Introduction
Manual Instruction
This is <HiOSO EPON Network Management System Operation User’s Manual>, this manual is
applicable to the EPON equipment with the HiOSO Network Management System. This manual is
Conventions
When this manual is introducing the usage of the commands, it might use one or several text format as
Format Description
Refers to command line keyword (remain unchanged part of the command, must
Bold
input accordingly)
| Used to separate several options, indicates that select from two or more options.
[] Indicates that the content in the “[]” is optional during command configuring.
[x|y|…] Indicates that select one or not from two or more options.
Indicates that the user needs to input the IP address, and it is allowed to
<A.B.C.D/M> designate subnet mask with parameter “M”, “M” is referred to the bit of the subnet
mask.
Format Description
[] “[]” indicates windows name, menu name and datasheet, such as “pop up [open]
window”.
/ Multilevel menu is separated with “/”, for example: [system/exit] indicates the [exit]
3
option under [system] menu list.
essential information, and the click the enable button in essential information.
3.Content Introduction
Chapter Content
Chapter 1 Product introduction EPON product interview 、 features and introduction of network
management.
parameter of the network Change the IP address, Alarm address and system information
management card
Chapter 3 EPON network
Install, uninstall and enable the software
management software
4
HIOSO EPON SNMP user manul
Catalogue
Chapter 1 Product Introduction......................................................................................................... 1
1.1 Product Interview.......................................................................................................................................... 1
1.2 Interface and Indicator Light........................................................................................................................1
1.3 Management Card Cable Connection....................................................................................................... 2
Chapter 2 Config the system parameter of the management card............................................. 3
2.1 Config Preparation........................................................................................................................................ 3
2.2 Login Network Management Card Config................................................................................................ 3
2.2.1 Telnet Login Network Management................................................................................................3
2.2.2 Login network management by Console interface...................................................................... 4
2.3 Config the System Parameter of Management Card..............................................................................4
2.3.1 Introduction of Configuration........................................................................................................... 4
2.3.2 Config examples................................................................................................................................ 7
Chapter 3 EPON Network Management Software........................................................................ 8
3.1 Installation...................................................................................................................................................... 8
3.1.1 Server.................................................................................................................................................. 8
3.1.2 Client....................................................................................................................................................8
3.2 Enable EPON network management software........................................................................................ 9
3.3 Close EPON Management Software......................................................................................................... 9
Chapter 4 EPON Network Management Software Config.......................................................... 11
4.1 Configuration Introduction..........................................................................................................................11
4.1.1 Login network management client................................................................................................ 11
4.1.2 Configuration Interface Introduction............................................................................................. 11
4.1.3 Change User Password..................................................................................................................12
4.2 Basic Configurations...................................................................................................................................13
4.2.1 Add device........................................................................................................................................ 13
4.2.2 Two ways to check.......................................................................................................................... 18
4.2.3 Update topology...............................................................................................................................20
4.2.4 Check the Device Rack.................................................................................................................. 21
4.2.5 Description of the Device Icon.......................................................................................................22
4.2.6 Alarm Management......................................................................................................................... 22
4.3 OLT Configuration Management.............................................................................................................. 22
4.3.1 OLT Basic Information Management............................................................................................22
4.3.2 OLT Config........................................................................................................................................ 28
4.3.3 OLT Uplink Port Config................................................................................................................... 29
4.3.4 OLT Bridge Parameter Config....................................................................................................... 29
4.3.5 OLT Senior Management Config.................................................................................................. 30
4.4 ONU Config..................................................................................................................................................30
4.4.1 ONU Link Management.................................................................................................................. 30
4.4.2 ONU Hardware Config....................................................................................................................32
4.4.3 ONU Config...................................................................................................................................... 35
4.4.4 ONU 802.1x Management............................................................................................................. 42
i
HIOSO EPON SNMP user manul
iCoreView is a HIOSO independent R&D EPON Network Management System based on SNMP V2c
protocol, and it’s compatible with SNMP V1. iCoreView adopts powerful management capability; the staff
in control center can monitor, manage and maintain EPON system in different places. iCoreView made
Support several Trap management modes, support Trap Email distribution and Trap short
message notification, help the management staff know the condition of the device and the
Perfect log management, record detailed log information during operation and maintenance,
There is one RJ45 port and one Console port on the Network Management card, RJ45 port connects with
the PC network port, Console port connects with the PC Console port by serial line:
www.hioso.com
Tel: 0086 755 83128820 Fax: 0086 755 83151488 Email: [email protected]
Add:6th Floor,12th Building,Wangtang Industrial Zone,Xingao Road,Xili,Nanshan District,Shenzhen
1
HIOSO EPON SNMP user manul
The EPON management card should be in the leftmost slot of the chassis (3U), the cable connection is
shown as Figure 1-1, and both two connections in Figure 1-1 are OK.
www.hioso.com
Tel: 0086 755 83128820 Fax: 0086 755 83151488 Email: [email protected]
Add:6th Floor,12th Building,Wangtang Industrial Zone,Xingao Road,Xili,Nanshan District,Shenzhen
2
HIOSO EPON SNMP user manul
Chapter 2 Config the system parameter of the management card
supposed the user has inserted the management card in the right place of the chassis, and has finished
the cable connection. Before the config, the user’s PC has to meet some basic config demand.
1.User PC
For local config, the IP address of the PC and EPON management card must be in the
same subnet; for remote config, the PC and EPON management card must be reachable
through router. The default IP address of EPON management card is: 192.168.0.88, Mask
is: 255.255.255.0
Connect the RJ45 ports of the PC and EPON management card by UTP cable or through
Click “start/run” of the PC, see the dialog box, and input telnet 192.168.0.88 in “open”, shown as Figure
2-1
3
HIOSO EPON SNMP user manul
Click <OK>, see the Telnet login interface, shown as Figure 2-2, input the user name and the password
EPON network management card allows only one user to login in the same time.
No operations would display on the screen when you input the password, just push enter key
It supports config the network management card by HyperTerminal if the card IP address is unknown.
Connect the Console port of the PC with the Console port of the management card with RS232 serial line,
input area code, phone number and other related information for the first login, and then click<OK> to
next step, input name in “Name” tag under [connection description], click “OK”, to [connect to…], click
“OK”, to [properties], click <restore to default>, then select 115200 in “bit per second”, click “OK”, then to
Revision: software version. Chassis: equipment type. SN: equipment serial number.
4
HIOSO EPON SNMP user manul
Access Password defaults to “admin”. Input password, input “enter”, to privileged mode, input “enable”,
Command line supports command complemented function (press “Tab” in keyboard to implement the
function) and Command prompt function (input “?”, it will show the command that can be input)
For example: if entered configure terminal mode, input command prompt “?”, page would shown as
below:
5
HIOSO EPON SNMP user manul
ping: check whether the connection is available from Host PC and agent card
system: system configure menu, making agent card configurationis through this menu.
Agent card configurations are mainly in “system” menu. Input “show system”, check equipment
IP address: agent card IP address(IP address can not be set in 192.168.1.X network segment)
Trap2sink: the address that agent card send to host PC, i.e. host PC address of installation network
management software
Trapsink: the address that alarm message agent card sends to host PC, same as Trap2sink
6
HIOSO EPON SNMP user manul
Example:
EPON(config)#
7
HIOSO EPON SNMP user manul
3.1 Installation
1. There is disk will be sent together with the EPON products. Please decompress the software. The
install path should be English, no Chinese. After decompression, there is below contents in the objective
directory:
programme regmysqlservice.exe, after decompression, users can find this programme under the
directory of MYSQL5, users just need to run one time the MySQL5\regmysqlservice.exe, then the
MYSQL data base is installed successfully. Then EPON software is installed successfully.
3.1.1 Server
EPON management server supports to collect the information of the OLT racks, and centralized supplying
3.1.2 Client
Client end supports to manage the OLT cards and ONUs, detail functions as below:
User management: add, delete and modify users. Set different authorities to different users, so
Agent management: add the agent information of the rack, so to browser the operating
8
HIOSO EPON SNMP user manul
Alarm query: set the agent card TrapLInk pointing to server IP address, all the login server
client can get the current alarm information, and check the history information.
Alarm management: manage history alarm information and use current alarm information to
EPON network software consists of server and client, before using the client; need to enable the server
firstly.
9
HIOSO EPON SNMP user manul
Left click the icon at the right Conner of the PC, choose “Stop Service” , then
you will see the below interface:
Input password “admin”, click “OK”. Left click the icon again, choose “ShutDown this Tool”, then the
software closed.
10
HIOSO EPON SNMP user manul
Users can use EPON SNMP software to manage and maintenance the devices directly; install and
enable the device please refer to the Chapter 3.
Before config any items, please make sure the connection between the PC and the agent is correct, and
configure the agent IP address and alarm address (there is default IP existed) correctly through Telnet or
Console port. There is LED description refer to the connections (check table 1-1).
Enable the software according to 3.2, see as Figure 4-1, there is prompt about input account and
password (there is default account name existed—administrator, password: admin. Click OK, enter the
11
HIOSO EPON SNMP user manul
Enter the configuration page, left click the main menu【System】-->【Change Password】 as Figure 4-3,
to change password.
12
HIOSO EPON SNMP user manul
In the topology browser, or choose a subnet in the topological view, right click the mouse, choose “Add
Device”, see as Figure 4-4. then popup the add device dialog box as Figure 4-5.
Figure 4-5
13
HIOSO EPON SNMP user manul
Node Name: necessary. The name of the node, this name displays in the topological view.
Node Description: optional. Describe the node, not display in the topological view.
Subnet: necessary. The subnet the node located, default is present subnet.
Click the HiOSO icon, There are the manageable devices list supplied by HiOSO, then click the
Figure 4-6
Device type: necessary. The types of the devices, just for display, can’t be revised.
IP Address: necessary. Device IP addresses, default IP is 192.168.0.88, and users can change
14
HIOSO EPON SNMP user manul
Device Name: optional. The device name, which used to recognize the controlled device, could
SNMP Basic: optional. SNMP management properties, includes: version, SNMP port, read and
write community, time out config and retry times, there is default value at initial. When choose
SNMP version V3, “SNMP V3 property” page is available, users can config V3 properties,
including user name, security class, authentication protocol, authentication password, private
Some properties in this page (SNMP version, SNMP port, read community, write community), we
have config default value. User can revise it according to real environment. Users just fill the IP address
is enough to use.
After fill the properties, click “Next”, enter next property editing page, as Figure 4-7.
Figure 4-7
15
HIOSO EPON SNMP user manul
Monitoring Mode: adopt which operation, There are two options: “ICMP Ping” and “SNMP Ping”.
Polling Interval: the interval time the system polling operations to devices, there are several
optionas:“5 seconds”, “15 seconds”, “30 seconds”, “1 minute”, “5 minutes”, “15 minutes”, “30
Use default configuration is enough. If 30 minutes polling interval is too long, users can choose a
short time like 5 seconds, 15 seconds or 30 seconds, the software can get the online and offline status
in time.
After configure, click “Next”, and enter another property editing page, as Figure 4-8.
Figure 4-8
Purpose: necessary. Identify the device is access layer device or integrated layer device;
16
HIOSO EPON SNMP user manul
Figure 4-9
Please don’t revise the property of this page, keep the default ones.
After configuration, click the “Finish” button to implement creating device node operation, if success,
there is prompt “operation is successful, Add another node now?” Choose “yes”, the guide automatically
switches to the first page; choose “No”, the dialog box closed.
Adding a device node in the topological view, if the device properties filled correctly, and the
device is online, the management software will collect the device basic information, and producing
topological structure according to the device. The icon of the device will change from rectangle to round
17
HIOSO EPON SNMP user manul
rectangle in 10 seconds. Expand the left tree topological structure you can see the device
topological situation. If not changed, please check IP of PC and NMS card IP are in the same segment,
After adding devices completed, you can revise the device properties. Right click the device icon, and
Figure 4-10
The configuration property guidecomes up. This guide is the same with the former adding device guide.
Figure 4-11
There are two registered ONUs under an OLT, if there is no ONU connects to the OLT, you can’t see the
topological structure. If there is ONU connected, but no topological structure, check if the ONU register
18
HIOSO EPON SNMP user manul
【oe:ab:70:00:79:40】 is ONU MAC address, 【4/1/1】is ONU index, 【4】represents OLT is at the fourth
slot of the rack, the first【1】represents the first PON port of the OLT, the second【1】means the ONU
2. Right click the icon and choose【Open Subgraph】, check the device topological view
as Figure 4-12.
Figure 4-12
Users can revise the ONU properties (name and description information; After uses adding device, the
management software will automatically produce the device topological structure, there is a default name
and empty description information produces, users can edit it according to the real requirements.). Right
click the ONU icon and choose 【Edit ONU Properties】, as Figure 4-13, then users and edit the properties.
19
HIOSO EPON SNMP user manul
Figure 4-13
synchronization refer to: The status of the managed devices, cards, ports (these called resource) in the
software be synchronized with the real devices status. When receiving TRAP alarm host IP is set as the
server IP address (the way to set the EPON device receiving TRAP alarm host IP, refer to the chapter
2.2.2 example), the server can update the device real-time status according to the TRAP alarm
information from the devices. This reflection costs some time, manual operation supported to implement
Check the Figure 4-14, right click the devices need to configure synchronization , and
choose 【Related Resource】-->【Synchronize】. The system performs this operation costs some time (the
need time depends on the network status and the devices, usually 3 to 8 seconds)
20
HIOSO EPON SNMP user manul
Figure 4-14
Figure 4-15
21
HIOSO EPON SNMP user manul
If there is no mark on the icon like , , , , it resents the devices work normal,
For every type of alarm event, iCoreView system marks them with a level to show it severity. View NNM
provides 5 levels in all, from the most serious to the least serious, they are:
Critical Alarm (Critical): The highest level alarm, which will interrupt the communication. Marked in
red: .
Major Alarm (Major): Service continues while the performance declined considerably and affected the
Minor Alarm (Minor):Alarm event occurs but do not affect the operation of the service. Marked in
yellow:
Warn Alarm (Warn):The service is operating in order. Only an ordinary problem occurred. Marked in
blue:
Unknown Alarm (Unknown): Alarm events that can not be recognized. Marked in light grey.
22
HIOSO EPON SNMP user manul
Right click the device icon and choose【OLT Config】-->【Basic Manipulation Classic
Info】-->【Classic Info】,then popup the OLT SNMP config interface, as Figure 4-16.
Figure 4-16
Left EPON configuration page is a tree function list, below the list are the devices it support, right side is a
configuration panel to display the device information and the configuration options.
Example:
Choose 【OLT Config】-->【Bridge】-->【Bridge Parameter】, right side will display the parameter as Figure
4-15. If there is no information for【Bridge Parameter】, that means it didn’t point to the OLT in the left
Figure 4-17
Click the 【Bridge Parameter】 again, the right list will display the OLT bridge parameters, as Figure
4-18.To revise the bridge parameter, needs to click the row firstly, then click【Modify】, revise the
parameters in the popup dialog box, after revise, click apply. As Figure 4-19.
23
HIOSO EPON SNMP user manul
Figure 4-18
24
HIOSO EPON SNMP user manul
Figure 4-19
25
HIOSO EPON SNMP user manul
【Slot Info】
Restore OLT to factory settings; when OLT can’t communicate to all the ONUs, try this operation;
Reboot OLT;
Note: After restore OLT to factory settings, need to reboot OLT, then operation effects.
【OLT Info】
Set the registration mode to ONU; The authentication mode includes: accession, MAC and sn, default
one is accession. There are three operations under the three modes: Undefined, Allow and Deny, these
Accession: under this mode, ONU can register normally and display in the topological view. Choose Deny
operation, ONU can’t communicates with OLT; choose Undefined or Allow, ONU can communicate with
OLT; default is Undefined, when new ONU access, it can communicate with OLT.
Mac: under this mode, ONU can register normally and display in the topological view. Choose Undefined
or Allow, ONU can’t communicate with OLT; default is Undefined, when new ONU access, it can ‘t
【ONU Operation】
Set ONU access mode, there are three modes: Undefined, Allow and Deny, as Figure 4-20. Users can
Figure 4-20
26
HIOSO EPON SNMP user manul
Figure 4-21
Right click ONU, choose 【Deactive ONU】, the access mode changes to Deny, communication between
ONU and OLT break off. If choose【Active ONU】, ONU access mode changes to Allow, ONU
Figure 4-22
27
HIOSO EPON SNMP user manul
as Table 4-2.
Figure 4-23
【Network Params】 Revise the VLAN Ethernet type passing through OLT (suggest use the
default value 8100), add tags to uplink and downlink (suggest not config
this)
【Bandwidth】 Config the maximum upstream and downstream bandwidth of OLT PON
Table 4-2
Sensitive: distribute a fixed bandwidth to the link, let the link data queue empty
Tolerant: only when the link data queue is empty, the bandwidth allocated to the
【Mode】
link is virtual value (recommend this mode)
TDM: time division multiplexing, supports to set the size of round time slice
Table 4-3
28
HIOSO EPON SNMP user manul
Figure 4-24
Duplex Mode: set port working mode to full duplex or half duplex
Port Management: close or open the port, close the port, this port not work
Note: to config Port speed or Duplex Mode, must Disabled Port Adaptive Management firstly.
29
HIOSO EPON SNMP user manul
Figure 4-25
【Bridge Parameter】
Downstream Frame ResetAging: Reset aging to downstream frame, this configuration effects to
MAC Learning Overwrite: overwrite the entries in the MAC address table
Allow VLAN Tagged Frames on Simple Bridge: allow data frame with VLAN transmitting in
Simple Bridged link, default config is not enabled; to config VLAN, need to enable this function
first.
【Dynamic MAC】 Check the learned Dynamic MAC from OLT link
Table 4-4
HA7200 series ONU includes: HA7200 one port 100M ONU, HA7200G one port Gigabit ONU, HA7200D
two ports with 100M and 1000M ONU, HA7204 four 100M ports ONU, HA7208 eight 100M ports ONU,
and HA7201TW ONU with CATV port. In the management system, there are two ports for HA7200G
ONU and HA7200 ONU. HA7200G port correspond to the port index 1, port 2 is not used; HA7200 port
correspond to port index 2, port 1 is not used; HA7200D GE port correspond to port index 1, FE port
【Link Bandwidth】.
30
HIOSO EPON SNMP user manul
Figure 4-26
Figure 4-27
HA7200, HA7200G and HA200D each one has 2 links. HA7200 corresponding link is bigger Index link of
the 2 links, smaller Index link is unavail. HA7200G corresponding link is smaller Index link of the 2 links,
bigger Index link is unavail. HA7200D GE port corresponding link is smaller Index link, FE port
corresponding link is bigger Index link. HA7204 and HA7208 each has 1 link. As HA7200D has 2 usable
links, GE port bandwidth and FE bandwidth could be separately configured. Other type ONU link
bandwidth is total bandwidth of all ports. Please check the table 4-5.
31
HIOSO EPON SNMP user manul
needed under ONU users, make the bandwidth value between Max. and Min.
bandwidth. At this time, no need to set the same value of Max. bandwidth and
Min. bandwidth.
【Mode】
Tolerant: distribute a fixed bandwidth to the link, even if the users under ONU
don’t take full advantage of bandwidth that are distributed. At this time, Max.
TDM: time division multiplexing, supports to set the size of round time slice
Figure 4-5
Figure 4-26
32
HIOSO EPON SNMP user manul
【Device Information】 Reset ONU to factory settings, reboot, set ONU access mode
【MAC Entries】 Check ONU port learning MAC address, and clear the learned MAC
address
【Ethernet Info】 Revise the VLAN Ethernet type passing ONU (recommend to use the
default config 8100), add tag to upstream and downstream (not suggest
to config)
【Bridge Config】 Only HA7204 and HA7208 ONU support this function. Config THE local
Table 4-5
Figure 4-27
ONU Learn MAC Entries Limit: limit the MAC address number of devices connected to the ONU,
33
HIOSO EPON SNMP user manul
Flood Frame With Unknown MAC: choose YES, expand the unknown data frame broadcast of
destination MAC to all the ports; choose NO, discard the unknown data frame of destination
MAC.
Locale Switch: config local switch function of multi-port ONUs, choose Enable, each port is not
Figure 4-30
Duplex Mode: set port working mode full duplex or half duplex
Port Management: close or open the port, when close, the port can’t work
Note: to config Port speed and Duplex Mode, must Disabled Port Adaptive Management.
34
HIOSO EPON SNMP user manul
Figure 4-31
Auto Learn MAC Entries Limit: maximum 64, if not limit, config it to 0.
Age: config the MAC aging time, maximum 32768; minimum 0, means not aging.
Forwar Mode: port data packets forward mode, there is 802.1d Forwarding and MAC Access
Control two modes. 802.1d Forwarding actions includes: learn MAC, unicast the known MAC
data frame, flood unknown MAC frame; different with 802.1d Forwarding, under MAC Access
Control mode, only after ONU learned the source MAC of upstream data packet, it will forward
this data packet, this character also called Dropped Unit Learned.
Min Guaranteed MAC Learning Limit: config the minimum entries of MAC learning
Figure 4-32
35
HIOSO EPON SNMP user manul
Table 4-7
【Port VLAN】
Transparent, Tag and Translated mode, details as Table 4-8, 4-9, 4-10.
Upstream With VLAN VID No change to Ethernet packet, reserve the VLAN TAG, forward
Downstream With VLAN VID No change to Ethernet packet, reserve the VLAN TAG, forward
Table 4-7 Treatment way to the data packet under Transparent mode
Downstream With VLAN VID Forward to the corresponding port according to the VID
And divest the VID, if the VID is unequal to the configured ID,
Table 4-8 Treatment way to the data packet under Tag mode
Upstream With VLAN VID If the original VID is the same with forward VID (in tag), divest
this VID, add new tag (Translated Tag) and forward; if different,
discard
36
HIOSO EPON SNMP user manul
Downstream With VLAN VID If the original VID is the same with forward VID (in tag), divest the
VID, add new tag (In Tag) and forward; if different, discard
Table 4-9 Treatment way to the data packet under Translated mode
Example: here need to add VLAN VID to the upstream data entering ONU port, and divest the
Choose ONU Port Type as TAG, input 8100 in the TPID column (TPID is Ethernet type, common is 8100),
input the VID 100 in the VLAN Tag column, as Figure 4-33.
Figure 4-33
Example: upstream, transfer data packet with VLAN VID 20 to VID 30; downstream, transfer the data
Choose ONU Port Type as Translated, input Choose ONU Port Type as TAG, input 8100 in the TPID
column (TPID is Ethernet type, common is 8100), transfer the VID 20 to VID 30, input arbitrary value in
the VLAN Tag column, then ONU will add this VID to the packet with VID, as Figure 4-32
37
HIOSO EPON SNMP user manul
Figure 4--32
Note: VLAN mode can’t switch directly between TAG mode and Translated mode, must config VLAN
mode to Transparent mode and then config new mode; under same modes, to change VID, also need to
config VLAN mode to Transparent, then config new mode, reconfigure VID, or the config is not
successful.
To the ONU HA7200 and HA7200D 100M port (port index is 2), TAG mode is not available, and
Example:
Here need to add VLAN ID to upstream data, and divest downstream corresponding VLAN VID, VID is
100. Choose Translated mode (it should choose TAG mode, tag mode is not available to index 2 port,
Translated mode can implement the same function) Configure as Table 4-35.
38
HIOSO EPON SNMP user manul
Table 4-35
ONU will add VID 100 tag to the data packet without VID, and discard the data packet with VID.
39
HIOSO EPON SNMP user manul
Figure 4-36
ONU supports RSTP (Rapid Spanning Tree Protocol)function. It is simple to config RSTP function.
Under default mode, choose Enable in the Mode options under config panel.
Priority: the size of the priority decides if this network bridge can be taken as root bridge; The
small one can be chosen as root, if all the priority adopts the same value in the whole switch
network, the bridge with smallest MAC can be chosen as root. Under RSTP mode, to config the
network bridge priority will cause the STP recount. Range is 0-65535, default 32768.
Maximum Age: config the aging time. If this value is too small, the spanning tree counts
frequently, this will covers much resource; if this value is too large, it will not find the link faults
40
HIOSO EPON SNMP user manul
timely. According to the real network condition, we suggest to adopt the default value, range
Hello Time: internal time to send config information. If too small, the network bridge will send
the information frequently, cause high load to the network and CPU; too large, network bridge
will take link packet loss as link fault, cause the spanning tree recount. Suggest to use the
Forward Delay: the status forward mechanism spanning tree adopts. RSTP defines three port
statuses: Discarding, Learning and Forwarding. Forward Delay occurs under Discarding and
Learning status. If this value too small, it will lead to temporary redundant path; if too large,
network will can’t connect in long time. Suggest to use default value, range is 4—30s, default is
15s.
The three time parameters of root bridge Hello Time, Forward Delay and Max Age should apply
Port Priority: port priority is an important matter to choose root port. Under same condition,
small value will be the switch root port. If all the Ethernet port adopts same priority parameter,
the range of the priority depends on the port index. Change priority will lead to the spanning tree
Path Cost: related to link speed, the high the port link speed, the low to configure this parameter,
【RSTP State】
Enable RSTP, the whole spanning tree status can check in the【State】table, as Figure 4-37.
41
HIOSO EPON SNMP user manul
Figure 4-37
Multicast Status
A. The menu “Onu Mcast Strip” is to configure the multicast of ONU ports and the related VID
Unstrip/Strip operation. All the multicast from OLT to ONU has the VID, users need to add the VID to the
ONU port, and each port can choose VID according to the needs. After adding VID, ONU port can
receiver multicast strip, and then choose to Unstrip/Strip the VID of this multicast strip; eg, STB doesn’t
support the function of Strip VID, if you want ONU to receive the multicast strip, need to strip the VID for
the STB.
The menu “Onu Mcast Strip” includes two options: “Onu Mcast Strip” and “Multi VLAN”.
42
HIOSO EPON SNMP user manul
OLT Index:
OLT Index is refer to the card type OLT in the rack, this can’t be changed. The 3U rack supports total
8pcsOLT cards (HA7100 or HA7102), The OLT index related to the position of the OLT in the rack, (from
left to right), it is 1, 2, 3, 4, 5, 6, 7, 8.
PON Index: HA7100 OLT card has one PON port, the PON Index is 1; HA7102 OLT card has two
Port Index: refer to ONU ports. HA7204 ONU has 4 10/100M ports, the index is related to 1,2,3,4;
HA7208 ONU has 8 10/100M ports, the index is related to 1,2,3,4,5,6,7,8; HA7200G port index is 1;
HA7200 port index is 2; for HA7200D ONU, 10/100M port index is 2, GE port index is 1;
Multicast VLAN: as all the multicast strip from OLT to ONU has VLAN tag, need to configure the port
VLAN VID to be the same with the multicast strip VID, then the multicast strip can be transferred.
Option: operation refer to the multicast strip ONU received, includes: Unstrip” and “Strip”; “Unstrip”
means keep VID and transfer, “Strip” means discard VID and transfer..
Note: “Multicast VLAN” relates to the “User VLAN” in OLT multicast transfer items.
Choose the port, right click the mouse, and choose “Modify”
43
HIOSO EPON SNMP user manul
See as below:
Choose the port you want to configure, right click the mouse, choose “Modify”:
44
HIOSO EPON SNMP user manul
B The menu “Multicast Status” is to descrip the multicast strip information ONU transfer
OLT Index:
OLT Index is refer to the card type OLT in the rack, this can’t be changed. The 3U rack supports total
8pcsOLT cards (HA7100 or HA7102), The OLT index related to the position of the OLT in the rack, (from
left to right),it is 1, 2, 3, 4, 5, 6, 7, 8.
“Multicast Group Information”: information of the transferred multicast groups, support to check the
multicast IP addrss.
OLT Index:
PON Index:
ONU Index
45
HIOSO EPON SNMP user manul
Port Index
46