CAT - PerkinElmer HPLC Consumables
CAT - PerkinElmer HPLC Consumables
HPLC Consumables
Proven Quality, Reliability and Results!
2012-2013 HPLC Consumable Catalogue
ABOUT US
伯森生物科技股份有限公司成立於 1998 年 7 月,
是由一群熱情於工作的夥伴所組成,成員們多數來
自國內生命科學領域的碩士班畢業生,並經過嚴格
的訓練,對於工作始終抱持著熱情、積極、專業及
絕對負責的態度。
伯森公司的成立宗旨是希望以零時差的速度將最新
的知識與技術產品引進國內,為提升國內生物技術
產業研發能量盡一份心力。目前伯森代理的廠牌包
含有:PerkinElmer、Enzo Life Sciences、HANNA
instruments、Wealtec、ibidi、Lucigen、Mirus Bio、
ScienCell、Advanced BioMatrix、Cellendes、
Biochain、Exiqon、Gene Tools、ProSci 等…多家國
際知名生命科學試劑、耗材與儀器廠商。至今伯森
仍持續藉由參加國際研討會及閱讀相關期刊,並經
過審慎專業的篩選與評估,為國內研究領域發掘出
更多優質的技術與產品。
您的建議是我們進步最大的動力與推手,若您有任
何寶貴意見或是任何關於伯森代理產品的疑問,竭
誠歡迎您隨時透過伯森業務專員或是以電話、電子
郵件的方式與我們聯絡,我們將衷心為您服務,謝
謝。
CHROMATOGRAPHY
PerkinElmer has been a leading provider of Chromatography Liquid Chromatography
solutions for over 50 years. Our team of dedicated Chromatog- Accessories - LC/MS 2-3
raphy Specialists has an expertise that boasts years of knowl-
Accessories and
edge in understanding a laboratory's product requirements. This Autosamplers - LC 4-6
knowledge allows us to give you a focused consumables Chromatography Data
portfolio to fit your applications. From colored inlet liners that Systems 7
help you easily identify the correct liner for your application to Vials, Caps and Septa 8-10
gas purification systems that remove up to 99.99% of contami-
Syringe Filters and
nants, our precisiondesigned, genuine tested and approved Disposable Syringes 11
consumables will provide you with solid, reliable support, giving
Solid Phase Extraction
you all you need to succeed. But our solutions don’t stop there. (SPE) 12-15
the best performing and productivity enhancing consumables Sample Loops and
and accessories for all your gas chromatograph systems. Our Tubing 34
consumables can be depended upon to meet the most demand- Fingertight Fittings 35
ing performance and throughput needs for today's analytical, Vacuum Degassing Kits 36
process monitoring and quality control facilities.
Solvent Filtration and
Mixers 37
Detector Lamps 40
Generators 41
www.perkinelmer.com/supplies 1
FLEXAR SQ 300 MS
VERIFY.
QUANTIFY.
SIMPLIFY.
The Flexar SQ 300 MS
Ideal for a variety of analyses, this single quadrupole detector
brings the unsurpassed sample insight of mass spectrometry to
liquid chromatography applications. The Flexar SQ 300 MS™ is an
integral part of the powerful and exible Flexar LC product line. It
features a revolutionary interchangeable probe and unique multi-
stage ion path for exceptional sensitivity.
Measuring has never been easier with the Flexar SQ 300 MS. It
provides the simplest route to exactly the information you need
— quickly. As part of the Flexar LC platform, labs can expect
exceptional chromatography coupled with an innovative rugged
Spare Probe Assemblies / Dielectric Capillary
single quadrapole mass spectrometer that offers:
Description Part No.
• Exceptional front-end chromatographic separation capabilities ESI Probe and Capillary Entrance Cone Kit MZ300503
• Flexible, modular components to suit any LC/MS analytical need Capillary Entrance Cone MZ105094
• idest selection of operating pressures to address ESI Probe MZ109197
throughput needs Dielectric Capillary MZ105057-
60180
The Flexar SQ 300 MS has three ion source options that allow you Quartz Tube for APCI MZ109004
to speci cally address your analytical needs: Corona Needle for APCI MZ301193
Calibration solutions are required for instrument installation and for routine operations.
• Ultraspray™ Electrospray Interface (ESI)
• Dual-probe Ultraspray2™ ESI Calibration Solutions
• Atmospheric Pressure Chemical ionization (APCI)
Description Part No.
Calibration Mix LC/MS (+) ION Mix MZ301198
Powered by the PerkinElmer Chromera® software, instrument
Calibration Mix LC/MS (-) ION Mix MZ301199
control and data acquisition are faster and easier than ever.
Custom Benches
Description Part No.
120V Bench with Ventilated, Sound N2911197
Dampened Pump Enclosure
120V Bench with Monitor/Keyboard Arm, Side Shelf N2911196
and Ventilated, Sound Dampened Pump Enclosure
230V Bench with Ventilated, Sound Dampened N2911199
Pump Enclosure
230V Bench with Monitor/Keyboard Arm, Side Shelf N2911198
and Ventilated, Sound Dampened Pump Enclosure
Roughing Pump Box with Acoustically Insulated N8141230
Pump Enclosure
Uninterrupted Power Supply (UPS) N0777511
Sound Reducing Pump Box MZ301123 9 mm Blue Screw Top Cap with Clear 100
Non-slit PTFE/Silicone (LC Clean)
www.perkinelmer.com/supplies 3
FLEXAR UHPLC
POWER AND
NEW
FLEXIBILITY
IN UHPLC FX-15
ULTRA HIGH
PERFORMANCE LC
18,000 PSI
FX-10
ULTRA HIGH
PERFORMANCE LC
10,000 PSI
LC
CONVENTIONAL LC
6,000 PSI
PERFORMANCE
LC
CONVENTIONAL LC
MANUAL INJECTION
ar UHPLC
Flexar UHPLC Systems
• Improved separa iency
• Up to 90% reduction in solvent cons ving you money Description Part No.
Flexar FX-15 UHPLC Platform NFLR0215
• Up to 10x productivity g g you do more in less time
Flexar FX-15 UHPLC Pump N2910531
“Flexar Bottle Manager, 3-channel Vacuum N2600581
Degassing” Tubing Kit
Static Mixers are important in facilitating complete mobile phase Description Part No.
blending, resulting in improved retention performance. These Replacement 0.5 µm Filter Frits for FX-15 (4-pack) N2911224
mixers should be used as part of FX10, or FX15 LC systems, where High Pressure FX-15 Piston Seal Kit N2911221
high pressure blending is required. Mixers incorporate a highly (Need 4 per FX-15)
ef cient cross- w shearing mechanism which produces vortex Piston Wash Bottle Kit N2601616
sheer mixing over a wide range of volumes. They are now offered 2,500 µL Sample Syringe Starting Kit N2930313
in 18,000 psi pressure max avor.
A good rst choice selection is a volume of about half the w rate
FX-10 and FX-15 UHPLC System Accessories
volume. For example, when pumping at a 0.5 mL/min w rate, a Description Color Size Part No.
350 μL mixer provides good mixing with very good baseline stability. ID PEEK Tubing
0.004" Black 50 cm N2916200
Description Part No.
0.005" Red 50 cm N2916056
Assembly, SS N2911200
0.004" Black 76 cm N2916260
Assembly, SS N2911201
0.005" Red 66 cm N2916262
Assembly, SS N2911202
Connector Tubing, Stainless Steel
Assembly, SS N2911205
Flexar ISO/Binary/Quaternary Pump to Autosampler N2916210
Assembly, SS N2911203
Dual Mixer Connection (≤ 250 µL) N2916216
150 L High Pressure Binary High Pressure Mixing-T, SS N2911206
Dual Mixer Connection (³350 µL) N2916217
, SS N2911170
FX-10 Pump A (Upper) to T-mixer N2916213
Binary High Pressure T-Mixer, SS, N2911212
FX-10 Pump B (Lower) to T-mixer N2916214
Binary High Pressure T-Mixer, SS, N2911210
FX-10 Purge Valve to Filter/Scavenger N2916212
Binary High Pressure T-Mixer, SS, N2911211
FX-10 Injector to Column N2916215
T-connector, SS N2911127
FX-10 Pump A (Upper) to Dual Mixers N2916218
FX-10 Pump B (Lower) to Dual Mixers N2916219
Syringes and Kits FX-15 Pump to In-line Mixer N2916222
PerkinElmer syringe kits for high pressure applications are FX-15 Pump to Dual Mixers N2916224
manufactured for precise liquid delivery. All of these glass syringes FX-15 Injector to Column, Standard N2916223
come with precision stainless steel plungers. They are used for FX-15 Injector to Column, 33 cm N2916201
sampling and shing and are available in a large variety of sizes. 3 cm Scavenger Cartridge Holder 02580178
Syringes Spheri5 Scavenger Columns (5-pack) 02580202
30 mL Priming Syringe 09904849
Description Part No.
FX-15 C18 Scavenger Column Kit N2910765
Sample Needle w/Fittings N2936009
FX-15 C18 Scavenger Columns (2/pkg) 02580223
Air Guide Needle (62 mm) N2936000
Bio Compatible Sample Needle w/Tubing Connector N2936010
Needle (80 mm) N2936342 Microsyringes (For Manual Injection)
Syringes are used for accurate and precise liquid delivery. Each
Syringe Kits
syringe is hand- tted to assure maximum accuracy. Our syringes
Dimension Buffer Tubing Part No. are composed of glass barrels and precision stainless steel
100 µL 200 µL N2936051 needles. The needle features a blunt tip, required for use with a
250 µL 500 µL N2936052 Rheodyne injector.
500 µL 1,000 µL N2936053
Description Part No.
1,000 µL 2,000 µL N2936054
10 µL Syringe 09904937
2,500 µL 2,000 µL N2936055
25 µL Syringe 09904823
50 µL Syringe 09904941
100 µL Syringe 09904822
Rheodyne 22-gauge Blunt Needle with Luer Hub 09904943
www.perkinelmer.com/supplies 5
FLEXAR AUTOSAMPLERS
INJECT WITH
GREATER PRECISION
Flexar Autosamplers
Best-in-class cycle time. Wide injection volume range. Excellent
injection reproducibility. Precisely what you need to increase your
sample throughput and ef ciency. Flexar or Series 225/275
Autosampler Trays and Accessories
Features and Be Description Part No.
• Injects sample volumes as l t pressures up to 18,000 psi 25-Position 6 mL Vial Sample Tray N2936045
with the FX UHPLC Autosampler
80-Position 2 mL Vial plus (5) 6 mL Vial Tray N2936046
• Loads sample in only 8 seconds (in parti ll mode) (for derivatization)
• ee injection modes: full loop, parti ll and µL-pickup with no 80-Position 2 mL Vial Tray with Dilution Tray N2930676
sample waste 96-well Microtiter Adapter N9302562
• Peltier cooling/heating mode option for operation at 4 °C to 40 °C. 96-well ‘Deep-well’ Microtiter Adapter N9302560
Will reach 4 °C ± 2 °C, achievable even at ambient temperatures up 96-well 7 mm Pre-slit Silicone Plate Mat/Seal N9302555
to 25 °C.
96-well ‘Deep’ Microtiter Plate Adaptor N2936048
(Supports Dual Microtiter Plates)
All Flexar autosamplers can be upgraded in the eld for Peltier 96-well ‘Shallow’ Microtiter Plate Adaptor N2936049
cooling and heating. All Flexar autosamplers include: (Supports Dual Microtiter Plates)
• 100‐sample tray • Service Manager SW CD 384-well Microtiter Adapter N2936050
• 100 2 mL vials • User’s Manual 100-Position 2 mL Vial Sample Tray N2936042
• 100 2 mL screw top cap with • Nuts and ferrules (200) 0.2 mL Microvial plus (5) 2 mL Vial Tray N2936043
cross slit vial septum • All fuses for 120–240 V 250 µL Syringe Tip Replacements (10/pkg) N2936003
• Tubing to connect to • All cables required for connection Flexar/225 Biocompatible Upgrade Kit (w/valve) N2930675
waste reservoir to a TotalChrom or Chromera
⁄16" OD x 0.038" ID Te on Tubing (AS Transfer Line)
1
02506495
• I/O cable (Pump Start/Ready‐In) Operating Environment
CHROMERA® CHROMATOGRAPHY
DATA SYSTEM NEW
THE POWERFULLY EASY CDS
One click and you’ll see: CDS doesn’t get any easier than Chromera. Combining intuitive
, Chromera delivers the most
streamlined way to get from the analysis you need to the information your enterprise
demands. It’s powerfully easy.
Featur
Powerful Easy
• Instrument Control: NEW patented “Device Descriptors” control • Shallow footprint GUI: Most functions only one or two clicks away,
instruments. No channels limitation, trackable instrument status using familiar Micr ™ Outlook user interface
• Designed for UHPLC: interactive graphical methods optimization • Simple and obvious method editor: a single-point access to
environment with immediate feedback; ability to overlay pressure all instrument parameters, regardless of how complex the
pr le r er run. Extend runtime of chromatogram in real time instrument c uration; Convenient tools for point-and-click
method optimization
• Graphics: Multichannel graphics for multiple signal channel
monitoring (including system status channels to get ‘the pulse • Intuitive Sequence Wizard: Create complex sample tables easily;
of the system’ real-time) Convenient auto ll and other editing functions; Decision Points
for real-time and post-processing data evaluation
• Feedback: Instrument-at-a-glance status panel provides real-time
feedback of complete LC system • Peak Integration Wizard: Makes integration process easy and straight
forward
• Batch Sequencing: all the f g up and reviewing a
sequence and results are within a single environment • Report Wizard: allows creating numerous styles of reports and
printouts using the same tool
www.perkinelmer.com/supplies 7
FLEXAR AUTOSAMPLER ACCESSORIES
LC VIALS, CAPS
AND SEPTA KITS
PerkinElmer Supplies – Tested and Approved 2.0 mL Caps and Septa*
We have expanded our product selection to include additional vial Description Pkg. Part No.
types, new version caps and mating septa in a kit format for easier 11 mm Snap Cap Polyethylene 1,000 04978532
customer ordering. The following pages contain both current Cross-cut Slit (no Septum)
and new product information. Tested to meet your application 11 mm Snap Cap Polyethylene 1,000 N9307023
requirements and guaranteed for t and compatibility. Single Slit (no Septum)
8 mm Black Screw Caps (without septa) 100 N9303441
PerkinElmer offers a variety of vials, caps and septa to ful ll 8 mm Screw Cap PTFE/Silicone Septa 100 N9303449
your application needs. Our screw thread vial caps use the
9 mm PTFE/Silicone Screw Cap Blue 100 N9306202
revolutionary Inter-Seal®. Using a process that bonds silicone/
10 mm PTFE/Red Rubber Screw Cap Black 100 N9306206
PTFE and other elastomeric compounds directly into thermoplastic
10 mm PTFE/Silicone Single Slit 100 N9306052
closures eliminates liner fallout, while still providing the excellent Screw Cap Black
resealability and multiple injection capability. No adhesives are
10 mm PTFE/Silicone No Slit Screw Cap Black 100 N9306205
used in this process, bonding the cap and septa at the molecular
11 mm Crimp Green Aluminum Cap 100 N9302684
level of plastic and rubber. These septa have a very broad w/T ®
Rubber Septa
chemical resistance and can be used in many markets including: 11 mm Crimp Red Aluminum Cap 100 N9302685
environmental, diagnostic packaging, pharmaceutical packaging, w/T ®
Rubber Septa
cosmetic and food packaging. 11 mm Crimp Blue Aluminum Cap 100 N9302686
w/T ®
Rubber Septa
UHPLC – General Starter Kit N2930801 5' x 0.007" ID 1⁄16" PEEK Tubing, Yellowish- 1 N9302650
Tan
Contents Qty/Pack Part No. 5' x 0.005" ID 1⁄16" PEEK Tubing, Red 1 N2916262
Open-End Wrench 2 09907233 30 mL Priming Syringe 1 09904849
Adjustable Wrench 1 N9301326 2 mL clear write-on vials w/10 mm Pre-Slit 1 N9300695
Reversible Screw Driver 1 N9301480 PTFE/Silicone Caps; 100/pk
Parker 10 09903980
1
⁄16" Parker errules 10 00873032
1
⁄16" Valco SS Ferrules 6 09903891
Finger-Tight Fittings, PEEK, 5.5K psi Max. 1 N9307822 Autosampler Vial Glass Inserts
(5/pk)
Optimize Technologies EZP (Hand-Tight 1 N9306301 Description Pkg. Part No.
Fitting to 13K psi, Wrench-tight to 20K psi) Vial Glass Inserts:
1
⁄16" Tefzel Nuts 2 09920381 6 mm x 29 mm Clear Glass Insert, Rimless Pulled 100 N9300703
1
⁄16" Tefzel Reverse Ferrules 2 09920382 Point with Bottom Spring, 250 μL Usable Volume
1
⁄8" Tefzel Nuts 4 N2601189 6 mm x 31 mm Clear Glass Flat Bottom Insert, 100 N9300704
400 μL Usable Volume
1
⁄8" Tefzel Reverse Ferrules 4 09903771
Use with: N9306057
PEEK Tubing Cutter (Includes 5 Extra Blades) 1 N9307820 10 mm 2 mL Amber Screw Top Vial
50 cm x 0.005" ID 1⁄16" SS Tubing 3 02507060 w/White “P” Icon w/Patch
5' x 0.004" ID 1⁄16" PEEK Tubing, Black 1 N2916261 10 mm 2 mL Clear Screw Top Vial N9306053
w/White “P” Icon w/Patch
5' x 0.005" ID ⁄16" PEEK Tubing, Red
1
1 N2916262
11 mm Clear Large Opening Snap Ring Vial N9303418
30 mL Priming Syringe 1 09904849 w/Black “P” Icon
2 mL Clear Write-On Vials w/10 mm Pre-Slit 1 N9300695 11 mm Clear Large Opening Crimp Vial N9306231
PTFE/Silicone Caps; 100/pk w/Black “P” Icon
Cable/Tubing Organizer Clip 3 NX598006 9 mm 2 mL Amber Screw Top Vial w/Black “P” Icon N9306220
9 mm 2 mL Clear Screw Top Vial w/Black “P” Icon N9306201
HPLC – General Starter Kit
5 mm x 29 mm Clear Glass Insert, Rimles Pulled 100 N9300705
Description Part No. Point with Bottom Spring, 150 μL Usable Volume
HPLC – General Starter Kit N2930802 5 mm x 31 mm Clear Glass Flat Bottom Insert, 100 N9300706
200 μL Usable Volume
Contents Qty/Pack Part No. Use with:
Open-End Wrench 2 09907233 11 mm Standard Amber Crimp Vial w/Black “P” Icon N9302680
Adjustable Wrench 1 N9301326 11 mm Standard Clear Crimp Vial w/Black “P” Icon N9301385
Reversible Screw Driver 1 N9301480 8 mm 2 mL Clear Screw Top Vial w/Black “P” Icon N9302945
www.perkinelmer.com/supplies 9
EASY-TO-ORDER CONVENIENCE KITS
™
Kits (Vials and Caps/Septa sold separately.)
NEW
Description Pkg. Part No.
™
Non-Slit Cap/Vial Convenience Kit (Pkg. of 100) 100 N9300707
9 mm 2 mL Screw Top Clear Vial with 9 mm Blue Screw Top Cap Clear Non-Slit PTFE/Silicone (LC Clean™)
™
Pre-Slit Cap/Vial Convenience Kit (Pkg. of 100) 100 N9300708
9 mm 2 mL Screw Top Clear Vial with 9 mm Gray Screw Top Cap Clear Pre-Slit PTFE/Silicone (LC Clean™)
NEW ™
Non-Slit Cap/Vial Convenience Kit (Pkg. of 100) 100 N9300719
9 mm 2 mL Screw Top Amber Vial with 9 mm Blue Screw Top Cap Clear Non-Slit PTFE/Silicone (LC Clean™)
NEW ™
Pre-Slit Cap/Vial Convenience Kit (Pkg. of 100) 100 N9300720
9 mm 2 mL Screw Top Amber Vial with 9 mm Gray Screw Top Cap Clear Pre-Slit PTFE/Silicone (LC Clean™)
Syringe Filters
Size Color Pkg Part No.
Nylon
0.22 μm, 4 mm Clear 200 02542900
0.45 μm, 4 mm Clear 200 02542901
0.22 μm, 13 mm Purple 100 02542902
Vials with Fused Glass Sample Inserts 0.45 μm, 13 mm Purple 100 02542903
2 mL 11 mm Large Opening Crimp Top 100 N9300709 0.45 μm, 17 mm Yellow 100 02542880
0.22 μm, 25 mm Purple 100 02542904
2 mL 11 mm Large Opening Crimp Top 100 N9300710 0.45 μm, 25 mm Purple 100 02542905
Amber 0.3 mL Insert
0.22 μm, 30 mm Yellow 100 02542883
2 mL 11 mm Large Opening Snap Top Ring 100 N9300711
Clear 0.3 mL Insert 0.45 μm, 30 mm Yellow 100 02542882
2 mL 10 mm Large Opening Screw Top 100 N9300717 0.22 μm, 25 mm Red 100 02542911
Clear 0.3 mL Insert 0.45 μm, 25 mm Red 100 02542912
2 mL 10 mm Large Opening Screw 100 N9300718 0.22 μm, 30 mm Red 100 02542886
Amber 0.3 mL Insert
0.45 μm, 30 mm Red 100 02542885
PVDF
Liquid Chromatography Laboratory Bottle Kits
0.22 μm, 4 mm Clear 200 02542913
Description Part No.
0.45 μm, 4 mm Clear 200 02542914
1x5L Bottle with Cap and T 2m PTFE N2601610
0.22 μm, 13 mm Yellow 100 02542915
1
⁄8" Tubing and 1x10um SS Solvent Frit
0.45 μm, 13 mm Yellow 100 02542783
1x2L Bottle with Cap and T 1m PTFE N2601611
1
⁄8" Tubing and 1x10um SS Solvent Frit 0.22 μm, 17 mm Maroon 100 02542916
1x1 L Bottle with Cap and T 1m PTFE N2601612 0.45 μm, 17 mm Maroon 100 02542917
1
⁄8" Tubing and 1x10um SS Solvent Frit
0.22 μm, 25 mm Yellow 100 02542918
1x0.5L Bottle with Cap and T 1m PTFE N2601613
0.45 μm, 25 mm Yellow 100 02542919
1
⁄16" Tubing and 1x40um SS Solvent Frit
0.22 μm, 30 mm Maroon 100 02542920
1 Cap with T 1m PTFE 1⁄8" Tubing and N2601614
1x10um SS Solvent Frit 0.45 μm, 30 mm Maroon 100 02542921
1 Cap with T 1m PTFE 1⁄16" Tubing and N2601615 PTFE (Hypdrophilic)
1x40um SS Solvent Frit
0.22 μm, 4 mm Clear 200 02542922
1x0.5L Bottle with Cap and Dual T N2601616
0.45 μm, 4 mm Clear 200 02542923
2 pcs of 1m PTFE 1⁄8" Tubing (Piston Wash Function)
0.22 μm, 13 mm Red 100 02542924
1 Cap with Dual Te on Insert, 2 pcs of 1 m PTFE N2601617
1
⁄8"Tubing and 1x10um SS Solvent Frit (Piston 0.45 μm, 13 mm Red 100 02542925
Wash Function)
0.22 μm, 25 mm Red 100 02542926
0.45 μm, 25 mm Red 100 02542927
Disposable Syringes
0.22 μm, 30 mm Red 100 02542928
Description Part No. 0.45 μm, 30 mm Red 100 02542929
Disposible Syringes, Luer-Lock Tips, 1 mL (100PK) 02542890
Disposible Syringes, Luer-Lock Tips, 3 mL (200PK) 02542891
Disposible Syringes, Luer-Lock Tips, 5 mL (100PK) 02542892
Disposible Syringes, Luer-Lock Tips, 10 mL (100PK) 02542893
www.perkinelmer.com/supplies 11
SOLID PHASE EXTRACTION (SPE)
Supra-Clean and
Supra-Poly SPE Solutions
Manufactured for guaranteed reproducibility and superior
performance, this innovative line of SPE solutions includes the
Supra-Clean® silica based and Supra-Poly® polymer based line of SPE Manifolds, Selection Kits and Application Packs
spherical media SPE cartridges and columns.
For greater method development simplicity and sample
Both utilize Precise Bed Technology® allowing columns to be throughput, PerkinElmer offers a variety of pre-prepared column
selection kits as well as application kits for you to choose from.
bed volume precision, ensuring you experience repeatability and SPE Manifolds:
optimized recovery reproducibility. • Allow you to process up to 24 samples simultaneously
Ideal for a broad array of analytes and matrices, SPE solutions are • Seamlessly integrate with columns to extend the system’s
available in a variety of formats including Large Reservoir Capacity performance and reproducibility
(LRC) columns, Polypropylene (PP) columns and cartridges, and • Feature polypropylene or stainless steel needle valves and tips
glass columns. Each technology is offered with a wide selection of with minimum dead volume
polymer and silica sorbents, and large and small sample volumes • Rugged stopcocks are reusable and provide independent
(50μL-1L) allow you to perform scalable analyses depending upon w control
your required detection limits.
oduct is delivered with an individual quality
12 V1
6
V2
IR60-40/63SI
Competitor SPE Supra-Clean
SPE Column SPE Column 60-50SI
0 V1 < V2
2 4 6
Spherical media and consistent particle distribution enable smaller elution
volumes and better, more reproducible extraction, purification, concentration PerkinElmer’s smaller, more homogeneous, spherical media deliver
and recovery. sharper, narrower peaks for faster, more accurate sample analysis.
• Rugged stopcocks are reusable and provide independen w control Stopcocks 24 Positions 24 N9306631
Vacuum Manifold Complete Set 12 Positions 12 N9306619
Vacuum Manifold Complete Set 24 Positions 24 N9306626
SPE Selection Kits
Selection kits enable quick column selection for development of reproducible and repeatable SPE methods.
www.perkinelmer.com/supplies 13
SOLID PHASE EXTRACTION (SPE)
www.perkinelmer.com/supplies 15
BROWNLEE SPP COLUMNS
INNOVATION
SPP Particle Technology
TO THE CORE
1.7 µm 2.7 µm
* Maximum pressure 9,000 p.s.i. for all columns. All particle sizes are 2.7 µm.
**Not end-capped. All others end-capped.
THE TECHNOLOGY
YOU NEED TO SEPARATE
FROM THE PACK
Brownlee Instrument Optimizaton Kits
Brownlee SPP columns can be used to enhance the performance
of virtually any PerkinElmer, Agilent, or other manufacturer’s HPLC
or UHPLC system. Our SPP columns deliver resolution and speed
similar to sub-2 μm UHPLC columns, but generate only 40% to
50% of the backpressure. By combining high ef
backpressure, Brownlee SPP columns make it possible to get
“UHPLC-like” performance from your HPLC system.
• Generate UHPLC like separations on your standard HPLC system
PerkinElmer has created, tested and made the following
• Achieve ultra fast performanc iency on your
PerkinElmer and Agilent optimization kits available. Our
UHPLC system
OneSource Service Engineers ar
• Run samples in a fraction of the time
manufacturer instruments and can help optimize your
instrument’ • Experience signi vings through faster method development,
column longevity and use of less mobile phase solvent
PerkinElmer Optimization Kits
Description Part No.
Series 200 LC or Flexar UHPLC systems N2920191
with UV/Vis detector
Series 200 LC or Flexar UHPLC systems N2920193
with PDA detector
www.perkinelmer.com/supplies 17
SPP
Performance For Every Phase Diameter/Length Part No. Diameter/Length Part No.
4.6 x 30 mm N9308430 4.6 x 50 mm N9308493
Brownlee SPP 2.7 µm Columns
4.6 x 50 mm N9308431 4.6 x 75 mm N9308494
Diameter/Length Part No. 4.6 x 75 mm N9308432 4.6 x 100 mm N9308495
C18 4.6 x 100 mm N9308433 4.6 x 150 mm N9308496
2.1 x 20 mm N9308400 4.6 x 150 mm N9308434 RP-Amide
2.1 x 30 mm N9308401 PFP 2.1 x 20 mm N9308497
2.1 x 50 mm N9308402 2.1 x 20 mm N9308465 2.1 x 30 mm N9308498
2.1 x 75 mm N9308403 2.1 x 30 mm N9308466 2.1 x 50 mm N9308499
2.1 x 100 mm N9308404 2.1 x 50 mm N9308467 2.1 x 75 mm N9308500
2.1 x 150 mm N9308405 2.1 x 75 mm N9308468 2.1 x 100 mm N9308501
3.0 x 20 mm N9308406 2.1 x 100 mm N9308469 2.1 x 150 mm N9308502
3.0 x 30 mm N9308407 2.1 x 150 mm N9308470 3.0 x 30 mm N9308503
3.0 x 50 mm N9308408 3.0 x 30 mm N9308471 3.0 x 50 mm N9308504
3.0 x 75 mm N9308409 3.0 x 50 mm N9308472 3.0 x 75 mm N9308505
3.0 x 100 mm N9308410 3.0 x 75 mm N9308473 3.0 x 100 mm N9308506
3.0 x 150 mm N9308411 3.0 x 100 mm N9308474 3.0 x 150 mm N9308507
4.6 x 20 mm N9308412 3.0 x 150 mm N9308475 4.6 x 30 mm N9308508
4.6 x 30 mm N9308413 4.6 x 30 mm N9308476 4.6 x 50 mm N9308509
4.6 x 50 mm N9308414 4.6 x 50 mm N9308477 4.6 x 75 mm N9308510
4.6 x 75 mm N9308415 4.6 x 75 mm N9308478 4.6 x 100 mm N9308511
4.6 x 100 mm N9308416 4.6 x 100 mm N9308479 4.6 x 150 mm N9308512
4.6 X 150 mm N9308417 4.6 x 150 mm N9308480 C18 Guard Column Packs
Peptide ES-C18 HILIC 2.1 x 5 mm, 3 pk N9308513
2.1 x 30 mm N9308450 2.1 x 30 mm N9308435 3.0 x 5 mm, 3 pk N9308514
2.1 x 50 mm N9308451 2.1 x 50 mm N9308436 4.6 x 5 mm, 3 pk N9308515
2.1 x 75 mm N9308452 2.1 x 75 mm N9308437 C8 Guard Column Packs
2.1 x 100 mm N9308453 2.1 x 100 mm N9308438 2.1 x 5 mm, 3 pk N9308522
2.1 x 150 mm N9308454 2.1 x 150 mm N9308439 3.0 x 5 mm, 3 pk N9308523
3.0 x 30 mm N9308455 3.0 x 30 mm N9308440 4.6 x 5 mm, 3 pk N9308524
3.0 x 50 mm N9308456 3.0 x 50 mm N9308441 HILIC Guard Column Packs
3.0 x 75 mm N9308457 3.0 x 75 mm N9308442 2.1 x 5 mm, 3 pk N9308525
3.0 x 100 mm N9308458 3.0 x 100 mm N9308443 3.0 x 5 mm, 3 pk N9308526
3.0 x 150 mm N9308459 3.0 x 150 mm N9308444 4.6 x 5 mm, 3 pk N9308527
4.6 x 30 mm N9308460 4.6 x 30 mm N9308445 Peptide ES-C18 Guard Column Packs
4.6 x 50 mm N9308461 4.6 x 50 mm N9308446 2.1 x 5 mm, 3 pk N9308528
4.6 x 75 mm N9308462 4.6 x 75 mm N9308447 3.0 x 5 mm, 3 pk N9308529
4.6 x 100 mm N9308463 4.6 x 100 mm N9308448 4.6 x 5 mm, 3 pk N9308530
4.6 x 150 mm N9308464 4.6 x 150 mm N9308449 PFP Guard Column Packs
C8 Phenyl-Hexyl 2.1 x 5 mm, 3 pk N9308531
2.1 x 20 mm N9308418 2.1 x 20 mm N9308481 3.0 x 5 mm, 3 pk N9308532
2.1 x 30 mm N9308419 2.1 x 30 mm N9308482 4.6 x 5 mm, 3 pk N9308533
2.1 x 50 mm N9308420 2.1 x 50 mm N9308483 Phenyl-Hexyl Guard Column Packs
2.1 x 75 mm N9308421 2.1 x 75 mm N9308484 2.1 x 5 mm, 3 pk N9308519
2.1 x 100 mm N9308422 2.1 x 100 mm N9308485 3.0 x 5 mm, 3 pk N9308520
2.1 x 150 mm N9308423 2.1 x 150 mm N9308486 4.6 x 5 mm, 3 pk N9308521
3.0 x 30 mm N9308424 3.0 x 30 mm N9308487 RP-Amide Guard Column Packs
3.0 x 50 mm N9308425 3.0 x 50 mm N9308488 2.1 x 5 mm, 3 pk N9308516
3.0 x 75 mm N9308426 3.0 x 75 mm N9308489 3.0 x 5 mm, 3 pk N9308517
3.0 x 100 mm N9308427 3.0 x 100 mm N9308490 4.6 x 5 mm, 3 pk N9308518
3.0 x 150 mm N9308428 3.0 x 150 mm N9308491 Guard Column Holder
4.6 x 20 mm N9308429 4.6 x 30 mm N9308492 N9308534
• Packed to withstand higher operating pressures Brownlee HRes Analytical DB PAH 50 mm N9303995
• Wide choice of stationary phases Brownlee HRes Analytical DB PAH 100 mm N9303996
End Carbon
Phase Cap? Load Applications Chromatographic Properties
C18 Y 11 Hydrophobic C18 Phase suitable for analyses of a wide range of Highly base-deactivated spherical silica. Monomeric C18 bonding.
compounds, from acidic through slightly basic.
Aqueous N 6 Ideal for applications that require highly aqueous mobile phases, Highly selective phase for polar analytes. Compatible with highly aqueous (up to
C18 such as organic acids and water-soluble vitamins. 100%) mobile phases.
Biphenyl Y 8 Excellent choice for the analysis of steroids, tetracyclines, drug Highly base-deactivated spherical silica. Unique reversed phase material that displays
metabolites, and other compounds that contain some degree both increased retention and selectivity for aromatic and/or unsaturated compounds
of unsaturation. when compared to conventional alkyl and phenyl phases.
PFPP Y 6 Exhibits excellent peak shapes for a wide range of compounds, Highly base-deactivated spherical silica.
including nucleosides, nucleotides, and halogenated compounds. propyl spacer.
IBD N - Intrinsically base-deactivated (IBD) phases, with a polar group within, or intrinsic to,
selectivity of acids, for symmetrical peak shapes of bases and for the alkyl bonded phase. Provides unique selectivity and a high level of base deacti-
the analysis of zwitterions and other polar compounds. vation while reducing or eliminating the need for mobile phase additives.
Silica - - Normal phase mode of separation. Highly base-deactivated spherical silica.
C8 Y 7 Superior general purpose C8 for non-basic analytes. Provides shorter retention times for hydrophobic compounds than C18.
PAH Y - Maximum resolution of polycyclic aromatic hydrocarbons. Proprietary stationary phase; resloves 16 PAHs in US EPA Method 610.
Cyano Y 4 Superior general purpose cyano for weakly-basic analytes. Used in More rugged than bare silica for normal phase analyses.
either normal or reversed phase analyses.
Pore Size A = 140, pH Range = 2.5-8, Temp Limit = 80°C, Particle Size = 1.9 µm
www.perkinelmer.com/supplies 19
CONVENTIONAL COLUMNS
Brownlee Bio
This material is wide-pore silica (300 Å) that is excellent for peptide
250 mm, 100 mm Microbore Columns (1.0 mm i.d.)
and protein separation. Columns are available in 5 µ and lengths
ranging from 30–250 mm, in 2.1 and 4.6 i.d. in C8 and C18 phases.
Brownlee Microbore HPLC Columns
Microbore columns (1.0 mm i.d.) are ideal for the analysis of Brownlee CHOICE™
samples of limited availability (e.g., micropuri cation of picomole This line of columns is made of (60 Å) silica which results in large
levels of proteins/peptides). Reducing the column diameter from surface area, high carbon loads, and high retention compounds.
the standard 4.6 mm to 1.0 mm increases the mass sensitivity by 20 Columns are available in 3 or 5 µm and lengths ranging from
times. Sample components can be collected in small elution volumes 30–250 mm, in 2.1 and 4.6 i.d. The Brownlee Choice family
(1–50 µL) for further sequence or mass analysis. Microbore offers includes the Basix, C18, Organic Acids, and PFP Propyl phases.
major bene ts in pharmacokinetic assays and LC/MS applications.
The typical w rate range is 10–100 µL/min., therefore specialized Brownlee Spheri-5®
HPLC systems may be required for optimum column performance. This is a small-pore (80 Å, 5 µm), silica based sorbent for separating
small molecules. Both monofunctional (comb-pre) and polyfunctional
Features and Be (polymerized loop-type) C8 and C18 sorbents available.
• Increase sensitivity and decrease solvent consumption by a factor of Brownlee Validated™
20 (compared with 4.6 mm i.d.)
These columns are made on high-purity, Type B silica with
• Reduce sample size for pharmacokinetic assays inherent low silanophilic activity. It exhibits excellent peak shape
• Be er compatibility with LC/MS interfaces for a wide range of compounds while also having a wide number
of phases. The Brownlee Validated columns are the best choice
• Each column is individually tested
for pharmaceutical applications that deal with a lot of basic or
multi-functional compounds. Columns are available in 3 or 5 µ
and lengths ranging from 30–250 mm, in 2.1 and 4.6 i.d., and
Modes of Separation include Amino, C18, C8, Carbamate, Cyano, IBD (intrinsically
Reversed-Phase Chromatography (RPC) is the most popular base-deactivated), PFP (penta rophenyl) and phenyl phases.
HPLC mode and is used in 60–80% of all applications. In RPC,
hydrophobic groups (C18, C8, or C4) bonded to a silica support Guard Columns and Cartridges
are used together with a mobile phase of water and organic To protect your column investment, we offer a complete line of
solvent (e.g. methanol, acetonitrile). guard columns in our direct connect guard cartridges. These can
Polar Phase (Normal Phase) Chromatography (NPC) uses a be attached to any column offered above. You can easily select the
polar stationary phase (unbonded silica, bonded amino or cyano phase type to the appropriate guard column packing to ensure a
group) together with a non-polar mobile phase (e.g., hexane). correct silica match.
Brownlee Columns
Choose only genuine PerkinElmer Brownlee™ columns for the
best separation results. Six different column types to meet all your
analytical needs.
Features and Be
• Each column individually tested and certi te provided
•E ings compatible with a variety of HPLC systems
• Do not require MPLC holders
www.perkinelmer.com/supplies 21
CONVENTIONAL COLUMNS
Phase Length ID Particle Size Part No. Phase Length ID Particle Size Part No.
C8 30 mm 4.6 mm 5 µm N9303521 PAH 100 mm 4.6 mm 5 µm N9303527
C8 100 mm 4.6 mm 5 µm N9303515 PAH 150 mm 3.2 mm 5 µm N9303430
C8 150 mm 4.0 mm 5 µm N9303516 PAH 150 mm 4.6 mm 5 µm N9303529
C8 150 mm 4.6 mm 5 µm N9303517 PAH 200 mm 4.6 mm 5 µm N9303528
C8 200 mm 4.6 mm 5 µm N9303518 PAH 250 mm 2.1 mm 5 µm N9303530
C8 250 mm 4.0 mm 5 µm N9303519 PAH 250 mm 4.6 mm 5 µm N9303531
C8 250 mm 4.6 mm 5 µm N9303520
Brownlee Analytical Phenyl
Brownlee Analytical C18 Unique selectivity especially for aromatic compounds.
Suitable for a wide range of acidic to neutral hydrophobic pH range: 2.5 to 7.5 - Temperature limit: 80° C
compounds. Excellent all purpose column. Carbon load: 6% - Pore size: 110 Å - End Cap: Yes
pH range: 2.5 to 7.5 - Temperature limit: 80° C
Phase Length ID Particle Size Part No.
Pore size: 110 Å - Carbon load: 13% - End Cap: Yes
Phenyl 150 mm 4.6 mm 5 µm N9303524
Phase Length ID Particle Size Part No.
C18 30 mm 4.6 mm 3 µm N9303509 Brownlee Analytical Silica
C18 50 mm 4.6 mm 3 µm N9303510 Good general purpose packing for normal phase separations.
C18 100 mm 4.6 mm 3 µm N9303507
pH range: 2.5 to 7.5 - Temperature limit: 80° C
C18 150 mm 4.6 mm 3 µm N9303508
Pore size: 110 Å - End Cap: No
C18 100 mm 4.0 mm 5 µm N9303511
C18 100 mm 4.6 mm 5 µm N9303512 Phase Length ID Particle Size Part No.
www.perkinelmer.com/supplies 23
CONVENTIONAL COLUMNS
Brownlee CHOICE Basix Highly retentive for basic analytes. Excellent separation of
nucleosides, nucleotides, purines, pyrimidines halogenated
Excellent choice for analytes containing amine
compounds, beta blockers and tricyclic antidepressants.
group functionality.
pH range: 2.5 to 7.5 - Temperature limit: 80° C -
pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Pore Size: 60 Å - Carbon Load: 17% - End Cap: Yes
Pore Size: 60 Å - Carbon Load: 12% - End Cap: Yes
Phase Length ID Particle Size Part No.
Phase Length ID Particle Size Part No.
PFP Propyl 30 mm 2.1 mm 5 µm N9303640
Basix 50 mm 2.1 mm 5 µm N9303615
PFP Propyl 50 mm 2.1 mm 5 µm N9303641
Basix 50 mm 4.6 mm 5 µm N9303616
PFP Propyl 50 mm 4.6 mm 5 µm N9303642
Basix 100 mm 2.1 mm 5 µm N9303613
PFP Propyl 100 mm 2.1 mm 5 µm N9303638
Basix 100 mm 4.6 mm 5 µm N9303614
PFP Propyl 100 mm 4.6 mm 5 µm N9303639
Basix 150 mm 2.1 mm 5 µm N9303617
PFP Propyl 150 mm 2.1 mm 5 µm N9303643
Basix 150 mm 4.6 mm 5 µm N9303618
PFP Propyl 150 mm 4.6 mm 5 µm N9303644
Basix 250 mm 4.6 mm 5 µm N9303619
PFP Propyl 250 mm 4.6 mm 5 µm N9303645
Brownlee Validated™ Amino High bonding coverage and base deactivation. Less retention than
C18 or C8 phases.
Good for normal phase analytes of mono- and disaccharides or
similar compounds. pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Pore Size: 100 Å - Carbon Load: 9% - End Cap: Yes
pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Particle Size: 5 µm - Pore Size: 100 Å - Carbon Load: 2% Phase Length ID Particle Size Part No.
C4 150 mm 4.6 mm 5 µm N9303720
Phase Length ID Particle Size Part No.
C4 250 mm 4.6 mm 5 µm N9303721
Amino 100 mm 2.1 mm 5 µm N9303532
Amino 150 mm 2.1 mm 5 µm N9303533
Brownlee Validated C8
Amino 150 mm 4.6 mm 5 µm N9303534
Retentive, high purity base-deactivated reversed phase packing.
Amino 200 mm 4.6 mm 5 µm N9303535
Amino 250 mm 4.6 mm 5 µm N9303536 pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Pore Size: 80 Å - Carbon Load: 12% - End Cap: Yes
Brownlee Validated Aqueous C18 Phase Length ID Particle Size Part No.
Highly base deactivated. Compatible with highly aqueous C8 100 mm 2.1 mm 5 µm N9303564
mobile phases. C8 100 mm 4.6 mm 5 µm N9303565
pH range: 2.5 to 7.5 - Temperature limit: 80° C - C18 250 mm 2.1 mm 5 µm N9303560
Pore Size: 100 Å - Carbon Load: 5% - End Cap: No C18 250 mm 4.6 mm 5 µm N9303561
www.perkinelmer.com/supplies 25
CONVENTIONAL COLUMNS
A unique stationary phase bonded to a 3µm silica speci cally IBD 30 mm 1.0 mm 5 µm N9303585
designed for carbamate analysis. This column is compatible IBD 30 mm 2.1 mm 5 µm N9303586
with rescence or LC/MS detection. Validated Carbamate IBD 30 mm 4.6 mm 5 µm N9303587
column has much faster analysis, which will signi cantly reduce IBD 50 mm 2.1 mm 5 µm N9303588
solvent usage. IBD 50 mm 4.6 mm 5 µm N9303589
pH range: 2.5 to 7.5 - Temperature limit: 80° C - Pore Size: 100 Å IBD 100 mm 2.1 mm 5 µm N9303579
IBD 100 mm 4.6 mm 5 µm N9303580
Phase Length ID Particle Size Part No.
IBD 150 mm 2.1 mm 5 µm N9303581
Carbamate 50 mm 4.6 mm 3 µm N9303570
IBD 150 mm 4.6 mm 5 µm N9303582
Carbamate 100 mm 4.6 mm 3 µm N9303569
IBD 200 mm 4.6 mm 5 µm N9303583
Carbamate 250 mm 4.6 mm 3 µm N9303571
IBD 250 mm 4.6 mm 5 µm N9303584
Brownlee Validated IBD High purity, highly retentive base-deactivated phase, especially
designed for aromatic analytes.
Unique selectivity and a high level of base-deactivation. Reduces or
eliminates the need for mobile phase additives. pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Pore Size: 100 Å - Carbon Load: 10% - End Cap: Yes
pH range: 2.5 to 7.5 - Temperature limit: 80° C -
Pore Size: 100 Å - Carbon Load: 12% - End Cap: No Phase Length ID Particle Size Part No.
Phenyl 50 mm 1.0 mm 3 µm N9303604
Phase Length ID Particle Size Part No.
Phenyl 100 mm 2.1 mm 3 µm N9303602
IBD 30 mm 4.6 mm 3 µm N9303594
Phenyl 100 mm 4.6 mm 3 µm N9303603
IBD 50 mm 2.1 mm 3 µm N9303595
Phenyl 150 mm 2.1 mm 5 µm N9303605
IBD 50 mm 4.6 mm 3 µm N9303596
Phenyl 150 mm 4.6 mm 5 µm N9303606
IBD 100 mm 2.1 mm 3 µm N9303590
Phenyl 250 mm 4.6 mm 5 µm N9303607
IBD 100 mm 4.6 mm 3 µm N9303591
IBD 150 mm 2.1 mm 3 µm N9303592
IBD 150 mm 4.6 mm 3 µm N9303593
Replacement cap frits 2.0 mm, 2.0 µm N9303717 Organic Acids 10 mm 2.1 mm 5 µm N9303670
Replacement cap frits 4.0 mm, 0.5 µm N9303716 Organic Acids 10 mm 4.0 mm 5 µm N9303671
Replacement cap frits 4.0 mm, 2.0 µm N9303715 PFP Propyl 10 mm 2.1 mm 5 µm N9303672
PFP Propyl 10 mm 4.0 mm 5 µm N9303673
www.perkinelmer.com/supplies 27
BROWNLEE CARTRIDGE COLUMNS
Brownlee Sorbents
PerkinElmer Brownlee™ cartridge columns are offered in a wide
range of sorbent material. Choose the right sorbent for the
analysis and mode of separation being used.
Aquapore® – is a wide-pore, silica-based support suitable for the
separation of large biopolymers.
Spheri-5® – is a small-pore, silica-based solvent for separating
small molecules. Both monofunctional (comb-type) and
polyfunctional (polymerized loop-type) C8 and C18 sorbents
are available.
Polypore® – is a polymer-based (microporous, 10 µm) sorbent for
the analysis of organic acids and sugars.
Validated™ – is a small-pore, silica-based C18 sorbent for small
molecules, speci cally for consistent pharmaceutical assays.
Pecosphere™ – is a small-pore, silica-based sorbent for HPLC
of small molecules. CHOICE™ – is a small-pore, base deactivated silica-based,
Reduced Activity – is a small-pore, base deactivated silica-based, reversed-phase sorbent (C18) developed for LC/MS separations.
reversed-phase sorbent (C18 or C8) developed for HPLC of basic Peco HCODS – is especially suited for reversed-phase separation
analytes and pharmaceuticals. of proteins and peptides.
Brownlee Cartridge Columns
Column Functionality Pore Diameter Å % Carbon End Cap Applications
Aquapore AX-300 (anion exchange) 300 - - Silica-based support for larger anionic compounds
Aquapore OD-300 (C18) 300 10 Yes Silica-based support for larger compounds by reversed-phase
Aquapore RP-300 (C8) 300 5 Yes Same as above, but for slightly more polar compounds
Aquapore BU-300 (C4) 300 3 Yes Same as above, but for even somewhat more polar compounds
Choice C18 100 12 Yes F ation of basic compounds/pharmaceuticals
Choice C8 100 7 Yes F ation of basic compounds/pharmaceuticals
Choice PFPP (P 100 5 Yes F ation of basic drugs, especially for LC/MS
Pecosphere C18, monofunctional 80 11 Yes Reversed-phase column for fast separation of smaller compounds
Pecosphere CR C18 80 11 Yes Same as above, but for more basic compounds
Pecosphere CR C8 80 11 Yes Same as above, but, also, for slightly more polar compounds
Peco HCODS C18, polyfunctional 300 9 No Especially suited for reversed-phase separation of proteins and peptides
Polypore CA (calcium form), Mixed Mode Microporous - - Especially suited for separation of organic acids, as well as sugars
Polypore H (hydrogen form), Mixed Mode Microporous - - Especially suited for separation of sugars, as well as organic acids
Reduced Activity C18 80 12 Yes Reversed-phase sorbent geared for fast separation of basic
compounds/pharmaceuticals
Reduced Activity C8 80 5 Yes Same as above, but for slightly more polar compounds
Spheri-5 RP-18 (monofunctional C18) 80 11 Yes Reversed-phase separation of smaller compounds
Spheri-5 ODS (polyfunctional C18) 80 14 Yes Same as above, but with somewhat different selectivity
Spheri-5 RP-8 (monofunctional C8) 80 6 Yes Reversed-phase separation of more basic smaller compounds
Spheri-5 Phenyl (C5) 80 6 Yes Especially suited for hydrophobic interaction separation of biomolecules,
where the activity of the compound must be preserved
Spheri-5 Amino 80 3 No Normal-phase separation of smaller, relatively more polar compounds
Spheri-5 Cyano 80 4 No Same as above, but with somewhat different selectivity
Spheri-5 Silica 80 - - Same as above, but with different selectivity
Validated C18 100 18 Yes Reversed-phase separations in which very little variation in both
lot-to-lot and column-to-column variability can be tolerated
VeloSep RP-18 (C18) 100 14 Yes Reversed-phase column for high through-put and minimal solvent usage
VeloSep RP-8 (C8) 100 7 Yes Same as above, but for slightly more polar compounds
Features and Be
• Quality – manufactured under ISO-9001 certi d quality
control procedures
• Quick and easy cartridge change w ger-tight design
• Flexible – same reusable holder for 2.1 and 4.6 mm cartridges
Brownlee Columns and Holders
• Economical – less expensive than conventional columns
Brownlee VeloSep®
Brownlee CHOICE™ VeloSep columns are 3.2 mm i.d. cartridges packed with 3 µm
reversed-phase support for high throughput analysis and reduced
The CHOICE™ columns provide the speed and ef ciency
solvent consumption. VeloSep is packed with 3 µm C8 or C18
appropriate for LC/MS. Each column’s separation requirements
sorbents and available in 40 or 100 mm lengths.
vary depending on the system, sample and mass spectrometer.
www.perkinelmer.com/supplies 29
BROWNLEE CARTRIDGE COLUMNS
33 mm x 4.6 mm i.d.4
Scavenger Columns 5 per package
Column Description Part No.
Silica Scavenger 10 µm 02580203
C18 Scavenger Monofunctional, 10 µm, 80A 02580202
www.perkinelmer.com/supplies 31
BROWNLEE CARTRIDGE COLUMNS
NewGuard Columns
NewGuard cartridges are small guard cartridges (15 mm x
3.2 mm i.d.) packed with 5 or 7 µm sorbents. NewGuard
cartridges prolong column life by eliminating particulates,
contaminant’s, and strongly bound sample components.
They act as replaceable, disposable heads of your analytical
columns. There is negligible loss of ef ciency and little effect
on retention or resolution. NewGuards are available in a
convenient 3-pack and can be coupled directly to any MPLC
cartridge with a union (07150018).
Features and Be
• Prolong column life by 2 to 5 times
• Protect your column from particulates and strongly bound
View of the NewGuard holder and a NewGuard 3-pack.
sample components
• Optimized dimensions to prevent loss of resolution
Standards Solutions
• Easy coupling to MPLC cartridges or conventional columns
• Finger-tight seal to 7,000 psi using NewGuard holders Description Part No.
• Can be used for sample preconcentration Test Mix
(connected to sample injection loop) LC Gradient Test Mix N9334010
Universal Test Mix for Reversed-phase (5 mL/pkg) 00890893
15 mm cartridge*, 3.2 mm i.d., 3 per pkg.
Standards
Description Size Shape Part No. HPLC SV Calibration Mix #5/610 PAH 00891542
Amino, Aquapore® Amino 7 µm Spherical 07110098 HPLC 610 Calibration Mix A 00891543
Anion, Aquapore Anion 7 µm Spherical 07110102 HPLC 610 Calibration Mix B 00891544
Cyano, Aquapore Cyano 7 µm Spherical 07110100
Diol, Aquapore Diol 7 µm Spherical 07110105
Phenyl, Aquapore Phenyl 7 µm Spherical 07110096
NewGuard Accessories
RP-2, Aquapore Dimethyl 7 µm Spherical 07110086 Replacement Seals for MPLC and Prep-10 Holders
RP-4, Aquapore Butyl 7 µm Spherical 07110088 Description Part No.
RP-8, Aquapore Octyl 7 µm Spherical 07110090 Prep-10 Inlet Seal
RP-18, Aquapore ODS 7 µm Spherical 07110092 One each 07150012
Silica, Aquapore Silica 7 µm Spherical 07110106 (Prep-10 Seal Replacement Kit Tools Required)
Finger-Tight Holders
MPLC/Peco™ Holders
The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only er-tightening. The high-pressure seal in
each end assembly actually seals tighter as pressure increases. No wrenches are required, and there is no need to disconnect any tubing
to your LC system when changing a cartridge. Each MPLC cartridge can be directly coupled to another using a union.
NewGuard® Holder Holds a single NewGuard cartridge or a single 20 mm CHOICE™ cartridge. 07150001
130 mm MPLC System Holder Holder for a 30 and 100 mm coupled cartridge. 07150032
www.perkinelmer.com/supplies 33
SAMPLE LOOPS AND TUBING
Stainless Steel Sample Loops Sample loops are made from PEEK tubing and ttings. PEEK
(poly-ether-ether-ketone) is a mechanically-strong, chemically-inert
For Flexar FX UHPLC Autosampler polymer, ideal for HPLC applications where metal surfaces may
(up to 18,000 psi operation) interact with the mobile phase or sample component. Each
Stainless Steel loops required for use with FX-10 or FX-15 sample loop is supplied with two PEEK hex-head nuts and
systems operating above 6,200 psi. ferrules. These ttings grip the tubing in two locations for a
more reliable connection.
High Pressure Stainless Steel Sample Loops
Description Size Part No.
Description Size Part No.
PEEK Sample Loop 20 µL N9306035
Sample Loop, SS 2 µL N2936071
PEEK Sample Loop 50 µL N9306036
Sample Loop, SS 5 µL N2936056
PEEK Sample Loop 200 µL N9306038
Sample Loop, SS 10 µL N2936057
Internal Loop (PEEK and Ceramic) 2 µL N9306022
Sample Loop, SS 20 µL N2936058
Sample Loop, SS 50 µL N2936059
Tubing Accessories
Sample Loop, SS 100 µL N2936060
Sample Loop, SS 200 µL N2936061 Clean-Cut™ tubing tool is designed
Sample Loop, SS 500 µL N2936062
to cut Te ®
, Tefzel® and polymers in
general but, in particular, PEEK tubing. A unique safety locking
Sample Loop, SS 1 mL N2936063
mechanism secures the blade when not in use.
Sample Loop, SS 2 mL N2936064
Sample Loop, SS 5 mL N2936065 Description Part No.
Clean-Cut Tubing Cutter ED020015
Stainless Steel Sample Loops Clean-Cut Tubing Replacement Blade ED020016
Model 7125/7010 Model 7725 Model 8125 Cable/Tubing clip (U-Shaped) NX598006
Size Part No. Part No. Part No. Stick-on Tubing Organizer (Gray Plastic) NX598006
10 µL 09904938 N9306024
50 µL 09904940 N9306026 PEEK Tubing
100 µL 09904942 N9306027 41000013
PEEK tubing has the strength required to withstand continuous
200 µL 09904818 N9306028 09904818
use at HPLC pressure without swelling or bursting.
5 mL N9306032
Use PEEK with virtually any organic or inorganic liquid. PEEK
tubing is not affected by halide salts, high-strength buffers or
PEEK Sample Loops For Series 200/225 and other aggressive mobile phases that degrade stainless steel.
Flexar LC Autosamplers (up to 6,200 psi operation)
Description Length Part No.
These loops are compatible with all standard Flexar autosamplers 1
⁄16 in O.D. x 0.007 in I.D. 5 ft N9302678
as well as Series 225 autosamplers. PEEK loops cannot be used 1
⁄16 in O.D. x 0.010 in I.D. 5 ft N9302650
above 6,200 psi operation therefore are NOT compatible eith 1
⁄16 in O.D. x 0.004 in I.D. (Black) 50 cm N2916200
standard Flexar autosamplers. Stainless steel loops required for use 1
⁄16 in O.D. x 0.005 in I.D. (Red) 50 cm N2916059
wirh FX-10 or FX-15 UHPLC systems operating above 6,200 psi.
Connector Tubing, Flexar/FX Mixer to N2916211
Description Size Part No. Injector, SS
ONE-PIECE,
High-performance Fingertight® ttings
for the most demanding applications
This PEEK Fingertight® tting is the toughest with regard to chemical
EASY-TO-USE
resistance and pressure. This high-performance Fingertight® tting is
recommended for the most demanding applications and will resist
pressures up to 6,000 psi (400 bar). Made from a single piece of
PEEK, the size permits tightening without tools.
www.perkinelmer.com/supplies 35
VACUUM DEGASSING KITS
Liquid Chromatography Laboratory Bottle Kits High pressure FX-15 Piston Seal Kit N2911221
Standard Piston Seal Replacement Kit N2910383
Contents Part No. for Series 200 and Flexar Pump
1x5 Liter Bottle with Cap and T 2 Meters N2601610 Includes: Four Seals, Backup Rings, and O-rings
PTFE 1⁄8" Tubing and 1x10 µm SS Solvent Frit Insertion Tool N2601503
1x2 Liter Bottle with Cap and T N2601611 Micropump Piston Seal Replacement Kit N2910384
PTFE 1⁄8" Tubing and 1x10 µm SS Solvent Frit for Series 275 and FX-10 pump
1x1 Liter Bottle with Cap and T N2601612 Piston Wash Bottle Kit for FX-15 N2601616
PTFE 1⁄8" Tubing and 1x10 µm SS Solvent Frit
Pulse Compensator Repair Kit N2600313
1x0.5 Liter Bottle with Cap and T N2601613 Includes: Diaphragm, Elastomer Plug, and Seal
PTFE 1⁄16" Tubing and 1x40 µm SS Solvent Frit
Seal Removal Tool N2601295
1 Cap with T 1
⁄8" Tubing and N2601614
1x10 µm SS Solvent Frit Series 200 Bio LC Pump Maintenance Kit N2910346
Includes: Fuses, Seals, O-rings, and Seal Tools
1 Cap with T 1
⁄16" Tubing and N2601615
1x40 µm SS Solvent Frit Series 200 Pump Maintenance Kit N2910345
Includes: Fuses, Seals, O-rings, and Seal Tools
1x0.5 Liter Bottle with Cap and Dual T N2601616
Insert 2 pcs of 2 Meter PTFE 1⁄8" Tubing (Piston
Wash Function) Replacement Vacuum Degasser Bottles
1 Cap with Dual T N2601617
Description Part No.
PTFE 1⁄8" Tubing and 1x10 µm SS Solvent Frit (Piston
Wash Function) 1 L Glass Bottle N2600497
2 L Glass Bottle N2600498
Solvent Filters/Scavengers
Analytical Static Mixers (up to 6,200 psi)
In-Line Solvent Filter System 09903606
In-Line Solvent Filter Replacement Kit 02540311 Description Size Part No.
In-Line Solvent Filter System, Titanium N2600259 Binary T Mixer 10 µL N2911170
Replacement 2 µm Titanium Filter Element N2601477 Binary T Mixer 25 µL N2911171
Replacement Seal for In-Line Solvent Filter N2601262 In-Line Mixer Assembly 150 µL N2911173
3 cm Scavenger Cartridge Holder 02580178 In-Line Mixer Assembly 500 µL N2911172
02580202 Binary T Mixer Cartridge 10 µL N2911174
LC System Accessories Binary T Mixer Cartridge 25 µL N2911175
Solvent waste cup N2916019 Binary T Mixer Cartridge 50 µL N2911176
Drain Cup N2916085 Binary T Mixer Cartridge 150 µL N2911177
90° Elbow Adapter, ⁄4" ID HDPP
1
09220102 Binary T Mixer Cartridge 250 µL N2911178
Tubing Clip (U-shaped, Polypropylene) NX598006
Polypro Elbow Barbs 09220102 Dynamic Mixer
Large ID (11 mm) Silicone Tubing (5 ft) N2916016 Used to facilitate complete mobile phase blending, resulting in
Manual Injector Bracket (Magnetic Clip-on) N2931275 improved retention performance. The mixer will most typically be
used as part of a Micro pump package — where high-pressure
blending of 2 pump outputs is required. Three different volume
mixing heads (75, 200 and 400 µL) are available.
Static Mixers
Kit includes: Mixer Accessory, Stainless Steel “Tee” Fitting (N2911127), U.S.
Static mixers are used to facilitate complete mobile phase style AC Line Cord and 0.1 A Type T Fuse.
blending, resulting in improved retention performance. The mixer
Description Part No.
will most typically be used where high-pressure blending of two
Dynamic Mixer Accessory (100–240 V) N2910520
pump outputs is required. Mixers incorporate a highly ef cient
cross w shearing mechanism which produces vortex sheer
Mixing Heads
mixing over a wide w range.
Size Part No.
75 µL N2910521
200 µL N2910522
400 µL N2910523
Mixers
Mixing Head
www.perkinelmer.com/supplies 37
INJECTION VALVES AND ROTOR SEALS
NEW
For both the Rheodyne and Flom valves, rotor seals should be Ideal for use in an LC/MS system, the model 8125 is designed for
periodically replaced every 6 months to a year and are available 1 and 2 mm microbore columns and can also be used with
in PEEK. For the Rheodyne valve, they are also available in Vespel.
PEEK is more inert towards amines and other basic biomolecules/ produce low dispersion, maintaining the high mass sensitivity
pharmaceuticals, exhibiting less sample carryover. However, Vespel inherent in micro columns.
is somewhat more resilient than PEEK, providing somewhat better Description Product No.
wear life. 8125 Low-Dispersion Stainless Steel Injection Valve N9306021
INTERCHANGEABLE
FOR YOUR SAMPLE
Bio Conversion Kits Flexar UV/Vis, Series 200/785A UV/Vis,
There are two kits available; one that contains all of the parts Flexar PDA and Series 200 EP
necessary to convert the Series 200 pump and Series 200
These wcells provide the highest detection limits possible for
autosampler for Bio applications. The other contains all of
your sample. The 6 mm pathlength wcell has been optimized
the parts necessary to convert only the Series 200 Pump
for lower-dispersion LC analysis and is the perfect choice when
for Bio applications.
using narrowbore, 2.1 mm or microbore, 1 mm columns (see
Description Part No. Figure 1). The 3 mm pathlength is the choice for semiprep LC to
S200 Pump and S200 Autosampler Conversion Kit N2910035 avoid detector saturation at high-solute concentrations.
S200 Pump Conversion Kit N2910036
UV/Vis, PDA, FL and LC-135/235 FLOWCELLS
The detector backpressure regulator is a device that is attached to Flowcells for Flexar and Series 200EP PDA Detectors
the outlet of the detector to prevent outgassing in the wcell, Flowcell 10 mm x 15 µL N2920126
eliminating variations to the detector baseline. Flowcell Assembly 10 mm x 15 µL N2920160
Flowcells for Series 200 PDA Detectors
Description Material Part No.
Flowcell 10 mm x 12 µL N2922107
40 psi inline backpressure regulator N2925090
Flowcell 4.5 mm x 5 µL N2922030
2 – 5K psi variable N2925091
backpressure regulator FL 3 µL Flowcell w/ Assembly N2922211
Backpressure Regulator Stainless 09907126 Flowcells for LC-135/235 PDA Detectors
Adjustable from 15 – 59 psi Steel Flowcell Assembly 10 mm x 8 µL N2350211
(w/ heat exchanger)
Flowcell 10 mm x 8 µL N2350162
www.perkinelmer.com/supplies 39
HPLC AND UHPLC DETECTOR LAMPS
FOR OUTSTANDING
PERFORMANCE
Series 200/200 EP
Photo Diode Array Detector Lamp
• Return on investment in 6 months to 2 years N2-35 Mid Flow Nitrogen Generator N9306211
without Air Compressor
• Minimal maintenance required
Product Specification
Applications Purity: 95.0 – 99.5%
• LC/MS Atmospheric Dewpoint -58 °F (-50 °C)
• Solvent Evaporation Particles >0.01 μm: None
• Analytical instruments requiring nitrogen Suspended liquids: None
www.perkinelmer.com/supplies 41