Complex Engineering Problem
Complex Engineering Problem
Suppose as a practicing structural engineer, you are asked to perform the seismic analysis and design
of a 8-story commercial plaza building located in Islamabad.
5 spans @ 8m each
3 spans @ 8m each
Y
X
Plan view of the case study building
Now you are asked to perform the seismic analysis and design of this building according to ASCE 7-
16. The building is expected to experience the following loadings cases during its intended life (i.e. the
following design loads should be considered).
Question 4: Using the Equivalent Lateral Force Procedure (ASCE 7-16), determine the
equivalent earthquake forces for each story of this case study building. Assume missing data,
if any.
Question 5: Draw the “story shear force diagram” and “story bending moment diagram” of this
case study building due to seismic loads (equivalent earthquake forces).
Question 6: Perform the RC design of beams and columns for one (middle) frame of the
building in X direction. The selected frame is shown below.
5 spans @ 8m each
3 spans @ 8m each
Y
X
Notes:
1) You have to perform the static structural analysis of this frame under the applied three loading
cases. You will need a structural analysis software for this purpose.
Use the following load combination for the purpose of structural design.
Load Combination: 1.2D+L+EQ
a) D = Dead Load = Part of self-weight of the building taken by this middle frame (use
tributary areas)
b) L = Live Load = Part of live load on the building taken by this middle frame (use
tributary areas)
c) EQ = Seismic Loads = 1/4 of the total equivalent earthquake forces determined from
the ELF procedure (because the total seismic loading will be resisted by 4 frames in X
direction).
2) Draw the shear force diagram and story bending moment diagrams of this selected frame for
the given load combination (i.e. due to a combined loading of 1.2Dead, Live and Seismic
Loads). Seismic loads will be 1/4 of the total equivalent earthquake forces determined from the
ELF procedure. You will need a structural analysis software for this purpose.
3) Use this SFD and BMD of selected frame to perform the final design of RC beams and
columns. Determine the reinforcement in all members. Are the initial cross-sectional
dimensions adequate for these loadings?
Determine the longitudinal and shear reinforcement in all beams and columns. If the cross-
sections of beams and columns need revision, determine the revised sections.
INSTRUCTOR (S)