Advr 054
Advr 054
SECTION 1 : SPECIFICATION
Sensing Input (A, C) Average Reading EMI Suppression
Voltage 170 − 260 Vac @ 220 Vac, 1 phase 2 wires Internal electromagnetic interference filtering
340 − 520 Vac @ 440 Vac, 1 phase 2 wires
220/440 Vac, DIP switch setting Static Power Dissipation
Frequency 50/60 Hz, DIP switch setting Max.8 watts
___________________________________________________________________________________________
2 ADVR-054
SECTION 2 : APPEARANCE / DIMENSIONS / INSTALLATION DRAWING
50.0
[1.96"] M4 L25
8.5
[0.33"]
27.0
[1.06"]
44.5
[1.75"]
Unit : mm
[inch]
ATTENTION
1. Only qualified technicians should install and operate the AVR.
2. The voltage regulator may be installed at any suitable location on the generator set (dimensions are
shown in Figure 1). It is recommended that unit is mounted vertically with the green resistors on the
regulator upwards to achieve the best cooling effect.
3. All AC voltage sensing readings are average value only.
___________________________________________________________________________________________
ADVR-054 3
SECTION 3 : DIP SWITCH SETTINGS, LED INDICATORS AND ADJUSTMENTS
Over Excitation (O/E) LED VOLT Voltage Adjustment
- +
When the excitation voltage is greater than 35% The adjustment range is set by
of input power voltage, the LED will lit after 5 sec. SW2.
If the DIP switch SW3 set at OFF then it will also
shut off excitation output at the same time. STAB Stability Setting
S F With No Load, slowly turn the
U/F LED STAB counterclockwise until
Under Frequency Protection status. voltage becomes unstable then
turn clockwise about 1/5 turn.
DIP Switches U/F Under Frequency Protection
40 51
System Freqency SW1 ON:50 Hz, OFF:60 Hz (50) (61) 50 Hz system preset at 45 Hz,
Sensing Input SW2 ON:220V, OFF:440V 60 Hz system preset at 55 Hz,
O/E Protection SW3 ON:Disable, OFF:Enable To change the setting, see the
Adjustment Step 3.
ADVR-054
Field Field
ADVR-054 ADVR-054
Figure 3 170 − 260V sensing connection (Option 1) Figure 4 170 − 260V sensing connection (Option 2)
N N
R R
S G S G
T
~ T
~
Field Field
Aux.winding
1000 Ohm 1000 Ohm
EXT. VR EXT. VR
ADVR-054 ADVR-054
※ Package include 4 pcs of M4 L25 Round head bolts and 2 pcs of terminal jumpers.
※ Use only replacement fuses specified in this user manual.
※ Appearance and specifications of products are subject to change for improvement without prior notice.
___________________________________________________________________________________________
ADVR-054 5