L 200 4 5 6 8 10 13 ^

10001 to 35000 M 315 5 6 8 10 13 ^

35001 to 150000 N 500 6 8 10 13 ^

150001 to 500000 P 800 8 10 13 ^

500001 over Q 1250 10 13 ^


General level -III for - Sampling plan,Sample size,Reject levels And AQL- use for Third Categary component

Lot Size Cde letter sample Size 0.65 1 1.5 2.5 4 6.5 10 15

2 to 8 A 2

9 to 15 B 3 1 v

16 to25 C 5 1 v 2

26 to 50 D 8 1 v 2 3

51 to 90 E 13 1 v 2 3 4

91 to 150 F 20 1 v 2 3 4 6

151 to 280 G 32 1 v 2 3 4 6 9

281 to 500 H 50 v 2 3 4 6 9 13

501 to 1200 J 80 v 2 3 4 6 9 13 19

1201 to 3200 K 125 2 3 4 6 9 13 19 ^

3201 to 10000 L 200 3 4 6 9 13 19 ^


10001 to 35000 M 315 4 6 9 13 19 ^

35001 to 150000 N 500 6 9 13 19 ^

150001 to 500000 P 800 9 13 19 ^

500001 over Q 1250 13 19 ^