0% found this document useful (0 votes)
93 views

Substation S07

This document provides details on typical concrete slab reinforcement, including bar sizes and spacing. It includes a schedule of 8 slab labels (S-01 to S-08) specifying the slab thickness, bar diameter, and bar arrangement along the short and long spans. Reinforcement includes top and bottom bars that are either discontinuous or continuous. All dimensions are in millimeters.

Uploaded by

sam nacion
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views

Substation S07

This document provides details on typical concrete slab reinforcement, including bar sizes and spacing. It includes a schedule of 8 slab labels (S-01 to S-08) specifying the slab thickness, bar diameter, and bar arrangement along the short and long spans. Reinforcement includes top and bottom bars that are either discontinuous or continuous. All dimensions are in millimeters.

Uploaded by

sam nacion
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TYPICAL CONCRETE SLAB

DETAILS
ALONG SHORT SPAN ALONG LONG SPAN
TOP BAR BOTTOM BAR TOP BAR BOTTOM BAR
SLAB THK, t
Ø DISCONTINUOUS CONTINUOUS DISCONTINUOUS CONTINUOUS DISCONTINUOUS CONTINUOUS DISCONTINUOUS CONTINUOUS REMARKS
LABEL (mm) BAR (mm) BAR (mm) BAR (mm) BAR (mm) BAR (mm) BAR (mm) BAR (mm) BAR (mm)
S-01 230 12 190 80 190 80 190 190 190 190 2W
S-02 230 12 190 160 190 160 190 190 190 190 2W
S-03 230 12 190 150 190 150 190 190 190 190 2W
S-04 230 12 190 120 190 120 190 190 190 190 2W
S-05 230 12 270 120 270 120 270 120 270 120 1W
S-06 230 12 270 130 270 130 270 130 270 130 1W
S-07 230 12 270 250 270 250 270 250 270 250 1W
S-08 230 12 270 270 270 270 270 270 270 270 1W
1 SLAB SCHEDULE
S-07 SCALE: NTS
1 SLAB SCHEDULE
S-07 SCALE: NTS
PREPARED BY: NOTES: SHEET SHEET NO.
1). ALL DIMENSIONS ARE IN MILLIMETERS CONTENT:
2). CONCRETE STRENGTH USED (Fc') = 28 Mpa (FOR NON-PRECAST ELEMENTS)
Ronald C. Balbuena, CEng MICE M.ASCE M.IABSE
STEEL STRENGTH USED: Fy = 414 Mpa; Fys = 276 Mpa
3). PROVIDE LEAN CONCRETE WITH 75MM THK. AT MONTALBAN SUBSTATION PREMIUM MEGASTRUCTURES INC. DATE: SCALE:
CHARTERED STRUCTURAL ENGINEER Fc'= 10.5 Mpa OR 1500 Psi OWN ER
4). ALL DIMENSIONS SHALL BE VERIFIED AT SITE CADD BY: REVISION:
PRC NO.: 0113662 DESIGNED BY: DATE: DESCRIPTION
TIN NO.: 287-671-321
PTR NO. 0743752: IAPOA NO.:
LOCATION : MONTALBAN, BULACAN ADDRESS: 1423 The Mondrian Building. P. Ocampo St., Brgy. San Antonio Village, Makati City CHECKED BY: