Pararrayo ERICO
Pararrayo ERICO
nVent is a trusted world leader for providing high-quality nVent offers three versions of the
grounding solutions, lightning protection and surge protection nVent ERICO Interceptor ESE i-Series
technologies. By recognizing the importance of an integrated air terminals:
1
lightning protection strategy, nVent has incorporated several
• SI25i with a triggering advance
major concepts into a Six Point Plan of Protection:
of 25 μs
1. Capture the lightning strike • SI40i with a triggering advance
2. Convey this energy to ground of 40 μs
3. Dissipate energy into the grounding system • SI60i with a triggering advance
2
of 60 μs
4. Bond all ground points together
These early streamer emission air
5. Protect incoming AC power feeders
terminals (ESEAT) are in accordance
6. Protect low voltage data/telecommunications circuits with the 2011 edition of NF C 17-102.
nVent operates in every region of the world and supports the The design requirements, protection
global market with an extensive distribution network, helping level calculations and protection
3
to ensure that nVent products and expertise are available radius are obtained from this
for any project, regardless of size or location. Dedicated standard.
consulting teams assess the requirements of any project and
provide guidance for optimal lightning protection solutions. Due to the internal control circuit,
the Interceptor ESE i-Series enables
An unparalleled level of engineering support and experience the early launching of an upward
is involved in the development of grounding, lightning leader compared to other passive
protection and surge protection products. nVent has components.
developed specialized design software to integrate all aspects
1. Strike tip
affecting system performance, including local conditions,
to help ensure that requirements of relevant standards are 2. Insulator ring
met or exceeded. 3. High voltage control section
nVent’s products are manufactured to ISO 9001:2008
®
SI60i
and are subjected to rigorous field and laboratory testing
and computer modeling during product development.
The products are supported by test reports, technical papers,
literature and installation instructions.
2 | nVent.com/ERICO
Testing and Working Principles
nVent.com/ERICO | 3
Testing and Working Principles
WORKING PRINCIPLES
During thunderstorm conditions when
the lightning down leader is approaching
ground level, an upward leader may be
created by any surface. In the case of a
passive lightning rod, the upward leader
propagates only after a long period of charge
reorganization. In the case of the Interceptor
ESE i-Series, the initiation time of an upward
leader is greatly reduced. The Interceptor ESE
i-Series generates controlled magnitude and
frequency pulses at the tip of the terminal
during high static fields prior to a lightning
discharge. This enables the creation of
an upward leader from the terminal that
propagates toward the downward leader
coming from the thundercloud.
FEATURES
• Designed and tested to NF C 17-102 and
similar standards
• 304 stainless steel design suitable for most
environments
• Available in three models to suit specific site
requirements
• Suitable for use with a variety of downconductor
SI60i
systems, including tape, cable, smooth-weave,
Isolated Downconductor (ISODC) and
nVent ERICO Ericore conductor
SI40i
SI25i
4 | nVent.com/ERICO
Protecting Areas
According to NF C 17-102:2011, the standard protection radius (Rp) of the Interceptor ESE i-Series is linked to ΔT (below), the
protection levels I, II, III or IV (as calculated in EN 62305-2) and the height (h) of the Interceptor ESE i-Series above the structure or
feature to be protected (defined by NF C 17-102 as a minimum 2 m).
Rp
Protection Protection Level I Protection Level II Protection Level III Protection Level IV
Level (99%, D = 20 m) (97%, D = 30 m) (91%, D = 45 m) (84%, D = 60 m)
Model SI25i SI40i SI60i SI25i SI40i SI60i SI25i SI40i SI60i SI25i SI40i SI60i
∆T (µs) 25 40 60 25 40 60 25 40 60 25 40 60
h (m) Rp (m) Protection Radius
2 17 23 32 19 26 34 23 30 40 26 34 44
3 25 35 48 26 39 52 34 45 59 39 50 65
4 34 46 64 39 52 68 46 60 78 52 67 87
5 42 58 79 49 65 86 57 75 97 65 83 107
6 43 59 79 49 66 86 58 76 97 66 84 107
7 44 59 79 50 66 87 59 76 98 67 85 108
8 44 59 79 51 67 87 60 77 99 68 86 108
nVent.com/ERICO | 5
Design
The aim of lightning protection design is to mitigate all the nVent’s series of SIM and ER
factors that can impact the lightning risk. The requirements of masts and support hardware
EN62305-2 provide guidance on calculation and selection of provide a wide range of mounting
protection levels for each specific application. options for both cantilevered and
guyed installations.
nVent’s unique computer-aided program provides design
support for a variety of design techniques and standards,
including NF C 17-102. Based on individual site parameters,
such as structure dimensions, terminal type and protection
requirements, each Lightning Protection System Design (LPSD)
is customized for the project. It provides elevation, 3-D and plan
views enabling terminal location, downconductor routing and
grounding system requirements to be optimized for your facility.
LPSD Design
Software
SYSTEM REQUIREMENTS:
The design and installation of the terminals should be completed Each downconductor requires a test clamp and dedicated earth
in compliance with the requirements of the French Standard system of 10 ohms or less. The lightning protection ground
NF C 17-102. In addition to terminal placement requirements, the should be connected to the main building ground and any nearby
standard requires a minimum of two paths to ground per terminal buried metallic items. The NF C 17-102 and similar ESE standards
for non-isolated conductor systems. A downconductor cross- requirements for inspection and testing range from each year to
sectional area of ≥50 mm2 is specified. The downconductors every four years dependent upon location and protection level
are to be secured at three points per meter with equipotential selected. Refer to your nVent representative or the System 1000
bonding made to nearby metallic items. installation manual for additional information.
6 | nVent.com/ERICO
Importance of Grounding
The transient nature of lightning with its associated fast
rise times and large magnitude currents mean that special
consideration needs to be given to grounding for lightning
protection to be effective. A poorly grounded system increases
the likelihood of the strike flashing over to the structure and/or
finding a non-preferred path within the structure. Many factors,
such as soil resistivity variations, installation accessibility, layout
and existing physical features are all site-specific and tend to
affect decisions on grounding methods employed. The primary
requirements of a direct strike grounding system are to:
• Efficiently dissipate lightning energy into the ground
• Help protect equipment and personnel
• Provide good corrosion resistance/long life
Test Clamp
nVent.com/ERICO | 7
Ordering Information
Air Terminals
8 | nVent.com/ERICO
Ordering Information for Europe and Asia
Masts and Bases Accessories
Adapters
Waterproof Cone
Mast Adapter WPC (702230) 0.07 kg
INTCPTMI16AT 0.1 kg
Mast Adapter
INTCPTSIIERICOR 0.1 kg
nVent.com/ERICO | 9
Ordering Information for North America
and South America
Masts and Bases Accessories
Adapters
Adapter
INTCPTSIIER1 0.1 kg
SIi terminal to ER1 mast.
Adapter
INTCPTSIIER2 0.1 kg
SIi terminal to ER2 mast.
10 | nVent.com/ERICO
Other Lightning Protection and Grounding Accessories
PDCUC 711352
WPC 702230
STCS253
SDH-3-GI 107500
LEC-IV 702050
PCF-40-GS 102800
This illustration is not drawn to
scale, nor does it portray an actual
or typical application. It is designed
to illustrate some of the major
components of the nVent ERICO
Lightning Protection System and
their relationship with one another.
nVent.com/ERICO | 11
Our powerful portfolio of brands:
CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
nVent.com/ERICO
WARNING: nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at nVent.com/ERICO and from your
nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property
damage, serious bodily injury and death and/or void your warranty.
©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specifications without notice.
Erico-CAT-E538B-E484LT14WWEN-EN-1805