0% found this document useful (0 votes)
262 views51 pages

Introducing Sepam - R1

The document introduces Sepam protection relays, including their solutions, modularity, performance, and simplicity. It discusses the different Sepam series, their features and applications.

Uploaded by

Anggara Kusuma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
262 views51 pages

Introducing Sepam - R1

The document introduces Sepam protection relays, including their solutions, modularity, performance, and simplicity. It discusses the different Sepam series, their features and applications.

Uploaded by

Anggara Kusuma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 51

Introducing Sepam Protection Relay

PT. Schneider Indonesia


Services Learning & Development

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 1


Sepam protection relays
a range of solutions for all
applications

Sepam series 80
Intelligent solutions
Sepam series 60 for custom applications

Sepam series 40
High-performing solutions
for demanding applications
Sepam series 20
Simple solutions
Sepam series 10
for standard applications
Basic solutions
for simple applications

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 2


Sepam protection relays
a range of solutions for all applications

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 3


Sepam Protection Relay
For your peace of mind
I. Solutions

II. Modularity

III. Performance

IV. Simplicity

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 4


Solutions
Sepam selection guide
Sensors Specific Sub- Trans- Motor Gene- Busbar Capa-
protection station former rator citor
Sepam series 20 3I + I0 S20 T20 M20

10 I / 8 O 50BF
S23 T23
1 comm. port
3V + V0 B21

81R B22

Sepam series 40 3I + I0 S40 T40 G40


3V
10 I / 8 O 67N S41 M41
1 comm. port
Logic equations 67N
S42 T42
67
Sepam series 80 3I + 2xI0 S80 B80
3V + V0
42 I / 23 O 67N S81 T81 M81
2 comm. ports
Logic equations 67N
S82 T82 G82
Logipam 67
81R S84

2x3I + 2xI0 87T T87 M88 G88


3V + V0
87M M87 G87
3I + 2xI0
B83
2x3V + V0
3I + I0
51C C86
4 Ides
3V + V0

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 5


Sepam series 60 selection guide
Specific Sub- Trans- Motor Gene- Busbar Capa-
Sensors protection station former rator citor

Sepam series 60 3I + I0 Basic protection


3V function :
28 I / 16 O 50 / 51
S60 G60 C60
50N / 51N
2 comm. ports 50BF
1 remote module 46
connection port

Logic equations Basic + T60


64REF

Basic +
M61
67N

Basic +
67N S62 T62 G62
67

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 6


Solutions

Sepam series 20

● Current or voltatge metering according to the application

● 10 logic inputs / 8 relay outputs

● 1 communication port

● 8 temperature sensor inputs

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 7


Solutions

Sepam series 40
● Current and voltage metering for all applications:
● all measurements available
● directional protection functions

● 10 logic inputs / 8 relay outputs

● logic equation editor

● 1 communication port

● 16 temperature sensor inputs

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 8


Sepam Protection Relay
For your peace of mind
I. Solutions

II. Modularity

III. Performance

IV. Simplicity

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 9


Modularity
Architecture modulaire
Sepam Functional enhancement
by optional modules

 To specifically fit your needs


 To evolve in step with your installation

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 10


Modularity
Modular architecture
Sepam series 20 / series 40
Sepam base unit

● User Machine Interface


integrated in front panel
or
● Remote User Machine
Interface
(DSM303)

For installation
in the most convenient
place for the user

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 11


Modularity
Modular architecture
Sepam series 20 / series 40
Sepam base unit
● With integrated advanced User Machine
Interface

 With remote advanced User Machine Interface


(DSM303)

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 12


Modularity
Modular architecture
Sepam series 20 / series 40
Additional
inputs / output modules

● 4 relay outputs on the


Sepam base unit
● extended by adding
one module with
● 10 logic inputs
- 24 - 250 V DC (MES114)
- 110 V AC / DC
(MES114E)
- 220 V AC / DC
(MES114F)
● 4 relay outputs
To perform the control
and monitoring functions

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 13


Modularity
Modular architecture
Sepam series 20 / series 40
Temperature acquisition
remote module
● MET148 - 2
● Measurement of 8 or 16
temperatures
● By Pt100, Ni100 or Ni120
temperature sensors

For better transformers, motors and


generators protection

● Sepam series 20 :
1 module / 8 temperature inputs
● Sepam series 40 :
2 modules / 16 temperature inputs

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 14


Modularity
Modular architecture
Sepam series 20 / series 40
1 analog output
remote module

● MSA 141

● 0-10mA, 0-20mA or
4-20mA

To have one
remote measurement

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 15


Modularity
Modular architecture
Sepam series 20 / series 40
Communication
interfaces

● ACE 949-2, ACE959, ACE937,


ACE969TP, ACE969FO

Communication protocols :
● Modbus RTU
● DNP3
● IEC 60870-5-103

Physical interface:
● 2-wire RS 485
● 4-wire RS 485 (modbus only)
● Fiber optic

To connect Sepam to
communication network

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 16


Modularity Communication interfaces
Selection guide
ACE949-2 ACE959 ACE937 ACE969TP ACE969FO

(1) Exclusive choice between S-LAN and E-LAN.


(2) Not available with Modbus protocol.

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 17


Modularity
Modular architecture
Sepam series 20 / series 40
Sepam software tools

● SFT2841, software for


● Sepam parameters
● protection settings
● local or remote operation

● SFT2826,
disturbance recording data
display software

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 18


Modularity
Your solution
at the best cost!
Sepam series 20 / series 40
maximum configuration

● 10 inputs / 8 outputs
(1 MES114 module)

● 1 analog output
(1 MSA141 module)

● 1 communication ports
(1 ACE interface)

● Temperature sensor inputs


● Series 20: 8 inputs
(1 MET148-2 module)
● Series 40: 16 inputs
(2 MET148-2 modules)

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 19


Sepam Protection Relay
For your peace of mind
I. Solutions

II. Modularity

III. Performance

IV. Simplicity

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 20


Performance

Sepam series 20 performance

● Phase and earth fault protection


● Earth fault protection with 2nd harmonic
restraint
● Switching between groups of settings A & B
● Logic discrimination, for a quick, selective
tripping of the protection functions

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 21


Performance

Sepam series 40 performance


● Current and voltage metering

● Directional protection functions


● Dir. earth fault, suited to all neutral earthing
systems, impedant, compensated or isolated
● Dir. phase overcurrent…

● CT / VT supervision

● Logic equation editor,


to program specific control functions

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 22


Performance
Sepam 20 & 40 range,
robust and compact
● Case made of insulating material
● light-weight
● anti-corrosion

● Excellent immunity to radiated fields

● IP52 / NEMA12 on front panel

● Class 2 mechanical robustness


(shocks, jolts, vibrations and earthquakes)

● Operating temperature
from -25°C to +70°C

● Immunity to salt mist


● Corrosion withstand: 2-gaz test (H2S and SO2 )
<100mm
Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 23
Circuit breaker control

● Suitable for all types of trip unit

● Local or remote opening and closing

● Recloser co-ordination

● Trip circuit supervision and checking of


discrepancy

● Inhibition of closing

A complete function,
dependable and ready to use!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 24


Performance

Logic equation editor in series 40, 60 & 80


To adapt Sepam functions
to suit your needs!

● Included in SFT2841 software


tool

● Boolean operators
NOT, AND, OR, XOR,
timers, latched relays,
time programmable pulses

● On logic inputs and protection


data

● Syntax checking

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 25


Performance

Metering
All the measurements are
available:
● RMS and residual phase
currents
Pmax=3,2
E Active+
U21=
P=
I1=2,1
178A = MW
6,6
MW kVRMS
● Peak demand and average
currents tore= 5,2A
Io 755454
Qmax=1,0
I2=900k
Q=
U32= 6,6MW.h
177A VAr
kV
MVAr
RMS
● Phase-to-neutral, phase-to- E Active- =
phase and residual voltages S=
U13=
0I3=2,3
178A
50 6,6
72MVA kV
100MW.h
150%Ino
RMS

● Active, reactive, apparent


power and power factor
● Active and reactive energy

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 26


Performance

Switchgear diagnosis
Continuous, comprehensive breaking device
monitoring:

● Number of operations

● Operating time

● Charging time

● Cumulative breaking current,


overall and by levels of fault current

For effective preventive maintenance!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 27


Performance

CT / VT supervision
Permanent checking of the complete
measurement chain, from the CT and VT
sensors up to the Sepam analog inputs :

● Checking of the consistency of the currents


and voltages measured

● Acquisition of the phase and residual VT


protection fuse melting contacts

To detect the loss of measures


and avoid any nuisance tripping

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 28


Performance

Network diagnosis assistance


● Disturbance recording
● 1 to 19 records in
COMTRADE format
● max. record: 22s
● samples/period max: 36

● Phase unbalance
● Tripping currents

● Alarm history
● Tripping context

For better understanding!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 29


Performance 2 types of communication
network
With ACE 969 TP or FO, Sepam has
two communication ports to connect
to 2 independant communication
networks:

 The S-LAN port


(Supervisory Local Area Network) is
used to connect Sepam to a
communication network dedicated
to supervision

 The E-LAN port


(Engineering Local Area Network) is
reserved for specific Sepam setup,
operating and ajustment functions:
this port is connected to SFT2841
software tool

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 30


Performance
Examples of architectures S-LAN networks
Single S-LAN network Two parallel S-LAN networks (Sepam series 80)

Parallel S-LAN and E-LAN Two S-LAN networks and one E-LAN network
networks in parallel (Sepam series 80)

E-LAN
Legend
S-LAN network
 Protocol selection :
Modbus, DNP3 or
IEC 60870-5-103
 Physical interface :
2-wire or 4-wire RS 485,
fibre optic with star or
ring architecture
E-LAN network,
2-wire RS 485

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 31


Performance
Examples of architectures E-LAN networks
Single E-LAN network Single E-LAN via modem (phone-line connection)

Modem Modem

S-LAN and S-LAN networks over Ethernet TCP/IP


Legend
S-LAN network
 Protocol selection :
Modbus, DNP3 or
IEC 60870-5-103
 Physical interface :
2-wire or 4-wire RS 485,
fibre optic with star or
ring architecture
E-LAN network,
2-wire RS 485

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 32


Performance Ethernet connection
and Webserver

 Integration of Sepam in your


Ethernet network
 EGX200 or EGX400
Ethernet/Modbus gateway
 Modbus / TCP/IP multi-
master protocol
 fast transmission rate
(10/100 Mbps)

 Simple consultation of Sepam


data
 from a PC with
internet/intranet browser
 presented in Web/Sepam
pages embedded in the
EGX400 gateway

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 33


Performance Integrated in PowerLogic System

Industrial and commercial network


management system, including:

 Power management software


tools

 Power quality measurement and


analysis products

 Masterpact and Compact


communicating circuit breakers

 Sepam multifunctional protection


units

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 34


Simplicity

Simplified choice
● A consistent product range, organized by application

● Universal power supply,


for Sepam and its logic inputs:
● series 20/40: 24-250VDC & 100-240VAC
● series 60 & 80: 24 to 250VDC

● Common optional modules and accessories for the whole


Sepam range:
● 1 temperature module compatible with Pt100, Ni120 or
Ni100 RTDs
● 1 analog output module
(0-1mA, 4-20mA, 0-10mA, 0-20mA)

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 35


Simplicity
Residual current metering by CT or core balance CT
Residual current is metered by:

● Specific core balance CT, for


accurate measurement (CSH120 or
CSH 200)

● Other core balance CT with an


ACE990 interface

● 1A/5A CT with an interposing ring


CT(CCA630 + CSH30)

● 1A or 5A and residual current


transformers in the same sensor
(CCA634)

or calculated based on the 3 phase


currents

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 36


Simplicity

Base unit easy to install


● Reduced installation
constraints:
Sepam is compact, light, with a
reduced depth
● < 100 mm (series 20/40)
● < 225 mm (series 60/80)

● Terminal and connector


identification

● Disconnectable
without any precautions

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 37


Simplicity
Addition of optional modules simplified
● Input / output modules
mounted on the base unit

● Remote modules
● assembly on DIN rail
● connection via prefabricated
cords fitted with RJ45 plugs

To use at best
the available space!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 38


Simplicity
Two connection modes
Two types of auxiliary supply
connectors are offered :

● Screw type

or

● Ring lug type

To suit your
connection habits

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 39


Simplicity
Easy to commission
● Predefined functions, ready to
use:
● defined by application
● to activate and set according
to the need

● Simple to set functions


● with advanced UMI
(series 20/40)
● with SFT2841 software

For fast, dependable


implementation!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 40


Simplicity

SFT2841: a user-friendly, powerful software tool


● 2 operating modes
● unconnected
● connected to Sepam

● Windows environment

● On-line help

● Available in 4 languages,
customizable (French,
Spanish, English UK and US)

To derive maximum
benefit from your Sepam!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 41


Simplicity

SFT2841: use in unconnected mode ...

● Preparation of
● Sepam parameters
● protection settings

● File management

To reduce
commissioning time!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 42


Simplicity
SFT2841: use in connected mode ...
SFT2841: Sepam remote Remote connection modes :
 via RS 485 serial link SFT
operation (E-LAN  via Ethernet TCP/IP 2841
network)  via modem and telephone line

 Local connection:
SFT2841 on laptop, connection
to advanced UMI by CCA783 cord E-LAN
@1 @2 @3 @4
 Remote connection for
protection functions management
and network diagnosis:
SFT2841 on desktop connected
to Sepam units via E-LAN
CCA783
communication network

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 43


Simplicity

SFT2841: use in connected mode ...


● Loading of parameters and
protection settings

● Current operation

● Recovery of:
● parameters and
protection settings
● disturbance recording
records
● alarm history

To facilitate
servicing operations!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 44


Simplicity

SFT2841: customization tool


● Customization of control and
monitoring functions

● Logical equation editor

● Customization of alarm
messages on advanced UMI

● Customization of signal
lamp labels

To fit your needs!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 45


Simplicity User Machine Interface
easy to use in normal operation …

● Graphical LCD display

● Clearly understandable display of all


data

● Dedicated keys, identified by icons

● For intuitive use!

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 46


Simplicity

... and for servicing, after tripping.

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 47


Simplicity

Understood by all ...


... it speaks all languages!
● Screen language may be
customized

● Accommodates all graphics:


● typographical characters
● drawings

● Texts in English remain


available

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 48


Sepam protection relay:
to win all across the board!

More solutions

More modularity
More performance

More simplicity
End Presentation

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 50


©2014 Schneider Electric. All Rights Reserved.
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies or their respective owners.

Schneider Electric - Services Division – Sepam 1000+ Training – June 2019 51

You might also like