Minimum Requirements

The document outlines minimum requirements for rooms housing switchgear, control, and battery systems. Key requirements include: 1) Locations must be above water storage and at the same level as control or switchgear rooms. 2) Sizes range from 3500-18000 square feet with a 4200mm headroom clearance. 3) Doors and windows must be fire-rated and include signage, closers, and stripping. Cable entries and slots are also specified. 4) Finishes include tile, paint, and brick walls. Lighting, switches, ventilation, and fire protection systems are defined.

Uploaded by

Teo Yan Tee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
997 views12 pages

Minimum Requirements

The document outlines minimum requirements for rooms housing switchgear, control, and battery systems. Key requirements include: 1) Locations must be above water storage and at the same level as control or switchgear rooms. 2) Sizes range from 3500-18000 square feet with a 4200mm headroom clearance. 3) Doors and windows must be fire-rated and include signage, closers, and stripping. Cable entries and slots are also specified. 4) Finishes include tile, paint, and brick walls. Lighting, switches, ventilation, and fire protection systems are defined.

Uploaded by

Teo Yan Tee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

MINIMUM REQUIREMENTS

ROOM SWITCHGEAR CONTROL BATTERY

Not above Transformer, LT CB Not above Transformer, LT CB Not above Transformer, LT CB


and NER and NER and NER
Location Not below water Not below water Not below water
storage/water related activities storage/water related activities storage/water related activities
Same level as Control room Same level as Switchgear room Same level as Switchgear room

Size 18000 x 12000 6000 x 18000 3500 x 6000


Headroom
clearance from 4200 4200 4200
beam soffit

3000 x 3500 (h) Solid G.I


auto/manual roller shutter
door linked with firefighting 2000 x 2700 (h) double leaf 2
1000 x 2100 (h) 2 hour fire-
system with closing time less hour fire rated door with
Main Door rated door with Bomba tag and
than 30 seconds c/w black & Bomba tag c/w door closer and
rubber skirting
yellow stripe (in front entrance) rubber skirting
Ramp at entrance (1000mm
after RS)

1000 x 2100 (h) 1 hour fire- 1000 x 2100 (h) 1 hour fire- 1000 x 2100 (h) 1 hour fire-
Side Door/
rated mild steel doorc/w closer rated mild steel doorc/w closer rated mild steel doorc/w closer
Escape Door
and rubber skirting and rubber skirting and rubber skirting
Signage All doors shall have Latch & Hasp

Aluminium lourves c/w anti-


Windows Top Hung Glass Top Hung Glass
vermin netting (both sides)
Slot opening (1500 offset from
Slot opening (1000 offset from
wall/column)
wall/column)
500 cantilever slab both side
without cross beams
without cross beams
Cable Entry/ 33kV - 600 x 13000 200 x 500
33kV - 1200 x 11000
Cable Slot/ Trench 11kV - 600 x 13000 (1000 offset from wall)
11kV - 1200 x 16000
RTCC/RTU
LVAC slot
2 x 600 x 2000
500 x 1000
(1000mm offset from wall)
(1000 offset from wall)
Slot/Trench Cover 6mm thick reinf
ROOM SWITCHGEAR CONTROL BATTERY
Plinth Size N/A N/A N/A
2 2 2
Design Load 10kN/m 10kN/m 10kN/m

Floor Hardener + Epoxy Paint Floor Hardener + Epoxy Paint Anti-acid homogeneous floor
Floor Finish
Nippon EA-4 Evergreen 1461 Nippon EA-4 Evergreen 1461 tiles

2100mm high allround Rim 2100mm high allround Rim 2100mm high allround anti-
Wall Finish Grey (10397) Gloss Paint, ICI or Grey (10397) Gloss Paint, ICI or acid homogeneous wall tiles &
(Internal) equivalent & above 2100mm equivalent & above 2100mm white emulsion paint above
white emulsion paint white emulsion paint 2100mm
Rim G
Wall Finish
TNB Corporate Stripe above 2800mm from FFL - 1
(External)
Selection of colours should be harmonized with t

Brickwalls 225mm thick Redbrick

Ceiling
John Lysaght "Klip Lok Hi Ten" 0.48mm thick metal deck c/w galvanised chicken netting, double sided aluminium
Roofing Roof truss - lightweight steel
Roof slab - Reinforced concrete slab with approved water proofing membrane with five (5) years warranty certi
Gutter Reinforced concrete gutter with a
2 x 23W ceiling mounted LED 2 x 23W ceiling mounted LED
2 x 23W ceiling mounted LED
T8 bare channel c/w angle T8 bare channel c/w angle
T8 bare channel anti-corrosive
reflector (min. 1000 away from reflector (min. 1000 away from
type (min. 1000 away from slot)
slot) slot)

Electrical Fittings 2400 (h) 2 x 23W wall 2400 (h) 2 x 23W wall
Switches for lamp and exhaust
(Lighting) mounted LED T8 bare channel mounted LED T8 bare channel
fan located outside of the room
c/w angle reflector c/w angle reflector

Lux of lighting (min. 400 lux)


13W emergency light
"KELUAR" sign at every exit door

Electrical Fittings
1500 (h) 13 Amp power point - tagging to follow schematic; test for each electrical socket using ELCB & So
(Switches)
ROOM SWITCHGEAR CONTROL BATTERY

(2.5HP/3.0HP/5.0HP) wall mounted split unit type


400mmØ (16") Exhaust fan
airconditioner @ approx. 3000 (h) c/w aircond tray and remote
(switch placed outside of room)
control for each room
Covered with suitable netting /
(Fully aircond 24 °C DB 50% relative humidity
adjustable shutters
Ventilation Aircond 24 hrs, alternate operation of 12hrs)
Air-cond signage number
Indoor unit - signage number Aluminium lourves c/w anti-
Air-Cond DB - marked with the yellow line at the floor c/w vermin netting (both sides)
Laminated Schematic Diagram DB / Sub-DB
Min. 2 kg port. CO2 Min. 2 kg port. CO2 Min. 2 kg port. CO2
extinguishers c/w labeling / extinguishers c/w labeling / extinguishers c/w labeling /
tag, BOMBA certificates and tag, BOMBA certificates and tag, BOMBA certificates and
demarcation line demarcation line demarcation line
- wall (50mm red stripe on - wall (50mm red stripe on - wall (50mm red stripe on
Fire Protection white background) white background) white background)
System - floor (100mm yellow stripe - floor (100mm yellow stripe - floor (100mm yellow stripe
(Approved Clean with 200mm spacing diagonals with 200mm spacing diagonals with 200mm spacing diagonals
Gas Agent) at 45°) at 45°) at 45°)
Discharge nozzles (1000mm away from slot opening) N/A
Smoke & Heat detector Smoke detector
Main Fire Alarm Panel (MFAP) (outsid

Location of cylind
Approved Clean
Halocarbons or
Gas Agent

Earthing System 6 x 50mm copper tape - ring 6 x 50mm copper tape - ring 6 x 50mm copper tape - ring
to Achieve Earth system system system
Resistance < 3 3 nos earth point at 11kV slot 2 nos earth point at 11kV slot 1 no earth bar at cable opening
ohm 4 nos earth point at 33kV slot 2 nos earth point at 33kV slot Cadweld/Brazed joints

Lightning 4 nos lightning terminal at highest point run throu


Protection Test point at 4 corners at 2.1m height sha
Loading Bay 3000 (w) x 4000 (l), Floor finish – power float c/w 900mm high 75mmØ stainless stee
Ceramic lab type c/w flexible
goose-neck tap
- Mirror 18” x 18” c/w
"UTAMAKAN KESELAMATAN" sign – green colour (lettering),
aluminium frame
Others white (background)
- Stop cock - nearby wash hand
CPR signage - DRCAB
basin
- Direct water supply & Water
tank (above)
Access Road 8000mm (wide) (Premix/Crusher Run*) Catered fo
ROOM SWITCHGEAR CONTROL BATTERY

(Premix/Reinforced Concrete) road


Internal Road In front of loading bay - 6000mm (w), Others - 3000mm (w)
To conduct coring test min. 2 location (in front of loading bay and transformer bay)
Main Gate 8000mm (w) x 2400mm (h) Hot dipped galvanised iron with anticlimb antic
2100mm (h) hot dipped galvanised iron, anticlim
Perimeter Fencing
150mm thk 38 – 50mmØ stone chip
Perimeter
Culverts & sump (stan
drainage system
Sewerage System (Centralize/Individual)** Culverts

Water Supply (Domestic con


Compound
Surfacing
Compound
8 nos 4000mm (h
Lighting
- Sub DB (e
(Standalone)
Compound
Earthing System
Heavy Duty Reinforced Concrete earthing cham
to Achieve Earth
- Link Earth Resistance < 3 ohms, shall be tested and certified by service engineer w
Resistance < 3
ohm

TNB Care
Compound
Danger sign,
Signage
No entry sign
Safety E
M REQUIREMENTS FOR PPU 33/11KV BUILDING CONSTRUCTION

TRANSFORMER
CABLE CELLAR LT
2 X 30MVA

Above ground level


OR Above ground level Above ground level
Same level as carpark

18000 x 18000 8000 x 9500 3000 x 5000

2200 8000 4800

Standalone 5000 X 2500 (h) Standalone 2000 X 2500 (h)


removable fencing removable fencing
galvanised frame with hot galvanised frame with hot
dipped galvanised iron with dipped galvanised iron with
anticlimb anticut mesh as per anticlimb anticut mesh as per
specs (12.5mm x 75mm x 4mm specs (12.5mm x 75mm x 4mm
1800 x 2100 (h) double leaf
diameter) c/w latch & hasp diameter) c/w latch & hasp
solid mild steel doorc/w closer
and rubber skirting
Attached 5000 x 6000 (h) Solid Attached 2000 x 3000 (h) Solid
G.I auto/manual roller shutter G.I auto/manual roller shutter
door linked with firefighting door linked with firefighting
system with closing time less system with closing time less
than 30 seconds than 30 seconds

1800 x 2100 (h) double leaf 900 x 2100 (h) 1 hour fire- 900 x 2100 (h) 1 hour fire-
solid mild steel doorc/w closer rated mild steel door(next to rated mild steel door(next to
and rubber skirting roller shutter) roller shutter)
have Latch & Hasp c/w lock protector, Danger signage, No Entry signage and Room signage

Ventilation block c/w anti-


vermin netting (both sides)
24 nos HDPE PN10 encased in
concrete c/w endcaps with
1000mm flat cable landing
900 x 600 (Depth clearance 450 x 600 (Depth clearance
before 30° smooth sloping
from ground beam) from ground beam)
ramp
2 x 900 x 2000mm slot c/w 2 x 450 x 1000mm slot c/w
chequered plate chequered plate
33kV pipes - 150mmØ
11kV pipes - 200mmØ

6mm thick reinforced chequered plates with lifting holes and handles
TRANSFORMER
CABLE CELLAR LT
2 X 30MVA
N/A 4200 x 2000 x 150 1000 x 1800 x 150
2
10kN/m 60 ton 5 ton
Attached Floor Hardener Attached Floor Hardener
Floor Hardener + Epoxy Paint Standalone 150mm layer Standalone 150mm layer
Nippon EA-4 Evergreen 1461 thickness 25mm - 38mm Ø thickness 25mm - 38mm Ø
granite chipping granite chipping

ICI Rim Grey (10397) or ICI Rim Grey (10397) or


White emulsion paint
equivalent equivalent

Rim Grey (10397) ICI Weathershield or equivalent


00mm from FFL - 150mm thick top stripe TNB Red (14238), 150mm thick bottom stripe blue code (11326)
harmonized with the surrounding environment such that they blend/match the neighbouring structures.

4800 (h) 225mm thick Redbrick blast wall

RC roof slab
e sided aluminium sisalation foil, 50mm thick fibreglass wool insulation including flashing, capping

ears warranty certificate


ncrete gutter with approved water proofing membrane with minimum 1500mm overhang

2 x 23W LED T8 bare channel

MSB (100A - PPU / 60A - SSU) Attached


with changeover switch - must 2 nos Floodlight 250 – 300W Attached 1 nos Floodlight 250 – 300W
be mark with the yellow line at Standalone Standalone 1 nos Lantern HPSV 150W
the floor c/w Framed 3 nos Lantern HPSV 150W
Schematic Diagram MSB

1 nos Weatherproof switches


ket using ELCB & Socket Tester 1 nos 20 Amps power point
1 nos 3 phase 20 Amps power point
TRANSFORMER
CABLE CELLAR LT
2 X 30MVA

Standalone Natural ventilation


Attached Mechanical ventilation linked to firefighting system
Ventilation block c/w stainless
steel anti-vermin netting (both
side)

Min. 9 kg port. ABC 2 nos of 9kg ABC portable fire 1 nos of 9kg ABC portable fire
extinguishers c/w labeling / extinguisher c/w weatherproof extinguisher c/w weatherproof
tag, BOMBA certificates and compartment compartment
demarcation line
- wall (50mm red stripe on
white background)
- floor (100mm yellow stripe
with 200mm spacing diagonals
at 45°)
N/A Attached Discharge nozzles (1000mm away from plinth)
Smoke detector Attached Smoke & Heat detector
nel (MFAP) (outside) c/w pictogram/mimic diagram and name tag of installer contractor (SGP)
Gas cylinders c/w demarcation line
Location of cylinders: Not behind opening slot, easy access from exit door
Halocarbons or Inert Gas Manufacturer with Sijil Guna Pakai TNB only

6 x 50mm copper tape - ring 2 nos earth points 1 nos earth points
system + riser to upper floor + 6 x 50 x 300 (l) copper tape 6 x 50 x 300 (l) copper tape
perimeter + earth points 2 nos earthing chamber 1 nos earthing chamber

est point run through 25mm x 3mm copper tape drop to 4 nos earth points/chamber at 4 building corners
at 2.1m height shall be connected with main grid 25mm x 3mm copper strip concealed in concrete
mmØ stainless steel removable handrail, Staircase c/w anti-slip nosing tiles, Finish floor level shall be lower than internal floor level by 50m

r Run*) Catered for double axle trucks carrying 60 tons transformer c/w method statement (as per sample)
TRANSFORMER
CABLE CELLAR LT
2 X 30MVA
(Premix/Reinforced Concrete) road
a) In front of transformer bay - 8000mm (w) and shall be catered for double axle trucks carrying 60
statement
with anticlimb anticut (mesh size: 12.5 x 75 x 4mm Ø) double leaf swing gate c/w cross bar support with min. 4 nos heavy duty roller
nised iron, anticlimb anticut (mesh size: 12.5 x 75 x 4mm Ø) c/w 600mm high razor blade concertina wire
50mmØ stone chipping (1000mm inward and 1000mm outward) at the base 150 mm depth
verts & sump (standalone PPU)** c/w Heavy Duty FRP Grating at all crossings

vidual)** Culverts & sump (standalone PPU)** c/w Heavy Duty FRP Grating at all crossings
(Domestic connection/ Rain water harvesting system/Tube well)**
(Premix/Crusher run*)

8 nos 4000mm (h), 150W HPSV galvanised pole c/w timer and photocell
- Sub DB (external lighting) shall be located at guard house

ete earthing chamber, 50mm x 6mm copper tape with copper connection (crossby clip/cadweld/clamp)
service engineer with proof of calibrated testing equipment (min. every 3 years). The testing method shall comply with IEEE STANDARD 8

Main signboard
TNB Careline, Location: at PPU wall facing the main road
Danger sign, Location: at all four (4) sides of perimeter fencing
No entry sign, Location: at all four (4) sides of perimeter fencing
Safety Excellence Management System (SEMS) symbol
CB NER

Above ground level Above ground level

3000 x 5000 3500 x 5000

4800 4800

Standalone 2000 X 2500 (h) Standalone 2000 x 3000(h)


removable fencing Mild Steel Sliding Door
galvanised frame with hot
dipped galvanised iron with
anticlimb anticut mesh as per
specs (12.5mm x 75mm x 4mm
diameter) c/w latch & hasp

Attached 2000 x 3000 (h) Solid Attached 2000 x 3000 (h) Solid
G.I auto/manual roller shutter G.I auto/manual roller shutter
door linked with firefighting door linked with firefighting
system with closing time less system with closing time less
than 30 seconds than 30 seconds

900 x 2100 (h) 1 hour fire- 900 x 2100 (h) 1 hour fire-
rated mild steel door(next to rated mild steel door(next to
roller shutter) roller shutter)

450 x 600 (Depth clearance 600 x 600 (Depth clearance


from ground beam) from ground beam)
450 x 1500mm slot c/w 600 x 5000mm "L" shape slot
chequered plate c/w chequered plate
CB NER
1200 x 2100 x 150 1500 x 2400 x 150
5 ton 5 ton
Attached Floor Hardener Attached Floor Hardener
Standalone 150mm layer Standalone 150mm layer
thickness 25mm - 38mm Ø thickness 25mm - 38mm Ø
granite chipping granite chipping

ICI Rim Grey (10397) or ICI Rim Grey (10397) or


equivalent equivalent

(11326)
ctures.

4800 (h) 225mm thick Redbrick


blast wall allround c/w ceiling
galvanised frame with hot
blast wall
dipped galvanised iron with
anticlimb anticut mesh
(12.5 x 75 x 4mmØ)

Attached 1 nos Floodlight 250 – 300W


Standalone 1 nos Lantern HPSV 150W

therproof switches
Amps power point
20 Amps power point
CB NER

Natural ventilation
tilation linked to firefighting system

1 nos of 9kg ABC portable fire 1 nos of 9kg ABC portable fire
extinguisher c/w weatherproof extinguisher c/w weatherproof
compartment compartment

zles (1000mm away from plinth)


moke & Heat detector

1 nos earth points 1 nos earth points


6 x 50 x 300 (l) copper tape 6 x 50 x 300 (l) copper tape
1 nos earthing chamber 2 nos earthing chamber

corners

be lower than internal floor level by 50mm

sample)
CB NER

ered for double axle trucks carrying 60 tons transformer c/w method

with min. 4 nos heavy duty roller


a wire

amp)
od shall comply with IEEE STANDARD 81