100% found this document useful (1 vote)
429 views12 pages

DBP 12A Manual PDF

This document provides specifications for several DBP series active speaker cabinets and subwoofers, including the DBP-15A, DBP-15SA, DBP-12A, and DBP-12MA models. Key details summarized include power output ratings from 300-350 watts, frequency response ranges from 42Hz-20kHz depending on the model, maximum SPL levels from 121-125 dB, input connections of XLR and line level combo jacks, and various controls including volume, EQ settings, and limiters. Safety symbols and instructions are also defined at the end.

Uploaded by

Pandu S Adrianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
429 views12 pages

DBP 12A Manual PDF

This document provides specifications for several DBP series active speaker cabinets and subwoofers, including the DBP-15A, DBP-15SA, DBP-12A, and DBP-12MA models. Key details summarized include power output ratings from 300-350 watts, frequency response ranges from 42Hz-20kHz depending on the model, maximum SPL levels from 121-125 dB, input connections of XLR and line level combo jacks, and various controls including volume, EQ settings, and limiters. Safety symbols and instructions are also defined at the end.

Uploaded by

Pandu S Adrianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

SPEAKER ENCLOSURE

User's Manual

DBP SERIES
SPEAKER/ENCLOSURE

INDEX
TECHNICAL SPECIFICATION
INTRODUCTION 3
DBP-15A 2-Way 15" Active Speaker Cabinets QUICK START - SPEAKER CABINETS 3
Power System 350Watts RMS CONNECTIONS 10
Frequency Response (-10dB) 54Hz-18kHz, FLAT/ 47Hz-20kHz, EQ. LOUDNESS
Maximum SPL @ 1m 122dB Continuous/125dB Peak (Calculated)
WIRE CONNECTIONS 13
Coverage ( HxV ) 70 x 70 nominal FREQUENCY RESPONSE 14
Transducer Low 15" Woofer, 2.5" voice coil, with double ventilation
TECHNICAL SPECIFICATIONS 17
Transducer High 1" Neodymium on Spherical Horn ( Tractrix contour)
Active Crossover 2kHz under analog processor, FLAT or EQ. LOUDNESS
Input Connector LINE-COMBO/ LINK-XLR-M Balanced (15kohm)
Input Level Line 0dBu
Volume Control/ Flat-Eq.Loudness/ Power ON with Green LED/
External Control
Clip Limiter with Red LED/ Ground Lift.
Power Supply 120-240 Volt - Switching Power Mode
Chipboard cabinet, glued and reinforced, covered in black carpet;
Enclosure Construction
black metal corner and rubber foot
Mounting One standard pole-mount plus two plastic handle
Dimensions (HxWxD) 670 x 437 x 373 mm (26.40" x 17.20"x 14.67" )
Net Weight 23.06kg / 50.84 lbs
Shipping Weight 26.72kg / 58.91 lbs

DBP-15SA 15" Active Subwoofer Speaker Cabinets


Power System 350Watts RMS
Frequency Response (-10dB) 42Hz-125Hz
Maximum SPL @ 1m 121dB Continuous/124dB Peak (Calculated)
Transducer Low 15" Woofer, 2.5"voice coil, with double ventilation
Active Crossover HPF 80Hz under analog processor
L-R Input (Combo/ XLR-F) / L-R Link (2-XLR-M) /
Input Connector
L-R Output (2-XLR-M) Balanced (15kohm)
Input Level L-R Input Line 0dBu
Volume Control/ Phase Switch / HPF-80Hz By-Pass/ Power
External Control
ON with Green LED/ Clip Limiter with Red LED/ Ground Lift.
Power Supply 120-240 Volt, in Switching Power mode.
Chipboard cabinet, glued and reinforced, covered in black carpet;
Enclosure Construction
black metal corner and rubber foot
Mounting One metal standard pole-mount plus two plastic handle
Dimensions (HxWxD) 558 x 438 x 498 mm (21.97" x 17.24" x 19.61" )
Net Weight 26.78kg / 59.04 lbs IMPORTANT!
Shipping Weight 31.25kg / 68.89 lbs Please read this manual carefully before
operating this unit for the first time.

19
SPEAKER/ENCLOSURE

SAFETY RELATED SYMBOLS Unplug this apparatus during lightning TECHNICAL SPECIFICATION
storms or when unused for long periods
of time. DBP-12A 2-Way 12" Active Speaker Cabinets
Power System 300Watts RMS
External Connection Frequency Response (-10dB) 57Hz-18kHz, FLAT/ 47Hz-20kHz, EQ.LOUDNESS

The symbol is used to indicate that The external wiring connected to the output Maximum SPL @ 1m 121dB Continuous/ 124dB Peak (Calculated )

some hazardous live terminals are hazardous live terminals requires installation Coverage ( HxV ) 70 x 70 nominal
involved within this apparatus, even by an instructed person, or the use of ready- Transducer Low 12" Woofer, 2"voice coil, with double ventilation
under the normal operating conditions. made leads or cords. Transducer High 1" Neodymium on Spherical Horn (Tractrix contour)
Active Crossover 2kHz under analog processor, FLAT or EQ. LOUDNESS
The symbol is used in the service Do not Remove any Cover Input Connector LINE-COMBO/ LINK-XLR-M Balanced (15kohm)
documentation to indicate that specific There are maybe some areas with high Input Level Line 0dBu
component shall be only replaced by voltages inside, to reduce the risk of electric External Control Volume Control/ Flat-Eq.Loudness/ Power ON with Green LED/
the component specified in that shock, do not remove any cover if the power Clip Limiter with Red LED/ Ground Lift
Documentation for safety reasons. supply is connected. Power Supply 120-240 Volt - Switching Power Mode
Enclosure Construction Chipboard cabinet, glued and reinforced, covered in black carpet;
Protective grounding terminal. The cover should be removed by the qualified black metal corner and rubber foot.
personnel only.
Alternating current /voltage. Mounting One standard pole-mount plus two plastic handle
No user serviceable parts inside. Dimensions (HxWxD) 603 x 391 x 350mm (23.74" x 15.39 x 13.78")
Hazardous live terminal .
Net Weight 18.63 kg / 41.07lbs
ON: Denotes the apparatus turns on. Fuse Shipping Weight 21.82 kg / 48.10lbs
OFF: Denotes the apparatus turns off, bec- To prevent a fire, make sure to use fuses
ause of using the single pole switch, be sure with specified standard (current, voltage,
type). Do not use a different fuse or short DBP-12MA 2-Way 12" Active Monitor Speaker Cabinets
to unplug the AC power to prevent any
electric shock before you proceed your circuit the fuse holder. Power System 300Watts RMS
Frequency Response (-10dB) 64Hz-18kHz, FLAT/ 60Hz-20kHz,EQ.LOUDNESS
service. Before replacing the fuse, turn OFF the Maximum SPL @ 1m 121dB Continuous/124dB Peak (Calculated )
WARNING: Describes precautions that apparatus and disconnected the power
Coverage ( HxV ) 70 x 70 nominal
should be observed to prevent the danger source.
Transducer Low 12" Woofer, 2"voice coil,with double ventilation
of injury or death to the user. Transducer High 1" Neodymium on Spherical Horn (Tractrix contour)
Protective Grounding
Active Crossover 2kHz under analog processor, FLAT or EQ. LOUDNESS
Disposing of this product should Before turning the product ON, make sure that Input Connector LINE-COMBO/ LINK-XLR-M Balanced (15kohm)
not be placed in municipal waste it is connected to Ground. This is to prevent the
Input Level Line 0dBu
and should be separate collection. risk of electric shock. Never cut internal or
External Control Volume Control/ Flat-Eq.Loudness/ Power ON with Green LED/
external Ground wires. Likewise, never remove
Clip Limiter with Red LED/ Ground Lift.
CAUTION: Describes precautions that Ground wiring from the Protective Ground
Power Supply 120-240 Volt - Switching Power Mode
should be observed to prevent danger of the Terminal.
Enclosure Construction Chipboard cabinet, glued and reinforced, covered in black carpet;
apparatus. Never cut off the internal or external pro- black metal corner and rubber foot.
tective grounding wire or disconnect the Mounting One standard pole-mount plus one plastic handle
WARNING wiring of protective grounding terminal. Dimensions (HxWxD) 603 x 389.5 x 389.5 mm (23.74" x 15.33" x 15.33" )
Power Supply Net Weight 18.02kg / 39.73 lbs
The apparatus shall be connected to a mains
Ensure the source voltage matches the socket outlet with a protective earthing Shipping Weight 21.42kg / 47.22 lbs
voltage of the power supply before turning connection.

1 18
SPEAKER/ENCLOSURE

Operating Conditions Protect the power cord from being walk-


TECHNICAL SPECIFICATION This apparatus shall not be exposed to ed on or pinched particularly at plugs,
dripping or splashing and that no objects convenience receptacles, and the points
DBP-12 2 - way Passive Speaker Cabinet where they exit from the apparatus.
filled with liquids, such as vases, shall be
Power System 250Watts RMS
placed on this apparatus.
Frequency Response (-10dB) 57Hz-18kHz Cleaning
Sensitivity (1w @ 1mt) 94.5dB SPL To reduce the risk of fire or electric shock, When the apparatus needs a cleaning, you
Impedance 8 (nominal) do not expose this apparatus to rain or can blow off dust from the apparatus with
Maximum SPL @ 1m 118.5dB continuous/121.5dB peak (Calculated) moisture. a blower or clean with rag etc.
Coverage ( HxV ) 70 x 70 nominal Do not use this apparatus near water. Don't use solvents such as benzol, alcohol,
Transducer Low 12" Woofer, 2"voice coil, with double ventilation Install in accordance with the manufacture-r's or other fluids with very strong volatility and
Transducer High 1" Neodymium on Spherical Horn (Tractrix contour) instructions. Do not install near any heat flammability for cleaning the apparatus body.
Passive Crossover 2.25kHz at 12dB/oct, with HF protection sources such as radiators, heat registers, Clean only with dry cloth.
Enclosure Construction Chipboard cabinet, glued and reinforced, covered in black carpet; stoves, or other apparatus (including am-
black metal corner and rubber foot. plifiers) that produce heat. Do not block Servicing
Input Connectors Two Parallel SPK NL-4 for INPUT/ THRU any ventilation openings.
Mounting One standard pole-mount plus two plastic handle Refer all servicing to qualified personnel. To
No naked flame sources, such as lighted
Dimensions (HxWxD) 603 x 391 x 350mm (23.74" x 15.39" x 13.78") reduce the risk of electric shock, do not
candles, should be placed on the apparatus.
Net Weight 16.57kg / 36.53 lbs perform any servicing other than that
Shipping weight 19.82kg / 43.70 lbs contained in the operating instructions unless
IMPORTANT SAFETY INSTRUCTIONS you are qualified to do so .

Read these instructions. Servicing is required when the apparatus has


DBP-15 2 - way Passive Speaker Cabinet Follow all instructions. been damaged in any way , such as power
Power System 300Watts RMS
Keep these instructions. supply cord or plug is damaged , liquid has
Frequency Response (-10dB) 47Hz-18kHz been spilled or objects have fallen into the
Heed all warnings.
Sensitivity (1w @ 1mt) 96.5dB SPL apparatus, the apparatus has been exposed
Only use attachments/accessories spec- to rain or moisture , does not operate
Impedance 8 (nominal)
ified by the manufacturer. normally, or has been dropped.
Maximum SPL @ 1m 121dB continuous/124dB peak (Calculated)
Coverage ( HxV ) 70 x 70 nominal Power Cord and Plug
Transducer Low 15" Woofer, 2.5" voice coil, with double ventilation Do not defeat the safety purpose of the
Transducer High 1" Neodymium on Spherical Horn (Tractrix contour) polarized or grounding type plug.
Passive Crossover 2kHz at 12dB/oct, with HF protection
Enclosure Construction Chipboard cabinet, glued and reinforced, covered in black carpet; The mains plug is used as the disconnecting
black metal corner and rubber foot. device, the disconnecting device shall
Input Connectors Two Parallel SPK NL-4 for INPUT/ THRU
remain readily operable.
Mounting One standard pole-mount plus two plastic handle
A polarized plug has two blades with
Dimensions (HxWxD) 670 x 437 x 372.5mm (26.40" x 17.20 x 14.67")
one wider than the other. A grounding
Net Weight 20.64kg / 45.50 lbs type plug has two blades and a third
Shipping weight 23.93kg / 52.76 lbs grounding prong. The wide blade or the
third prong are provided for your safety.
If the provided plug does not fit into your
outlet, consult an electrician for replace-
ment of the obsolete outlet.
17 2
SPEAKER/ENCLOSURE

INTRODUCTION FREQUENCY RESPONSE


Thank you for your purchasing one of ourDBP speaker enclosures. It is just one of the many SHOW
products that a talented, multinational Team of Audio Engineers and Musicians have developed with DBP-15A
their great passion for music. Your DBP SERIES speaker cabinet is capable of very high sound pressure +110
TT
TTTTTTTTTT TT
TTT
T
TT
T

level and it has been created to give you a performance that is better than any loudspeaker in this
range. They are flexible in their configurations and can be used with single and multiple subwoofers. +100

Enjoy your DBP speaker and make sure to read this Manual carefully before operation!
d +90
B

S
P
L +80
QUICK START - PASSIVE SPEAKER CABINET
Passive, Full-range, two speakers. This is the simplest set-up. You just need a mixer and a +70
stereo amplifier. It is good for small club gigs, disco,etc.
Make all initial connections with all the equipments powered off, and ensure that all the main
volume controls are turned down completely. +60
20 50 100 200 500 1k 2k 5k 10k 20k
1). Connect one side of the speaker cable to the Output CHA/CHB or Binding Post of your Hz

stereo power amplifier and the other side to the Input socket of your DBP speaker cabinet.
2). Complete other connections as illustrated.
3). Turn on your mixer first, then the stereo power amplifier.
4). Turn up the volume controls of your amplifier to about 70%. DBP-15SA
+110
TTTTTTTTTT TTTT
TT TT
TT
5). Use PFL function to get the proper input level for the mixer, and adjust the
Main Mix Level control to manipulate the output level.
+100
6). After use, turn off your stereo power amplifier first, then the mixer.

d +90
B

S
P
L +80

STEREO AMPLIFIER

+70

+60
20 50 100 200 500 1k 2k 5k 10k 20k
Hz

+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP +48V

15 15 15 15
88

15 15 15 15

15 15 15 15 10

MIXER

3 16
SPEAKER/ENCLOSURE

If you use a powered mixer for the passive speakers, it is no need to use an amplifier. make
FREQUENCY RESPONSE sure all the main volume controls of your power mixer are turned down completely.
1). Connect one side of the speaker cable to the SPEAKER OUT of your powered mixer and
the other side to the Input socket of your DBP speaker cabinet.
DBP-12A 2). Use PFL function to get the proper input level for the mixer, and adjust the Main Mix Level
+110
TT
TTTTTTTTTT TTTT
TT
TT
T control to manipulate the output level.
3). After use, turn down of the Main Mix Level control first, then turn off the powered mixer.
+100

d +90
B
LINE IN LINE IN
S
P MAIN OUT L MAIN OUT R
L +80

+70

POWERED MIXER

+60
20 50 100 200 500 1k 2k 5k 10k 20k QUICK START - PASSIVE SPEAKER CABINETS
Hz

Passive, Full-range, four speakers. It is similar to the first set-up but four speakers are
connected instead of two.
DBP-12MA
+110
1).Follow the same steps as described above.
TT
TTTTTTTTTT TTTT
TT
TT
T

2).Connect the THROUGH socket of the first DBP cabinet to the INPUT socket of the
+100
second DBP cabinet.
NOTE: Every time you connect DBP cabinets this way you parallel them to the output of
d +90
the amplifier that will read half of the impedance of one speaker.
B

S
P
L +80

+70

+60
20 50 100 200 500 1k 2k 5k 10k 20k
Hz

THROUGH INPUT THROUGH


INPUT

+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP +48V

15 15 15 15
88

15 15 15 15

15 15 15 15 10

STEREO AMPLIFIER

15 4
MIXER
SPEAKER/ENCLOSURE

QUICK START - PASSIVE SPEAKER CABINETS


FREQUENCY RESPONSE
Passive two subwoofers and two satellite speakers. With this example, the stereo amplifier
drives both the subwoofers and the satellites. In this case we do not call them full-range
anymore because they receive a signal from the subwoofer that is already covered at DBP-12
125 Hz. In this way, the high energetic content of the low frequencies is limited to the +110
TT
TTTTTTTTTT TT
TTT
T
TT
T

subwoofer and the satellite's woofer act like a mid-woofer.


+100

1). Connect one side of speaker cable to the Output CHA/CHB or Binding Post of your
stereo power amplifier and the other side to the Input socket of your subwoofer, with the d +90

second speaker cable connect the Output of the subwoofer to the Input of satellite. B

S
P
2). Complete other connections as illustrated. L +80

3). Turn on your mixer first, then the stereo power amplifier.
+70
4). Turn up the volume controls of your amplifier to about 70%.
5). Use PFL function to get the proper input level for the mixer, and adjust the
+60
Main Mix Level control to manipulate the output level. 20 50 100 200 500 1k 2k 5k 10k 20k
Hz

6). After use, turn off your stereo power amplifier first, then the mixer. DBP-15
+110
TT
TTTTTTTTTT TT
TTT
T
TT
T

+100

d +90
B

S
P
L +80

STEREO AMPLIFIER
INPUT INPUT +70

OUTPUT OUTPUT

+60
20 50 100 200 500 1k 2k 5k 10k 20k
Hz

INPUT INPUT

+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP +48V

15 15 15 15
88

15 15 15 15

SUBWOOFER 15 15 15 15 10
SUBWOOFER

MIXER

5 14
SPEAKER/ENCLOSURE

WIRE CONNECTIONS QUICK START - ACTIVE SPEAKER CABINETS


-. For Active Speaker Cabinets
As to these circumstances, audio connections is mostly intended for the signal flow, so, Active, Full-range, two speakers. It is similar to the passive example but you do not need
determine the wire configuration according to your real application system and its a power amplifier in between the mixer and the two DBP speakers Make all initial connections
with all the equipments powered off, and ensure that all the main volume controls are
connecting facility. Normally, you have the following choices:
turned down completely.

Balanced 1). Connect one side of the signal cable at your mixer into the Main Output Left/ Right
(with 1/4"Jack or XLR) and the other side of the cable in to the Line Input (COMBO)
Tip Tip

TIP RING SLEEVE


SLEEVE RING TIP
Ring
Sleeve
Ring
Sleeve
of your DBP active speaker cabinet (with1/4"Jack or XLR).
1 1
2). Connect the power cord to mains.
1
1
3

3
2
2

2 2
3 3

3). Turn ON your mixer first, then the DBP cabinets.


Tip 1
1
3

Ring 2
2

TIP RING SLEEVE Sleeve 3 4). Turn up the volume control of the DBP cabinets.
5). Use PFL function to get the proper input level for the mixer, and adjust the Main Mix
Unbalanced
Level control to reach the desired output level.
Tip 1
1

Ring 2
6). After use, turn off your active speaker cabinets first, then the mixer.
3
2

TIP RING SLEEVE Sleeve 3

Tip 1
2
1
3
2

Sleeve 3
TIP SLEEVE

Tip Tip
TIP SLEEVE SLEEVE TIP Sleeve Sleeve

Tip Tip
Ring Ring
TIP RING SLEEVE SLEEVE RING TIP Sleeve Sleeve

1 1
2 2
1
1
3

3
2
2

3 3

LINE IN LINE IN

+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP +48V

MAIN OUT L 15 15 15 15
88
MAIN OUT R
15 15 15 15

15 15 15 15 10

MIXER

13 6
SPEAKER/ENCLOSURE

QUICK START - ACTIVE SPEAKER CABINETS CONNECTIONS

Active, Full-range, multiple speakers. This solution is particularly flexible when you have
ACTIVE SUBWOOFERS: DBP-15SA
a large stage and for fixed installations where you want to send the same signal to
different zones like in a Bar, Pub, Restaurant, Church, etc.
Each DBP cabinet has its own volume control so you can adjust different volumes in
different zones.

1). Follow the above steps connecting the MAIN OUTPUTS of the mixer to the LINE D BP-15SA
INPUTS of two DBP active cabinets.

2). Connect the LINE OUT socket of the first DBP cabinet to the LINE IN socket of the
subsequent piece. You can connect as many speakers as you wish in this way.

MODEL
2011/65/EU

(12) IN
SERIAL

LEFT / MONO RIGHT


(6) ON OFF

(7) 0dB
AC INPUT
(1)
LEFT / MONO RIGHT AC INPUT
LINK OUT 110-120V~50/60Hz
LEFT RIGHT 220-240V~50/60Hz
SIGNAL
LIMIT NORMAL
REVERSE
BY PASS AC FUSE POWER
HPF 80Hz POWER 110-120V T6.3AL AC250V
(2)
220-240V T3.15AL AC250V

(8) GND PHASE


POWER CONSUMPTION: 450W Use only with a 250V fuse
(3)
(9) (4)
(5)
LINE IN LINE OUT LINE IN LINE IN LINE IN
LINE OUT
LINE OUT LINE OUT

(10) (11)
(1) ON-OFF main power switch
(2) Input AC power socket with main fuse
(3) POWER, green LED, indicate ON status
(4) BYPASS switch select the hiqh pass filter or by pass
LINE IN LINE OUT LINE OUT LINE IN
LINE IN LINE IN (5) Ground lift switch
(6) Line in right.on xlr connector
(7) Line in left/mono on COMBO CONNECTOR
(8) Link left/right on xlr CONNECTOR
+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP +48V

15 15 15 15
88

15

15
15

15
15

15
15

15 10
(9) SIGNAL/LIMIT, red LED, indicate ON status
(10) VOLUME main power amplifier control

(11) PHASE switch reverse the polarity of the subwoofer output


MIXER
(12) OUT LEFT/RIGHT on 2xXLR CONNECTOR
7 12
SPEAKER/ENCLOSURE

QUICK START - ACTIVE SPEAKER CABINETS


CONNECTIONS
Active, two subwoofers & two satellite speakers. In this example, the mixer is connected
ACTIVE FULL- RANGE :
to the DBP subwoofers and then a 125 Hz covered line signal is sent to the respective
DBP-12A/DBP-12MA/DBP-15A
satellites. In this way, the high energetic content of the low frequencies is limited to the
subwoofer and the satellite' s woofer act like a mid -woofer. As a consequence the
satellites built-in amplifier is not stressed by low frequency content.

1). Connect one side of signal cable at your mixer into Main Output Left/Right (with1/4"
Jack or XLR) and the other side of the cable into the Left/Mono Input (COMBO) of the
SWHP15A
DBP active subwoofers; with the second signal cable connect the Left/Mono Line
Output of the subwoofer (Stereo/Mono-Jack or XLR) to the Line input (COMBO) of the
active satellite (with Stereo - Jack or XLR).
2). Connect the power cord to mains.
3). Turn on your mixer first, then the active speaker cabinets.
MODEL

2011/65/EU
SERIAL
4). Turn up the volume control of the active speaker cabinets.
(3) ON OFF

FLAT 5). Use PFL function to get the proper input level for the mixer, and adjust the
(1)
(4) 0dB
AC INPUT Main Mix Level control to manipulate the output level.
MAX EQ -LOUDNESS
8

AC INPUT
INPUT LINK SIGNAL VOLUME 110-120V~50/60Hz
220-240V~50/60Hz (2)
(5) POWER
IN LIMIT
AC FUSE
110-120V: T6.3AL AC250V POWER
6). After use, turn off your active speaker cabinets first, then the mixer.
220-240V: T3.15AL AC250V
POWER CONSUMPTION:450W
Use only with a 250V fuse

(7) (8) (6) (9)

( 1 ) ON-OFF main power switch.

( 2 ) Input AC power socket with main fuse. LINE IN LINE IN

( 3 ) VOLUME main power amplifier control. LINE OUT LEFT/MONO


LINE OUT LEFT/MONO

( 4 ) LINE OUT at + 4dB on XLR connector. MAIN OUT LEFT MAIN OUT RIGHT

LINE IN LEFT/MONO LINE IN LEFT/MONO


( 5 ) LINE in at + 4dB on COMBO connector.

( 6 ) Ground lift switch.


+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

( 7 ) POWER, green LED, indicate ON status. 15

15
15

15
15

15
15

15
DSP

88
+48V

15 15 15 15 10

AS SUBWOOFER AS SUBWOOFER
( 8 ) SIGNAL/LIMIT, red LED, indicate ON status.

( 9 ) FLAT/LOUDNESS switch.
MIXER
11 8
SPEAKER/ENCLOSURE

QUICK START - ACTIVE SPEAKER CABINETS CONNECTIONS


-. PASSIVE FULL-RANGE: DBP-12/DBP-15
Active, one subwoofer and two satellite speakers.
This is a very popular combination, especially in small size clubs where there is no need 1). INPUT: Receive the signal coming from an external power amplifier.
for two subwoofers. (SPK +1/-1 connected; +2/-2 not connected).
2). THRU: Direct LINK to connect in parallel a second speaker cabinet
1). Connect one side of signal cable at your mixer into Main Output Left (with 1/4"Jack or (SPK +1/-1 connected; +2/-2 not connected).
LR) and the other side of the cable into the Left Input of the DBP active subwoofer. Repeat
for the RIGHT channel. With the second signal cable connect the Left Line Output of the
subwoofer (Stereo/Mono-Jack or XLR) to the Line input (COMBO) of the active satellite
(with Stereo-Jack or XLR). Repeat for the RIGHT channel.

2). Connect the power cord to mains. D BP-12


D BP-15
Power Handling: 250W RMS
Impedance: 8 ohms Power Handling: 300W RMS
3). Turn on your mixer first, then the active speaker cabinets. Max SPL: 118.5dB at 1mt Impedance: 8 ohms
Max SPL: 121dB at 1mt
MODEL
MODEL
4). Turn up the volume control of the active speaker cabinets. SERIAL
SERIAL

5). Use PFL function to get the proper input level for the mixer, and adjust the INPUT 2011/65/EU
THRU
Main Mix Level control to manipulate the output level. INPUT 2011/65/EU
THRU

6). After use, turn off your active speaker cabinets first, then the mixer.

(1) (2) (1) (2)

LINE IN
WIRE CONNECTIONS
LINE IN

-. For Passive Speaker Cabinets


LINE OUT LEFT LINE OUT RIGHT
Please only use the power connectors to make connections with other signal source
equipment for the passive speaker cabinets. The power connector has four terminals:
1+, 1-, 2+, 2-.
LINE IN LEFT MAIN OUT LEFT
+4 +4 +4 +4 PHANTOM
75Hz 75Hz 75Hz 75Hz 10 10 10 10 48V

DSP

88
+48V 1+
15 15 15 15

2-

1-
LINE IN RIGHT MAIN OUT RIGHT 15 15 15 15

15 15 15 15 10

2+

AS SUBWOOFER MIXER
In our cabinets, only 1+/1- are used to connect the Speaker+/Speaker-, and 2+/2- are not
used.

9 10

You might also like