1) This document provides operating instructions for a hot tub model SPA-308, outlining its various functions and control panel buttons. 2) The hot tub has a 6KW heating system, 2 surfing pumps, 1 circulation pump, air blower, spa light, CD audio, radio, and temperature display and settings. 3) The control panel allows the user to set functions like pre-heating, circulation cleaning, time, temperature, locks, and more using the labeled buttons. Detailed steps are provided for setting these functions.

Uploaded by

Marius Balica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views15 pages

Spa 308 220V

1) This document provides operating instructions for a hot tub model SPA-308, outlining its various functions and control panel buttons. 2) The hot tub has a 6KW heating system, 2 surfing pumps, 1 circulation pump, air blower, spa light, CD audio, radio, and temperature display and settings. 3) The control panel allows the user to set functions like pre-heating, circulation cleaning, time, temperature, locks, and more using the labeled buttons. Detailed steps are provided for setting these functions.

Uploaded by

Marius Balica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

HOT TUB

Model SPA-308

OPERATING INSTRUCTION

1
1. I、Illustration to buttons

Fig.1:Control Panel

MIN
“ ”Frequency up- searching / Minute “ ” On-off/Setting confirm

HOUR
“ ” Frequency down- searching/ Hour “ ” Radio or CD Switch/ On-off
+
“ ” Volume up/ Set switch “ ” Blower On-off/℉ or ℃ Switch
-
“ ” Volume down/ Open “ ” Spa Light On-off
MEM
“ ” Radio channel Memory/ Lock “ ”Surfing pump 1 On-off

SET “ ” Surfing pump 2 On-off


“ ” Radio channel read / Close

“ ” Lasting Circulation Cleaning On-off “ ”Surfing pump +circulaltion pump 3 On-off/Set


Circulation Cleaning Time

“ ” Heating On-off / Set Pre-heating “ ” Set Temperature


Note:
.The functions listed with bule letters only works on the condition of on-off

Chart 1

II、Function Summary

1、Max. with 6 KW heating system, pre-heating seting, water temperature displaying and setting
2、Max. with 2 pcs surfing pumps,1 pc circultion pump, and one pc air blower.

2
3、Spa light and ozone setting
4、CD audio-input / Display of radio frequency,it can be preserved 10 channels
5、Volume display and 87 volume adjusting
6、Circulation cleaning/ time set circulation cleaning
7、24 hours display and setting
8、Memory preserve once power off
9、Fahrenheit & Celsius can be mutually switched
10、Antifreezing functions
11、Keys with backlight
12、Lock settingl
13、Three-phase or single-phase available,can be choosed 110-120VAC or 220-240VAC
14、Choice with offering a AC for circumscribing DVD or TV
15、Choice of power controlled

III、Operation

Fig.3::Normal Temperature Display Fig.4:Senor on/short circuit Display

1、When you first turn on the spa, the backlight control panel is dim and LCD shows current time and
temperature. If spa happen with the short circuit the panel will display code “E1”. When the radio frequency is
displayed “----” it indicates that the spa is in “power off” mode, and pre-heating and circulation cleaning function
are in off status.

2、Lock memory Mode:


MEM
It is an optional function. Key board will be locked by pressing “ ” once when panel is in off
MEM
mode. Pressing continuous twice of “ ” to unlock the panel, the word “LOCKED”will disappear.

3、Time Adjusting:
In the status of “Power off” and unworking of pre-heating and circulation cleaning.

MIN HOUR
Pressing “ ”or“ ” to start time adjusting. When Minute and Hour flashing, you can adjust
your desired time.

HOUR
It will be added one hour when pressing “ ” each time and the hours can be adjusted continually

HOUR
when pressing “ ” without stopping. The hour adjustment range is 00-23.
3
MIN
It will add one minute when pressing “ ” each time and the minutes could be adjusted continually

MIN
when pressing “ ” without stopping. The minute adjustment range is 00~59
The system will quit the time-setting status automatically after 6 seconds without pressing any buttons

4、Pre- circulation-cleaning Setting:

The display will show clearly whether circulation clearning is work or not. See following Fig 5-6:

AM AM

Fig.5:Circulation-cleaning off Fig.6:Circulation-cleaning on

Pre- circulation-cleaning Setting should be under the power off status. just turn on
the spa , LCD will display “---”

1) 、Press“ ” to start Circulation-cleaning setting mode, LCD showes “ ” and it is flashing.You can

set the pre-circulation time simultaneously(refer to chart 2 and illustration 2). Press “ ” again to turn

off the circulation cleaning,and the “ ” will disappear.

2)、Press“ ”(minutes)and“ ”(hours)to adjust the time.

HOUR
It will add 1 hour when pressing “ ” each time and the hours could be added continually when

HOUR
pressing “ ” without stopping. The adjustment range is 00-23.

MIN
It will add 1 minute when pressing “ ” each time and the minutes could be added continually when
MIN
pressing “ ” without stopping. The adjustment range is 00~59.

3)、Press“ ” to set lasting time of circulation.

4
It will be added 5 minutes by pressing “ ” and 1 hour by pressing“ ”each time。The maximum
working time is 19 hours and 55 minutes.

4)、Finally Press “ ” to confirme all settings .

Notice: The system will be exit automatically by pressing key of “ ”

1) Pre-circulation setting be turn off

2)
starting time of circulation

3) Lasting time of circulation

4)
Finished

Chart 2

***Notice***

1 All the setting of Circulation-cleaning must be set on Power OFF status


2 Circulation PUMP and OZONE are not working while setting the circulation
cleaning.

5
5、Preheating Setting (if required):
The display will show clearly whether preheating work or not. See following Fig 7-8:

ON OFF

Fig.7:Pre-heating On 图 8:Pre-heating Off

Pre- heating setting should be under the power off status. just turn on the spa , LCD
will display “---”

1) 、Press“ ” to start Pre-heating setting mode, LCD flashes of “ON” , You can set the pre-heating time

simultaneously (refer to chart and illustration 3). Press“ ”to turn off the pre-heating ,and the

“ ” will disappear on panel.

2)、Press“ ”(minutes)and“ ”(hours)to adjust the time.

HOUR
It will be added 1 hour when pressing “ ” each time and hours could be added continually when

HOUR
pressing the “ ” without stopping. The adjustment of hours is 00-23

MIN
It will be added 1 minute when pressing “ ” each time and minutes could be added continually

MIN
when pressing the “ ” without stopping. The adjustment range is 00~59

3)、Press“ ” to set lasting time of circulation.

It will be added minutes by pressing “ ” and 1 hour by pressing“ ”each time。The maximum
working time is 19 hours and 55 minutes.

4)、Press “ ” again to set the water temperature(please refer to Chart 3 and illustrate 4). Press “ ”
button to change the temperature. The range of temperature setting is: 15~43℃。

5)、Press “ ” to confirm all settings.

Notice: The system will be exit automatically by pressing key of “ ”

6
1) Pre-heating setting is turn off

2) Starting time of pre-heating

3) Lasting time of circulation

4) Preset temperature

5)
Finished

Chart 3

***Notice***
1、All setting of preheating must be in Power OFF mode, just turn on the spa,the
LCD will display “---”

2、Please note that it shows "on" or "off" on the LCD. "on" means preheating is
turned on mode. when the time reaches your desired time, heater will work. If panel
shows "off", means that heater not be set.

3、Circulation PUMP and HEATER not working while setting preheating.

6、About Pre-heating

When the time reaches your desired time, LCD shows “ON” and the tub is filled with water, heater works.
circulation pump works simultaneously. The count down time will be shown on the LCD screen, till the preset time
finished.

The preheating will be turned off automatically once the preset time is finished.

7
Or Pressing the “ ” key can stop preheating.

***Notice***
i. When setting temperature is lower than or equal with current water
temperature , Even preheating is on status, the circulation PUMP and
HEATER are not working。
ii. When the HEATER is a “I” type frame,The power of circulation PUMP must
reach 1HP。Otherwise the heater don’t work due to not enough water
pressure to drive pressure switch.
iii. If above two condiction still not make the heater work, Please short the line
of water pressure switch。

7、Circulation-cleaning:

As the current time is as same as the preseting time, the preset is “on” too and the tub is filled with water, the
circulation cleaning will start, the circulation pump works at the same.. The LCD shows the countdown time. All
the surfing pumps and blower will work for 30 seconds at every 30 minutes. The Ozonier works at every 15
minutes.

The circulation cleaning will be turned off automatically once the countdown time is finished or By pressing

the “ ” key to turn off directly.

8、Operation to Power ON/ OFF


Pressing the key “ ” in “power-off” status to enter the “power-on” status. To pressing the in
the status of “power-on” to enter the “power-off” status. The LCD screen shows the on or off.See following
Fig.9-10

AM AM
OFF OFF

Fig.9:Power Turn OFF Status Fig.10:Power Turn ON Status

9、Temperature setting:
In the status of “Power-on” and “HEATER” is working.It will add 1 centigrade by press “ ” each time,the

temperature will be added continually till reach 43 centigrade(109 Fahrenheit ) by press “ ” without

stop.Press “ ” again,and the temperature is show 15℃(59 Fahrenheit)。The range of adjustment is:
15~45℃(59~109 Fahrenheit)。
10、Operation Radio & CD:

8
AM

PUMP3

Fig.11:Radio frequency is 105.2 MHZ,Save the present frequency to channel 3 (Save channel)
or Exchange the frequency form channel 3 to the present (Searching channel)

I、“ ” key is the ON/OFF key of radio and CD。and it is only available in the status of power on.

The first pressing “ ” is turning on the radio,the second pressing “ ” will turn off the radio and turn on

the CD at the same time,and the third pressing“ ” ,will turn off the radio and CD simultaneously.

Ⅱ、LCD will show present frequency and volume of the radio after turning on the radio。

Ⅲ、In the working of radio, The volumle of the present radio frequency can be changed by pressing

MIN HOUR
“ ”and “ ”

Ⅳ、Pressing the key “ SET ” will take out the memorized radio frequency,Pressing the key

“ SET ” continually will take out the memorized radio frequency from channels will be saved at present
channel by pressing this key continually。If none of the channel, LCD will display “---”。
MEM MEM
Ⅴ、Press the key “ ” could memorize the present radio frequency, Pressing the key “ ”
continually will memorize the present radio frequency in different channel。 The channel of max is 10,Name of
channel is 0-9。
VOL+
SET OPEN
Ⅵ、The volume can be changed by pressing key “ ”and“ ”

11、Operation of Pump:
PUMP2
The Button , operates pump 1 ; The Button operates pump 2; The button
PUMP3
operates pump 3,Also the pump 3 is the circulation pump。When pump 3 is turned on the LCD will

show “ ”, whether the heating and circulation is on or off. The LCD will show when pump3 is off and the
heating, including pre-heating and circulation is about to start

12、Operation of lasting circulation cleaning:

Press the key “ ” at any time to turn on or off the lasting circulation cleaning, work mode is like the
preset circulation cleaning. The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer
works for 15 minutes at every 105 minutes,and repeat in this program .
Ozonater only work under the circulation cleaning works.

IMPORTANT: Please ensure that the ozone function is not in use whilst bathing in the spa
9
During the lasting circulation cleaning,press” ” key can stop the heating ,but start again the heating.

13、Operation of spa lights:

Press the “ ” key to turn ON/OFF of the the LED lights and the Fiber optic lights.
14、Setting the constant Temperature Settings:

1)、Pressing the “ ” button will start the constant temperature heating.


2)With the setting above, the circulation pump will work automatically.
3)、If the temperature is set at 35℃, when the water temperature reaches or exceeds 36℃, the heater will
be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature
reaches or lower than 34℃, the heater will start up again.
4)、In the case of an error the LCD shows ”E1” or “FF”. If this happens, the thermostatic heating sytem
will NOT be available, the heater doesn’t work.

15、Operating the Air Blower:


Press“ ” controls the blower

16、Fahrenheit & Celsius Temperature shift:


In the status of“Power off” pressing the key “ ” can change the mode of Fahrenheit & Celsius degree

17、When there is no water in the spa. All surfing pumps, and heating system can not
start up. However the corresponding signals will flash on the LCD.

18、Prevent freezing function:


This function is only available while the spa is on normal power supply.The heater & circulation pump will work
automatically once the water temperature is at below 5℃, when the water temperature is reach at 10℃, heating
will stop.

IV、Electric parameters
1、Performance index:
Rated voltage: 220V/50Hz Maximum working current:60 A/220V-240V~
Voltage-resistance:1250V/1 minute without penetration。 Isolative resistance: 》10MΩ
Water resistance grade:IPX5 Electric shock resistance:first grade

((2) Output loading index


Heater: AC220V/3KW x 1. Water pump: AC220V/2 HP×2
Air pump:AC220V/700W×1
Spa light: AC12V/20W Ozone: AC12V/15W
Radio: 1) Frequency Range: FM: 87.0~108.0MHz

10
2) Maximum Output Power: 10W
3) Speaker:8Ωdamp proof speaker
5.Warning Information

a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
c. This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
d. Children should be supervised to ensure that they do not play with the appliance.
e. Details concerning cleaning and other maintenance
f. Maintenance of water purity, especially PH values and chlorine concentrations.
g. Cleaning and disinfection
h. Use and installation of a cover.
i. Disposal of water
j. Precautions to avoid damage due to water freezing
k. Precautions to avoid damage when the appliance is left empty for extended period.

2.2 Sub-clause 7
The installation instruction shall state the substance of the following:
- Earthed appliances must be permanently connected to fixed wiring;
- The appliance should be supplied through a residual current device (RCD) having a rated residual operating
current not exceeding 30 mA.
- The floor has to be capable of supporting the expected load.
- An adequate drainage system has to be provided to deal with overflow water.
- Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone
and that equipotential bonding is carried out.

1、 DANGER:RISK OF ELECTRIC SHOCK,Connect only to a circuit protected by a Ground

WARNING Fault Circuit lnterrupter.


2、Grounding is required. The unit should be installed by a qualified service representative and
ground.
3、FOR YOUR SAFETY-This product should be installed by a professional service
technician,qualified in hydrotherapy bath installation.
4、lt’s prohibited to cover the instrument with something while opeating.
5、when using at the first time ,Be sure there is water in heater pipe before staring.
6、parts containing live parts, except parts upplied with safety extra-low voltage not Exceeding
12V,must be inaccessible to person in the bath;
8、earthed appliances must be permanently connected to fixed wiring;
9、the appliance should be supplied through a residual current device (RCD)having a rated
residual operating current not exceeding 30 mA.
10、If the mains cord of this appliance is damaged,It must only bereplaced by our service
representative,As special tools and/or parts are required

11
Solutions of Fault
Phenomenon Reason How to Solve the problem
1. The electric leakage switch was 1. Check and eliminate the malfunction,
breaked off restart the spa
No power supply
2. The Fuse be break off 2. Please change fuse

1. The plug which connected with the 1. to connect the plug of the control
No display on control
panel loose or disconnected panel and the main box
panel
2. The Panel happened with malfunction 2. Change a new control panel

1. Power of the light be break off 1. To check if cable of the light is well
2. Fuse be break off connected with main box or not
LED light not work
3. light be burn 2. Change a fuse
3. Change a new lampwick
1. Ozonater burn 1. Change a new ozonater
2. Fuse be break off 2. change a fuse
Ozone not work 3. Cable of the ozonater be cut off 3. check if the cable of the main power
is connected with the main box or
not.
1. temperature detector be cut off or 1. Connect the temperature detector
Displaied “E1””FF” in shortcirculate 2.Change a new temperature detector
control panel 2. plug of the temperature detector be
nundated by water

being incapable of
activate water pump,and 1.water not achieve the appointed level 1. To add more water to make it up to
water pump icon 2. water detector not connect well the water detector
flashing 2. To re-connect the line of water
detector
Heater not work, and 1. setting water temperature lower then 1. set the temperature degrees higher
heating icon on panel the water temperature than the water in tub
flashing temperature(between 15 and 43 °C。

1. silicon plaster not good 1. To remove the jets then re-install


2. PVC plaster not good one
Leakage
3. Blow out of the water pipe 2. To plaster once again
Change water pipe

12