Electrical 18-19 PDF
Electrical 18-19 PDF
DSR REPORT
Name Electrical Year 2018-2019
Rate In (Rs)
Item Description Rate Unit
13870 Chapter 1-1-10 Supplying & laying Rigid PVC conduit 25 mm Dia with necessary 85.00 Meter
0 accessories in RCC work/false ceiling/false flooring as per
specification No. WG-MA/CC, para no. 1.2.1
13870 Chapter 1-1-11 Supplying & erecting I.S.I. mark Rigid P.V.C. conduit 32 mm. 138.00 Meter
1 dia. with necessary accessories in wall/floor with chiselling
appropriately as per specification No: WG-MA/CC, para no. 1.2.1
13870 Chapter 1-1-12 Supplying & laying Rigid PVC conduit 16 SWG 32 mm Dia. with 115.00 Meter
2 necessary accessories in RCC work/false ceiling/false flooring as
per specification No. WG-MA/CC, para no. 1.2.1
13870 Chapter 1-1-13 Concealing of provided ISI mark G.I. pipe/H.G. screwed 59.00 Meter
3 conduit/PVC pipe in wall/floor/false ceiling complete as per
specification No:WG-PW/CW
Chapter 1-2 PVC Flexible/Rigid Conduits/Casing-n-capping/Under Floor
Trunking/Raceways and Box System (WG-MA/CON)
13870 Chapter 1-2-1 Supplying and erecting UPVC reinforced flexible conduit 20 mm in 71.00 Meter
4 dia. conforming to I.S. and approved make with required
number of couplings, PVC bushes, check nuts etc. complete.
13870 Chapter 1-2-2 Supplying and erecting UPVC reinforced flexible conduit 25 mm in 91.00 Meter
5 dia. conforming to I.S. and approved make with required
number of couplings, PVC bushes, check nuts etc. complete.
13870 Chapter 1-2-3 Supplying and erecting UPVC reinforced flexible conduit 31/32 105.00 Meter
6 mm in dia. conforming to I.S. and approved make with required
number of couplings, PVC bushes, check nuts etc. complete.
13870 Chapter 1-2-4 Supplying and erecting UPVC reinforced flexible conduit 38/40 140.00 Meter
7 mm in dia. conforming to I.S. and approved make with required
number of couplings, PVC bushes, check nuts etc. complete.
13870 Chapter 1-2-5 Supplying and erecting UPVC reinforced flexible conduit 50 mm in 177.00 Meter
8 dia. conforming to I.S. and approved make with required
number of couplings, PVC bushes, check nuts etc. complete.
13870 Chapter 1-2-6 Supplying and erecting rigid PVC conduit 20 mm dia. with PVC 64.00 Meter
9 accessories on wall / ceiling as per specification No: WG-MA/CON,
para no. 1.1.1
13871 Chapter 1-2-7 Supplying and erecting rigid PVC conduit 25 mm dia. with 73.00 Meter
0 PVC accessories on wall /ceiling as per specification No:
WG-MA/CON, para no. 1.1.1
13871 Chapter 1-2-8 Supplying and erecting rigid PVC conduit 32 mm dia. with 111.00 Meter
1 PVC accessories on wall / ceiling as per specification No:
WG-MA/CON, para no. 1.1.1
Rate In (Rs)
Item Description Rate Unit
13871 Chapter 1-2-9 Supplying and erecting PVC trunking (PVC casing-n-capping) of 32.00 Meter
2 size 20 mm with accessories on wall/ceiling as per specification
No: WG-MA/CON, para no. 1.1.2
13871 Chapter 1-2-10 Supplying and erecting PVC trunking (PVC casing-n-capping) of 34.00 Meter
3 size 25 mm with accessories on wall/ceiling as per specification
No: WG-MA/CON, para no. 1.1.2
13871 Chapter 1-2-11 Supplying and erecting PVC trunking (PVC casing-n-capping) of 41.00 Meter
4 size 32 mm with accessories on wall/ceiling as per specification
No: WG-MA/CON, para no. 1.1.2
13871 Chapter 1-2-12 Supplying and erecting PVC trunking (PVC casing-n-capping) of 61.00 Meter
5 size 40 mm with accessories on wall/ceiling as per specification
No: WG-MA/CON, para no. 1.1.2
13871 Chapter 1-2-13 Supplying and erecting PVC box trunking of size 50x16/20 76.00 Meter
6 mm. with accessories on wall/ceiling as per specification No:
WG-MA/BOX, para no. 1.1.2
13871 Chapter 1-2-14 Supplying and erecting PVC box trunking of size 50x50 mm. 127.00 Meter
7 with accessories on wall/ceiling as per specification No:
WG-MA/BOX, para no. 1.1.2
13871 Chapter 1-2-15 Supplying and erecting PVC box trunking of size 75x50 mm. 292.00 Meter
8 with accessories on wall/ceiling as per specification No:
WG-MA/BOX, para no. 1.1.2
13871 Chapter 1-2-16 Supplying and erecting PVC box trunking of size 75x75 mm. 353.00 Meter
9 with accessories on wall/ceiling as per specification No:
WG-MA/BOX, para no. 1.1.2
13872 Chapter 1-2-17 Supplying and erecting PVC box trunking of size 100x50 mm. 451.00 Meter
0 with accessories on wall/ceiling as per specification No:
WG-MA/BOX para no. 1.1.2
13872 Chapter 1-2-18 Supplying and erecting PVC slotted box trunking of size 25x25 53.00 Meter
1 mm. with accessories on wall/ceiling as per specification No:
WG-MA/SLBOX, para no. 1.1.2
13872 Chapter 1-2-19 Supplying and erecting PVC slotted box trunking of size 45x30 98.00 Meter
2 mm. with accessories on wall/ceiling as per specification No:
WG-MA/SLBOX, para no. 1.1.2
13872 Chapter 1-2-20 Supplying and erecting PVC slotted box trunking of size 60x45 139.00 Meter
3 mm. with accessories on wall/ceiling as per specification No:
WG-MA/SLBOX, para no. 1.1.2
13872 Chapter 1-2-21 Supplying and erecting PVC slotted box trunking of size 75x75 187.00 Meter
4 mm. with accessories on wall/ceiling as per specification No:
WG-MA/SLBOX, para no. 1.1.2
Electrical - 2018-2019 - 01/04/2018 - Page 3 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13874 Chapter 1-3-10 Supplying & erecting mains with 2x10 sq.mm F.R.L.S copper PVC 188.00 Meter
8 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13874 Chapter 1-3-11 Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC 71.00 Meter
9 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-12 Supplying & erecting mains with 3x2.5 sq.mm F.R. L.S copper PVC 76.00 Meter
0 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-13 Supplying & erecting mains with 3x4 sq.mm F.R copper PVC 100.00 Meter
1 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-14 Supplying & erecting mains with 3x4 sq.mm F.R L.S copper PVC 108.00 Meter
2 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-15 Supplying & erecting mains with 3x6 sq.mm F.R copper PVC 143.00 Meter
3 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-16 Supplying & erecting mains with 3x6 sq.mm F.R.L.S copper PVC 154.00 Meter
4 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-17 Supplying & erecting mains with 3x10 sq.mm F.R copper PVC 241.00 Meter
5 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-18 Supplying & erecting mains with 3x10 sq.mm F.R.L.S copper PVC 280.00 Meter
6 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-19 Supplying & erecting mains with 4x16 sq.mm F.R copper PVC 491.00 Meter
7 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-20 Supplying & erecting mains with 4x16 sq.mm F.R L.S copper PVC 537.00 Meter
8 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13875 Chapter 1-3-21 Supplying & erecting mains with 4x25 sq.mm F.R copper PVC 931.00 Meter
9 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
13876 Chapter 1-3-22 Supplying & erecting mains with 4x25 sq.mm F.R.L.S copper PVC 1,091.00 Meter
0 insulated wire laid in provided conduit/trunking/inside pole/Bus
bars or any other places as per specification No: WG-MA/BW
Electrical - 2018-2019 - 01/04/2018 - Page 6 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13878 Chapter 1-5-7 Supplying & erecting mains with 2x6 sq.mm. F.R. copper wire, in 261.00 Meter
1 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 4 sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13878 Chapter 1-5-8 Supplying & erecting mains with 2x6 sq.mm. F.R.L.S copper wire, 265.00 Meter
2 in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 4 sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
13878 Chapter 1-5-9 Supplying & erecting mains with 2x10 sq.mm.F.R copper wire, in 338.00 Meter
3 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 6 sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13878 Chapter 1-5-10 Supplying & erecting mains with 2x10 sq.mm.F.R.L.S copper wire, 350.00 Meter
4 in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 6sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
13878 Chapter 1-5-11 Supplying & erecting mains with 3x4 sq.mm. F.R.copper wire, in 260.00 Meter
5 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13878 Chapter 1-5-12 Supplying & erecting mains with 3x4 sq.mm. F.R.L.S copper wire, 269.00 Meter
6 in 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 2.5sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
13878 Chapter 1-5-13 Supplying & erecting mains with 3x6 sq.mm. F.R.copper wire, in 311.00 Meter
7 16gauge 20 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 4sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13878 Chapter 1-5-14 Supplying & erecting mains with 3x6 sq.mm. F.R.L.S copper wire, 324.00 Meter
8 in 16gauge 20 mm dia.Rigid Steel conduit, with continuous GI
earth wire of 4sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
13878 Chapter 1-5-15 Supplying & erecting mains with 3x10 sq.mm.F.R copper wire, in 456.00 Meter
9 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 6sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-16 Supplying & erecting mains with 3x10 sq.mm.F.R.L.S copper wire, 484.00 Meter
0 in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 6sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
Electrical - 2018-2019 - 01/04/2018 - Page 9 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13879 Chapter 1-5-17 Supplying & erecting mains with 4x4 sq.mm. F.R copper wire, in 330.00 Meter
1 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 2.5sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-18 Supplying & erecting mains with 4x4 sq.mm. F.R.L.S copper wire, 342.00 Meter
2 in 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 2.5 sq.mm as per specification No: WG-MA/MC, para
no. 1.4.3
13879 Chapter 1-5-19 Supplying & erecting mains with 4x6 sq.mm.F.R copper wire, in 396.00 Meter
3 16gauge 25 mm dia.Rigid Steel conduit, with continuous GI earth
wire of 4sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-20 Supplying & erecting mains with 4x6 sq.mm.F.R L.S copper wire, in 414.00 Meter
4 16gauge 25 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 4sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-21 Supplying & erecting mains with 4x10 sq.mm.F.R copper wire, in 565.00 Meter
5 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 6sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-22 Supplying & erecting mains with 4x10 sq.mm.F.R.L.S copper wire, 621.00 Meter
6 in 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI
earth wire of 6sq.mm. as per specification No: WG-MA/MC, para
no. 1.4.3
13879 Chapter 1-5-23 Supplying & erecting mains with 6x6 sq.mm.F.R copper wire, in 487.00 Meter
7 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 4sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
13879 Chapter 1-5-24 Supplying & erecting mains with 6x6 sq.mm.F.R.L.S copper wire, in 542.00 Meter
8 16gauge 32 mm dia. Rigid Steel conduit, with continuous GI earth
wire of 4sq.mm. as per specification No: WG-MA/MC, para no.
1.4.3
Chapter 1-6 Mains in PVC Conduit (WG-MA/PC)
13879 Chapter 1-6-1 Supplying & erecting mains 2x1.5 sq.mm.and earth wire 1.5 104.00 Meter
9 sq.mm FR PVC copper wire, in rigid PVC conduit min. 20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-2 Supplying & erecting mains with 2x1.5 sq.mm.and earth wire 1.5 106.00 Meter
0 sq.mm FRLS PVC copper wire, in rigid PVC conduit min. 20mm dia
as per specification No: WG-MA/PC, para no. 1.4.1
Rate In (Rs)
Item Description Rate Unit
13880 Chapter 1-6-3 Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 118.00 Meter
1 sq.mm FR PVC copper wire, in rigid PVC conduit min. 20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-4 Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 123.00 Meter
2 sq.mm FRLS PVC copper wire in rigid PVC conduit min. 20mm dia.
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-5 Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 142.00 Meter
3 sq.mm FR PVC copper wire in rigid PVC conduit min .20mm dia,as
per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-6 Supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 148.00 Meter
4 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-7 Supplying & erecting mains with 2x6 sq.mm.and earth wire 4 179.00 Meter
5 sq.mm FR PVC copper wire, in rigid PVC conduit min.20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-8 Supplying & erecting mains with 2x6 sq.mm.and earth wire 4 187.00 Meter
6 sq.mm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-9 Supplying & erecting mains with 2x10 sq.mm.and earth wire 6 265.00 Meter
7 sqmm FR PVC copper wire, in rigid PVC conduit min. 25 mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-10 Supplying & erecting mains with 2x10 sq.mm.and earth wire 6 294.00 Meter
8 sq.mm FRLS PVC copper wire, in rigid PVC conduit min. 25mm
dia, as per specification No: WG-MA/PC, para no. 1.4.1
13880 Chapter 1-6-11 Supplying & erecting mains with 3x4 sq.mm.and earth wire 2.5 180.00 Meter
9 sq.mm FR PVC copper wire, in rigid PVC conduit min.20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13881 Chapter 1-6-12 Supplying & erecting mains with 3x4 sq.mm.and earth wire 2.5 189.00 Meter
0 sq.mm FRLS PVC copper wire, in rigid PVC conduit min.20mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13881 Chapter 1-6-13 Supplying & erecting mains with 3x6 sq.mm.and earth wire 4 231.00 Meter
1 sq.mm FR PVC copper wire, in rigid PVC conduit min. 25mm dia,
as per specification No: WG-MA/PC, para no. 1.4.1
13881 Chapter 1-6-14 Supplying & erecting mains with 3x6 sq.mm.and earth wire 4 245.00 Meter
2 sq.mm FRLS PVC copper wire, in rigid PVC conduit min. 25 mm
dia, as per specification No: WG-MA/PC, para no. 1.4.1
13881 Chapter 1-6-15 Supplying & erecting mains with 3x10 sq.mm.and earth wire 6 338.00 Meter
3 sq.mm FR PVC copper wire, in rigid PVC conduit min. 25mm dia.
as per specification No: WG-MA/PC, para no. 1.4.1
Electrical - 2018-2019 - 01/04/2018 - Page 11 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13884 Chapter 1-8-4 Supplying and erecting modular type bell-push with indicator 2 113.00 Each
4 modules 6A / 10A ISI mark approved make duly erected on
provided plate and box with wiring connections complete.
13884 Chapter 1-8-5 Supplying and erecting modular type Two way switch 6A / 10A (2 99.00 Each
5 Module) ISI mark, approved make, duly erected on provided plate
and box with wiring connections complete.
13884 Chapter 1-8-6 Supplying and erecting modular type switch 16 / 20 A with 126.00 Each
6 indicator, ISI mark, approved make duly erected on provided plate
and box with wiring connections complete.
13884 Chapter 1-8-7 Supplying and erecting modular type switch one way 16 / 20 A, ISI 130.00 Each
7 mark, approved make duly erected on provided plate and box with
wiring connections complete with neon indicator.
13884 Chapter 1-8-8 Supplying and erecting modular type D.P. switch 32A with indicator 164.00 Each
8 ISI mark approved make duly erected on provided plate and box
with wiring connections complete.
13884 Chapter 1-8-9 Supplying and erecting modular type 32A, DP key tag switch with 328.00 Each
9 KEY TAG ISI mark approved make duly erected on provided plate
and box with wiring connections complete.
13885 Chapter 1-8-10 Supplying and erecting modular type 3 pin 6A multi socket with 104.00 Each
0 safety shutter ISI mark approved make duly erected on provided
plate and box with wiring connections complete.
13885 Chapter 1-8-11 Supplying and erecting modular type 3 pin 6 / 16A multi socket 149.00 Each
1 with safety shutter ISI mark approved make duly erected on
provided plate and box with wiring connections complete.
13885 Chapter 1-8-12 Supplying and erecting modular type indicator lamp ISI mark 57.00 Each
2 approved make duly erected on provided plate and box with wiring
connections complete.
13885 Chapter 1-8-13 Supplying and erecting modular type 6 / 16A fuse unit ISI mark 84.00 Each
3 approved make duly erected on provided plate and box with wiring
connections complete.
13885 Chapter 1-8-14 Supplying and erecting modular type T.V. socket single outlet ISI 80.00 Each
4 mark approved make duly erected on provided plate and box with
wiring connections complete.
13885 Chapter 1-8-15 Supplying and erecting modular type telephone socket one gang 80.00 Each
5 with safety shutter ISI mark approved make duly erected on
provided plate and box with wiring connections complete.
13885 Chapter 1-8-16 Supplying and erecting modular type telephone socket two gang 95.00 Each
6 with safety shutter ISI mark approved make duly erected on
provided plate and box with wiring connections complete.
Electrical - 2018-2019 - 01/04/2018 - Page 15 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13887 Chapter 1-8-30 Supplying and erecting PVC Surface modular switch box with 171.00 Each
0 double mounting plate for 4 module duly erected in an approved
manner.
13887 Chapter 1-8-31 Supplying and erecting PVC Surface modular switch box with 229.00 Each
1 double mounting plate for 6 module duly erected in an approved
manner.
13887 Chapter 1-8-32 Supplying and erecting PVC Surface modular switch box with 289.00 Each
2 double mounting & front plate for 8 module complete duly
connected.
13887 Chapter 1-8-33 Supplying and erecting PVC Surface modular switch box with 374.00 Each
3 double mounting plate for 12 module duly erected in an approved
manner.
13887 Chapter 1-8-34 Supplying and erecting PVC Surface modular switch box with 411.00 Each
4 double mounting plate for 16 / 18 module duly erected in an
approved manner.
13887 Chapter 1-8-35 Supplying and erecting unbreakable concealed type modular 210.00 Each
5 switch box with double mounting plate for 1 module duly erected
flush to wall with required chiseling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13887 Chapter 1-8-36 Supplying and erecting unbreakable concealed type modular 210.00 Each
6 switch box with double mounting plate for 2 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13887 Chapter 1-8-37 Supplying and erecting unbreakable concealed type modular 241.00 Each
7 switch box with double mounting plate for 3 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13887 Chapter 1-8-38 Supplying and erecting unbreakable concealed type modular 271.00 Each
8 switch box with double mounting plate for 4 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13887 Chapter 1-8-39 Supplying and erecting unbreakable concealed type modular 364.00 Each
9 switch box with double mounting plate for 6 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
Electrical - 2018-2019 - 01/04/2018 - Page 17 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13888 Chapter 1-8-40 Supplying and erecting unbreakable concealed type modular 430.00 Each
0 switch box with double mounting plate for 8 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13888 Chapter 1-8-41 Supplying and erecting unbreakable concealed type modular 477.00 Each
1 switch box with double mounting plate for 12 module duly erected
flush to wall with required chiselling and finishing with cement
morter / POP as per required to match the background in an
approved manner.
13888 Chapter 1-8-42 Supplying and erecting unbreakable concealed type modular 521.00 Each
2 switch box with double mounting plate for 16 / 18 module duly
erected flush to wall with required chiselling and finishing with
cement morter / POP as per required to match the background in
an approved manner.
13888 Chapter 1-8-43 Supplying and erecting White Footlight with 4 modules concealed 413.00 Each
3 modular box and lamp holder with cover complete erected on
wall /flush to wall with necessary chiselling in wall and finishing
with cement and morter / PoP as per required and duly connected
in an approved manner.
13888 Chapter 1-8-44 Supplying and erecting White Footlight with 8 modules concealed 503.00 Each
4 modular box and lamp holder with cover complete erected on
wall /flush to wall with necessary chiselling in wall and finishing
with cement and morter / PoP as per required and duly connected
in an approved manner.
13888 Chapter 1-8-45 Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 333.00 Each
5 module for AC unit on provided box complete & duly concealed
with necessary material and connected.
13888 Chapter 1-8-46 Supplying and erecting 6 to 32 A SPMCB suitable to fix in 1 174.00 Each
6 module of modular switch in provided box complete & duly
concealed with necessary material and connected.
13888 Chapter 1-8-47 Supplying and erecting 16 to 32 A DPMCB suitable to fix in 2 219.00 Each
7 module of modular switch in provided box complete & duly
concealed with necessary material and connected.
13888 Chapter 1-8-48 Supplying and erecting PVC Surface modular double mounting 66.00 Each
8 plate 1 module complete duly erected in an approved manner.
13888 Chapter 1-8-49 Supplying and erecting PVC Surface modular double mounting 66.00 Each
9 plate 2 module complete duly erected in an approved manner.
Rate In (Rs)
Item Description Rate Unit
13889 Chapter 1-8-50 Supplying and erecting PVC Surface modular double mounting 73.00 Each
0 plate 3 module complete duly erected in an approved manner.
13889 Chapter 1-8-51 Supplying and erecting PVC Surface modular double mounting 79.00 Each
1 plate 4 module complete duly erected in an approved manner.
13889 Chapter 1-8-52 Supplying and erecting PVC Surface modular double mounting 122.00 Each
2 plate 6 module complete duly erected in an approved manner.
13889 Chapter 1-8-53 Supplying and erecting PVC Surface modular double mounting 143.00 Each
3 plate 8 module complete duly erected in an approved manner.
13889 Chapter 1-8-54 Supplying and erecting PVC Surface modular double mounting 183.00 Each
4 plate 12 module complete duly erected in an approved manner.
13889 Chapter 1-8-55 Supplying and erecting PVC Surface modular double mounting 206.00 Each
5 plate 16/18 module complete duly erected in an approved manner.
13889 Chapter 1-8-56 Supplying and erecting Modular type 5 pin socket with safety 168.00 Each
6 shutters 3 module socket 6A. 240V AC supply, ISI approved and
marked make duly erected on provided plate and box with wiring
connections complete duly erected in approved manner.
13889 Chapter 1-8-57 Supplying and erecting Modular safety power strip with one 1,127.00 Each
7 modular switch16A and three sockets each 13A combination with
overload and surge protection unit on double mounting plate
complete duly erected in an approved manner.
13889 Chapter 1-8-58 Supplying and erecting Modular switch with LED indicator available 116.00 Each
8 to connect in a switch board to glow LED when connected load is
off, on provided double mounting plate complete duly erected in an
approved manner.
13889 Chapter 1-8-59 Supplying and erecting Modular type USB Charger socket of 1 578.00 Each
9 Module with nominal output voltage of 5 VDC + 5/- 5% and
Nominal output current of 5 V - 750 mA , ISI mark approved make
duly erected on provided plate and box with wiring connections
complete.
Chapter 1-9 Point Wiring (WG-PW)
13890 Chapter 1-9-1 Point wiring for light/fan/bell in 20 mm metal conduit with 1.5 672.00 point
0 sq.mm (2+1E) FR grade copper wire,flush type switch, earthing
and required accessories as per specification No: WG-PW/SW
13890 Chapter 1-9-2 Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 609.00 point
1 sq.mm (2+1E) FRLS grade copper wire,flush type switch, earthing
and required accessories as per specification No: WG-PW/SW
Rate In (Rs)
Item Description Rate Unit
13890 Chapter 1-9-3 Point wiring for independent plug in 20 mm metal conduit with 1.5 713.00 point
2 sq.mm (2+1E) FR grade copper wire,flush type switch, earthing
and required accessories as per specification No: WG-PW/SW
13890 Chapter 1-9-4 Point wiring for independent plug in 20 mm metal conduit with 1.5 648.00 point
3 sq.mm (2+1E) FRLS grade copper wire,flush type switch, earthing
and required accessories as per specification No: WG-PW/SW
13890 Chapter 1-9-5 Point wiring for light/fan/bell in 20 mm rigid PVC conduit with 1.5 375.00 point
4 sq.mm (2+1E) FR grade copper wire,flush type switch, earthing
and required accessories as per specification No: WG-PW/SW
13890 Chapter 1-9-6 Point wiring for light/fan/bell in 20 mm rigid PVC conduit with 1.5 382.00 point
5 sq.mm (2+1E) FRLS grade Copper wire with flush type switch and
required accessories as per specification No: WG-PW/SW
13890 Chapter 1-9-7 Point wiring for independent plug in 20 mm rigid PVC conduit with 398.00 point
6 1.5 sq.mm (2+1E) FR grade copper wire,flush type switch,
earthing and required accessories as per specification No:
WG-PW/SW
13890 Chapter 1-9-8 Point wiring for independent plug in 20 mm rigid PVC conduit with 408.00 point
7 1.5 sq.mm (2+1E) FRLS grade copper wire,flush type switch,
earthing and required accessories as per specification No:
WG-PW/SW
13890 Chapter 1-9-9 Point wiring for light/fan/bell concealed type in min 20 mm PVC 554.00 point
8 conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular
type switch, earthing and required accessories as per
specification No: WG-PW/CW
13890 Chapter 1-9-10 Supplying and Drawing of 2x1.5 sq.mm. FR grade copper wires 351.00 point
9 with 1.5 sqmm earth wire in provided concealed pipes for
concealed type light/fan/bell point wiring and terminating on
modular accessories in box for point wiring for light/fan/bell as per
specification No: WG-PW/CW
13891 Chapter 1-9-11 Point wiring for independent plug, concealed type in min 20 mm 602.00 point
0 PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires,
modular type switch and socket, earthing and required
accessories as per specification No WG-PW/SW
13891 Chapter 1-9-12 Supplying and drawing of 2x1.5 sq.mm. FR grade copper wires 479.00 point
1 with 1.5 sqmm earth wire in provided concealed pipes and
terminating on modular accessories in box for point wiring for
independent plug as per specification No WG-PW/SW
13891 Chapter 1-9-13 Wiring for plug on board with Switch socket with copper wiring 93.00 point
2 and earthing as per specification No:WG-PW/SW
Rate In (Rs)
Item Description Rate Unit
13891 Chapter 1-9-14 Wiring for plug on board with Switch socket concealed type and 454.00 point
3 copper wiring, earthing and with modular accessories as per
specification No: WG-PW/CW
13891 Chapter 1-9-15 Point wiring for light/fan/bell /exhaust fan Hybrid type (Surface 493.00 point
4 type under false ceiling and concealed type for drops & switch
boards on walls) in min 20 mm PVC conduit / casing n caping with
1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch,
earthing and required accessories as per specification No:
WG-PW/CW
13891 Chapter 1-9-16 Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm 272.00 point
5 (2+1E) FR grade copper wire, flush type switch,earthing and
required accessories as per specification No: WG-PW/SW
13891 Chapter 1-9-17 Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm 279.00 point
6 (2+1E) FRLS grade copper wire, flush type switch,earthing and
required accessories as per specification No: WG-PW/SW
13891 Chapter 1-9-18 Point wiring for independent plug in PVC trunking (casing-capping) 323.00 point
7 with 1.5 sq.m (2+1E) FR grade copper wire with flush type switch
and required accessories as per specification No: WG-PW/SW
13891 Chapter 1-9-19 Point wiring for independent plug in PVC trunking (casing-capping) 333.00 point
8 with 1.5 sq.mm FRLS grade copper wire, flush type switch,earthing
and required accessories as per specification No: WG-PW/SW
13891 Chapter 1-9-20 Concealing provided M.S./ PVC switch box in wall with finishing in 50.00 Each
9 an approved manner as per specification No: WG-PW/CW
13892 Chapter 1-9-22 Refilling the holes for dismantled point wiring with cement mortar 28.00 point
0 & finishing in an approved manner.
13892 Chapter 1-9-23 Secondary Point wiring for additional light/ Bell point, concealed 156.00 point
1 type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLS
grade copper wires with required accessories as per specification
No: WG-PW/CW
13892 Chapter 1-9-24 Secondary Point wiring for additional light/ Bell point in PVC 152.00 point
2 trunking (casing-capping) with 1.5 sq.m (2+1E) FR / FRLS grade
copper wire with required accessories as per specification No:
WG-PW/SW
13892 Chapter 1-9-25 Secondary Point wiring for additional light/ Bell point in min 20 266.00 point
3 mm metal conduit with 1.5 sq.m (2+1E) FR/FRLS grade copper
wire with required accessories as per specification No: WG-PW/SW
Chapter 1-10 Telephone Wiring(WG-TW/TW)
Rate In (Rs)
Item Description Rate Unit
13892 Chapter 1-10-2 Supplying & erecting telephone cable 2 pair with 0.5 mm dia. laid 19.00 Meter
4 in provided PVC casing / conduit as per specification No. WG-TW
13892 Chapter 1-10-3 Supplying & erecting telephone cable 3 pair with 0.5 mm dia. laid 24.00 Meter
5 in provided PVC casing / conduit as per specification No. WG-TW
13892 Chapter 1-10-4 Supplying & erecting telephone cable 4 pair with 0.5 mm dia. laid 31.00 Meter
6 in provided PVC casing / conduit as per specification No. WG-TW
13892 Chapter 1-10-5 Supplying & erecting telephone cable 5 pair with 0.5 mm dia. laid 40.00 Meter
7 in provided PVC casing / conduit as per specification No. WG-TW
13892 Chapter 1-10-6 Supplying & erecting telephone cable 10 pair with 0.5 mm dia. laid 66.00 Meter
8 in provided PVC casing / conduit as per specification No. WG-TW
13892 Chapter 1-10-7 Supplying & erecting telephone cable 20 pair with 0.5 mm dia. laid 119.00 Meter
9 in provided PVC casing / conduit as per specification No. WG-TW
13893 Chapter 1-10-8 Supplying & erecting telephone cable 50 pair with 0.5 mm dia. laid 286.00 Meter
0 in provided PVC casing / conduit as per specification No. WG-TW
13893 Chapter 1-10-9 Supplying & erecting telephone cable 100 pair with 0.5 mm dia. 551.00 Meter
1 laid in provided PVC casing / conduit as per specification No.
WG-TW
13893 Chapter Supplying & erecting Jelly filled unarmoured Telephone Cable 10 96.00 Meter
2 1-10-10 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per
specification No. WG-TW
13893 Chapter Supplying & erecting Jelly filled unarmoured Telephone Cable 20 153.00 Meter
3 1-10-11 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per
specification No. WG-TW
13893 Chapter Supplying & erecting Jelly filled unarmoured Telephone Cable 50 339.00 Meter
4 1-10-12 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per
specification No. WG-TW
13893 Chapter Supplying & erecting Jelly filled unarmoured Telephone Cable 100 613.00 Meter
5 1-10-13 pair with 0.5 mm dia. laid in provided PVC casing / conduit as per
specification No. WG-TW
13893 Chapter Supplying & erecting Jelly filled armoured telephone cable 10 pair 126.00 Meter
6 1-10-14 with 0.5 mm dia. laid in provided trench as per specification No.
WG-TW
13893 Chapter Supplying & erecting Jelly filled armoured telephone cable 20 pair 170.00 Meter
7 1-10-15 with 0.5 mm dia. laid in provided trench as per specification No.
WG-TW
13893 Chapter Supplying & erecting Jelly filled armoured telephone cable 50 pair 364.00 Meter
8 1-10-16 with 0.5 mm dia. laid in provided trench as per specification No.
WG-TW
Electrical - 2018-2019 - 01/04/2018 - Page 22 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
WG-TW
13893 Chapter Supplying & erecting Jelly filled armoured telephone cable 100 pair 617.00 Meter
9 1-10-17 with 0.5 mm dia. laid in provided trench as per specification No.
WG-TW
13894 Chapter Supplying & erecting Jumper wire with 0.5 mm dia as per 18.00 Meter
0 1-10-18 specification No. WG-TW
13894 Chapter Supplying & installing Co-axial cable low voltage grade RG-11 as 61.00 Meter
1 1-10-19 per specification No. WG-TW
Chapter 1-11 Telephone Accessories (WG-TW/TA)
13894 Chapter 1-11-1 Supplying, erecting & commissioning Main Distribution Frame 1,844.00 Each
2 (MDF) Box 50x50 pairs as per specification No. WG-TW
13894 Chapter 1-11-2 Supplying, erecting & commissioning MDF Box 60 x 60 pairs as 1,982.00 Each
3 per specification No. WG-TW
13894 Chapter 1-11-3 Supplying, erecting & commissioning MDF Box 100 x 100 pairs as 3,013.00 Each
4 per specification No. WG-TW
13894 Chapter 1-11-4 Supplying, erecting & commissioning MDF Box 150 x 150 pairs as 4,234.00 Each
5 per specification No. WG-TW
13894 Chapter 1-11-5 Supplying, erecting & commissioning MDF Box 200 x 200 pairs as 6,178.00 Each
6 per specification No. WG-TW
13894 Chapter 1-11-6 Supplying, erecting & commissioning MDF Box 250 x 250 pairs as 7,824.00 Each
7 per specification No. WG-TW
13894 Chapter 1-11-7 Supplying, erecting & commissioning MDF Box 300 x 300 pairs as 8,928.00 Each
8 per specification No. WG-TW
13894 Chapter 1-11-8 Supplying, erecting & commissioning MDF Box 400 x 400 pairs as 12,857.00 Each
9 per specification No. WG-TW
13895 Chapter 1-11-9 Supplying, erecting & commissioning MDF Box 500 x 500 pairs as 15,986.00 Each
0 per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning MDF Box 600 x 600 pairs as 18,839.00 Each
1 1-11-10 per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning MDF Box 800 x 800 pairs as 28,120.00 Each
2 1-11-11 per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 10 589.00 Each
3 1-11-12 pairs as per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 20 706.00 Each
4 1-11-13 pairs as per specification No. WG-TW
Rate In (Rs)
Item Description Rate Unit
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 30 947.00 Each
5 1-11-14 pairs as per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 40 1,023.00 Each
6 1-11-15 pairs as per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 50 1,271.00 Each
7 1-11-16 pairs as per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 60 1,346.00 Each
8 1-11-17 pairs as per specification No. WG-TW
13895 Chapter Supplying, erecting & commissioning Junction box suitable for 100 1,942.00 Each
9 1-11-18 pairs as per specification No. WG-TW
13896 Chapter Supplying, erecting & commissioning Junction box suitable for 150 2,420.00 Each
0 1-11-19 pairs as per specification No. WG-TW
13896 Chapter Supplying, erecting & commissioning Krone module of 10 pairs as 313.00 Each
1 1-11-20 per specification No. WG-TW
13896 Chapter Supplying & erecting Over Voltage protection Magazine suitable for 326.00 Each
2 1-11-21 10 pair as per specification No. WG-TW
13896 Chapter Supplying & erecting Rosette box RJ type Bakelite box on wall with 103.00 Each
3 1-11-22 LED indication duly connected as per specification No. WG-TW
13896 Chapter Supplying and erecting Broadband splitter unit with 1 input & 2 out 236.00 Each
4 1-11-23 put RJ 11 female connectors.
13896 Chapter Supplying, installing, testing & commissioning analogue type 13,176.00 Per Job
5 1-11-24 EPABX of 3 x 8 extension complete.
13896 Chapter Supplying, installing, testing & commissioning analogue type 14,458.00 Per Job
6 1-11-25 EPABX of 3 x 8 extension complete with CLI and Voice DISA
(Direct inward station access) as per specification No. WG-TW.
13896 Chapter Supplying, installing, testing & commissioning Digital (Hybrid) type 24,066.00 Per Job
7 1-11-26 EPABX of 3 x 8(2 Digital+6 Analogue) extensions complete.
13896 Chapter Supplying, installing, testing & commissioning Digital (Hybrid) type 30,470.00 Per Job
8 1-11-27 EPABX of 4 x 12(2 Digital+10 Analogue) extension complete.
13896 Chapter Supplying, installing, testing & commissioning Digital (Hybrid) type 37,516.00 Per Job
9 1-11-28 EPABX of 6 x 16(2 Digital+14 Analogue) extension complete.
13897 Chapter Supplying and installing, testing & commissioning of Digital 51,165.00 Per Job
0 1-11-29 (Hybrid) type EPABX of 8 x 20 (4 Digital+ 16 analog) extensions
suitable upto 120 extensions
13897 Chapter Supplying, installing, testing & commissioning Internet protocol 24,779.00 Per Job
1 1-11-30 digital type EPABX for 10 IP extensions complete.
Electrical - 2018-2019 - 01/04/2018 - Page 24 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13897 Chapter Supplying, installing, testing & commissioning approved type Push 689.00 Each
2 1-11-31 button telephone instrument desk top/wall mount unit as per
specification in approved manner
13897 Chapter Supplying, installing, testing & commissioning approved type Push 862.00 Each
3 1-11-32 button telephone instrument desk top/wall mount with caller ID
unit as per specification in approved manner
13897 Chapter Supplying, installing, testing & commissioning approved type 5,972.00 Each
4 1-11-33 Digital key telephone / IP telephone instrument as per specification
in approved manner.
Chapter 1-12 Computer Cabling (WG-COC)
13897 Chapter 1-12-1 Supplying & installing UTP networking Cat-6 cable suitable for 41.00 Meter
5 LAN / WAN Computer net-working as per specification No.
WG-COC/NC
13897 Chapter 1-12-2 Supplying and fixing Cat-6 LSZH cable suitable for LAN / WAN as 48.00 Meter
6 per specification in approved manner
13897 Chapter 1-12-3 Supplying & installing UTP networking Cat-6+ cable suitable for 64.00 Meter
7 LAN / WAN Computer net-working as per specification no.
WG-COC/NC
13897 Chapter 1-12-4 Supplying and fixing Cat-6A LSZH cable suitable for LAN / WAN as 68.00 Meter
8 per specification in approved manner
13897 Chapter 1-12-5 Supplying and fixing Cat-6 STP cable suitable for LAN / WAN as per 83.00 Meter
9 specification in approved manner
13898 Chapter 1-12-6 Supplying and fixing 1 meter length, UTP Patch cord of Cat 6 type 203.00 Each
0 in position as per specification No. WG-COC/PC
13898 Chapter 1-12-7 Supplying and fixing 3 meter length, UTP Patch cord of Cat 6 type 281.00 Each
1 in position as per specification No. WG-COC/PC
13898 Chapter 1-12-8 Supplying and erecting FR grade, PVC armoured multimode 182.00 Meter
2 armoured multimode Optical Fibre Cable with 6 fibres, with core
dia 50/125 µm (OM3) suitable for 1 GBps ethernet distance at 850
nm of wavelength, on wall/ceiling or laid in provided pipe/trench as
per specification No. WG-COC/OFC LSZH
13898 Chapter 1-12-9 Supplying and erecting LSZH armoured multimode Optical Fibre 267.00 Meter
3 Cable with 12 fibres, with core dia 50/125 µm (OM3), suitable for
1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling
or laid in provided pipe/trench as per specification No.
WG-COC/OFC
Rate In (Rs)
Item Description Rate Unit
13898 Chapter Supplying and erecting LSZH armoured multimode Optical Fibre 404.00 Meter
4 1-12-10 Cable with 24 fibres, with core dia 50/125 µm (OM3), suitable for
1 GBps ethernet distance at 850 nm of wavelength, on wall/ceiling
or laid in provided pipe/trench as per specification No.
WG-COC/OFC
13898 Chapter Supplying and erecting LSZH armoured multimode Optical Fibre 1,008.00 Meter
5 1-12-11 Cable with 6 fibres, with core dia 50/125 µm (OM4) suitable for 1
GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or
laid in provided pipe/trench as per specification No. WG-COC/OFC
13898 Chapter Supplying and erecting LSZH armoured multimode Optical Fibre 1,672.00 Meter
6 1-12-12 Cable with 12 fibres, with core dia 50/125 µm (OM4) suitable for 1
GBps ethernet distance at 850 nm of wavelength, on wall/ceiling or
laid in provided pipe/trench as per specification No. WG-COC/OFC
13898 Chapter Supplying and erecting LSZH armoured multimode Optical Fibre 2,855.00 Meter
7 1-12-13 Cable with 24 fibres, with core dia 50/125 µm (OM4) as per
specification in approved manner
13898 Chapter Supplying and plugging FRLS duplex 3 meter length, Fibre Patch 2,206.00 Each
8 1-12-14 cord LC-SC MM(50) OM3 LSZH DUPLEX complete as per
specification No. WG-COC/FPC
13898 Chapter Supplying and plugging FRLS duplex 3 meter length, Fibre Patch 2,525.00 Each
9 1-12-15 cord LC-SC MM(50) OM4 LSZH DUPLEX complete as per
specification No. WG-COC/FPC
13899 Chapter Supplying and plugging FRLS duplex 3 meter length, Fibre Patch 2,659.00 Each
0 1-12-16 cord LC-LC MM(50) OM3 LSZH DUPLEX complete as per
specification No. WG-COC/FPC
13899 Chapter Supplying and plugging FRLS duplex 3 meter length, Fibre Patch 3,916.00 Each
1 1-12-17 cord LC-LC MM(50) OM4 LSZH DUPLEX complete as per
specification No. WG-COC/FPC
13899 Chapter Supplying and fixing 2 meter length, UTP Patch cord of Cat 6 type 241.00 Each
2 1-12-18 in position as per specification No. WG-COC/PC
Chapter 1-13 Networking Components (WG- NWC)
13899 Chapter 1-13-1 Supplying, fixing, and configuring Web Smart Power over Ethernet 43,461.00 Each
3 Switch of 24 Ports on provided rack or as directed as per
specification No. WG-NWC/ENS
13899 Chapter 1-13-2 Supplying, fixing, and configuring Managed L2 Power over Ethernet 1,02,956.00 Each
4 Switch of 20 Ports + 4G Combo Port as per specification in
approved manner
Rate In (Rs)
Item Description Rate Unit
13899 Chapter 1-13-3 Supplying, fixing, and configuring 589Watt Redundant Power 73,780.00 Each
5 Supply system as per specification in approved manner
13899 Chapter 1-13-4 Supplying, fixing, and configuring Ethernet Managed Ethernet 27,409.00 Each
6 Switch of 24 Ports with 2 SFP + 2 Combo Port and Web View/CLI
on provided rack or as directed as per specification no.
WG-NWC/GBS
13899 Chapter 1-13-5 Supplying, fixing, and configuring GB Managed Ethernet Layer 2 51,504.00 Each
7 Switch of 20 Ports + 4 SFP Combo and Web View/CLI as per
specification in approved manner
13899 Chapter 1-13-6 Supplying, fixing, and configuring GB Managed Ethernet Layer 2+ 17,756.00 Each
8 Switch of 20 Ports+4 SFP Combo+10GE SFP+ and Web View/CLI
as per specification in approved manner
13899 Chapter 1-13-7 Supplying, fixing, and configuring 10G Base -SR SFP Plus MM 39,496.00 Each
9 Transceiver as per specification in approved manner
13900 Chapter 1-13-8 Supplying, fixing, and configuring Layer 3/ 20 10/100/1000 Base-T 2,27,461.00 Each
0 ports + 4 Combo 10/100/1000Base-T/SFP ports + 4 10GE SFP+
ports - SI Image as per specification in approved manner
13900 Chapter 1-13-9 Supplying, fixing, and configuring 10G Base -SR SFP Plus MM 44,970.00 Each
1 Transceiver as per specification in approved manner
13900 Chapter Supplying, fixing, and configuring 1-port mini-GBIC SX Mutli-mode 10,197.00 Each
2 1-13-10 Fibre Transceiver (up to 550m, support 3.3V power) as per
specification in approved manner
13900 Chapter Supplying, fixing, and configuring Broadband ADSL Router with all 3,976.00 Each
3 1-13-11 accessories, on provided rack or as directed as per specification
No. WG-NWC/ADSL
13900 Chapter Supplying, fixing, and configuring Modularised Multi-service 1,43,646.00 Each
4 1-13-12 Router as per specification in approved manner
13900 Chapter Supplying, fixing, and configuring Dual-path serial card as per 32,848.00 Each
5 1-13-13 specification in approved manner
13900 Chapter Supplying, fixing, and configuring DB-60 (male) to 2 x DB-34 2,915.00 Each
6 1-13-14 (male) for V.35 DTE as per specification in approved manner
Chapter 1-14 Networking Accessories (WG-NAS)
13900 Chapter 1-14 Supplying, installing & testing UTP Connector (RJ-45) as per 79.00 Each
7 -1 specification No. WG-NAS/UTPC.
13900 Chapter 1-14 Supplying and fixing Tool-less Information Outlet (Ethernet) 401.00 Each
8 -2 flush/surface type in position as per specification no. WG-NAS/IO
Rate In (Rs)
Item Description Rate Unit
13900 Chapter 1-14 Supplying and fixing Tool-less shutter Keystone Jack (RJ-45) in 92.00 Each
9 -3 provided Patch Panel complete as per specification no. WG-NAS/KJ
13901 Chapter 1-14 Supplying and fixing 24 port Patch Panel with tool-less keystone 9,516.00 Each
0 -4 jacks in provided U Rack complete as per specification no.
WG-NAS/PP
13901 Chapter 1-14 Supplying and fixing Rack mounted type 12 Ports, Light guide 3,702.00 Each
1 -5 unloaded Interconnect Unit with adapter Panel for termination of
Optical fibre cables on wall/ provided U Rack complete as per
specification no. WG-NAS/ LIU
13901 Chapter 1-14 Supplying and fixing Wall Mount 12 Ports, Light guide unloaded 3,823.00 Each
2 -6 Interconnect Unit with adapter Panel as per specification in
approved manner
13901 Chapter 1-14 Supplying and fixing 1 X 6 Duplex Adapter Panel - SC as per 259.00 Each
3 -7 specification in approved manner
13901 Chapter 1-14 Supplying and fixing Rack type 24 Ports, Light guide Interconnect 3,942.00 Each
4 -8 Unit with adapter panel for termination of Optical fibre cables on
wall/ provided U Rack complete as per specification no. WG-NAS/
LIU
13901 Chapter 1-14 Supplying and fixing Wall Mount 24 Ports, Light guide Interconnect 4,310.00 Each
5 -9 Unit with adapter panel as per specification in approved manner
13901 Chapter 1-14 Supplying and fixing 1 X 12 Duplex Adapter Panel - SC as per 284.00 Each
6 -10 specification in approved manner
13901 Chapter 1-14 Supplying and fixing SC/LC type Multimode Duplex Adaptor to 471.00 Each
7 -11 couple two connectors between OFC & Fibre switch/Fibre module
as per specification no. WG-NAS/MMA
13901 Chapter 1-14 Supplying and fixing SC/LC type Multimode Duplex Adaptor as per 478.00 Each
8 -12 specification in approved manner
13901 Chapter 1-14 Supplying and fixing SC/LC type Multimode Pigtails (OM3) for LIU 589.00 Each
9 -13 to terminate OFC in LIU as per specification No. WG-NAS/LIU2
13902 Chapter 1-14 Supplying and fixing SC/LC type Multimode Pigtails (OM3) as per 672.00 Each
0 -14 specification in approved manner
13902 Chapter 1-14 Supplying and fixing SC/LC type Multimode Pigtails (OM4) as per 1,060.00 Each
1 -15 specification in approved manner
13902 Chapter 1-14 Supplying and fixing Power over Ethernet Adaptor to provide DC 3,590.00 Each
2 -17 supply to Ethernet devices as per specification No. WG-NAS/PEA
13902 Chapter 1-14 Supplying and fixing 36 U Rack for Networking with necessary 5,066.00 Each
3 -18 arrangement for fixing required 16A/6A Switches & Plugs for LAN
network as per specification No. WG-NAS/RAK
Electrical - 2018-2019 - 01/04/2018 - Page 28 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13903 Chapter 1-14 Supplying, fixing, and configuring 8-ports Managed Gigabit 21,002.00 Each
9 -34 Switches Layer-2, 10/100/1000 Base-T PoE Smart Switch plus 2
SFP only( New)
13904 Chapter 1-14 Supplying, fixing, and configuring 20 SFP ports + 4 Combo 1,74,157.00 Each
0 -35 SFP/10/100/1000Base-T( New)
13904 Chapter 1-14 Supplying, fixing, and configuring 48 Ports Managed Gigabit 1,63,599.00 Each
1 -36 Switches Layer-2 48 10/100/1000Base-T ports L2+ Management
Switch with 4 10GE SFP+ ports ( New)
13904 Chapter 1-14 Supplying, fixing, and configuring Managed Gigabit Switches 48 55,659.00 Each
2 -37 Ports 10/100/1000Mbps + 4 SFP Ports ( New)
13904 Chapter 1-14 Supplying, fixing, and configuring Media Convertor 1000Base-T to 11,595.00 Each
3 -38 1000Base-SX SC Multi-mode Media Converter (550m) ( New)
13904 Chapter 1-14 Supplying & installing UTP networking CAT 7 Cable , 4 pair 23 AWG 121.00 Each
4 -39 CAT6A LSZH LAN Cable, standards like ANSI/TIA 568 C.2,
EN50173, IEC 11801 2nd ED, 600Mhz Speed.frequency tested
upto 700Mhz with Third Party Certificate etc.
13904 Chapter 1-14 Supplying & installing Single Mode OS1/OS2 - Armoured - 6 Core 87.00 Each
5 -40 OS1/OS2 Armoured Single mode Optical Fiber of size 50/125µm.
10/40 Gbps Speed.In Provided Underground HDPE Pipe
13904 Chapter 1-14 Supplying & installing Single Mode OS1/OS2 - Armoured - 12 Core 99.00 Each
6 -41 OS1/OS2 Armoured Single mode Optical Fiber of size 50/125µm.
10/40 Gbps Speed. In Provided Underground HDPE Pipe
13904 Chapter 1-14 Supplying & installing Single Mode OS1/OS2 - Armoured - 12 Core 99.00 Each
7 -42 OS1/OS2 Armoured Single mode Optical Fiber of size 50/125µm.
10/40 Gbps Speed. In Provided Underground HDPE Pipe
13904 Chapter 1-14 Supplying & installing Single Mode Fibre Patch Cord Patch Cords - 2,009.00 Each
8 -43 3 m – Duplex
13904 Chapter 1-14 Supplying & installing Single Mode Fibre Adaptor with Plate - 6 Port 3,647.00 Each
9 -44
13905 Chapter 1-14 Supplying & installing Single Mode PIGTAIL SIMPLEX 603.00 Each
0 -45
Chapter 1-15 Dismantling (WG-DM)
13905 Chapter 1-15-1 Dismantling the existing light, fan, bell, clock, independent 7.00 point
1 plug point, wiring including circuit mains of all types along with
accessories etc.complete as per specification No: WG-DM/PW
13905 Chapter 1-15-2 Dismantling the existing Telephone / Lan / Wan / TV cables and 4.00 Meter
2 wires of all sizes along with casing-capping / conduit complete as
per specification No: WG-DM/PW
Electrical - 2018-2019 - 01/04/2018 - Page 30 of 259 05/06/18 12:15
Chapter 1
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13907 Chapter 2 Supplying and erecting HPSV lamp 3 pin BC/Screwed cap 515.00 Each
0 -1-17 head /pin type 230V, 150 W SON-T-type.
13907 Chapter 2 Supplying and erecting HPSV lamp 3 pin BC/Screwed cap 597.00 Each
1 -1-18 head /pin type 230V, 250 W SON-T-type.
13907 Chapter 2 Supplying and erecting HPSV lamp 3 pin BC/Screwed cap 651.00 Each
2 -1-19 head /pin type 230V, 400 W SON-T-type.
13907 Chapter 2 Supplying and erecting Metal Halide lamp double ended 230V, 70 366.00 Each
3 -1-20 W.
13907 Chapter 2 Supplying and erecting Metal Halide lamp double ended 230V,150 383.00 Each
4 -1-21 W.
13907 Chapter 2 Supplying and erecting Metal Halide lamp double ended 230V, 250 646.00 Each
5 -1-22 W.
13907 Chapter 2 Supplying and erecting Metal Halide lamp double ended 230V, 400 679.00 Each
6 -1-23 W.
13907 Chapter 2 Erection of Deptt. supplied HPSV/MH/SON/SON-T/LED Type bulb. 20.00 Each
7 -1-24
13907 Chapter 2 Supplying & erecting 10-12W, 230V integral type LED Lamp 280.00 Each
8 -1-25 suitable for B-22/E-27 base.
13907 Chapter 2 Supplying & erecting 14W, 230V integral type LED Lamp suitable 318.00 Each
9 -1-26 for B-22/E-27 base.
13908 Chapter 2 Supplying & erecting 18W, 230V integral type LED Lamp suitable 617.00 Each
0 -1-27 for B-22/E-27 base.
13908 Chapter 2 Erection of Deptt.supplied retrofit T8 LED 18 / 20 tube light 5.00 Each
1 -1-28 fitting.
Chapter 2 -2 Accessories for Indoor Fittings (FG-AS)
13908 Chapter 2 -2-1 Supplying and erecting low watt loss Vaccum impregnated copper 203.00 Each
2 choke (VPIT) suitable for CFL/FTL upto 20 W as per specification
No FG/AS1
13908 Chapter 2 -2-2 Supplying and erecting low watt loss Vaccum impregnated copper 229.00 Each
3 choke (VPIT) suitable for CFL/FTL from 24 to 40 W as per
specification No. FG/AS1
13908 Chapter 2 -2-3 Supplying and erecting electronic ballast, pf > 0.9 or 223.00 Each
4 Transformer suitable for T5 lamp upto 28 W as per specification
No. FG-FG/AS1
13908 Chapter 2 -2-4 Supplying and erecting electronic ballast, pf > 0.9 or Transformer 268.00 Each
5 suitable for CFL/FTL upto 40 W as per specification No. FG-FG/AS1
Electrical - 2018-2019 - 01/04/2018 - Page 33 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13908 Chapter 2 -2-5 Supplying 18 / 20 /36 / 40 W tube starter 230 V as per 15.00 Each
6 specification No. FG-FG/AS11
13908 Chapter 2 -2-6 Supplying and erecting double suspension heavy duty lacquered 33.00 Meter
7 iron chain with hooks for erecting fluo.tube light fitting with
necessary shielded copper flexible wire three core of 1 sq mm
for connecting leads. (for measurements half of the actual length
used)
13908 Chapter 2 -2-7 Supplying and erecting double suspension pipe rod of 16 168.00 Meter
8 gauge 20mm.dia H.G.conduit duly threaded and painted with two
coats of enamel paint for erection of fluo tube light fitting with
necessary check nuts and shielded copper flexible wire three
core of 1 sq mm for connecting leads (for measurements half
of the actual length both pipes used)
13908 Chapter 2 -2-8 Supplying and erecting ball suspension plate cast aluminium 32.00 Each
9 erected with spring on wooden block in position.
13909 Chapter 2 -2-9 Providing and erecting clamps for box type / industrial type fittings 70.00 Each
0 with provided suspension down rod of 20 mm dia.
H.G.conduit,the clamp shall be made of 25 x 3 mm MS flat with
Cutting,bending,drilling erected properly with necessary nut bolt as
per direction.
13909 Chapter 2 Supplying and fixing wiremesh (Jali) cover suitable for fitting / fan 416.00 Each
1 -2-10 or for any purpose, complete with necessary materials. The Jali
cover shall be made from good quality G.I. wire mesh size 25
mm x 25 mm and made up of 14 SWG G.I. wire with side /
supporting MS strips of suitable size.
13909 Chapter 2 Supplying and erecting Bakelite call bell with 6 cm / buzzer 63.00 Each
2 -2-11 with double coil suitable for 230V complete erected on PVC
block.
13909 Chapter 2 Supplying and erecting gong with double coil suitable for 73.00 Each
3 -2-12 230V. complete erected on polished wooden block.
13909 Chapter 2 Supplying and erecting Ding Dong / electronic musical type call 108.00 Each
4 -2-13 bell with heavy duty coil suitable to operate on 230V A.C. supply
erected on polished double wooden block/sunmica block of suitable
size
13909 Chapter 2 Supplying and erecting luminous / modular type call bell 215.00 Each
5 -2-14 indicator with plastic body, heavy duty coil and indicator lamp
working on 230V A.C. supply with resetting arrangement complete
erected on double wooden/ sunmica board
Rate In (Rs)
Item Description Rate Unit
13909 Chapter 2 Supplying and erecting Electronic Type cordless call bell erected 420.00 Each
6 -2-15 on T.W. board having portable bell push working on 9V.
D.C.battery and (Effective range upto 45 meter) bell on 250 V
A.C. supply.
13909 Chapter 2 Supplying and erecting condenser 4 microfarad for fluo. Fitting, as 86.00 Each
7 -2-17 per specification No FG-FG/AS7
13909 Chapter 2 Supplying and erecting electronic type 600 W dimmer complete 142.00 Each
8 -2-18 erected on provided switch board.
13909 Chapter 2 Supplying and erecting electronic type 300/450 W dimmer 148.00 Each
9 -2-19 complete erected on provided switch board.
Chapter 2 -3 Decorative Indoor Fittings (FG-IDF)
13910 Chapter 2 -3-1 Supplying table lamp with M.S. tube with flexible joints 1,052.00 Each
0 complete suitable for lamp 1 x upto 13 W complete with lamp and
3 core round PVC flexible cord with 6A 3 pin hand shield type plug
top.
13910 Chapter 2 -3-2 Supplying shock proof type hand lamp with lamp holder, guarded 143.00 Each
1 glass and 10 m of 3 core PVC flexible cord with hand shield type 3
pin 6 Amp plug top.
13910 Chapter 2 -3-3 Supplying and erecting plain pendent type bakelite lamp 33.00 Each
2 holder complete erected at position with necessary length of twin
flexible wire.(upto 1m)
13910 Chapter 2 -3-4 Supplying and erecting plain pendent type brass lamp holder 85.00 Each
3 complete erected at position with 20 cms glass opal shade
with necessary length of twin twisted flexible wire 24 / 0.20 mm.
(upto 1m)
13910 Chapter 2 -3-5 Supplying and erecting Rod Pendent light with 20 mm dia. 159.00 Each
4 H.G. screwed conduit of 16 SWG duly painted with ball
suspension plate, with glass opal shade complete erected on
polished double wooden block with necessary PVC wire leads.
13910 Chapter 2 -3-6 Supplying and erecting one light Wall bracket fitting with 131.00 Each
5 dome complete fixed on the wall.
13910 Chapter 2 -3-7 Supplying and erecting one light wall bracket MS body & 232.00 Each
6 arm Chromium plated/ powder coated complete fixed on wall.
13910 Chapter 2 -3-8 Supplying and erecting glass shade of suitable size and 87.00 Each
7 shape of approved colour and quality on existing decorative fitting
13910 Chapter 2 -3-9 Supplying and erecting bulkhead fitting suitable for upto LED 200.00 Each
8 upto 12W fixed on wall. As per specification no.FG-IDF/BHF
Rate In (Rs)
Item Description Rate Unit
13910 Chapter 2 Supplying and erecting 1 light wall bracket Aluminium body & arm 241.00 Each
9 -3-10 anodised / powder coated with decorative glass shade fixed on
wall.
13911 Chapter 2 Supplying and erecting 2 light wall bracket Aluminium body & arm 339.00 Each
0 -3-11 anodised / powder coated complete with lamp holder and
decorative glass shade suitably erected on polished wooden
board / plywood pasted with laminate.
13911 Chapter 2 Supplying and erecting 1 light fancy wall bracket with arm 413.00 Each
1 -3-12 fabricated from brass duly lacquered with suitable holder and
fancy glass shade duly wired erected on wall with suitable size of
polished wooden / laminated board.
13911 Chapter 2 Supplying and erecting 2 light fancy wall bracket with arm 658.00 Each
2 -3-13 fabricated from brass duly lacquered with suitable holder and
fancy glass shade duly wired erected on wall with suitable size of
polished wooden / laminated board.
13911 Chapter 2 Supplying & erecting approved type suspension type 392.00 Each
3 -3-14 decorative pendent fitting single light with anodized aluminium /
powder coated MS rod up to 1 m length and canopy on top
provided with decorative glass shed duly wired with two core
flat wire suitable lamp holder complete.
13911 Chapter 2 Supplying & erecting approved type suspension type decorative 1,352.00 Each
4 -3-15 fitting with rise /fall arrangement, 1 light inside semi circular
metallic reflector with counterweight with guide pulley / spring
buffer with work shop type copper flexible wire complete with
necessary hook, if required
13911 Chapter 2 Erection of Departmentally supplied fitting on PVC block 49.00 Each
5 -3-16 connected with necessary leads for 4’40 Watts. fitting and 2’20 W.
fitting and with marking the sr. no. & date of erection.
13911 Chapter 2 Erection of Departmentally supplied surface/recess type decorative 49.00 Each
6 -3-17 fitting with LED on PVC block connected with necessary leads.
13911 Chapter 2 Erection of Departmentally supplied mirror optic type fitting on 54.00 Each
7 -3-18 PVC block connected with necessary leads and with marking the
Sr. No. & date of erection.
Chapter 2 -4 General Indoor Fittings (FG-IDF)
13911 Chapter 2 -4-1 Supplying and erecting 2 x 36 / 40W FTL corrosion proof Capsule 3,331.00 Each
8 type in non corrosive polycarbonate housing and prismatic
polycarbonate cover with individual high power electronic ballast
saving Power factor >0.9 and working voltage range of 170 - 270V
ACIP 65 protection suitable for cold storage areas to be fixed in
false ceiling or at ceiling or on wall complete.
Electrical - 2018-2019 - 01/04/2018 - Page 36 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13914 Chapter 2 Supplying & erecting T8 LED 20W tube light fitting (4 feet) with 877.00 Each
0 -5-22 aluminium housing, heat sink, integrated HF electronic driver
complete( including lamp).
13914 Chapter 2 Supplying and erecting LED flexible strip light 5m length upto 75W 4,377.00 Each
1 -5-23 conforming IP 65 of any colour with driver complete.
Chapter 2 -6 Accessories for Outdoor Fittings (FG-AS)
13914 Chapter 2 -6-1 Supplying and erecting Street light bracket made from 25 mm. dia 483.00 Each
2 ‘B’class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm
length and 80 mm dia duly welded with provided leads as per
specification no.FG-BKT/BPC
13914 Chapter 2 -6-2 Supplying and erecting Street light bracket made from 40 mm. dia 548.00 Each
3 ‘B’class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm
length and 80 mm dia duly welded with provided leads as per
specification no.FG-BKT/BPC
13914 Chapter 2 -6-3 Supplying and erecting street light Wall bracket made from 25 501.00 Each
4 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per
specification no. FG-BKT/WB
13914 Chapter 2 -6-4 Supplying and erecting street light Wall bracket made from 40 631.00 Each
5 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per
specification no. FG-BKT/WB
13914 Chapter 2 -6-5 Supplying and erecting Street light bracket for erection of Single 769.00 Each
6 fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length
along with pole cap of 300 mm length 100 mm dia duly welded as
per specification no. FG-BKT/BPC
13914 Chapter 2 -6-6 Supplying and erecting Street light bracket for erection of Double 1,067.00 Each
7 fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length
along with pole cap of 300 mm length 100 mm dia duly welded as
per specification no. FG-BKT/BPC
13914 Chapter 2 -6-7 Supplying and erecting Street light bracket for erection of Single 1,268.00 Each
8 fitting on tubular welded pole with 40 mm.dia 1.0 m long “B”
grade G.I.pipe along with pole cap of 125mm dia 600 mm long
duly welded as per specification no. FG-BKT/BPC
13914 Chapter 2 -6-8 Supplying and erecting Street light bracket for erection of Double 1,566.00 Each
9 fitting on tubular welded pole with 40 mm.dia 1.0 m long “B”
grade G.I.pipe along with pole cap of 125mm dia 600 mm long
duly welded as per specification no. FG-BKT/BPC
13915 Chapter 2 -6-9 Supplying and erecting Street light bracket for erection of side 420.00 Meter
0 entry fitting on pole with 40 mm. dia. ‘B’ grade G.I. pipe of
required length complete as per specification no. FG-BKT/SLB
Electrical - 2018-2019 - 01/04/2018 - Page 39 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13915 Chapter 2 Supplying and erecting Street light bracket for erection of side 331.00 Meter
1 -6-10 entry fitting on pole with 25 mm. dia. ‘B’ grade G.I. pipe of
required length complete as per specification no. FG-BKT/SLB
13915 Chapter 2 Supplying and erecting Control gear1x250W for HPSV/MH lamp 3,190.00 Each
2 -6-11 with all accessories for NON Integral Flood light fittings suitable for
complete
13915 Chapter 2 Supplying and erecting Control gear for NON Integral Flood light 4,189.00 Each
3 -6-12 fittings suitable for1x400W HPSV/MH lamp with all accessories
complete.
13915 Chapter 2 Supplying and erecting Control gear for NON Integral Flood light 7,375.00 Each
4 -6-13 fittings suitable for2x250W HPSV/MH lamp with all accessories
complete.
13915 Chapter 2 Supplying and erecting Control gear for NON Integral Flood light 10,002.00 Each
5 -6-14 fittings suitable for2x400W HPSV/MH lamp with all accessories
complete.
13915 Chapter 2 Supplying and erecting condesor for MV/SV/MH lamp 150W,230V 190.00 Each
6 -6-15 as per specification no. FG-FG/AS7
13915 Chapter 2 Supplying and erecting condesor for MV/SV/MH lamp 250W,230V 208.00 Each
7 -6-16 as specification no. FG-FG/AS7
13915 Chapter 2 Supplying and erecting condesor for MV/SV/MH lamp 400W,230V 270.00 Each
8 -6-17 as specification no. FG-FG/AS7
13915 Chapter 2 Supplying and erecting ignitor suitable for 230V HPSV 191.00 Each
9 -6-18 lamp70/150/250/400W as specification no. FG-FG/AS6
13916 Chapter 2 Supplying and erecting electronic ignitor suitable for 230V metal 298.00 Each
0 -6-19 halide lamp 70/150/250/400W (integral or non integral type
luminaries as specification no. FG-FG/AS6
13916 Chapter 2 Supplying and erecting VPIT heavy duty copper wound ballast 995.00 Each
1 -6-20 230Vfor 80-150W HPSV/MV/MH as per specification no.
FG-FG/AS5.
13916 Chapter 2 Supplying and erecting VPIT compound heavy duty copper wound 1,958.00 Each
2 -6-21 ballast for 230V for 250W HPSV/MV/MH as per specification no.
FG-FG/AS5.
13916 Chapter 2 Supplying and erecting VPIT heavy duty copper wound ballast 2,577.00 Each
3 -6-22 for230V for 400W HPSV/MV/MH as per specification no.
FG-FG/AS4.2.7 Decorative Outdoor Fitting ( FG-ODF)
Chapter 2 -7 Decorative Outdoor Fittings (FG-ODF)
Rate In (Rs)
Item Description Rate Unit
13916 Chapter 2 -7-1 Supplying and erecting gate/garden light fitting with 200mm 400.00 Each
4 dia.glass bowl suitable for upto 12W LED Lamp on provided pipe
as per specification No. FG-ODF/GLT
13916 Chapter 2 -7-2 Supplying and erecting gate/garden light fitting with 300mm 917.00 Each
5 dia.glass bowl suitable for upto 12W LED Lamp on provided pipe as
per specification No. FG-ODF/GLT
13916 Chapter 2 -7-3 Supplying & erecting integral post top lantern fixtures(mushroom 1,784.00 Each
6 type) suitable for LED lamp upto 12 W consisting of clear acrylic
top cover,cast aluminium pole cap complete with accessories on
provided pole /bracket as per specification no. FG-ODF/PTL
13916 Chapter 2 -7-4 Supplying & erecting integral post top lantern fixtures (globe type) 1,814.00 Each
7 suitable for LED lamp upto 12 W consisting of aesthetic round clear
acrylic top cover, cast aluminium pole cap on provided
pole /bracket as per specification no. FG-ODF/PTL (NEW)
13916 Chapter 2 -7-5 Supplying & erecting integral post top lantern fixtures (light house 2,116.00 Each
8 type) suitable upto LED 18 W Lamp consisting of combination of
spun aluminium canopy & clear acrylic top cover, cast aluminium
pole cap on provided pole/ bracket as per specification no.
FG-ODF/PTL (NEW)
Chapter 2 -8 Street/Flood Light Fittings (FG-ODF)
13916 Chapter 2 -8-1 Supplying and erecting street light fitting suitable for 70W 1,821.00 Each
9 H.P.S.V.lamp with accessories complete on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-2 Supplying and erecting street light fitting suitable for 150W 2,116.00 Each
0 H.P.S.V.lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-3 Supplying and erecting street light fitting suitable for 250W 2,803.00 Each
1 H.P.S.V.lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-4 Supplying and erecting street light fitting suitable for 400W 4,138.00 Each
2 H.P.S.V.lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-5 Supplying and erecting street light fitting suitable for 70W metal 2,302.00 Each
3 halide lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-6 Supplying and erecting street light fitting suitable for 150W metal 2,980.00 Each
4 halide lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
Rate In (Rs)
Item Description Rate Unit
13917 Chapter 2 -8-7 Supplying and erecting street light fitting suitable for 250W metal 3,715.00 Each
5 halide lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-8 Supplying and erecting street light fitting suitable for 400W metal 6,596.00 Each
6 halide lamp complete with accessories on provided bracket as per
specification no. FG-ODF/GSL
13917 Chapter 2 -8-9 Supplying and erecting flood light luminaries suitable for 2,784.00 Each
7 70WH.P.S.V. lamp complete with accessories on provided bracket
as per specification no. FG-ODF/GSL
13917 Chapter 2 Supplying and erecting flood light luminaries suitable for 150W 4,453.00 Each
8 -8-10 H.P.S.V. lamp complete with accessories on provided bracket as
per specification no. FG-ODF/GFL
13917 Chapter 2 Supplying and erecting flood light luminaries suitable for 250W 4,692.00 Each
9 -8-11 H.P.S.V. lamp complete with accessories on provided bracket as
per specification no. FG-ODF/GFL
13918 Chapter 2 Supplying and erecting flood light luminaries suitable for 400W 4,749.00 Each
0 -8-12 H.P.S.V. lamp complete with accessories on provided bracket as
per specification no. FG-ODF/GFL
13918 Chapter 2 Supplying and erecting asymmetrical beam integral flood light 2,554.00 Each
1 -8-13 luminaries suitable for 70W metal halide lamp complete with
accessories on provided bracket as per specification no.
FG-ODF/GFL
13918 Chapter 2 Supplying and erecting asymmetrical beam integral flood light 2,903.00 Each
2 -8-14 luminaries suitable for 150W metal halide lamp complete with
accessories on provided bracket as per specification no.
FG-ODF/GFL
13918 Chapter 2 Supplying and erecting asymmetrical beam integral flood light 4,721.00 Each
3 -8-15 accessories luminaries suitable for 250W metal halide lamp
complete with accessories on provided bracket as per specification
no. FG-ODF/GFL
13918 Chapter 2 Supplying and erecting asymmetrical beam integral flood light 4,766.00 Each
4 -8-16 luminaries suitable for 400W metal halide lamp complete with
accessories on provided bracket as per specification no.
FG-ODF/GFL
13918 Chapter 2 Supplying & erecting non integral symmetrical flood light with wide 2,573.00 Each
5 -8-17 beam reflector luminaries suitable for 1x250W HPSV/MH lamp on
provided bracket as per specification no. FG-ODF/HML
Rate In (Rs)
Item Description Rate Unit
13918 Chapter 2 Supplying & erecting non integral symmetrical flood light with wide 2,573.00 Each
6 -8-18 beam reflector luminaries suitable for 1x400W HPSV/MH lamp on
provided bracket as per specification no. FG-ODF/HML
13918 Chapter 2 Supplying & erecting non integral heavy duty flood light with 3,488.00 Each
7 -8-19 symmetric circular narrow beam reflector luminaries suitable
for1x250W HPSV/MH lamp on provided bracket as per specification
no.FG-ODF/HML
13918 Chapter 2 Supplying & erecting non integral heavy duty flood light with 3,488.00 Each
8 -8-20 symmetric circular narrow beam reflector luminaries suitable
for1x400W HPSV/MH lamp on provided bracket as per specification
no.FG-ODF/HML
13918 Chapter 2 Supplying & erecting non integral symmetric wide beam flood light 4,224.00 Each
9 -8-21 luminaries suitable for 2x250W HPSV/MH lamp on provided
brackets per specification no. FG-ODF/HML
13919 Chapter 2 Supplying & erecting non integral symmetric wide beam flood light 4,224.00 Each
0 -8-22 luminaries suitable for 2x400W HPSV/MH lamp on provided
brackets per specification no. FG-ODF/HML
13919 Chapter 2 Erecting the departmentally supplied W.P. /LED/T-5/T-8/LED street 75.00 Each
1 -8-23 light fitting and marking / painting the Sr. No. and date of erection
by best quality enamel paint.
13919 Chapter 2 Erecting Deptt. supplied H.P.S.V/ M.H./ LED street light/ LED Flood 110.00 Each
2 -8-24 light Fitting upto 150W & marking / painting Sr. No. & date of
erection by best quality enamel paint.
13919 Chapter 2 Erecting Deptt. supplied H.P.S.V/ M.H./LED street light/Flood light 134.00 Each
3 -8-25 Fitting of 250 to 400W & marking/ painting Sr. No. & date of
erection by best quality enamel paint
Chapter 2 -9 LED Outdoor Fittings (FG-ODF/LED)
13919 Chapter 2 -9-1 Supplying and erecting LED street light fitting 12 to 18 W, with PF 1,765.00 Each
4 > 0.95 class IP 65 and above Housing of pressure die cast
alluminium alloy and heat sink extruded alluminium complete as
per specification No FG-ODF/FLS-2
13919 Chapter 2 -9-2 Supplying and erecting LED Street light fitting suitable for 20 to 2,182.00 Each
5 25W, with PF > 0.95 class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete as per specification No FG-ODF/FLS-2.
13919 Chapter 2 -9-3 Supplying and erecting LED street light fitting suitable above 26W 2,600.00 Each
6 to 36W lamp, including lamp, with PF > 0.95 class IP 65 and
above Housing of pressure die cast alluminium alloy and heat sink
extruded alluminium complete as per specification No
Electrical - 2018-2019 FG-ODF/FLS2
- 01/04/2018 - Page 43 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
FG-ODF/FLS2
13919 Chapter 2 -9-4 Supplying and erecting LED Street light fitting suitable for above 3,955.00 Each
7 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65
and above Housing of pressure die cast alluminium alloy and heat
sink extruded alluminium complete per specification No .
FG-ODF/FLS2
13919 Chapter 2 -9-5 Supplying and erecting LED street light fitting suitable for 60W 5,273.00 Each
8 lamp, including lamp, with PF > 0.95 class IP 65 and above
Housing of pressure die cast alluminium alloy and heat sink
extruded alluminium complete as per specification No
FG-ODF/FLS-2.
13919 Chapter 2 -9-6 Supplying and erecting LED street light fitting suitable for above 5,841.00 Each
9 70W- 75 lamp, including lamp, with PF > 0.95 class IP 65 and
above Housing of pressure die cast alluminium alloy and heat sink
extruded alluminium complete per specification No FG-ODF/FLS2
13920 Chapter 2 -9-7 Supplying and erecting LED street light fitting suitable for 7,711.00 Each
0 above75 - 90W lamp, including lamp, with PF > 0.95 class IP 65
and above Housing of pressure die cast alluminium alloy and heat
sink extruded alluminium complete per specification No.
FG-ODF/FLS2
13920 Chapter 2 -9-8 Supplying and erecting LED street light fitting 100W, including 8,260.00 Each
1 lamp, with PF > 0.95 class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2
13920 Chapter 2 -9-9 Supplying and erecting LED street light fitting 120 W, including 10,065.00 Each
2 lamp, with PF > 0.95 class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2.
13920 Chapter 2 Supplying and erecting LED street light fitting 150 W, including 17,029.00 Each
3 -9-10 lamp, with PF > 0.95 class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2.
13920 Chapter 2 Supplying and erecting LED street light fitting suitable for 160 17,661.00 Each
4 -9-11 -170 W, including lamp, with PF > 0.95 class IP 65 and above
Housing of pressure die cast alluminium alloy and heat sink
extruded alluminium complete per specification No FG-ODF/FLS-2
13920 Chapter 2 Supplying and erecting LED Flood light fitting of 30-40W, 2,648.00 Each
5 -9-12 including lamp, with PF > 0.95,class IP 65 and above class IP 65
and above Housing of pressure die cast alluminium alloy and heat
sink extruded alluminium complete per specification No
FG-ODF/FLS-2
Electrical - 2018-2019 - 01/04/2018 - Page 44 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
FG-ODF/FLS-2
13920 Chapter 2 Supplying and erecting LED Flood light fitting of 50W, including 4,241.00 Each
6 -9-13 lamp, with PF > 0.95,class IP 65 and above class IP 65 and
above Housing of pressure die cast alluminium alloy and heat sink
extruded alluminium complete per specification No FG-ODF/FLS-2
13920 Chapter 2 Supplying and erecting LED Flood light fitting of 70- 80W, 7,632.00 Each
7 -9-14 including lamp, with PF > 0.95,class IP 65 and above Housing of
pressure die cast alluminium alloy and heat sink extruded
alluminium complete per specification No FG-ODF/FLS-2
13920 Chapter 2 Supplying and erecting LED Flood light fitting of 90-100W, 9,459.00 Each
8 -9-15 including lamp, with PF > 0.95, class IP 65 and above Housing of
pressure die cast alluminium alloy and heat sink extruded
alluminium complete per specification No FG-ODF/FLS-2
13920 Chapter 2 Supplying and erecting LED Flood light fitting of 120W, including 13,179.00 Each
9 -9-16 lamp, with PF > 0.95,class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2
13921 Chapter 2 Supplying and erecting LED Flood light fitting of 150W, including 15,573.00 Each
0 -9-17 lamp, with PF > 0.95,class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2
13921 Chapter 2 Supplying and erecting LED Flood light fitting of 200W, including 20,272.00 Each
1 -9-18 lamp, with PF > 0.95,class IP 65 and above Housing of pressure
die cast alluminium alloy and heat sink extruded alluminium
complete per specification No FG-ODF/FLS-2
13921 Chapter 2 Supplying and erecting Recess mounted 20W LED wall washers, 3,546.00 Each
2 -9-19 tilted 70° outwards and swivels 360° to offer best illumination on
the wall with any colour with driver complete. ( Including
Compatible Driver)
13921 Chapter 2 Supplying and erecting Recess mounted 30W LED wall washers, 4,865.00 Each
3 -9-20 tilted 70° outwards and swivels 360° to offer best illumination on
the wall with any colour with driver complete. ( Including
Compatible Driver)
13921 Chapter 2 Supplying & erecting 12W LED PAR (30 Lamp E-27 Base, SPOTO 1,651.00 Each
4 -9-21 SERIES) lights by making necessary arrangement/recess in wall to
make it flush with surface.
13921 Chapter 2 supplying & erecting 20W LED PAR (30 Lamp E-27 Base, SPOTO 5,029.00 Each
5 -9-22 series) lights by making necessary arrangement/recess in wall to
make it flush with surface.
Rate In (Rs)
Item Description Rate Unit
13921 Chapter 2 Supplying & erecting 15W LED SERIES PAR lights by making 2,490.00 Each
6 -9-23 necessary arrangement/recess in wall to make it flush with
surface.
13921 Chapter 2 Supplying and erecting Cylindrical shaped Integral decorative 3,516.00 Each
7 -9-24 with high power 9W LED bollard with opal acrylic diffuser and IP65
protection on provided foundation.(NEW) upto 1000MM
13921 Chapter 2 Supplying and erecting Mushroom shaped integral 9W LED 5,634.00 Each
8 -9-25 decorative bollard with IP65 protection on provided foundation.
(NEW) upto 680MM
13921 Chapter 2 Supplying and erecting 40W LED post top made in cast 6,190.00 Each
9 -9-26 aluminium spigot housing with decorative clear opal acrylic diffuser
and IP65 Protection on provided pole/ bracket.
Chapter 2 -10 Outdoor LED Fittings (FG-ODF/LED)
13922 Chapter 2 Supplying and erecting highbay LED fitting IP 65 with lamp 80W, 11,052.00 Each
0 -10-1 PF >0.95 of approved make and duly connecting complete as per
specification no. FG-ODF/LED
13922 Chapter 2 Supplying and erecting highbay LED fitting IP 65 with lamp 120W, 12,407.00 Each
1 -10-2 PF >0.95 of approved make and duly connecting complete as per
specification no. FG-ODF/LED
13922 Chapter 2 Supplying and erecting highbay LED fitting IP 65 with lamp 150W, 16,444.00 Each
2 -10-3 PF >0.95 of approved make and duly connecting complete as per
specification no. FG-ODF/LED
Chapter 2 -11 Aviation Light Fittings
13922 Chapter 2 Supplying & erecting aviation obstruction light consisting of yellow 4,251.00 Each
3 -11-1 painted die-cast aluminium alloy housing with Integral LED
aviation light comprising of aluminium housing with polycarbonate
enclosure complete.
Chapter 2 -12 Accessories for Fans (FG-FN)
13922 Chapter 2 Supplying and erecting condenser 2.5 micro farad for ceiling fan 56.00 Each
4 -12-1
13922 Chapter 2 Supplying & fixing Anchor type fastener Fan hook, with 2 Nos of 82.00 Each
5 -12-2 10mm dia x 75 mm long with necessary materials for Ceiling Fan.
13922 Chapter 2 Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of 154.00 Each
6 -12-3 required length and 10 mm. M.S. bolt and nuts erected with
necessary hook of 10 mm. M.S. round bar and painted.
13922 Chapter 2 Supplying and erecting Fan hook of 10 mm. M.S. round bar 94.00 Each
7 -12-4 grouted in RCC slab with making the site as original.
Rate In (Rs)
Item Description Rate Unit
13922 Chapter 2 Supplying and erecting fan hook box of 10 mm M.S. round bar 120.00 Each
8 -12-5 bounded to the R.C.C. bars upto 50 mm length each side and
pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm
dia.or equivalent square size and having depth upto 75 mm
complete erected with duly painted by one coat of red oxide paint
and two coats of paint erected in position and without any leakage
of slurry of cement concrete on either side of the box and
positioned to the bottom level of the slab.
13922 Chapter 2 Supplying and erecting ‘B’ grade G.I.pipe/M.S. pipe down rod duly 171.00 Meter
9 -12-6 painted for fan complete erected with PVC three core flexible cable
1 sq. mm copper PVC wire.
13923 Chapter 2 Erection of departmentally supplied ceiling fan with necessary 85.00 Each
0 -12-7 materials,and marking / painting the Sr. No. and date of erection
by best quality enamel paint.
13923 Chapter 2 Erection of departmentally supplied Exhaust fan with necessary 153.00 Each
1 -12-8 materials, and marking / painting the Sr. No. and date of erection
by best quality enamel paint.
13923 Chapter 2 Supplying and erecting electronic type step regulator for ceiling fan 186.00 Each
2 -12-9 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided
switch board.
13923 Chapter 2 Providing recess in brick wall suitable for erection of exhaust fan 261.00 Each
3 -12-10 up to 450mm sweep complete with grouting of nut, bolts, plaster
in hand colour washing to match the colour of the wall for the wall
thickness of 150 mm
13923 Chapter 2 Providing recess in brick wall suitable for erection of exhaust fan 309.00 Each
4 -12-11 up to 450mm. sweep complete with grouting of nut, bolts,
plastering and colour washing to match the colour of the wall for
the wall thickness of 225 mm
13923 Chapter 2 Providing recess in brick wall suitable for erection of exhaust fan 373.00 Each
5 -12-12 up to 450mm. sweep complete with grouting of nut, bolts,
plastering and colour washing to match the colour of the wall for
the wall thickness of 375 mm.
13923 Chapter 2 Providing recess in stone wall suitable for erection of exhaust fan 564.00 Each
6 -12-13 up to 450mm sweep complete with grouting of nut, bolts,
plastering and colour washing to match the colour of the wall.
13923 Chapter 2 Supplying & erecting 22 guage G.I sheet metal CAWL sector 879.00 Each
7 -12-14 shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh
to avoid birds entry with necessary material, suitable for exhaust
fan of 300 mm as per specification no FG-FAS/MSC
Rate In (Rs)
Item Description Rate Unit
13923 Chapter 2 Supplying & erecting 22 guage G.I sheet metal CAWL sector 957.00 Each
8 -12-15 shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh
to avoid birds entry with necessary material, suitable for exhaust
fan of 400 mm as per specification no FG-FAS/MSC
13923 Chapter 2 Supplying & erecting 22 guage G.I sheet metal CAWL sector 1,015.00 Each
9 -12-16 shaped with 25 mm x 25mm x 3mm angle iron frame, metal mesh
to avoid birds entry with necessary material, suitable for exhaust
fan of 450 mm as per specification no FG-FAS/MSC
13924 Chapter 2 Supplying & erecting 20 guage G.I sheet metal CAWL 905.00 Each
0 -12-17 rectangular /round shaped with 25 mm x 25mm x 3mm angle iron
frame, metal mesh to avoid birds entry with necessary material,
suitable for exhaust fan of 300 mm as per specification no
FG-FAS/MSC
13924 Chapter 2 Supplying & erecting 20 guage G.I sheet metal CAWL 1,110.00 Each
1 -12-18 rectangular /round shaped with 25 mm x 25mm x 3mm angle iron
frame, metal mesh to avoid birds entry with necessary material,
suitable for exhaust fan of 400 mm as per specification no
FG-FAS/MSC
13924 Chapter 2 Supplying & erecting 20 guage G.I sheet metal CAWL 1,157.00 Each
2 -12-19 rectangular /round shaped with 25 mm x 25mm x 3mm angle iron
frame, metal mesh to avoid birds entry with necessary material,
suitable for exhaust fan of 450 mm as per specification no
FG-FAS/MSC
Chapter 2 -13 Fans (FG-FN)
13924 Chapter 2 Supplying and erecting regular/ standard model Ceiling fan of 1,487.00 Each
3 -13-1 600mm. sweep complete erected in position as per specification
no. FG-FN/CF
13924 Chapter 2 Supplying and erecting regular/ standard model Ceiling fan of 1,476.00 Each
4 -13-2 900 /1050 mm. sweep complete erected in position as per
specification no. FG-FN/CF
13924 Chapter 2 Supplying and erecting regular/ standard model Ceiling fan of 1,498.00 Each
5 -13-3 1200mm. sweep complete erected in position as per specification
no. FG-FN/CF
13924 Chapter 2 Supplying and erecting regular/ standard model Ceiling fan of 1,604.00 Each
6 -13-4 1400mm. sweep complete erected in position as per specification
no. FG-FN/CF
13924 Chapter 2 Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 1,691.00 Each
7 -13-5 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades
chrome plated guard with regulator and moisture proof treatment
to winding and with ‘E’ class insulation and marking Sr. No. and
Electrical - 2018-2019 date
- 01/04/2018 -
of erection. Page 48 of 259 05/06/18 12:15
Chapter 2
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
to winding and with ‘E’ class insulation and marking Sr. No. and
date of erection.
13924 Chapter 2 Providing and erecting air circulator 450 mm. sweep oscillating 4,094.00 Each
8 -13-6 type,wall mounting 1440 RPM without speed regulator, overheat
protection unit, totally enclosed, flame proof motor suitable
for230/250 Volts single phase, 50 cycles A.C. supply, with one
metre of 3core lead wire and with moisture proof treatment to
winding and with ‘E’class insulation and marking Sr. No. and date
of erection.
13924 Chapter 2 Providing and erecting air circulator 600 mm. sweep oscillating 4,879.00 Each
9 -13-7 type,wall mounting 1440 RPM without speed regulator, overheat
protection unit, totally enclosed, flame proof motor suitable for
230/250 Volts single phase, 50 cycles A.C. supply, core lead wire
and with moisture proof treatment to winding and with ‘E’class
insulation and marking Sr. No. and date of erection.
13925 Chapter 2 Supplying Pedestal fan 400 mm. 230 Volts 50 cycles oscillating 1,863.00 Each
0 -13-8 type complete with guard and regulator 3 mtrs. of flexible wire and
hand shield type 3 pin plug top and marking Sr. No. and date of
erection.
13925 Chapter 2 Supplying pedestal type air circulator 450 mm. sweep oscillating 4,105.00 Each
1 -13-9 type suitable to work on 230 Volts 50 cycles 1440 RPM with speed
regulator, overhead protection unit, totally enclosed, flame proof
motor with additional 3 core wire, 5 metre length and Hand Shield
type 3 pin5A. plug top complete with moisture proof treatment and
‘E’ class insulation and marking Sr. No. and date of erection.
13925 Chapter 2 Supplying pedestal type air circulator 600 mm. sweep oscillating 6,634.00 Each
2 -13-10 type suitable to work on 230 Volts 50 cycles 1440 RPM with speed
regulator, overhead protection unit, totally enclosed, flame proof
motor with additional 3 core wire, 5 metre length and Hand Shield
type 3 pin6A. plug top complete with moisture proof treatment and
‘E’ class insulation and marking Sr. No. and date of erection.
13925 Chapter 2 Supplying Table fan of A.C. 230 V. 50 cycles 400 mm. oscillating 1,478.00 Each
3 -13-11 type complete with 2 mtrs. of 3 core flexible wire and Hand shield
type 3 pin plug top and marking Sr. No. and date of erection
13925 Chapter 2 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 1,340.00 Each
4 -13-12 mm. /300 mm. sweep complete with necessary brackets for fixing
cabin fans,wire etc and marking Sr. No. and date of erection.
13925 Chapter 2 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 400 mm. 1,497.00 Each
5 -13-13 sweep complete with necessary brackets for fixing cabin fans, wire
etc and marking Sr. No. and date of erection.
Rate In (Rs)
Item Description Rate Unit
13925 Chapter 2 Supplying and erecting fresh air cum Exhaust fan of light duty 250 1,264.00 Each
6 -13-14 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades,
wiremesh, duly erected in an approved manner and marking Sr.
No. And date of erection.
13925 Chapter 2 Supplying and erecting fresh air cum Exhaust fan of light duty250 1,126.00 Each
7 -13-15 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades,
wiremesh, duly erected in an approved manner and marking Sr.
No. And date of erection.
13925 Chapter 2 Supplying and erecting Exhaust fan medium duty 230 V A.C. 1,494.00 Each
8 -13-16 50cycles 225 mm. 1400RPM with condensor complete erected in
position with necessary materials. Fan motor with moisture proof
treatment and‘E’ class insulation and marking Sr. No. & date of
erction.
13925 Chapter 2 Supplying and erecting Exhaust fan heavy duty 230 V, A.C. 50 2,882.00 Each
9 -13-17 cycles 375/380 mm. 900 RPM complete erected in position as per
specifcation no. FG-FN/EXF
13926 Chapter 2 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 2,921.00 Each
0 -13-18 cycles 375/380 mm. 1400 RPM complete erected in position as
perspecifcation no. FG-FN/EXF
13926 Chapter 2 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 4,001.00 Each
1 -13-19 cycles 450 mm. 1400 RPM complete erected in position as per
specifcation no. FG-FN/EXF
13926 Chapter 2 Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 3,659.00 Each
2 -13-20 cycles 450 mm. 900 RPM complete erected in position as per
specification no.FG-FN/EXF
13926 Chapter 2 Supplying and erecting Exhaust fan heavy duty 440 V A.C. 50 3,058.00 Each
3 -13-21 cycles 900 RPM 375/380 mm complete erected in position as per
specification no. FG-FN/EXF
13926 Chapter 2 Supplying and erecting Five Star Rated Energy Saving Ceiling Fan 1,563.00 Each
4 -13-22 230 V A.C. 50 cycles 1200 mm complete erected in position as per
specifcation no. FG-FN/CF
13926 Chapter 2 Supplying and erecting Modern finished blades with unique double 2,590.00 Each
5 -13-23 bend angle, double ball bearings with energy efficient Decorative
Ceiling Fan 1200/1400 mm sweep complete erected in position as
per specifcation no. FG-FN/CF (Decorative)
Chapter 2 -14 Dismantling
13926 Chapter 2 Dismantling of existing fluorescent fittings of any type & size. 13.00 Each
6 -14-1
Rate In (Rs)
Item Description Rate Unit
13926 Chapter 2 Dismantling the existing W.T.fluoroscent fitting / S.V./ M.V. / M.H. 38.00 Each
7 -14-2 lamp /LED fitting from wall with brackets and making the site as
original complete.
13926 Chapter 2 Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V. / M.H. 89.00 Each
8 -14-3 lamp /LED fitting from pole with brackets complete.
13926 Chapter 2 Dismantling the existing ceiling fan /exhaust fan / cabin fan / 31.00 Each
9 -14-4 bracket fan complete with accessories, G.I. down rod, frame etc.
and making the site clear.
Specification:
Rate In (Rs)
Item Description Rate Unit
13941 Chapter 3-1-11 Supplying & erecting dead weight pressure releasing valve for 393.00 Each
8 storage water heater with necessary materials.
13941 Chapter 3-1-12 Supplying & erecting vacuum relief valve for storage water heater 177.00 Each
9 with necessary materials.
13942 Chapter 3-1-13 Providing fibre reinforced PVC flexible pipe upto 1m length with 156.00 Each
0 brass locking nuts and washers and clips at both ends suitable for
hot water complete erected in an approved manner.
13942 Chapter 3-1-14 Erecting departmentally supplied water heater of 25 ltr capacity 396.00 Each
1 with wall fasteners, inlet & outlet pipes, NRV, etc. and marking Sr
No. and date of erection.
13942 Chapter 3-1-15 Erecting departmentally supplied water heater of 35/ 50 ltr 476.00 Each
2 capacity with wall fasteners, inlet & outlet pipes, NRV, etc. and
marking Sr No. and date of erection.
13942 Chapter 3-1-16 Supplying and erecting ISI mark heating element 2 / 3 kW suitable 805.00 Each
3 for water heater/ midget of any make any capacity.
13942 Chapter 3-1-17 Supplying and erecting ISI mark thermostat suitable for water 323.00 Each
4 heater / midget of any make, any capacity.
13942 Chapter 3-1-18 Dismantling unserviceable storage type water heater from site to 326.00 Each
5 workshop & back after duly repaired & Re-erecting the Repaired
storage water heater in position with necessary material complete
with To & Fro transportation.
Chapter 3-2 Air Conditioners (AP-AC)
13942 Chapter 3-2-1 Supplying and erecting window model mounted type room 25,176.00 Each
6 Air - conditioner 3 star 230/250V 50 cycles single phase
A.C.supply 1 TR capacity complete with gas R410A/R32 at position
in provided recess with wooden frame as per specification No.
AP-AC/WAC
13942 Chapter 3-2-2 Supplying and erecting window model mounted type room 29,737.00 Each
7 Air - conditioner 3 star 230/250 V 50 cycles single phase
A.C.supply 1.5 TR capacity complete with gas R410A/R32 at
position in provided recess with wooden frame as per specification
No. AP-AC/WAC
13942 Chapter 3-2-3 Supplying and erecting window model mounted type room 33,955.00 Each
8 Air - conditioner 5 star 230/250 V 50 cycles single phase
A.C.supply 1.5 TR capacity complete with gas R410A/R32 at
position in provided recess with wooden frame as per specification
No. AP-AC/WAC
Rate In (Rs)
Item Description Rate Unit
13942 Chapter 3-2-4 Supplying and erecting window model mounted type room 33,783.00 Each
9 Air-Conditioner 3 star 230/250 V 50 cycles single phase
A.C.supply 2 TR capacity complete with gas R410A/R32 at position
in provided recess with wooden frame as per specification No.
AP-AC/WAC
13943 Chapter 3-2-5 Providing modifications to the existing window for erection of 1,121.00 Each
0 window room air conditioner in position with use of teakwood,
grill, aluminum channel, glass as per requirement and filling
the gaps to maintain air tightness.
13943 Chapter 3-2-6 Supplying and erecting split type room Air conditioning unit 2 48,027.00 Each
1 TR 3 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hi-wall mounting type complete with Refrigerants
R410 A/R32 and COPPER CONDENSOR at position as per
specification no. AP-AC/SAC
13943 Chapter 3-2-7 Supplying and erecting split type room Air conditioning unit 2 58,433.00 Each
2 TR 5 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hi-wall mounting type complete with Refrigerants
R410 A /R32 and COPPER CONDENSOR at position as per
specification no. AP-AC/SAC
13943 Chapter 3-2-8 Supplying and erecting split type room Air conditioning unit 1.5 38,689.00 Each
3 TR 3 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hiwall / floor mounting type complete with
Refrigerent R410 A/R32 and COPPER CONDENSOR at position as
per specification no. AP-AC/SAC
13943 Chapter 3-2-9 Supplying and erecting split type room Airconditioning unit 1.5 43,634.00 Each
4 TR 5 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hiwall / floor mounting type complete with
Refrigerent R410 A/R32 and COPPER CONDENSOR at position as
per specification no. AP-AC/SAC
13943 Chapter 3-2-10 Supplying and erecting split type room Airconditioning unit 1 33,644.00 Each
5 TR 3 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hi-wall / floor mounting type complete with
Refrigerent R410 A/R32 and COPPER CONDENSOR at position as
per specification no. AP-AC/SAC
13943 Chapter 3-2-11 Supplying and erecting split type room Airconditioning unit 1 33,375.00 Each
6 TR 5 star capacity 250V, 50 cycles, A.C. supply having 1 No of air
handling unit hi-wall / floor mounting type complete with
Refrigerent R410 A/R32 and COPPER CONDENSOR at position as
per specification no. AP-AC/SAC
Rate In (Rs)
Item Description Rate Unit
13943 Chapter 3-2-12 Providing and pasting superior quality Sun control film on glass to 1,109.00 Sq.m
7 achieve better cooling effect having 1.5 / 2 mm thickness, ultra
violet transmittance less than 2% and solar heat rejection 78% in
approved manner.
13943 Chapter 3-2-13 Supplying and erecting split type room Airconditioning unit 2.5 55,712.00 Each
8 TR capacity with R410A/R32 gas 230/ 415V, 50 cycles, A.C.
supply having 1 No of air handling unit (Mega spilt) Hi-wall
mounting type complete at position as per specification No.
AP-AC/SAC
13943 Chapter 3-2-14 Supplying and erecting split type room Airconditioning unit 64,321.00 Each
9 3TR capacity with R410A/R32 gas 415 V, 50 cycles, A.C. supply
having 1 No of air handling unit (Mega spilt) mounting type
complete at position as per specification No. AP-AC/SAC
13944 Chapter 3-2-15 Supplying & erecting copper pipe suitable for refrigeration system 232.00 Meter
0 having 22 guage thickness and inner dia / size 12 mm complete.
13944 Chapter 3-2-16 Supplying & erecting copper pipe suitable for refrigeration system 313.00 Meter
1 having 22 guage thickness and inner dia / size 16 mm complete.
13944 Chapter 3-2-17 Supplying & erecting copper pipe suitable for refrigeration system 531.00 Meter
2 having 22 gauge thickness and inner dia / size 22 mm complete.
13944 Chapter 3-2-18 Supplying & erecting copper pipe suitable for refrigeration system 775.00 Meter
3 having 22 guage thickness and inner dia / size 32 mm complete.
13944 Chapter 3-2-19 Supplying & erecting copper pipe suitable for refrigeration system 980.00 Meter
4 having 22 guage thickness and inner dia / size 35 mm complete.
13944 Chapter 3-2-20 Supplying & erecting copper pipe suitable for refrigeration system 1,136.00 Meter
5 having 22 guage thickness and inner dia / size 42 mm Complete.
13944 Chapter 3-2-21 Supplying & erecting cassate type split room airconditioning unit 73,320.00 Each
6 1.5 TR capacity 230/250 V ,50 cycles ,AC supply having 1 No air
handling unit unit false ceiling mounting type complete with gas
R32/R410A at position as per specification without copper piping
and drainage pipe.
13944 Chapter 3-2-22 Supplying & erecting cassate type split room airconditioning unit 2 83,914.00 Each
7 TR capacity 230/250 V ,50 cycles ,AC supply having 1 No air
handling unit unit false ceiling mounting type complete with gas
R32/R410A at position as per specification without copper piping
and drainage pipe.
13944 Chapter 3-2-23 Supplying & erecting cassate type split room airconditioning unit 3 1,15,816.00 Each
8 TR capacity 230V /415 V ,50 cycles ,AC supply having 1 No air
handling unit unit false ceiling mounting type complete with gas
R32/R410A at position as per specification without copper piping
Electrical - 2018-2019 and drainage pipe.
- 01/04/2018 - Page 55 of 259 05/06/18 12:15
Chapter 3
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13946 Chapter 3-4-2 Supplying evaporative air cooler (desert cooler) with galvanised 7,511.00 Each
3 steel body 230/250 Volts, 50 cycles,normal cooling capacity of 70
cu.m per minute with 15" exhaust fan ,min 68 litre water capacity
tank complete as per specification No. AP-WCR/DAC
13946 Chapter 3-4-3 Supplying evaporative air cooler (desert cooler) with galvanised 10,075.00 Each
4 steel body 230/250 Volts, 50 cycles, normal cooling capacity of 80
cu.m per minute with 18" exhaust fan ,min 84 litre water capacity
tank as per specification No. AP-WCR/DAC
Chapter 3-5 Water Purifiers (WPF)
13946 Chapter 3-5-1 Supplying and erecting ultra violet storage type water purifier with 18,413.00 Each
5 softener for safe drinking water consisting of UV germicidal tube
of 8W capacity choke made of copper wire and two indicator
lamps with output of purified water 8 Ltr/min with activated carbon
filter and softener operating on 230 V single phase A.C. supply.
13946 Chapter 3-5-2 Supplying and erecting ultra violet water purifier with softener for 8,131.00 Each
6 safe drinking water consisting of UV germicidal tube of 8W
capacity choke made of copper wire and two indicator lamps &
with dual function cartritge with output of purified water 2 Ltr/min
with activated carbon filter and softener operating on 230 V single
phase A.C. supply.
Chapter 3-6 Inverter (AP-INV)
13946 Chapter 3-6-1 Supplying, installing, testing & commissioning of 600 VA Digital 6,311.00 Each
7 pure sine wave inverter based on IGBT technology single phase
230V,50 Hz complete as per specification no. AP-INV (Without
batteries)
13946 Chapter 3-6-2 Supplying, installing, testing & commissioning of 800 VA Digital 7,516.00 Each
8 pure sine wave inverter based on IGBT technology single phase
230V,50 Hz complete as per specification no. AP-INV (Without
batteries)
13946 Chapter 3-6-3 Supplying, installing, testing & commissioning of 1400 VA Digital 10,198.00 Each
9 pure sine wave inverter based on IGBT technology single phase
230V,50 Hz complete as per specification no. AP-INV (Without
batteries)
13947 Chapter 3-6-4 Supplying, installing, testing & commissioning of 2500 VA Digital 22,231.00 Each
0 pure sine wave inverter based on IGBT technology single phase
230V,50 Hz complete as per specification no. AP-INV (Without
batteries)
Chapter 3-7 On line UPS (AP-UPS)
Rate In (Rs)
Item Description Rate Unit
13947 Chapter 3-7-1 Supplying & erecting On line UPS pure sine wave of 1 kVA capacity 33,273.00 Each
1 complete with standard features, along with necessary SMF
batteries for 30 mins. battery backup, as per specification No.
AP-UPS
13947 Chapter 3-7-2 Supplying & erecting On line UPS pure sine wave of 2 kVA 46,542.00 Each
2 capacity complete with standard features, along with necessary
SMF batteries for 30 mins battery backup, as per specification No.
AP-UPS
13947 Chapter 3-7-3 Supplying & erecting On line UPS pure sine wave of 3 kVA 56,763.00 Each
3 capacity complete with standard features, along with necessary
SMF batteries for 30 mins battery backup, as per specification No.
AP-UPS
13947 Chapter 3-7-4 Supplying & erecting On line UPS pure sine wave of 5 kVA 70,831.00 Each
4 capacity complete with standard features, along with necessary
SMF batteries for 30 mins battery backup, as per specification No.
AP-UPS
13947 Chapter 3-7-5 Supplying & erecting On line UPS pure sine wave of 6 kVA 1,15,300.00 Each
5 capacity complete with standard features, along with necessary
SMF batteries for 30 mins battery backup, as per specification
No. AP-UPS
13947 Chapter 3-7-6 Supplying & erecting On line UPS pure sine wave of 8 kVA 1,47,947.00 Each
6 capacity complete with standard features,along with necessary
SMF batteries for 30 mins battery backup, as per specification
No. AP-UPS
13947 Chapter 3-7-7 Supplying & erecting On line UPS pure sine wave of 10 kVA 1,81,612.00 Each
7 capacity complete with standard features,along with necessary
SMF batteries for 30 mins battery backup, as per specification No.
AP-UPS
Chapter 3-8 Batteries for Inverter & UPS
13947 Chapter 3-8-1 Supplying and erecting 12 V/80AH TUBULAR Battery with battery 7,816.00 Each
8 terminal wire, duly charged complete with 36 months warranty
complete
13947 Chapter 3-8-2 Supplying and erecting 12 V/100AH TUBULAR Battery with battery 9,413.00 Each
9 terminal wire, duly charged complete with 36 months warranty
complete
13948 Chapter 3-8-3 Supplying and erecting 12 V/135AH TUBULAR Battery with battery 12,654.00 Each
0 terminal wire, duly charged complete with 36 months warranty
complete
Rate In (Rs)
Item Description Rate Unit
13948 Chapter 3-8-4 Supplying and erecting 12 V/150AH TUBULAR Battery with battery 13,114.00 Each
1 terminal wire, duly charged complete with 36 months warranty
complete
13948 Chapter 3-8-5 Supplying and erecting 12 V/180AH TUBULAR Battery with battery 14,421.00 Each
2 terminal wire, duly charged complete with 36 months warranty
complete
13948 Chapter 3-8-6 Supplying and erecting 12 V/200AH TUBULAR Battery with battery 17,223.00 Each
3 terminal wire, duly charged complete with 36 months warranty
complete
Chapter 3-9 Voltage Stabilizers (AP-VS)
13948 Chapter 3-9-1 Supplying and erecting fully automatic line voltage stabilizer buck 2,279.00 Each
4 and boost type for operation on input voltage 160 to 270 V and
output voltage 200 to 250 V rated for 0.5 kVA maximum load and
with voltmeter, selector switch, 6A/16A flush type 3 pin socket for
output and with 3 core flexible cord and 3 pin 6/16 A plug top
suitable for refrigerator for continuous operation and marking Sr.
No. and date of erection.
13948 Chapter 3-9-2 Supplying and erecting fully automatic line Voltage stabilizer, buck 2,532.00 Each
5 and boost type for operation on input voltage 160 to 270V and
output voltage 200 to 250V rated for, 1 kVA maximum load and
with voltmeter, selector switch, 6A/16A flush type 3 pin socket for
output and with 3 core flexible cord and 3 pin 6/16A plug top
suitable for Water Cooler below 120 liter cooling capacity, and
marking Sr. No. and date of erection.
13948 Chapter 3-9-3 Supplying and erecting fully automatic line Voltage stabilizer, buck 3,018.00 Each
6 and boost type for operation on input voltage 160 to 270 V and
output voltage 200 to 250 V rated for, 3 kVA maximum load and
with voltmeter, selector switch, 6A/16A flush type 3 pin socket for
output and with 3 core flexible cord and 3 pin 6/16 A plug top
suitable for Air Conditioner of 1 TR / Water Cooler of 120 liter
cooling capacity and above, and marking Sr. No. and date of
erection.
13948 Chapter 3-9-4 Supplying and erecting fully automatic line Voltage stabilizer, buck 5,135.00 Each
7 and boost type for operation on input voltage 160 to 270 V and
output voltage 200 to 250 V rated for, 4 kVA maximum load and
with voltmeter, selector switch, 6A/16A flush type 3 pin socket for
output and with 3 core flexible cord and 3 pin 6/16 A plug top
suitable for Air Conditioner of 1.5 TR, and marking Sr. No. and
date of erection.
Rate In (Rs)
Item Description Rate Unit
13948 Chapter 3-9-5 Supplying and erecting fully automatic line Voltage stabilizer, buck 8,607.00 Each
8 and boost type for operation on input voltage 160 to 270 V and
output voltage 200 to 250 V rated for, 5 kVA maximum load and
with voltmeter, selector switch, 6A/16A flush type 3 pin socket for
output and with 3 core flexible cord and 3 pin 6/16 A plug top
suitable for Air Conditioner of 2.0 TR, and marking Sr. No. and
date of erection.
Chapter 3-10 Dismantling
13948 Chapter 3-10-1 Dismantling the existing electric Geyser or storage type water 139.00 Each
9 heater of any size along with plumbing connections and making
the site clear.
13949 Chapter 3-10-2 Dismantling the existing window type air conditioner of any type 330.00 Each
0 and capacity safely without any damages and making the site
clear.
13949 Chapter 3-10-3 Dismantling the existing split type air conditioner of any type and 683.00 Each
1 capacity safely without any damages and making the site clear.
Chapter 3-11 Accessories for AC & Water cooler
13949 Chapter 3-11-1 providing servicing of 1/1.5/2 /3 Ton capacity split / Window 441.00 Per Job
2 Airconditioner with all necessary material. Job includes checking of
performance of unit, cleaning of filters of indoor unit, cleaning of
outdoor unit with blower ,checking of electrical connection of
indoor as well as outdoor unit and submitting report to Engineer
incharge as per specification AP-SER
13949 Chapter 3-11-2 Providing Annual comprehensive maintenance contract for 1 ton 5,403.00 Year
3 split/window unit as per terms and conditions. Job includes 1)
Quarterly servicing 2) on call repair 3) replacement of all spares
within 24 hours .The job exclude sheet metal work and plastic
material as per specification AP-SER
13949 Chapter 3-11-3 Providing Annual comprehensive maintenance contract for 1.5 ton 5,980.00 Year
4 split/window unit as per terms and conditions. Job includes 1)
Quarterly servicing 2) on call repair 3) replacement of all spares
within 24 hours 4) Sending standby manpower for VIP movement
The job exclude sheet metal work and plastic material as per
specification AP-SER
13949 Chapter 3-11-4 Providing Annual comprehensive maintenance contract for 2 ton 7,018.00 Year
5 split/window unit as per terms and conditions. Job includes 1)
Quarterly servicing 2) on call repair 3) replacement of all spares
within 24 hours 4) Sending standby manpower for VIP movement
The job exclude sheet metal work and plastic materialas per
specification AP-SER
Electrical - 2018-2019 - 01/04/2018 - Page 61 of 259 05/06/18 12:15
Chapter 3
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13949 Chapter 3-11-5 Providing Annual comprehensive maintenance contract for 3 ton 7,690.00 Year
6 split/window unit as per terms and conditions. Job includes 1)
Quarterly servicing 2) on call repair 3) replacement of all spares
within 24 hours 4) Sending standby manpower for VIP movement
The job exclude sheet metal work and plastic material as per
specification AP-SER
13949 Chapter 3-11-6 Dismantling existing unservicable Rotary Compressor of air 8,366.00 Per Job
7 conditioner ,1 TR capacity and replacing it by new one of same
capacity with guarantee for one year.
13949 Chapter 3-11-7 Dismantling existing unservicable Rotary Compressor of air 9,661.00 Per Job
8 conditioner ,1.5 TR capacity and replacing it by new one of same
capacity with guarantee for one year.
13949 Chapter 3-11-8 Dismantling existing unservicable Rotary Compressor of air 10,477.00 Per Job
9 conditioner, 2TR capacity and replacing it by new one of same
capacity with guarantee for one year.
13950 Chapter 3-11-9 Dismantling existing unservicable Rotary Compressor of air 16,951.00 Per Job
0 conditioner, 3 TR capacity and replacing it by new one of same
capacity with guarantee for one year.
13950 Chapter Providing flushing out cooling coil and condensor coil of 690.00 Per Job
1 3-11-10 airconditioner unit ,gas pipes internally with dry Nitrogen pressure
in an approved manner
13950 Chapter Providing brazing to copper pipes and checking leakages in the 690.00 Per Job
2 3-11-11 split/ window unit duly with dry nitrogen pressure in an approved
manner
13950 Chapter Providing replacement of unservicable starting Relay for AC unit. 198.00 Each
3 3-11-12
13950 Chapter Providing replacement of unservicable Starting Capacitor for A/C 571.00 Each
4 3-11-13 unit
13950 Chapter Providing replacement of unservicable Running Capacitor for A/C 571.00 Each
5 3-11-14 unit
13950 Chapter Providing Replacement of unservicable fan motor Capacitor for 145.00 Each
6 3-11-15 A/C unit
13950 Chapter Providing Replacement of unservicable PCB for A/C unit 4,944.00 Each
7 3-11-16
13950 Chapter Providing repair of faulty PCB for A/C unit 897.00 Each
8 3-11-17
Rate In (Rs)
Item Description Rate Unit
13950 Chapter Providing new fan motor for condensor for A/C unit 4,577.00 Each
9 3-11-18
13951 Chapter Providing new fan motor for Room unit for A/C unit 1,115.00 Each
0 3-11-19
13951 Chapter Providing new fan blade outdoor unit for A/C unit 948.00 Each
1 3-11-20
13951 Chapter Providing replacement of blower of indoor unit for A/C unit 1,244.00 Each
2 3-11-21
13951 Chapter Providing replacement of remote of indoor unit for A/C unit 1,128.00 Each
3 3-11-22
13951 Chapter Providing vaccumising the airconditioner system and charging with 709.00 kg
4 3-11-23 R-22 refrigerent gas for A/C unit
13951 Chapter Providing vaccumising the airconditioner system and charging with 920.00 kg
5 3-11-24 R-410A/R32 refrigerent gas for A/C unit
13951 Chapter Providing vaccumising the airconditioner system to 200 micron and 1,096.00 Per Job
6 3-11-25 charging with R-22 refrigerent gas for 1 Ton window/split A/C
unit.
13951 Chapter Providing vaccumising the airconditioner system to 200 micron and 1,318.00 Per Job
7 3-11-26 charging with R-22 refrigerent gas for 1.5 Ton window/split A/C
unit.
13951 Chapter Providing vaccumising the airconditioner system to 200 micron and 1,571.00 Per Job
8 3-11-27 charging with R-22 refrigerent gas for 2 Ton window/split A/C
unit.
13951 Chapter Providing vaccumising the airconditioner system to 200 micron and 2,597.00 Per Job
9 3-11-28 charging with R-22 refrigerent gas for 3 Ton window/split A/C
unit.
13952 Chapter Dismantling existing unservicable Compressor of 40 litre 7,261.00 Per Job
0 3-11-29 cooling capacity water cooler replacing it by new one of same
capacity with guarantee for one year .
13952 Chapter Dismantling existing unservicable Compressor of 60 litre cooling 8,070.00 Per Job
1 3-11-30 capacity water cooler replacing it by new one of same capacity
with guarantee for one year .
13952 Chapter Dismantling existing unservicable Compressor of 150 litre 8,910.00 Per Job
2 3-11-31 cooling capacity water cooler replacing it by new one of same
capacity with guarantee for one year .
13952 Chapter Dismantling existing unservicable condensor coil of 40/80/150 5,782.00 Per Job
3 3-11-32 litre cooling capacity water cooler replacing it by new one of same
capacity and testing to the satisfaction of site engineer for cooling
Electrical - 2018-2019 and
- 01/04/2018 -
with guarantee Page 63 of 259
for one year 05/06/18 12:15
Chapter 3
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13954 Chapter 4-2-2 Supplying and erecting G.I pipe 20 mm dia B class with resin 315.00 Meter
1 bonded flap rock wool/glass wool insulation, with necessary
material as per specification No. (ESD-HWP/TGP)
13954 Chapter 4-2-3 Supplying and erecting G.I pipe 25 mm dia B class with resin 464.00 Meter
2 bonded flap rock wool/glass wool insulation, with necessary
material as per specification No. (ESD-HWP/TGP)
13954 Chapter 4-2-4 Supplying and erecting G.I pipe 32 mm dia B class with resin 534.00 Meter
3 bonded flap rock wool/glass wool insulation, with necessary
material as per specification No. (ESD-HWP/TGP)
13954 Chapter 4-2-5 Supplying and erecting G.I pipe 40 mm dia B class with resin 601.00 Meter
4 bonded flap rock wool/glass wool insulation, with necessary
material as per specification No. (ESD-HWP/TGP)
13954 Chapter 4-2-6 Supplying and erecting G.I pipe 50 mm dia B class with resin 761.00 Meter
5 bonded flap rock wool/glass wool insulation, with necessary
material as per specification No. (ESD-HWP/TGP
13954 Chapter 4-2-7 Supplying and erecting 12/16 mm (ID/OD) polyethylene composite 169.00 Meter
6 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
13954 Chapter 4-2-8 Supplying and erecting 16/20 mm (ID/OD) polyethylene composite 194.00 Meter
7 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
13954 Chapter 4-2-9 Supplying and erecting 20/25 mm (ID/OD) polyethylene composite 244.00 Meter
8 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
13954 Chapter 4-2-10 Supplying and erecting 25/32 mm (ID/OD) polyethylene composite 316.00 Meter
9 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
13955 Chapter 4-2-11 Supplying and erecting 32/40 mm (ID/OD) polyethylene composite 443.00 Meter
0 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
13955 Chapter 4-2-12 Supplying and erecting 40/50 mm (ID/OD) polyethylene composite 627.00 Meter
1 pipe duly joined by compression/crimp fitted accessories, with
internal as well as external end sealing arrangement for Solar
Water Heater System as per specification No. (ESD-HWP/PCP)
Rate In (Rs)
Item Description Rate Unit
13955 Chapter 4-2-13 Supplying and erecting Elastomeric Nitrile rubber / foam tube 46.00 Meter
2 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 6 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-14 Supplying and erecting Elastomeric Nitrile rubber / foam tube 52.00 Meter
3 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 9 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-15 Supplying and erecting Elastomeric Nitrile rubber / foam tube 57.00 Meter
4 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 12 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-16 Supplying and erecting Elastomeric Nitrile rubber / foam tube 67.00 Meter
5 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 16 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-17 Supplying and erecting Elastomeric Nitrile rubber / foam tube 77.00 Meter
6 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 19 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-18 Supplying and erecting Elastomeric Nitrile rubber / foam tube 84.00 Meter
7 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 22 mm for Solar Water Heater System as per specification no
ESD-ENR
13955 Chapter 4-2-19 Supplying and erecting Elastomeric Nitrile rubber / foam tube 102.00 Meter
8 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 28 mm for Solar Water Heater System as per specification no
ESD-EN
13955 Chapter 4-2-20 Supplying and erecting Elastomeric Nitrile rubber / foam tube 106.00 Meter
9 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 32 mm for Solar Water Heater System as per specification no
ESD-ENR
Rate In (Rs)
Item Description Rate Unit
13956 Chapter 4-2-21 Supplying and erecting Elastomeric Nitrile rubber / foam tube 122.00 Meter
0 type sleeves for over coating and insulating on provided PCP
pipes / copper pipes having 9 mm thickness and inner diameter /
sizes 42 mm for Solar Water Heater System as per specification no
ESD-ENR
Chapter 4-3 Solar Lighting (ESD-SOL)
13956 Chapter 4-3-1 Supplying and Erecting Solar Home light System with 2 white LED 7,074.00 Each
1 Luminary, 12V 12AH SMF battery/Appropriate Lithium Battery, 20
Wp SPV Module with module mounting hardware control electronic
connecting wire switches Battery box as per specification no
ESD-SOL/SHL
13956 Chapter 4-3-2 Supplying and Erecting Solar Home light System with 3 white LED 10,155.00 Each
2 Luminary, 12v, 20AH SMF battery/Appropriate Lithium Battery, 30
Wp SPV Module with module mounting hardware control electronic
connecting wire switches Battery box as per specification no
ESD-SOL/SHL
13956 Chapter 4-3-3 Supplying and erecting Solar panel comprising high efficiency 4,809.00 Each
3 mono-crystalline / multi crystalline Photovoltaic Cell 100 Wp, 12V,
with necessary clamps and module frame on existing structure as
per specification no. ESD-SOL/CELL
13956 Chapter 4-3-4 Supplying and erecting Solar panel comprising high efficiency 9,586.00 Each
4 mono-crystalline / multi crystalline Photovoltaic Cell 250 Wp, 24V
with necessary clamps and module frame on existing structure as
per specification no. ESD-SOL/CELL
13956 Chapter 4-3-5 Supplying and erecting Solar panel comprising high efficiency 10,760.00 Each
5 mono-crystalline / multi crystalline Photovoltaic Cell 300Wp, 24V,
with necessary clamps and module frame on existing structure as
per specification no. ESD-SOL/CELL
13956 Chapter 4-3-6 Supplying and erecting approved make battery with capacity of 6,298.00 Each
6 12 V 40 AH with duty cycle 10-12 hrs suitable to charge on PV cell
with necessary wiring connections erected in powder coated
protection box with stand and nut bolts as per specification no.
ESD-SOL/BAT
13956 Chapter 4-3-7 Supplying and erecting approved make battery with capacity of 7,925.00 Each
7 12 V 75 AH with duty cycle 10-12 hrs suitable to charge on PV cell
with necessary wiring connections erected in powder coated
protection box with stand and nut bolts as per specification no.
ESD-SOL/BAT
13956 Chapter 4-3-8 Supplying and erecting approved make battery with capacity of 14,003.00 Each
8 12 V 150 AH with duty cycle 10-12 hrs suitable to charge on PV
Electrical - 2018-2019 cell with necessary
- 01/04/2018 - wiring connections erected in powder coated
Page 68 of 259 05/06/18 12:15
Chapter 4 protection box with stand and nut bolts as per specification no.
ESD-SOL/BAT
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13957 Chapter 4-4-2 Supplying and erecting two pole power contactor 250V 12A for 1,133.00 Each
4 time switch complete erected on wooden block/provided box, with
necessary materials.
13957 Chapter 4-4-3 Supplying and erecting two pole power contactor 250V 32A for 3,047.00 Each
5 time switch complete erected on wooden block/provided box, with
necessary materials.
13957 Chapter 4-4-4 Supplying and erecting 4 pole power contactor 440V 16A 1,228.00 Each
6 for time switch complete erected on wooden block/provided box,
with necessary materials.
13957 Chapter 4-4-5 Supplying and erecting 4 pole power contactor 440V 40A 2,969.00 Each
7 for time switch complete erected on wooden block/provided box,
with necessary materials.
13957 Chapter 4-4-6 Supplying and erecting Programmable Digital Almanac Timer 6,546.00 Each
8 Microcontroller based with real time clock to operate on derived
switching “ON” & switching “OFF” street light as per daily sunset
and sunrise respectively automatically having 4 digit LED
continuous time display, relay output 230V / 10A with 10 Hrs
battery backup and manual over drive facility capable to
drive different capacity contactors timer erected in MS box in an
approved manner.
13957 Chapter 4-4-7 Providing and fixing H.D.P.E container one piece moulded water 9.00 litre
9 tank made out of high density polyethylene and built corrugated
inclusive of delivery up to destination hoisting and fixing of
accessories such as inlet,outlet overflow pipe inclusive of all tanks
capacity up to 20000 liters.
Chapter 4-5 Rooftop OFF Grid Solar Systems (ESD-RT-OFG)
13958 Chapter 4-5-1 Supplying, Installing,Testing and commissioning of 1 KWp Offgrid 1,29,829.00 Per Job
0 Solar Power Pack with GI mounting structure and inter connecting
wires / cables along with battery bank of min. 600 AH capacity,
SPV Modules of 1 KWp, Solar power Invertor of min. 1 KVA
capacity complete. With 5 years on site performance warranty as
per Specification no. ESD-RT-OFG
13958 Chapter 4-5-2 Supplying, Installing,Testing and commissioning of 1.5 KWp Off 1,92,542.00 Per Job
1 Grid Solar Power Pack with GI mounting structure and inter
connecting wires / cables along with battery bank of min. 900 AH
capacity, SPV Modules of 1.5 KWp, Solar power Invertor of min. 2
KVA capacity complete. With 5 years on site performance warranty
as per Specification no. ESD-RT-OFG
13958 Chapter 4-5-3 Supplying, Installing,Testing and commissioning of 2 KWp Offgrid 2,70,406.00 Per Job
2 Solar Power Pack with GI mounting structure and inter connecting
Electrical - 2018-2019 wires / cables along
- 01/04/2018 - with battery
Page bank
70 of of
259min. 1200 AH capacity, 05/06/18 12:15
Chapter 4 SPV Modules of 2 KWp, Solar power Invertor of min. 2 KVA
capacity complete. With 5 years on site performance warranty as
per Specification no. ESD-RT-OFG
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13958 Chapter 4-6-3 Supplying, Installing,Testing and commissioning of 3 KWp capacity 1,73,880.00 Per Job
9 On-Grid Solar Power Pack with GI mounting structure and inter
connecting wires / cables without battery bank SPV Modules of 3
KWp, Solar power Conditioning unit of min. 3 KVA capacity
complete. With 5 years on site performance warranty as per
Specification no ESD-RT-ONG
13959 Chapter 4-6-4 Supplying, Installing,Testing and commissioning of 5 KWp capacity 3,25,776.00 Per Job
0 On-Grid Solar Power Pack with GI mounting structure and inter
connecting wires / cables without battery bank SPV Modules of 5
KWp, Solar power Conditioning unit of min. 5 KVA capacity
complete. With 5 years on site performance warranty as per
Specification no ESD-RT-ONG
13959 Chapter 4-6-5 Supplying, Installing,Testing and commissioning of 7.5 KWp 4,87,196.00 Per Job
1 capacity On-Grid Solar Power Pack with GI mounting structure and
inter connecting wires / cables without battery bank SPV Modules
of 7.5 KWp, Solar power Conditioning unit of min. 7.5 KVA capacity
complete. With 5 years on site performance warranty as per
Specification no ESD-RT-ONG
13959 Chapter 4-6-6 Supplying, Installing,Testing and commissioning of 10 KWp 6,42,253.00 Per Job
2 capacity On-Grid Solar Power Pack with GI mounting structure and
inter connecting wires / cables without battery bank SPV Modules
of 10 KWp, Solar power Conditioning unit of min. 10 KVA capacity
complete. With 5 years on site performance warranty as per
Specification no ESD-RT-ONG
Chapter 4-7 Solar Water Pump Systems (ESD-SWPS)
13959 Chapter 4-7-1 Supplying, Installing,Testing and commissioning of 1 HP capacity 1,10,160.00 Per Job
3 AC/DC Solar water pump (SPV pump), comprising of min. 1 KWp
capacity multi crystalline SPV modules mounted on GI Structure
with necessary hardware with controller, suitable size HDPE
delivery water pipe line up to 60mtr length inside or above water
tank/borewell with necessary control valves and necessary power
supply cable of appropriate size complete. With 5 years on site
performance warranty as per specification no. ESD-SWPS
13959 Chapter 4-7-2 Supplying, Installing,Testing and commissioning of 2 HP capacity 2,12,338.00 Per Job
4 AC/DC Solar water pump (SPV pump), comprising of min. 2 KWp
capacity multi crystalline SPV modules mounted on GI Structure
with necessary hardware with controller, suitable size HDPE
delivery water pipe line up to 60mtr length inside or above water
tank/borewell with necessary control valves and necessary power
supply cable of appropriate size complete. With 5 years on site
performance warranty as per specification no. ESD-SWPS
Rate In (Rs)
Item Description Rate Unit
13959 Chapter 4-7-3 Supplying, Installing,Testing and commissioning of 3 HP capacity 2,58,379.00 Per Job
5 AC/DC Solar water pump (SPV pump), comprising of min. 3 KWp
capacity multi crystalline SPV modules mounted on GI Structure
with necessary hardware with controller, suitable size HDPE
delivery water pipe line up to 60mtr length inside or above water
tank/borewell with necessary control valves and necessary power
supply cable of appropriate size complete. With 5 years on site
performance warranty as per specification no. ESD-SWPS
13959 Chapter 4-7-4 Supplying, Installing,Testing and commissioning of 5 HP capacity 4,28,806.00 Per Job
6 AC/DC Solar water pump (SPV pump), comprising of min. 5 KWp
capacity multi crystalline SPV modules mounted on GI Structure
with necessary hardware with controller, suitable size HDPE
delivery water pipe line up to 60 mtr length inside or above water
tank/borewell with necessary control valves and necessary power
supply cable of appropriate size complete. With 5 years on site
performance warranty as per specification no. ESD-SWPS
13959 Chapter 4-7-5 Supplying, Installing,Testing and commissioning of 7.5 HP capacity 6,00,238.00 Per Job
7 AC/DC Solar water pump (SPV pump), comprising of min. 7.5
KWp capacity multi crystalline SPV modules mounted on GI
Structure with necessary hardware with controller, suitable size
HDPE delivery water pipe line up to 60 mtr length inside or above
water tank/borewell with necessary control valves and necessary
power supply cable of appropriate size complete. With 5 years on
site performance warranty as per specification no. ESD-SWPS
13959 Chapter 4-7-6 Supplying, Installing,Testing and commissioning of 10 HP capacity 7,70,068.00 Per Job
8 AC/DC Solar water pump (SPV pump), comprising of min. 10 KWp
capacity multi crystalline SPV modules mounted on GI Structure
with necessary hardware with controller, suitable size HDPE
delivery water pipe line up to 60 mtr length inside or above water
tank/borewell with necessary control valves and necessary power
supply cable of appropriate size complete. With 5 years on site
performance warranty as per specification no. ESD-SWPS
Chapter 4-8 Dismantling
13959 Chapter 4-8-1 Dismantling the existing solar water heating system upto 500 1,746.00 Each
9 LPD Capacity along with piping etc. from RoofTop & Bringing Down
to ground
13960 Chapter 4-8-2 Dismantling the existing solar water heating system above 500 to 2,796.00 Each
0 1000 LPD Capacity along with piping etc. from RoofTop &
Bringing Down to ground.
Specification:
Rate In (Rs)
Item Description Rate Unit
13961 Chapter 5-1-13 Supplying and erecting Triple pole metal/ iron clad switch and fuse 5,149.00 Each
3 415/ 500V 100A with neutral link on angle iron / G.I. frame as per
specification No. SW-SWR/MTP
13961 Chapter 5-1-14 Supplying and erecting Triple pole metal clad/ iron clad 8,663.00 Each
4 rewireable fuse 415/ 500V 200A with neutral link on angle iron /
G.I. frame as per specification No. SW-SWR/MTP
13961 Chapter 5-1-15 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 4,187.00 Each
5 415/ 500V 63A with neutral link with ISI marked HRC fuses on
angle iron / G.I. frame as per specification No.SW-SWR/TPHRC
13961 Chapter 5-1-16 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 5,958.00 Each
6 415/ 500 V.100 A. with neutral link with ISI marked HRC fuses on
angle iron / G.I. frame as per specification no. SW-SWR/TPHRC
13961 Chapter 5-1-17 Supplying and erecting Triple pole metal/ iron clad HRC fuse switch 8,171.00 Each
7 415/ 500V 200A with neutral link with ISI marked HRC fuses on
angle iron / G.I. frame as per specification No. SW-SWR/TPHRC
13961 Chapter 5-1-18 Supplying and erecting Triple pole metal / iron clad HRC fuse 9,950.00 Each
8 switch 415/ 500V 300-320 A with neutral link with ISI marked
HRC fuses, on angle iron / G.I. frame as per specification No.
SW-SWR/TPHRC
13961 Chapter 5-1-19 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 15,329.00 Each
9 500V 400A with neutral link with ISI marked HRC fuses, on angle
iron / G.I. frame as per specification No. SW-SWR/TPHRC
13962 Chapter 5-1-20 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 18,811.00 Each
0 500V 500A with neutral link with ISI marked HRC fuses, on angle
iron / G.I. frame as per specification No. SW-SWR/TPHRC
13962 Chapter 5-1-21 Supplying and erecting Triple pole metal clad HRC fuse switch 415/ 21,568.00 Each
1 500V 630A with neutral link with ISI marked HRC fuses, on angle
iron / G.I. frame. As per specification No. SW-SWR/TPHRC
13962 Chapter 5-1-22 Supplying and erecting Triple pole metal clad HRC fuse switch 31,117.00 Each
2 415 / 500V 800A with neutral link with ISI marked HRC fuses, on
angle iron / G.I. frame as per specification No. SW-SWR/TPHRC
13962 Chapter 5-1-23 Supplying & erecting Four pole Iron clad/metal clad ON LOAD 1,953.00 Each
3 change over switch 16A, 415 / 500V erected on angle iron /
G.I. frame approved make.
13962 Chapter 5-1-24 Supplying & erecting Four pole Iron clad/metal clad ON LOAD 2,383.00 Each
4 change over switch 40A, 415 / 500V erected on angle iron /
G.I. frame approved make.
Rate In (Rs)
Item Description Rate Unit
13962 Chapter 5-1-25 Supplying & erecting Four pole Iron clad/metal clad ON LOAD 4,316.00 Each
5 change over switch 63A, 415/500V erected on angle iron / G.I.
frame approved make.
13962 Chapter 5-1-26 Supplying & erecting on load four pole Iron clad/metal clad ON 7,764.00 Each
6 LOAD change over switch 100A, 415 / 500V erected on angle iron /
G.I. frame approved make.
13962 Chapter 5-1-27 Supplying & erecting on load Four pole Iron clad/metal clad 8,607.00 Each
7 ON LOAD change over switch 200A, 415/500V erected on
angle iron / G.I. frame approved make.
13962 Chapter 5-1-28 Supplying & erecting on load Four pole Iron clad/metal clad ON 13,307.00 Each
8 LOAD change over switch 320A, 415/500V erected on angle
iron / G.I. frame approved make.
13962 Chapter 5-1-29 Supplying & erecting on load Four pole Iron clad/metal clad 19,243.00 Each
9 ON LOAD change over switch 400A, 415/500V erected on
angle iron / G.I. frame approved make.
13963 Chapter 5-1-30 Supplying and erecting two pole iron clad/ metal clad ON LOAD 1,022.00 Each
0 change over switch 16A 240V erected on angle iron / G.I. frame
approved make and duly connected with suitable wire leads.
13963 Chapter 5-1-31 Supplying and erecting two pole iron clad/ metal clad ON LOAD 1,423.00 Each
1 change over switch 32A 240V erected on angle iron / G.I.
frame approved make and duly connected with suitable wire
leads.
13963 Chapter 5-1-32 Supplying and erecting approved make ON LOAD Four Pole 35,072.00 Each
2 Automatic Transfer Switch suitable for 415V, 50 Hz, 100A capacity
conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with
Enclosure, automatic/manual inbuilt Time delay, high transfer
speed, excellent breaking capacity, superior making capacity,
compact & light weight, erected on provided angle iron /G.I. frame
and connected with provided leads.
13963 Chapter 5-1-33 Supplying and erecting approved make ON LOAD Four Pole 45,710.00 Each
3 Automatic Transfer Switch suitable for 415V, 50 Hz, 160A capacity
conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with
Enclosure, automatic/manual inbuilt Time delay, high transfer
speed, excellent breaking capacity, superior making capacity,
compact & light weight, erected on provided angle iron / G.I.
frame and connected with provided leads.
13963 Chapter 5-1-34 Supplying and erecting approved make ON LOAD Four Pole 57,192.00 Each
4 Automatic Transfer Switch suitable for 415V, 50 Hz, 200A capacity
conforming to IEC: 60947-1 & IEC: 947-6-1/ IS: 13947-1, with
Enclosure, automatic/manual inbuilt Time delay, high transfer
Electrical - 2018-2019 speed, excellent
- 01/04/2018 - breaking Page
capacity,
76 of superior
259 making capacity, 05/06/18 12:15
Chapter 5 compact & light weight, erected on provided angle iron / G.I.
frame and connected with provided leads.
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13964 Chapter 5-2-6 Supplying and erecting metal clad distribution board approved 2,300.00 Each
2 make 415/500V, 3 way, 16A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-7 Supplying and erecting metal clad distribution board approved 2,523.00 Each
3 make 415/500V, 4 way, 16A per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-8 Supplying and erecting metal clad distribution board approved 2,930.00 Each
4 make 415/500V, 6 way, 16A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-9 Supplying and erecting metal clad distribution board approved 3,891.00 Each
5 make 415/500 V, 8 way, 16 A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-10 Supplying and erecting metal clad distribution board approved 2,887.00 Each
6 make 415/500V, 3 way, 32A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-11 Supplying and erecting metal clad distribution board approved 3,059.00 Each
7 make 415/500V, 4 way, 32A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-12 Supplying and erecting metal clad distribution board approved 4,039.00 Each
8 make 415/500V, 6 way, 32A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13964 Chapter 5-2-13 Supplying and erecting metal clad distribution board approved 5,082.00 Each
9 make 415/500V, 8 way, 32A. per way & neutral bar connector
complete erected on iron / G.I. frame/ wooden plank or Board
as per specification No. SW-SWR/MDB
13965 Chapter 5-2-14 Supplying and erecting mini feeder pillar triple pole with 200A 30,923.00 Each
0 FPMCCB as incomer and 2 outgoing circuits with HRC Fuse base
and Cartridge of 100A consists of aluminium bus bar 500 V 200
A. complete erected in 14 gauge CRCA sheet box with supporting
angles, self locks, gasket and slanting top to be erected on
provided foundation as per specification No. SW-SWR/MFP
13965 Chapter 5-2-15 Supplying and erecting mini feeder pillar triple pole with 300A 44,665.00 Each
1 FPMCCB as incomer and 3 outgoing circuits with HRC Fuse base
Electrical - 2018-2019 and Cartridge of
- 01/04/2018 - 100A consists of aluminium
Page 78 of 259 bus bar 500V 300A 05/06/18 12:15
Chapter 5 complete erected in 14 gauge CRCA sheet box with supporting
angles, self locks, gasket and slanting top to be erected on
provided foundation as per per specification No. SW-SWR/MFP
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13966 Chapter 5-3-13 Supplying, erecting & marking SPN MCB 40A, B-series (for 530.00 Each
9 lighting) in provided distribution board as per specification No.
SW-SWR/MCB
13967 Chapter 5-3-14 Supplying, erecting & marking TPMCB 6 A to 32A in provided 696.00 Each
0 distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-15 Supplying, erecting & marking TPMCB 40A to 63A in provided 925.00 Each
1 distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-16 Supplying, erecting & marking FPMCB 6A to 32A in provided 951.00 Each
2 distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-17 Supplying, erecting & marking FPMCB 40A to 63A in provided 1,231.00 Each
3 distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-18 Supplying, erecting & marking TPN MCB 6A to 32A, C- series in 889.00 Each
4 provided distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-19 Supplying, erecting & marking TPN MCB 40A to 63A, C- Series in 1,139.00 Each
5 provided distribution board as per specification No. SW-SWR/MCB
13967 Chapter 5-3-20 Supplying erecting and marking double pole isolator only switch 290.00 Each
6 version of miniature circuit breaker (Conforming to IS:8828
of1996) of 40A with required wiring connections and lugs etc. in
provided distribution board.
13967 Chapter 5-3-21 Supplying erecting and marking triple pole isolators only switch 517.00 Each
7 version of miniature circuit breaker of 40A with required wiring
connections and lugs etc. in provided distribution board.
13967 Chapter 5-3-22 Supplying erecting and marking Triple pole isolators only switch 581.00 Each
8 version of miniature circuit breaker of 63A with required wiring
connections and lugs etc. in provided distribution board.
13967 Chapter 5-3-23 Supplying erecting and marking Triple pole isolators only switch 660.00 Each
9 version of miniature circuit breaker of 100A with required wiring
connections and lugs etc. in provided distribution board.
13968 Chapter 5-3-24 Supplying erecting and marking Four pole isolators only switch 650.00 Each
0 version of miniature circuit breakers of 40A in provided distribution
board.
13968 Chapter 5-3-25 Supplying erecting and marking Four pole isolators only switch 659.00 Each
1 version of miniature circuit breakers of 63A in provided distribution
board.
13968 Chapter 5-3-26 Supplying erecting and marking Four pole isolators only switch 848.00 Each
2 version of miniature circuit breakers of 80/100A in provided
distribution board.
Rate In (Rs)
Item Description Rate Unit
13968 Chapter 5-3-27 Supplying, fixing and commissioning MCB type change over switch 1,042.00 Each
3 2 Pole, 25 Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
13968 Chapter 5-3-28 Supplying, fixing and commissioning MCB type change over switch 1,553.00 Each
4 2 Pole, 40 Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
13968 Chapter 5-3-29 Supplying, fixing and commissioning MCB type change over switch 1,796.00 Each
5 2 Pole, 63 Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
13968 Chapter 5-3-30 Supplying, fixing and commissioning MCB type change over switch 1,799.00 Each
6 4 Pole,25Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
13968 Chapter 5-3-31 Supplying, fixing and commissioning MCB type change over switch 2,769.00 Each
7 4 Pole,40Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
13968 Chapter 5-3-32 Supplying, fixing and commissioning MCB type change over switch 3,055.00 Each
8 4 Pole, 63Amps with 3 positions (I-O-II) with centre off position
as per specification No. SW-SWR/MCBCOS
Chapter 5-4 LT - MCBDBs (SW-MCBDB)
13968 Chapter 5-4-1 Supplying & erecting triple pole and neutral distribution board 1,811.00 Each
9 (TPNDB) surface/ flush mounted, suitable for SPMCB of 12 ways,
on iron / G.I. frame/wooden board.(Horizontal type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-2 Supplying & erecting triple pole and neutral distribution board 2,364.00 Each
0 (TPNDB) surface/ flush mounted suitable for SPMCB of 24 ways,
on iron / G.I. frame/wooden board.(Horizontal type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-3 Supplying & erecting triple pole and neutral distribution board 3,032.00 Each
1 (TPNDB) surface/ flush mounted suitable for SPMCB of 36 ways,
on iron / G.I. frame/wooden board.(Horizontal type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-4 Supplying & erecting triple pole and neutral distribution board 3,828.00 Each
2 (TPNDB) surface/ flush mounted SP /TP MCBs of total 12 ways, on
iron / G.I. frame/wooden board.(Vertical Busbar type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-5 Supplying & erecting triple pole and neutral distribution board 4,660.00 Each
3 (TPNDB) surface/ flush mounted SP / TP of total 24 ways on
iron / G.I. frame/wooden board. (Vertical Busbar type) as per
specification No. SW-SWR/MCBDB
Electrical - 2018-2019 - 01/04/2018 - Page 82 of 259 05/06/18 12:15
Chapter 5
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13969 Chapter 5-4-6 Supplying & erecting triple pole and neutral distribution board 6,222.00 Each
4 (TPNDB) surface/ flush mounted SP / TP MCB of total 36 ways on
iron / G.I. frame/wooden board (Vertical Busbar type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-7 Supplying & erecting triple pole and neutral distribution board 2,221.00 Each
5 (TPNDB) with door surface/ flush mounted SPMCB of 12 ways, on
iron / G.I. frame/wooden board.(Horizontal type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-8 Supplying & erecting triple pole and neutral distribution board 3,206.00 Each
6 (TPNDB) with door surface/ flush mounted SPMCB of 24 ways, on
iron/ G.I. frame/wooden board.(Horizontal type) as per
specification No. SW-SWR/MCBDB
13969 Chapter 5-4-9 Supplying & erecting triple pole and neutral distribution board 4,388.00 Each
7 (TPNDB) with door surface/ flush mounted SPMCB of 12
ways/phase (36 Poles) on iron/ G.I. frame/wooden board.
(Horizontal Busbar type) as per specification no. SW-SWR/MCBDB
13969 Chapter 5-4-10 Supplying & erecting triple pole and neutral distribution board 4,732.00 Each
8 (TPNDB) with door surface/ flush mounted SP / TP MCBs total 12
ways, on iron/ G.I. frame/wooden board.(Vertical Busbar type) as
per specification No. SW-SWR/MCBDB
13969 Chapter 5-4-11 Supplying & erecting triple pole and neutral distribution board 5,674.00 Each
9 (TPNDB) with door surface/ flush mounted SP / TP MCBs 24 Poles
on iron/ G.I. frame/wooden board. (Vertical Busbar type) as per
specification No. SW-SWR/MCBDB
13970 Chapter 5-4-12 Supplying & erecting triple pole and neutral distribution board 7,307.00 Each
0 (TPNDB) with door surface/ flush mounted SP / TP MCBs of total
36 ways on iron/ G.I. frame/wooden board. (Vertical Busbar type)
as per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-13 Supplying, erecting and marking enclosure Single pole and neutral 242.00 Each
1 distribution board (SPNDB) one way for SPMCB 1 No on iron/ G.I.
frame/wooden board as per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-14 Supplying and erecting single pole and neutral distribution board 717.00 Each
2 (SPNDB) surface/flush mounted with 2 ways for incoming and 2
ways for outgoing SPMCBs on iron/ G.I. frame/wooden board, as
per specification no. SW-SWR/MCBDB
13970 Chapter 5-4-15 Supplying and erecting single pole and neutral distribution board 803.00 Each
3 (SPNDB) surface/flush mounted with 2 ways for incoming and 6
ways for outgoing SP MCB’s on iron/ G.I. frame/wooden board as
per specification No. SW-SWR/MCBDB
Rate In (Rs)
Item Description Rate Unit
13970 Chapter 5-4-16 Supplying and erecting single pole and neutral distribution board 1,003.00 Each
4 (SPNDB) surface/flush mounted with 2 ways for incoming and 10
ways for outgoing SP MCB’s on iron/ G.I. frame/wooden board as
per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-17 Supplying and erecting single pole and neutral distribution board 966.00 Each
5 (SPNDB) with door surface/flush mounted with 2 ways for
incoming and 2 ways for outgoing SP MCB’s on iron/ G.I.
frame/wooden board as per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-18 Supplying and erecting single pole and neutral distribution board 1,139.00 Each
6 (SPNDB) with door surface/flush mounted with 2 ways for
incoming and 6 ways for outgoing SP MCB’s on iron/ G.I.
frame/wooden board as per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-19 Supplying and erecting single pole and neutral distribution board 1,393.00 Each
7 (SPNDB) with door surface/flush mounted with 2 ways for
incoming and 10 ways for outgoing SP MCB’s on iron/ G.I.
frame/wooden board as per specification No. SW-SWR/MCBDB
13970 Chapter 5-4-20 Supplying & erecting original 1.25 mm CRCA sheet metal 762.00 Each
8 enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug
top with 20A/30A single pole MCB complete erected on angle iron/
G.I. frame.
13970 Chapter 5-4-21 Supplying & erecting original 1.25 mm CRCA sheet metal 1,699.00 Each
9 enclosures with 30 A, 3 pin plug & earth socket and 30 A 3 pin
plug top with 30 A. triple pole MCB complete erected on angle
iron/ G.I. frame.
13971 Chapter 5-4-22 Supplying & erecting original 1.25 mm CRCA sheet metal 781.00 Each
0 enclosures with 10A. 2 pin plug and earth socket and 10A, 3 pin
plug top with 10A single pole miniature circuit breakers complete
erected on angle iron/ G.I. frame.
13971 Chapter 5-4-23 Supplying & erecting CRCA sheet metal one way enclosures 369.00 Each
1 suitable for D.P.M.C.B. /T.P. M.C.B. /F.P M.C.B. complete erected on
angle iron/ G.I. frame.
13971 Chapter 5-4-24 Supplying and erecting blanking plate of suitable size on MCB 12.00 Each
2 DB
13971 Chapter 5-4-25 Supplying & erecting triple pole and neutral distribution board 5,558.00 Each
3 (TPNDB) with door surface/ flush mounted suitable for 3 Pole
MCCB as Incommer & outgoing SP MCB (12 Poles) or TP MCB of 4
ways (12 Poles) on iron/ G.I. frame. (Vertical Busbar type) as per
specification no. SW-SWR/MCBDB1
Rate In (Rs)
Item Description Rate Unit
13971 Chapter 5-4-26 Supplying & erecting triple pole and neutral distribution board 6,598.00 Each
4 (TPNDB) with door surface/ flush mounted suitable for 3 Pole
MCCB as Incommer & outgoing SP MCB (24 Poles) or TP MCB of 8
ways (24 Poles) , on iron/ G.I. frame. (Vertical Busbar type) as
per specification No. SW-SWR/MCBDB1
13971 Chapter 5-4-27 Supplying & erecting triple pole and neutral distribution board 7,925.00 Each
5 (TPNDB) with door surface/ flush mounted suitable for 3 Pole
MCCB as Incommer & outgoing SP MCB (36 Poles) or TP MCB of
12 ways (36 Poles) on iron/ G.I. frame. (Vertical Busbar type) as
per specification No. SW-SWR/MCBDB1
Chapter 5-5 LT - MCCBs (SW-MCCB)
13971 Chapter 5-5-1 Providing & erecting 3 Pole MCCB upto 100A, 415V capacity with 4,119.00 Each
6 S.C. rating 25 kA (Ics=100% of Icu), thermal setting with
provided leads on iron /G.I. frame as per specification No.
SW-SWR/MCCB
13971 Chapter 5-5-2 Providing & erecting 3 Pole MCCB of 200A,415V capacity with S.C. 8,211.00 Each
7 rating 25 kA (Ics=100% of Icu) thermal and magnetic setting
with provided leads on iron /G.I. frame as per specification no.
SW-SWR/MCCB
13971 Chapter 5-5-3 Providing & erecting 3 Pole MCCB of 250A,415V capacity with S.C. 11,180.00 Each
8 rating 36 kA (Ics=100% of Icu),thermal and magnetic setting with
provided leads on iron /G.I.frame as per specification No.
SW-SWR/MCCB
13971 Chapter 5-5-4 Providing & erecting 3 Pole MCCB of 315/400A, 415V capacity with 14,814.00 Each
9 S.C. rating 36 kA (Ics=100% of Icu), thermal and magnetic setting
with provided leads on iron/G.I. frame as per specification No.
SW-SWR/MCCB
13972 Chapter 5-5-5 Providing & erecting 3 Pole MCCB of 600/630 A, 415V capacity 21,807.00 Each
0 with S.C. rating 36 kA (Ics=100% of Icu), thermal and magnetic
setting with provided leads on iron/G.I. frame as per specification
No. SW-SWR/MCCB
13972 Chapter 5-5-6 Providing & erecting 3 Pole MCCB of 800A, 415V capacity with 28,791.00 Each
1 S.C. rating 50 kA , thermal and magnetic setting with provided
leads on iron/G.I. frame as per specification No. SW-SWR/MCCB
Chapter 5-6 RCCB / RCBO(SW-RCCB)
13972 Chapter 5-6-1 Providing, erecting & commissioning RCCB only of electro 1,775.00 Each
2 magnetic type with 30/100/300 mA sensitivity and having
capacity of 16/ 25A. 2 pole complete as per specification No.
SW-RCCB/RCCB
Rate In (Rs)
Item Description Rate Unit
13972 Chapter 5-6-2 Providing, erecting & commissioning RCCB only of electro 1,876.00 Each
3 magnetic type with 30/100/300 mA sensitivity and having
capacity of 40A 2 pole complete as per specification No.
SW-RCCB/RCCB
13972 Chapter 5-6-3 Providing, erecting & commissioning RCCB only of electro 2,447.00 Each
4 magnetic type with 30/100/300 mA sensitivity and having
capacity of 63A 2 pole complete as per specification No.
SW-RCCB/RCCB
13972 Chapter 5-6-4 Providing, erecting & commissioning RCCB only of electro 2,341.00 Each
5 magnetic typewith 30/100/300 mA sensitivity and having capacity
of 16/25A 4 pole complete as per specification No.
SW-RCCB/RCCB
13972 Chapter 5-6-5 Providing, erecting & commissioning RCCB only of electro 2,372.00 Each
6 magnetic type with 30/100/300 mA sensitivity and having
capacity of 40A. 4 pole complete as per specification No.
SW-RCCB/RCCB
13972 Chapter 5-6-6 Providing, erecting & commissioning RCCB of electro magnetic 2,653.00 Each
7 type with 30/100/300 mA sensitivity and having capacity of 63A. 4
pole complete as per specification No. SW-RCCB/RCCB
13972 Chapter 5-6-7 Providing, erecting & commissioning RCCB of electro magnetic 4,243.00 Each
8 type with 30/100/300 mA sensitivity and having capacity of 80A. 4
pole complete as per specification No. SW-RCCB/RCCB
13972 Chapter 5-6-8 Providing, erecting & commissioning approved make RCCB of 4,207.00 Each
9 electro magnetic type with 30/100/300 mA sensitivity and having
capacity of 100A, 4 pole complete as per specification No.
SW-RCCB/RCCB
13973 Chapter 5-6-9 Supplying & fixing CRCA sheet Box with earthing terminals for 184.00 Each
0 housing 2 Pole RCCB complete on iron frame/laminated board.
13973 Chapter 5-6-10 Supplying & fixing CRCA sheet Box with earthing terminals for 232.00 Each
1 housing 4 Pole RCCB complete on iron frame/laminated board.
13973 Chapter 5-6-11 Supplying, fixing and commissioning RCBO (Residual Current 2,799.00 Each
2 Breaker with Overcurrent Protection), type AC with 30/100/300
mA sensitivity and having capacity of 6/10/16/20/25A, 2 Pole, 1
Phase as per specification SW-RCCB/RCBO
13973 Chapter 5-6-12 Supplying, fixing and commissioning RCBO (Residual Current 2,961.00 Each
3 Breaker with Overcurrent Protection), type AC with 30/100/300
mA sensitivity and having capacity of 32A/40A 2 Pole 1 phase as
per specification SW-RCCB/RCBO
Rate In (Rs)
Item Description Rate Unit
13973 Chapter 5-6-13 Supplying, fixing and commissioning RCBO (Residual Current 4,069.00 Each
4 Breaker with Overcurrent Protection), type AC with 30/100/300
mA sensitivity and having capacity of 63A, 2 Pole 1 Phase as per
specification SW-RCCB/RCBO
13973 Chapter 5-6-14 Supplying, fixing and commissioning RCBO (Residual Current 3,714.00 Each
5 Breaker with Overcurrent Protection), type ACwith 30/100/300
mA sensitivity and having capacity of 6A/10A/16A/20A/25/A 4 Pole
3 phase as per specification SW-RCCB/RCBO
13973 Chapter 5-6-15 Supplying, fixing and commissioning RCBO (Residual Current 3,844.00 Each
6 Breaker with Overcurrent Protection), type AC with 30/100/300
mA sensitivity and having capacity of 32A/40A 4 Pole 3 phase as
per specification SW-RCCB/RCBO
13973 Chapter 5-6-16 Supplying, fixing and commissioning RCBO (Residual Current 4,510.00 Each
7 Breaker with Overcurrent Protection), type AC with 30/100/300
mA sensitivity and having capacity of 63A 4 Pole 3 phase as per
specification SW-RCCB/RCBO
Chapter 5-7 MCCB Panel Boards and Accessories (SW- SWR-MCCBPB)
13973 Chapter 5-7-1 Providing & erecting Floor / Wall mounting, MCCB Panel board 32,451.00 Each
8 suitable for Four Pole Incoming 250A, 2 ways Four pole outgoing
on provided iron frame, as per Specification No SW-SWR/MCCBPB.
(Excluding MCCB'S)
13973 Chapter 5-7-2 Providing & erecting Floor / Wall mounting, MCCB Panel board 38,320.00 Each
9 suitable for Four Pole Incoming 250A, 4 ways Four pole outgoing
on provided iron frame, as per Specification No SW-SWR/MCCBPB.
(Excluding MCCB'S)
13974 Chapter 5-7-3 Providing & erecting Floor / Wall mounting, MCCB Panel board 43,772.00 Each
0 suitable for Four Pole Incoming 250A, 6 ways Four pole outgoing
on provided iron frame, as per Specification No SW-SWR/MCCBPB.
(Excluding MCCB'S)
13974 Chapter 5-7-4 Providing & erecting Floor / Wall mounting, MCCB Panel board 48,357.00 Each
1 suitable for Four Pole Incoming 250A, 8 ways Four pole outgoing
on provided iron frame, as per Specification No SW-SWR/MCCBPB.
(Excluding MCCB'S)
13974 Chapter 5-7-5 Providing & erecting Floor / Wall mounting, MCCB Panel board 59,358.00 Each
2 suitable for Four Pole Incoming 250A, 12 ways Four pole outgoing
erected on provided iron frame, as per Specification No
SW-SWR/MCCBPB. (Excluding MCCB'S)
13974 Chapter 5-7-6 Providing & erecting Floor / Wall mounting, MCCB Panel board 39,666.00 Each
3 suitable for Four Pole Incoming 400A, 2 ways Four pole outgoing
on provided iron frame, as per Specification No SW-SWR/MCCBPB.
Electrical - 2018-2019 (Excluding
- 01/04/2018 -
MCCB'S) Page 87 of 259 05/06/18 12:15
Chapter 5
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13975 Chapter 5-7-15 Providing & erecting Incoming and Outgoing Cable Alleys suitable 20,156.00 SET
2 for MCCB panel board of 250A incoming and 12 way outgoing or
400A incoming and 6/8 way outgoing made from CRCA sheet 1.6
mm thick duly powder coated and having vertical insulated
partition for shielding between the shared face of cableway and
basic DB.
13975 Chapter 5-7-16 Providing & erecting Incoming and Outgoing Cable Alleys suitable 23,518.00 SET
3 for MCCB panel board of 400A incoming and 12 way outgoing
made from CRCA sheet 1.6 mm thick duly powder coated and
having vertical insulated partition for shielding between the shared
face of cableway and basic DB.
13975 Chapter 5-7-17 Providing & erecting Prewired meter module suitable for MCCB 12,142.00 SET
4 panel board with CT's and emf's vif meter.
Chapter 5-8 LT - Air Circuit Breakers (SW-ACB)
13975 Chapter 5-8-1 Supplying and erecting Air circuit breaker manually operated 64,145.00 Each
5 non-drawout type of 630A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s),with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13975 Chapter 5-8-2 Supplying and erecting Air circuit breaker manually operated 66,651.00 Each
6 non-drawout type of 800A, 500V, 3 pole with having S.C. rating 50
kA (Ics=Icu=Icw for 1s), standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13975 Chapter 5-8-3 Supplying and erecting Air circuit breaker manually operated 70,612.00 Each
7 non-drawout type of 1000A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13975 Chapter 5-8-4 Supplying and erecting Air circuit breaker manually operated 99,916.00 Each
8 non-drawout type of 1600A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13975 Chapter 5-8-5 Supplying and erecting Air circuit breaker manually operated 1,10,711.00 Each
9 drawout type of 800A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13976 Chapter 5-8-6 Supplying and erecting Air circuit breaker manually operated 1,16,831.00 Each
0 drawout type of 1000A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
Rate In (Rs)
Item Description Rate Unit
13976 Chapter 5-8-7 Supplying and erecting Air circuit breaker manually operated 1,55,204.00 Each
1 drawout type of 1600A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s),with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13976 Chapter 5-8-8 Supplying and erecting Air circuit breaker manually operated 1,28,481.00 Each
2 drawout type of 1250 A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
13976 Chapter 5-8-9 Supplying and erecting Air circuit breaker manually operated 1,04,911.00 Each
3 Non drawout type of 1250A, 500V, 3 pole having S.C. rating 50 kA
(Ics=Icu=Icw for 1s), with standard acccessories on provided iron
frame as per specification No. SW-SWR/ACB
Chapter 5-9 HT SF6 Load Break Switch /VCB/RMU (SW-HTS)
13976 Chapter 5-9-1 Supplying and erecting approved make extendable / 1,28,782.00 Each
4 non-extendable Indoor type 11 kV, 630A, load break switch with
fuses of required rating, on provided MS channels / trench /
foundation in an approved manner as per specification no
SW-HTS / LBS
13976 Chapter 5-9-2 Supplying and erecting approved make extendable / 2,44,981.00 Each
5 non-extendable Indoor type 22 kV, 630A, load break switch with
fuses of required rating, on provided MS channels / trench /
foundation in an approved manner as per specification no
SW-HTS / LBS
13976 Chapter 5-9-3 Supplying and erecting approved make extendable / 1,34,253.00 Each
6 non-extendable Outdoor type 11 kV 630A, Load break Isolator
switch on provided MS channels / trench / foundation in an
approved manner as per specification no SW-HTS / LBS
13976 Chapter 5-9-4 Supplying and erecting approved make extendable / 2,49,283.00 Each
7 non-extendable Outdoor type 22 kV 630A, load break Isolator
switch on provided MS channels / trench / foundation in an
approved manner as per specification no SW-HTS / LBS
13976 Chapter 5-9-5 Supplying and erecting approved make 11 kV 400A, Oil 1,45,154.00 Each
8 Switch-Fuse unit extendable/non-extendable on provided MS
channels / trench / foundation in an approved manner as per
specification no SW-HTS / LBS
13976 Chapter 5-9-6 Supplying & erecting 11 kV 630A, Indoor type Ring Main unit with 3,22,857.00 Each
9 1or 2 Incoming & 2 or 1 Outgoing with HRC fuses complete
erected on provided cc foundation/MS channels/trench, etc, in an
approved manner as per specification no SW-HTS / RMU
Rate In (Rs)
Item Description Rate Unit
13977 Chapter 5-9-7 Supplying & erecting 22 kV 630A, Indoor type Ring Main unit with 5,51,733.00 Each
0 1or 2 Incoming & 2 or 1 Outgoing with HRC fuses complete
erected on provided c c foundation/MS channels/trench, etc, in an
approved manner as per specification no SW-HTS / RMU
13977 Chapter 5-9-8 Supplying and erecting approved make 11kV, 630A, Vacuum 5,08,879.00 Each
1 Circuit breaker of required rating, on provided MS channels /
trench / foundation in an approved manner as per specification no
SW-HTS / VCB
13977 Chapter 5-9-9 Supplying and erecting approved make 22 kV, 630 A, Vacuum 10,16,939. Each
2 Circuit breaker of required rating, on provided MS channels /
trench / foundation in an approved manner as per specification no
SW-HTS / VCB
13977 Chapter 5-9-10 Supplying and erecting 11kV HRC Fuse 10A to 40 A for load break 3,864.00 Each
3 switch to be fitted with necessary nut bolts and commissioning
complete.
13977 Chapter 5-9-11 Supplying and erecting 11 kV HRC Fuse 63A for load break switch 4,735.00 Each
4 to be fitted with necessary nut bolts and commissioning complete.
13977 Chapter 5-9-12 Supplying and erecting 22 kV HRC Fuse 10A to 40A for load break 8,127.00 Each
5 switch to be fitted with necessary nut bolts and commissioning
complete.
13977 Chapter 5-9-13 Supplying and erecting 22 kV HRC Fuse 63A for load break switch 9,233.00 Each
6 to be fitted with necessary nut bolts and commissioning complete.
13977 Chapter 5-9-14 Supplying , erecting, testing & commissioning 11kV, 630A, 2,59,405.00 Each
7 21kA/3sec, 1Way Outdoor, Extensible motorised SCADA compatible
RMU as per Electric Supply Co. specification consisting of 1No.
feeder with VCB. | <1VCB> as per specifiaation no. SW-HTS / RMU
SCADA
13977 Chapter 5-9-15 Supplying , erecting, testing & commissioning 11kV, 630A, 1,79,214.00 Each
8 21kA/3sec, 1Way Outdoor, Extensible motorised SCADA compatible
RMU as per Electric Supply Co. specification consisting of 1No.
feeder with 1LBS. | <1LBS> as per specifiaation no. SW-HTS /
RMU SCADA
13977 Chapter 5-9-16 Supplying , erecting, testing & commissioning 11kV, 630A, 3,88,994.00 Each
9 21kA/3sec, 2Way Outdoor, Extensible motorised SCADA compatible
RMU as per Electric Supply Co. specification consisting of 1No.
feeder with Load Break Switch and 1No. feeder with VCB. | <1LBS
+1VCB+M> as per specifiaation no. SW-HTS / RMU SCADA
13978 Chapter 5-9-17 Supplying , erecting, testing & commissioning 11kV, 630A, 4,73,836.00 Each
0 21kA/3sec, 3Way Outdoor, Extensible motorised SCADA compatible
RMU as per Electric Supply Co. specification consisting of 2Nos.
Electrical - 2018-2019 feeder
- 01/04/2018 Page
- Break Switch
with Load and91 of 259
1No. feeder with VCB. | <2LBS 05/06/18 12:15
Chapter 5 +1VCB+M> as per specifiaation no. SW-HTS / RMU SCADA
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13981 Chapter Supplying & erecting approved make 415V 63A porcelain base 103.00 Each
6 5-10-24 neutral link complete erected in provided M.S. box.
13981 Chapter Supplying & erecting approved make 415V 100A porcelain base 179.00 Each
7 5-10-25 neutral link complete erected in provided M.S. box.
13981 Chapter Supplying & erecting approved make porcelain/epoxy bus bar 55.00 Each
8 5-10-26 support complete erected in provided M.S. box for 100A
13981 Chapter Supplying & erecting approved make porcelain/epoxy bus bar 77.00 Each
9 5-10-27 support complete erected in provided M.S. box for 200/300A
13982 Chapter Supplying & erecting approved make porcelain/epoxy bus bar 95.00 Each
0 5-10-28 support complete erected in provided M.S. box for 400A
13982 Chapter Supplying & erecting approved make 415V 200A porcelain base 325.00 Each
1 5-10-29 neutral link complete erected in provided M.S. box.
Chapter 5-11 Accessories for MCCBs
13982 Chapter 5-11-1 Supplying and erecting terminal spreaders for use on MCCB 155.00 SET
2 incoming and outgoing terminals for 3 pole upto 100A MCCB.
13982 Chapter 5-11-2 Supplying and erecting terminal spreaders for use on MCCB 728.00 SET
3 incoming and outgoing terminals for 3 pole upto 250A MCCB.
13982 Chapter 5-11-3 Supplying and erecting terminal spreaders for use on MCCB 1,409.00 SET
4 incoming and outgoing terminals for 3 pole 300A- 400A MCCB.
13982 Chapter 5-11-4 Supplying and erecting terminal spreaders for use on MCCB 1,585.00 SET
5 incoming and outgoing terminals for 3 pole 630A MCCB.
13982 Chapter 5-11-5 Supplying and erecting terminal spreaders for use on MCCB 2,988.00 SET
6 incoming and outgoing terminals for 3 pole upto 800A MCCB.
13982 Chapter 5-11-6 Supplying and erecting terminal spreaders for use on MCCB 250.00 SET
7 incoming and outgoing terminals for 4 pole upto 100A MCCB.
13982 Chapter 5-11-7 Supplying and erecting terminal spreaders for use on MCCB 946.00 SET
8 incoming and outgoing terminals for 4 pole above 100A upto 250A
MCCB.
13982 Chapter 5-11-8 Supplying and erecting terminal spreaders for use on MCCB 2,020.00 SET
9 incoming and outgoing terminals for 4 pole above 250A upto 400A
MCCB.
13983 Chapter 5-11-9 Supplying and erecting terminal spreaders for use on MCCB 2,364.00 SET
0 incoming and outgoing terminals for 4 pole above 400A upto 630A
MCCB.
13983 Chapter Supplying and erecting terminal spreaders for use on MCCB 4,140.00 SET
1 5-11-10 incoming and outgoing terminals for 4 pole above 630A upto 800A
MCCB.
Electrical - 2018-2019 - 01/04/2018 - Page 95 of 259 05/06/18 12:15
Chapter 5
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
MCCB.
13983 Chapter Supplying and erecting earth fault module for MCCB with 4,446.00 Each
2 5-11-11 adjustable earth fault sensitivity selection 10% to 50% of nominal
current (In)and adjustable time delay 100/200 millisecond suitable
for upto 200A MCCB with inbuilt CT's.
13983 Chapter Supplying and erecting earth fault module for MCCB with 5,757.00 Each
3 5-11-12 adjustable earth fault sensitivity selection 10% to 50% of nominal
current (In) and adjustable time delay 100/200 millisecond
suitable for above 200A upto 400A MCCB with inbuilt CT's.
13983 Chapter Supplying and erecting earth fault module for MCCB with 4,283.00 Each
4 5-11-13 adjustable earth fault sensitivity selection 10% to 50% of nominal
current (In) and adjustable time delay 100/200 millisecond
suitable for above 400A upto 800A MCCB excluding CT's.
13983 Chapter Supplying and erecting extended rotary handle for MCCB with 1,013.00 Each
5 5-11-14 adjustable telescopic rod suitable for upto 250A MCCB.
13983 Chapter Supplying and erecting extended rotary handle for MCCB with 1,443.00 Each
6 5-11-15 adjustable telescopic rod suitable for above 250A upto 630A MCCB.
13983 Chapter Supplying and erecting extended rotary handle for MCCB with 2,384.00 Each
7 5-11-16 adjustable telescopic rod suitable above 630A upto 800A MCCB.
13983 Chapter Supplying and erecting SS enclosure for MCCB suitable for upto 761.00 Each
8 5-11-17 100A MCCB.
13983 Chapter Supplying and erecting SS enclosure for MCCB suitable for 125A to 1,258.00 Each
9 5-11-18 200A MCCB.
Chapter 5-12 Dismantling
13984 Chapter 5-12-1 Dismantling the existing switchgears, DB, and Bus bar of any size 76.00 Each
0 complete with/ without board or angle iron frame
13984 Chapter 5-12-2 Making the site clear of dismantled DB and switch gears by refilling 56.00 Each
1 the holes with cement mortar & finishing in an approved manner.
13984 Chapter 5-12-3 Dismantling existing OCB, ACB, LBS, VCB complete from existing 1,057.00 Each
2 panel board in an approved manner.
13984 Chapter 5-12-4 Dismantling any type of unservicable feeder pillar, Switch gear 1,057.00 Each
3 panel, Capacitor Panel, Metering panel, Bus-bar Panel, Electronic
Equipment Panel, etc. and remaking the site good as original.
Approx. size (upto 150 cm x 70 cm x 45 cm ) - Small Coupboard
13984 Chapter 5-12-5 Dismantling any type of unservicable feeder pillar, Switch gear 1,585.00 Each
4 panel, Capacitor Panel, Metering panel, Bus-bar Panel, Electronic
Equipment Panel, etc. and remaking the site good as original.
Approx. size ( upto 200cm. x 90 cm x 45 cm and above) - Big
Electrical - 2018-2019 Coupboard
- 01/04/2018 - Page 96 of 259 05/06/18 12:15
Chapter 5
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13985 Chapter 6-1-11 Supplying and erecting Plywood 6 mm thick fixed to wall or on 361.00 Sq.m
5 provided panel board with necessary materials such as screws,
wall fasteners supports, nuts bolts etc. complete.
13985 Chapter 6-1-12 Supplying and erecting Plywood 12 mm thick fixed to wall or on 605.00 Sq.m
6 provided panel board with necessary materials such as screws,
wall fasteners supports, nuts bolts etc. complete.
13985 Chapter 6-1-13 Supplying & pasting Sunmica/ Formica sheet 1 mm thick on 688.00 Sq.m
7 provided Plywood of required shade.
13985 Chapter 6-1-14 Supplying and erecting marine plywood 18/19 mm thick fixed to 1,157.00 Sq.m
8 wall or on provided panel board with necessary materials such as
screws, wall fasteners supports, nuts bolts etc. complete.
13985 Chapter 6-1-15 Supplying and erecting enamel iron G.I. sheet 1.6mm (16 gauge) 88.00 Each
9 caution board of size 200 x 150 mm. as per I.S. 2551 of 1982 in
Marathi and Hindi erected at position for medium installation.
13986 Chapter 6-1-16 Supplying and erecting enamel iron G.I. sheet 1.6mm (16 gauge) 174.00 Each
0 caution board of size 250 x 200 mm. as per I.S. 2551 of 1982 in
Marathi and Hindi erected at position for EHV installation.
13986 Chapter 6-1-17 Supplying and erecting G.I. sheet of 1.25mm (18gauge) size 200 70.00 Each
1 x 150 mm. duly painted with red oxide & enamel paint for
displaying the department & date of erection of the electrical
installation with approved shade as specified by the authority
13986 Chapter 6-1-18 Providing and erecting cupboard for enclosing switchgears or for 1,974.00 Sq.m
2 any other purpose made from selected marine plywood planks
19 mm thick duly varnished/ painted from inside and from outside
with brass hinges and locking arrangement with suitable lock with
duplicate keys. Cupboard duly grouted with suitable size of iron
work in wall at the bottom. (Size of cupboard shall be specified in
the estimate)
13986 Chapter 6-1-19 Supplying and erecting Iron, sheet metal work consisting of 119.00 kg
3 CRCA Sheets, Various sections of iron, Plates, Chequered
Plates, Rods, Bars, MS pipes, etc. for panel board or any other
purposes complete with bending, cutting, drilling and welding
complete erected at the position with necessary materials
duly painted with one coat of red oxide and two coats of
enamel paint to match the switchgears or as per directions by
the authority
13986 Chapter 6-1-20 Supplying and erecting self locking arrangement with 219.00 Each
4 duplicate keys, made of brass duly erected, flush with surface of
panel/cupboard.
Rate In (Rs)
Item Description Rate Unit
13986 Chapter 6-1-21 Supplying and erecting expanded metal jali enclosure made from 155.00 Sq.m
5 G.I. square mesh 15 SWG having 20/25 mm square, complete,
properly fixed/welded and duly painted with one coat of red oxide
and two coats of silver/enamel paint (size of jali or enclosure to
be specified in the estimate.)
13986 Chapter 6-1-22 Supplying and erecting slotted angles, frames etc. for panel 107.00 kg
6 board or any other purposes complete with bending, cutting,
drilling and welding complete erected at the position with
necessary materials duly painted with one coat of red oxide
and two coats of enamel paint to match the switchgears or
as per directions by the authority
Chapter 6-2 Bus bars (CP-BB)
13986 Chapter 6-2-1 Supplying and erecting Bus bar chamber triple pole with neutral 4,669.00 Meter
7 with four aluminium bars, 500V, 100A complete as per
specification no. CP-BB
13986 Chapter 6-2-2 Supplying and erecting Bus bar chamber triple pole with neutral 4,913.00 Meter
8 with four aluminium bars, 500V 200A complete as per
specification no. CP-BB
13986 Chapter 6-2-3 Supplying and erecting Bus bar chamber triple pole with neutral 5,220.00 Meter
9 with four aluminium bars, 500V 300A complete as per
specification no. CP-BB
13987 Chapter 6-2-4 Supplying and erecting Bus bar chamber triple pole with neutral 7,482.00 Meter
0 with four aluminium bars, 500V 400A complete as per
specification no. CP-BB
13987 Chapter 6-2-5 Supplying and erecting Bus bar chamber triple pole with 8,531.00 Meter
1 neutral with four aluminium bars, 500V 630A complete as per
specification no. CP-BB
13987 Chapter 6-2-6 Supplying and erecting Bus bar chamber triple pole with 9,379.00 Meter
2 neutral with four aluminium bars, 500V 800A complete as per
specification no. CP-BB
13987 Chapter 6-2-7 Supplying and erecting Bus bar chamber triple pole with neutral 6,675.00 Meter
3 with four Copper bars, 500V, 100A complete as per specification
no. CP-BB
13987 Chapter 6-2-8 Supplying and erecting Bus bar chamber triple pole with neutral 7,849.00 Meter
4 with four Copper bars, 500V 200A complete as per specification
no. CP-BB
13987 Chapter 6-2-9 Supplying & erecting of required size Electrolyte Copper Flexible 1,075.00 kg
5 Braided bus Patti or bar in bus bar chember/in panel or any other
purpose, suitable for 500 volt with require capacity with 99.9%
Electrical - 2018-2019 copper purity with
- 01/04/2018 - fixing arrangement
Page 100 of(like
259 lug or bottle type lug) 05/06/18 12:15
Chapter 6 to both the end with high grade polyolefin insulation sleeve
complete as per specification no. BCP-BB
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
copper purity with fixing arrangement (like lug or bottle type lug)
to both the end with high grade polyolefin insulation sleeve
complete as per specification no. BCP-BB
13987 Chapter 6-2-10 Supplying & erecting of any size Electrolyte Copper Patti or bar in 934.00 kg
6 bus bar chember / in panel or any other purpose, 500 volt with
require capacity with 99.9% copper purity with fixing arrangement
(like lug or bottle type lug) to both the end with high grade
polyolefin insulation sleeve complete as per specification no.
BCP-BB
13987 Chapter 6-2-11 Supplying & erecting of any size Electrolyte Alluminium Patti or bar 569.00 kg
7 in bus bar chember / in panel or any other purpose, 500 volt with
require capacity with 99.9% alluminium purity with fixing
arrangement (like lug or bottle type lug) to both the end with high
grade polyolefin insulation sleeve complete as per specification no.
BCP-BB
Chapter 6-3 Measuring Instruments
13987 Chapter 6-3-1 Supplying and erecting Static energy meter with 240V 50 2,019.00 Each
8 cycles A.C. supply 5-30 A, ISI mark, accuracy class 1.0 with
backlit LCD Display, (measuring & Display kWh, V,I,kW,, six month
history of energy & MD in kW ) with transparent Hinge Type box
complete erected on polished T.W. board duly wired with
required size of weather proof PVC wires duly tested by electric
supply company.
13987 Chapter 6-3-2 Supplying and erecting Static energy meter with 240V 50 2,152.00 Each
9 cycles A.C. supply 10-60 A, ISI mark, accuracy class 1.0 with
backlit LCD Display, (measuring & Display kWh, V,I,kW,, six month
history of energy & MD in kW ) with transparent Hinge Type box
complete erected on polished T.W. board duly wired with
required size of weather proof PVC wires duly tested by electric
supply company.
13988 Chapter 6-3-3 Supplying and erecting Static energy meter with 3X240V 50 4,349.00 Each
0 cycles A.C. supply 10-60 A, ISI mark, accuracy class 1.0 with
backlit LCD Display, (measuring & Display kWh ONLY ) with
transparent Hinge Type box complete erected on polished T.W.
board duly wired with required size of weather proof PVC wires
duly tested by electric supply company.
13988 Chapter 6-3-4 Supplying and erecting Static Energy meter 415-V 50 100A 5,129.00 Each
1 ISI mark meter with cycles A.C. 3 phase 4 wires LCD/LED
Display complete erected on polished T.W. board duly wired with
required size of weather proof PVC wires duly tested for class II
accuracy by electric supply company.
Rate In (Rs)
Item Description Rate Unit
13988 Chapter 6-3-5 Supplying and erecting LT/CT multifunction DLMS compliance 7,697.00 Each
2 energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical
& RS 232 port, backlit LCD, measures & Displays Trivector Energy,
load survey, TOD, tamper detection & logging, power ON /OFF
events, instaneous parameters of Rating -/5 Awith display in
absence of power complete with zero adjustment & test
certificate from manufacturer erected on provided M.S. box and
connected to CTs.
13988 Chapter 6-3-6 Supplying and erecting HT/CT multifunction DLMS compliance of 9,691.00 Each
3 accuracy of class 0.5 , 3x63.5V,50 Hz with optical & RS 232 port,
backlit LCD, measures kWh, kVAh, V,I,kW, 6 months history of
energy , load survey, & Displays Trivector Energy, load survey,
TOD, tamper detection & logging, power ON /OFF events,
instaneous parameters of Rating -/5 Awith display in absence of
power complete with zero adjustment & test certificate from
manufacturer erected on provided M.S. box.
13988 Chapter 6-3-7 Supplying and erecting panel mounting type digital ammeter 1,205.00 Each
4 having Three and half digit LED display, external C.T.
operated, calibrated for suitable to operate on 500V 0 to1000A
AC supply with necessary PVC wire leads and lugs and mounting
hardware on provided panel complete with calibration certificate
from manufacturer.
13988 Chapter 6-3-8 Supplying and erecting panel mounting type digital voltmeter 1,205.00 Each
5 having Three and half digit LED display, calibrated for 0 to
750V AC suitable to operate on 500V AC supply with necessary
PVC wire leads and lugs and mounting hardware on provided
panel complete with calibration certificate from manufacturer.
13988 Chapter 6-3-9 Supplying and erecting Intelligent flush mounted panel meter 6,003.00 Each
6 three phase four wire (IPM) input voltage measurement range
50-550 VAC (P-P) 415V,Aux supply 90-300 VAC/DC, CT secondary
site selectable 1A / 5A, Flush mounting 96 x 96 mm , CT/ PT site
programmable, Flush mounted (96 x 96 mm) meter Constant Wh
viewing in LCD Multifunction meters in auto scroll mode with
Voltage, current, frequency, Power factor kW,kVA, kVAR, KWh,
kVAh, kVARh, phase angle, interrupts, THD, Events (high- low)
neutral current with LED Display (excluding CT'S) complete with
RS 485 communication protocol, class 1 accuracy and wriring
connections and mounting hardware on provided panels
complete with calibration certificate from manufacture
13988 Chapter 6-3-10 Supplying and erecting Dual Source Intelligent flush mounted 3,485.00 Each
7 panel meter three phase four wire (IPM) 415V CT/ PT site
programmable class1 Flush mounted (96 x 96 mm) meter with
Voltage, current, frequency, Power factor , ON hours ,kWh, EB
Electrical - 2018-2019 - 01/04/2018 - Page 102 of 259 05/06/18 12:15
and DG set metering with LED Display (excluding CT'S) complete
Chapter 6
with RS 485 communication protocol, class 1 accuracy and wriring
connections and mounting hardware on provided panels
complete with calibration certificate from manufacture
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
13995 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 70 445.00 Meter
9 -1-25 sq mm aluminium conductor with continuous 8.35 sq mm (10
SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 95 549.00 Meter
0 -1-26 sq mm aluminium conductor with continuous 8.35 sq mm (10
SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe asper
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3½ core 618.00 Meter
1 -1-27 120 sq mm aluminium conductor with continuous 12.97 sq mm
(8 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3½ core 740.00 Meter
2 -1-28 150 sq mm aluminium conductor with continuous 12.97 sq mm
(8 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 1100 V. 904.00 Meter
3 -1-29 3½ core 185 sq mm aluminium conductor with continuous 12.97
sq mm (8 SWG) G.I. earth wire complete erected with glands &
lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3½core 1,133.00 Meter
4 -1-30 240 sq mm aluminium conductor with continuous 12.97 sq mm
(8 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3½ core 1,280.00 Meter
5 -1-31 300 sq mm aluminium conductor with continuous 12.97 sq mm
(8 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
13996 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3½core 1,597.00 Meter
6 -1-32 400 sq mm aluminium conductor with continuous 12.97 sq mm
(8 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
no. CB-LT/CU
13997 Chapter 7 Supplying, erecting & terminating PVC armoured cable 2 core 4 161.00 Meter
6 -2-2 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13997 Chapter 7 Supplying, erecting & terminating PVC armoured cable 2 core 6 206.00 Meter
7 -2-3 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13997 Chapter 7 Supplying, erecting & terminating PVC armoured cable 2 core 10 294.00 Meter
8 -2-4 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13997 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3 core 156.00 Meter
9 -2-5 2.5 sq mm copper conductor continuous 5.48 sq mm (12 SWG)
G.I. earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3 core 4 199.00 Meter
0 -2-6 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3 core 6 263.00 Meter
1 -2-7 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 3 core 10 387.00 Meter
2 -2-8 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 4 245.00 Meter
3 -2-9 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
Electrical - 2018-2019 - 01/04/2018 - Page 117 of 259 05/06/18 12:15
Chapter 7
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 6 330.00 Meter
4 -2-10 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 10 490.00 Meter
5 -2-11 sq mm copper conductor continuous 5.48 sq mm (12 SWG) G.I.
earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 16 698.00 Meter
6 -2-12 sq mm copper conductor with continuous 5.48 sq mm (12 SWG)
G.I. earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 25 1,129.00 Meter
7 -2-13 sq mm copper conductor with continuous 5.48 sq mm (12 SWG)
G.I. earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 35 1,542.00 Meter
8 -2-14 sq mm copper conductor with continuous 5.48 sq mm (12 SWG)
G.I. earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13998 Chapter 7 Supplying, erecting & terminating PVC armoured cable 4 core 50 2,101.00 Meter
9 -2-15 sq mm copper conductor with continuous 5.48 sq mm (12 SWG)
G.I. earth wire complete erected with glands & lugs, on wall/
trusses/pole or laid in provided trench/ pipe as per specification
no. CB-LT/CU
13999 Chapter 7 Supplying, erecting & terminating PVC Unarmoured cable 1 core 325.00 Meter
0 -2-16 25 sq. mm copper conductor complete erected with provided lugs,
laid in provided control panel /distribution boards / pipe as per
specification no. CB-LT/CU
13999 Chapter 7 Supplying, erecting & terminating PVC Unarmoured cable 1 core 437.00 Meter
1 -2-17 35 sq. mm copper conductor complete erected with provided lugs,
laid in provided control panel /distribution boards / pipe as per
specification no. CB-LT/CU
13999 Chapter 7 Supplying, erecting & terminating PVC Unarmoured cable 1 core 582.00 Meter
2 -2-18 50 sq. mm copper conductor complete erected with provided lugs,
laid in provided control panel /distribution boards / pipe as per
Electrical - 2018-2019 specification
- 01/04/2018 - CB-LT/CU Page 118 of 259
no. 05/06/18 12:15
Chapter 7
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14000 Chapter 7 Supplying , erecting & terminating 3 x 150 sq mm 11 kV, XLPE(E) 1,442.00 Meter
4 -3-10 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14000 Chapter 7 Supplying , erecting & terminating 3 x 185 sq.mm 11 kV, XLPE(E) 1,682.00 Meter
5 -3-11 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14000 Chapter 7 Supplying , erecting & terminating 3 x 240 sq mm 11 kV, XLPE(E) 1,999.00 Meter
6 -3-12 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14000 Chapter 7 Supplying , erecting & terminating 3 x 300 sq mm 11 kV, XLPE(E) 2,303.00 Meter
7 -3-13 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14000 Chapter 7 Supplying , erecting & terminating 3 x 400 sq mm 11 kV, XLPE(E) 2,692.00 Meter
8 -3-14 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14000 Chapter 7 Supplying , erecting & terminating 3 x 150 sq mm 22 kV, XLPE(E) 1,565.00 Meter
9 -3-15 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 185 sq mm 22 kV, XLPE(E) 1,747.00 Meter
0 -3-16 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 240 sq mm 22 kV, XLPE(E) 2,035.00 Meter
1 -3-17 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 300 sq mm 22 kV, XLPE(E) 2,338.00 Meter
2 -3-18 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 150 sq mm 33 kV, XLPE(E) 1,984.00 Meter
3 -3-19 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 185 sq mm 33 kV, XLPE(E) 2,184.00 Meter
4 -3-20 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 240 sq mm 33 kV, XLPE(E) 2,488.00 Meter
5 -3-21 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
14001 Chapter 7 Supplying , erecting & terminating 3 x 300 sq mm 33 kV, XLPE(E) 2,800.00 Meter
6 -3-22 armoured cable on wall/ceiling or laid in provided trench / pipe in
an approved manner as per specification No. CB-HT
Electrical - 2018-2019 - 01/04/2018 - Page 120 of 259 05/06/18 12:15
Chapter 7
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14002 Chapter 7 Providing & erecting epoxy outdoor / indoor end termination kit 2,807.00 Each
9 -4-13 for LT PVC armoured cable 400 sq mm. cable, with necessary
material as per specification No. CB-JT/LT
Chapter 7 -5 Cable Joints & End Termination Kits (HT Cables) (CB-JT/HT)
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 14,781.00 Each
0 -5-1 33 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 10,708.00 Each
1 -5-2 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 13,741.00 Each
2 -5-3 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 20,266.00 Each
3 -5-4 33 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 15,888.00 Each
4 -5-5 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 24,766.00 Each
5 -5-6 33 kV ( E ) XLPE HT cable 3x240 to 400 sq mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable out door termination kit for 18,341.00 Each
6 -5-7 22 kV ( E ) XLPE HT cable 3x70 to 120 sq mm cable with
necessary material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable out door termination kit for 22,358.00 Each
7 -5-8 33 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary
material as per specification No. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 14,057.00 Each
8 -5-9 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary
material as per specification no. CB-JT/HT
14003 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 20,169.00 Each
9 -5-10 22 kV ( E ) XLPE HT cable 3x150 to 185 sq. mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 28,333.00 Each
0 -5-11 33 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary
material as per specification No. CB-JT/HT
Rate In (Rs)
Item Description Rate Unit
14004 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 27,004.00 Each
1 -5-12 22 kV ( E ) XLPE HT cable 3x240 to 400 sq mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 36,803.00 Each
2 -5-13 33 kV ( E ) XLPE HT cable 3x240 to 400 sq mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable Straight through joint kit 29,710.00 Each
3 -5-14 for 11 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with
necessary material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable Straight through joint kit 56,335.00 Each
4 -5-15 for 22 kV ( E ) XLPE HT cable 3x300 to 400 sq. mm with
necessary material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable Straight through joint kit 83,641.00 Each
5 -5-16 for 33 kV ( E ) XLPE HT cable 3x300 to 400 sq mm with
necessary material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 8,927.00 Each
6 -5-17 11 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 10,986.00 Each
7 -5-18 22 kV ( E ) XLPE HT cable 3x70 to 95 sq. mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 11,270.00 Each
8 -5-19 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary
material as per specification No. CB-JT/HT
14004 Chapter 7 Providing and erecting Heat shrinkable indoor termination kit for 11,898.00 Each
9 -5-20 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material
as per specification No. CB-JT/HT
14005 Chapter 7 Providing and erecting Heat shrinkable out door termination kit for 13,181.00 Each
0 -5-21 11 kV ( E ) XLPE HT cable 3x70 to 95 sq mm with necessary
material as per specification No. CB-JT/HT
14005 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 15,643.00 Each
1 -5-22 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary
material as per specification No. CB-JT/HT
14005 Chapter 7 Providing and erecting Heat shrinkable outdoor termination kit for 16,389.00 Each
2 -5-23 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material
as per specification No. CB-JT/HT
14005 Chapter 7 Providing and erecting Heat shrinkable Straight through joint kit 20,836.00 Each
3 -5-24 for 11 kV ( E ) XLPE HT cable 3x70 to 95 sq.mm. with necessary
material as per specification No. CBJT/HT
Electrical - 2018-2019 - 01/04/2018 - Page 123 of 259 05/06/18 12:15
Chapter 7
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
cable & necessary back filling with light ramming to make the
road/ground surface as it was (Except bitumen carpet).
14006 Chapter 7 Supplying & laying (including excavation) 15 cm dia half round 432.00 Meter
6 -6-6 RCC Hume pipe of standard thickness at required depth up to
90 cms. below road / ground surface, for enclosing provided
cable & necessary back filling with light ramming to make the
road/ground surface as it was (Except bitumen carpet).
14006 Chapter 7 Supplying & laying (including excavation) 25 cm dia RCC Hume 601.00 Meter
7 -6-7 pipe of standard thickness at required depth up to 90 cms. below
road / ground surface, for covering provided cable &
necessary back filling with light ramming to make the
road/ground surface as it was (Except bitumen carpet).
14006 Chapter 7 Supplying & laying (including excavation) 25 cm Dia half round 470.00 Meter
8 -6-8 RCC Hume pipe of standard thickness at required depth up to 90
cms. below road / ground surface, for enclosing provided cable
& necessary back filling with light ramming to make the
road/ground surface as it was (Except bitumen carpet).
14006 Chapter 7 Supplying and laying (including excavation) 50 mm outside 185.00 Meter
9 -6-9 dia. double wall corrugated pipes (DWC) of HDPE for enclosing
cable below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 77 mm outside dia. 207.00 Meter
0 -6-10 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 90 mm outside 278.00 Meter
1 -6-11 dia. double wall corrugated pipes (DWC) of HDPE for enclosing
cable below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 120 mm outside dia. 313.00 Meter
2 -6-12 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 146 mm outside dia. 369.00 Meter
3 -6-13 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 160 mm outside dia, 391.00 Meter
4 -6-14 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
14007 Chapter 7 Supplying and laying (including excavation) 175 mm outside dia, 493.00 Meter
5 -6-15 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
Rate In (Rs)
Item Description Rate Unit
14007 Chapter 7 Supplying and laying (including excavation) 200 mm outside dia, 560.00 Meter
6 -6-16 double wall corrugated pipes (DWC) of HDPE for enclosing cable
below ground/road surface, to required depth complete.
Chapter 7 -7 Cable Glands(CB-GL)
14007 Chapter 7 Supplying & erecting Siemens type brass cable glands for 2 to 4 35.00 Each
7 -7-1 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for PVC
armoured cable as per specification No. CB-GL
14007 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3 to 4 40.00 Each
8 -7-2 core 6 sq mm /2 to 4 core 10 sq mm for PVC armoured cable as
per specification No. CB-GL
14007 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3 to 4 50.00 Each
9 -7-3 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for PVC
armoured cable as per specification No. CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 4 core 62.00 Each
0 -7-4 35 Sq.mm./3 core 50 Sq.mm. for PVC armoured cable as per
specification no. CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 4 core 79.00 Each
1 -7-5 50 sq mm for PVC armoured cable as per specification No. CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½ 90.00 Each
2 -7-6 core 70 sq mm for PVC armoured cable as per specification No.
CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½ 103.00 Each
3 -7-7 core 95 sq mm for PVC armoured cable as per specification No.
CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½ 118.00 Each
4 -7-8 core 120 sq mm for PVC armoured cable as per specification No.
CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½ 140.00 Each
5 -7-9 core 150 sq mm for PVC armoured cablen as per specification No.
CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½ 178.00 Each
6 -7-10 core 185 sq mm for PVC armoured cable as per specification No.
CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½core 203.00 Each
7 -7-11 240 sq mm for PVC armoured cable as per specification No. CB-GL
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½core 239.00 Each
8 -7-12 300 sq mm for PVC armoured cable as per specification No.
CB-GL
Electrical - 2018-2019 - 01/04/2018 - Page 126 of 259 05/06/18 12:15
Chapter 7
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14008 Chapter 7 Supplying & erecting Siemens type brass cable glands for 3½core 275.00 Each
9 -7-13 400 sq mm for PVC armoured cable as per specification No. CB-GL
Chapter 7 -8 Street Light Boxes & Cable Indicators (CB-SB/CB-CIP)
14009 Chapter 7 Supplying & erecting cast iron cable indicator plate buried along 171.00 Each
0 -8-1 with route of cable for PVC / XLPE armoured cable as per
specification No. CB-CIP
14009 Chapter 7 Supplying & erecting water tight terminal box of 1.6 mm (16 440.00 Each
1 -8-2 gauge) CRCA sheet of size 200 x 150 x 150 mm. complete on pole
as per specification No. CB-SB
14009 Chapter 7 Supplying & erecting water tight terminal box of 1.6 mm (16 622.00 Each
2 -8-3 gauge) CRCA sheet of size 300 x 200 x 150 mm complete on pole
as per specification No. CB-SB
14009 Chapter 7 Supplying & erecting water tight terminal box of 1.6 mm (16 290.00 Each
3 -8-4 gauge) CRCA sheet of size 150 x 100 x 100 mm complete on pole
as per specification No. CB-SB
14009 Chapter 7 Supplying & erecting water tight terminal box of cast iron of size 548.00 Each
4 -8-5 200 x 150 x 150 mm complete on pole as per specification No.
CB-SB
14009 Chapter 7 Supplying & erecting water tight terminal box of cast iron of size 648.00 Each
5 -8-6 300 x 200 x 150 mm complete on pole as per specification No.
CB-SB
14009 Chapter 7 Supplying & erecting water tight terminal box of cast iron of size 467.00 Each
6 -8-7 150 x 100 x 100 mm complete on pole as per specification No.
CB-SB
14009 Chapter 7 Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 546.00 Each
7 -8-8 2.7 mm thick complete on pole/wall as per specification No.
CB-SB
14009 Chapter 7 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 501.00 Each
8 -8-9 2.7 mm thick complete on pole/wall as per specification No.
CB-SB
14009 Chapter 7 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 420.00 Each
9 -8-10 2.7 mm thick complete on pole/wall as per specification No.
CB-SB
Chapter 7 -9 Cable Lugs (Copper) (CB-CL/CU)
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable upto 16 15.00 Each
0 -9-1 sq mm complete as per specification No. CB-CL/CU
Rate In (Rs)
Item Description Rate Unit
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 25 sq 20.00 Each
1 -9-2 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 35 sq 24.00 Each
2 -9-3 mm complete asper specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 50 sq 28.00 Each
3 -9-4 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 70 sq 39.00 Each
4 -9-5 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 95 sq 51.00 Each
5 -9-6 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 120 sq 70.00 Each
6 -9-7 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 150 sq 90.00 Each
7 -9-8 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 185 sq 125.00 Each
8 -9-9 mm complete as per specification No. CB-CL/CU
14010 Chapter 7 Supplying & erecting crimping type copper lugs for cable 240 sq 176.00 Each
9 -9-10 mm complete as per specification No. CB-CL/CU
14011 Chapter 7 Supplying & erecting crimping type copper lugs for cable 300 sq 238.00 Each
0 -9-11 mm complete as per specification No. CB-CL/CU
14011 Chapter 7 Supplying & erecting crimping type copper lugs for cable 400 sq 351.00 Each
1 -9-12 mm complete as per specification No. CB-CL/CU
Chapter 7 -10 Cable Lugs (Aluminium) (CB-CL/AL)
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable upto 6.00 Each
2 -10-1 16 sq mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 25 sq 6.00 Each
3 -10-2 mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 35 sq 12.00 Each
4 -10-3 mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 50 sq 13.00 Each
5 -10-4 mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 70 sq 17.00 Each
6 -10-5 mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 95 sq 17.00 Each
7 -10-6 mm complete as per specification No. CB-CL/AL
Rate In (Rs)
Item Description Rate Unit
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 120 24.00 Each
8 -10-7 sq mm complete as per specification No. CB-CL/AL
14011 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 150 31.00 Each
9 -10-8 sq mm complete as per specification No. CB-CL/AL
14012 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 185 41.00 Each
0 -10-9 sq mm complete as per specification No. CB-CL/AL
14012 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 240 56.00 Each
1 -10-10 sq mm complete as per specification No. CB-CL/AL
14012 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 300 84.00 Each
2 -10-11 sq mm complete as per specification No. CB-CL/AL
14012 Chapter 7 Supplying & erecting crimping type aluminium lugs for cable 400 107.00 Each
3 -10-12 sq mm complete as per specification No. CB-CL/AL
Chapter 7 -11 Cable Tray (CB-CT)
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Ladder type Cable tray 640.00 Meter
4 -11-1 manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm
width & 100 mm height comprising all required standard
accessories.
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Ladder type Cable tray 661.00 Meter
5 -11-2 manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm
width & 100 mm height comprising all required standard
accessories.
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Ladder type Cable tray 693.00 Meter
6 -11-3 manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm
width & 100 mm height comprising all required standard
accessories.
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Ladder type Cable tray 726.00 Meter
7 -11-4 manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm
width & 100 mm height comprising all required standard
accessories.
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Ladder type Cable tray 759.00 Meter
8 -11-5 manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm
width & 100 mm height comprising all required standard
accessories.
14012 Chapter 7 Providing & erecting Hot dipped Galvanised Perforated type Cable 430.00 Meter
9 -11-6 tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150
mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner.
Rate In (Rs)
Item Description Rate Unit
14013 Chapter 7 Providing & erecting Hot dipped Galvanised Perforated type Cable 488.00 Meter
0 -11-7 tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200
mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised Perforated type Cable 604.00 Meter
1 -11-8 tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300
mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised Perforated type Cable 721.00 Meter
2 -11-9 tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400
mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised Perforated type Cable 837.00 Meter
3 -11-10 tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500
mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised cover suitable for 198.00 Meter
4 -11-11 perforated type Cable tray manufactured from 18 swg (1.2 mm
thick) GI sheet of 150 mm width & 20 mm height complete with
necessary hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised cover suitable for 242.00 Meter
5 -11-12 perforated type Cable tray manufactured from 18 swg (1.2 mm
thick) GI sheet of 200 mm width & 20 mm height complete with
necessary hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised cover suitable for 330.00 Meter
6 -11-13 perforated type Cable tray manufactured from 18 swg (1.2 mm
thick) GI sheet of 300 mm width & 20 mm height complete with
necessary hardware in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised cover suitable for 419.00 Meter
7 -11-14 perforated type Cable tray manufactured from 18 swg (1.2 mm
thick) GI sheet of 400 mm width & 20 mm height complete with
necessary hardwere in approved manner.
14013 Chapter 7 Providing & erecting Hot dipped Galvanised cover suitable for 506.00 Meter
8 -11-15 perforated type Cable tray manufactured from 18 swg (1.2 mm
thick) GI sheet of 500 mm width & 20 mm height complete with
necessary hardware in approved manner.
Chapter 7 -12 Dismantling
14013 Chapter 7 Dismantling the existing cables of all types & size upto 10 sq 12.00 Meter
9 -12-1 mm.
Rate In (Rs)
Item Description Rate Unit
14014 Chapter 7 Dismantling the existing cables of all types & size above 10 sq 18.00 Meter
0 -12-2 mm upto 50 sq.mm.
14014 Chapter 7 Dismantling the existing cables of all types & size above 50 sq 24.00 Meter
1 -12-3 mm.
14014 Chapter 7 Refilling the holes for dismantled cables with cement mortar & 45.00 Meter
2 -12-4 finishing in an aproved manner etc. complete
14014 Chapter 7 Dismantling the existing underground cable without damaging it 74.00 Meter
3 -12-5 with glands, cable end box including refilling the trench up to
ground level and making coils complete.
Specification:
Rate In (Rs)
Item Description Rate Unit
14015 Chapter 8-1-9 Supplying and erecting Rolled steel Joist (Girder) pole 175 x 1,080.00 Meter
2 85 mm (19.6 kg/m) with provided base plate in provided
foundation as per specification No. OH-PL/RSJ
14015 Chapter 8-1-10 Supplying and erecting Rolled steel Joist (Girder) pole 100 x 1,246.00 Meter
3 116 mm (23 kg/m) with provided base plate in provided
foundation as per specification No. OH-PL/RSJ
14015 Chapter 8-1-11 Supplying and erecting Rolled steel Joist (Girder) pole 125 x 790.00 Meter
4 70 mm (13.3 kg/m) with provided base plate in provided
foundation as per specification No. OH-PL/RSJ
14015 Chapter 8-1-12 Supplying and erecting Rolled steel Joist (Girder) pole 152 x 1,903.00 Meter
5 152 mm (37.1 kg/m) with provided base plate in provided
foundation as per specification No. OH-PL/RSJ
14015 Chapter 8-1-13 Supplying and erecting Rail pole (29.76 kg/m) with provided 1,537.00 Meter
6 base plate in provided foundation as per specification No.
OH-PL/RLP
14015 Chapter 8-1-14 Supplying and erecting ISI mark G.I. pipe pole ‘B’ grade 80 4,356.00 Each
7 mm dia 6 m long with pole cap, base plate in provided foundation
as per specification No. OH-PL/GIP
14015 Chapter 8-1-15 Supplying and erecting M.S. pipe pole ‘B’ grade 80 mm dia 6 m 4,363.00 Each
8 long with pole cap, base plate in provided foundation as per
specification No. OH-PL/GIP
14015 Chapter 8-1-16 Supplying and erecting steel tubular swaged type welded pole 14,772.00 Each
9 with upper portion hydraulically bent swan neck, 165.1 x 139.7 x
114.3 mm dia with 4.5 x 4.50 x 3.65 mm thickness (5 + 2 + 3 m)
respectively (net vertical height 9 m.) total length 10 m long with
base plate in provided foundation.(weight 156.75 kg) as per
specification No. OH-PL/STP
14016 Chapter 8-1-17 Supplying and erecting steel tubular swaged type welded pole 15,114.00 Each
0 with upper portion bent swan neck, 165.1 x 139.7 x 114.3 mm
dia. with 4.5 x 4.5 x 3.65 mm thickness (5.6 + 2.7 + 2.7 m)
respectively total 11 m long with base plate in provided
foundation.(weight 175 kg) as per specification No.OH-PL/STP
Chapter 8-2 PSC Poles(OH-PSC)
14016 Chapter 8-2-1 Supplying and erecting PSC rectangular pole of top 90 x 102 / 2,669.00 Each
1 105 mm & bottom of 90 x 275 mm 8 m long (140 kg) complete
erected in provided C. C. foundation & muffing (square/round) as
per specification No. OH-PL/PSC
14016 Chapter 8-2-2 Supplying and erecting PSC rectangular pole of top 105 x 115 3,256.00 Each
2 mm & bottom of 105 x 315 mm 9 m long (200 kg) complete
Electrical - 2018-2019 erected in provided
- 01/04/2018 - C. C. foundation
Page 133 &
of muffing
259 (square/round) as 05/06/18 12:15
Chapter 8 per specification No. OH-PL/PSC
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14017 Chapter Providing & erecting 8 m high (clear height) galvanised 16,147.00 Each
7 8-3-10-6 OCTAGONAL pole with foundation bolts having bottom of 135 mm
A/F, top 70 mm A/F on provided foundation as per specification
No.OH-PL/OPL
14017 Chapter Providing & erecting 9 m high (clear height) galvanised 18,170.00 Each
8 8-3-10-7 OCTAGONAL pole with foundation bolts having bottom of 155 mm
A/F, top 70 mm A/F on provided foundation as per specification
No.OH-PL/OPL
14017 Chapter Providing & erecting 10 m high (clear height) galvanised 20,553.00 Each
9 8-3-10-8 OCTAGONAL pole with foundation bolts having bottom of 175 mm
A/F, top 70 mm A/F on provided foundation as per specification
No.OH-PL/OPL
14018 Chapter Providing & erecting 11 m high (clear height) galvanised 25,137.00 Each
0 8-3-10-9 OCTAGONAL pole with foundation bolts having bottom of 210 mm
A/F, top 90 mm A/F on provided foundation as per specification
No.OH-PL/OPL
14018 Chapter Providing & erecting 12 m high (clear height) galvanised 28,846.00 Each
1 8-3-10-10 OCTAGONAL pole with foundation bolts having bottom of 240 mm
A/F, top 90 mm A/F on provided foundation as per specification No.
OH-PL/OPL
Chapter 8-3-11 Hot Dipped Galvanized CONICAL Poles
14018 Chapter Providing & erecting 3 m high galvanised CONICAL pole with 10,519.00 Each
2 8-3-11-1 foundation bolts having bottom dia. from 105 to 115 mm, top dia.
from 65 to 75 mm on provided foundation as per specification No.
OH-PL/CPL
14018 Chapter Providing & erecting 4 m high galvanised CONICAL pole with 12,162.00 Each
3 8-3-11-2 foundation bolts having bottom dia. from 115 to 130 mm, top dia.
from 65 to 75 mm on provided foundation as per specification No.
OH-PL/CPL
14018 Chapter Providing & erecting 5 m high galvanised CONICAL pole with 13,252.00 Each
4 8-3-11-3 foundation bolts having bottom dia. from 125 to 145 mm, top dia.
from 65 to 75 mm on provided foundation as per specification No.
OH-PL/CPL
14018 Chapter Providing & erecting 6 m high galvanised CONICAL pole with 14,814.00 Each
5 8-3-11-4 foundation bolts having bottom dia. from 135 to 160 mm, top dia.
from 65 to 75 mm on provided foundation as per specification No.
OH-PL/CPL.
14018 Chapter Providing & erecting 7 m high galvanised CONICAL pole with 16,856.00 Each
6 8-3-11-5 foundation bolts having bottom dia. 145 to 175 mm, top dia. 65 to
75 mm on provided foundation as per specification No. OH-PL/CPL
Electrical - 2018-2019 - 01/04/2018 - Page 136 of 259 05/06/18 12:15
Chapter 8
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14020 Chapter 8-4-9 Supplying pole bracket,for OH conductor fabricated from ISMC 477.00 Each
4 channel, 75x40x6.8 mm, 550 mm long for two insulators and
welded with extension channel pieces of same size 300 mm in
length and erecting on pole with 50x6 mm clamp as per approved
method of construction and complete as per specification No.
OH-PL/BKT
14020 Chapter 8-4-10 Supplying pole bracket, fabricated from ISMC channel, 75x40x6.8 665.00 Each
5 mm, 1100 mm long for 4 insulators and welded with extension
channel pieces of same size 300 mm. in length and erecting on
pole with 50x6 mm clamp as per approved method of construction
and complete as per specification No. OH-PL/BKT
14020 Chapter 8-4-11 Supplying 100 x 50 mm with 4.7 mm thick web and 7.5 mm thick 1,751.00 Each
6 flange channel iron cross arm of suitable length for 2.4m wide DP
structure and erecting on DP with 50x6 mm clamp as per approved
method of construction and complete as per specification No.
OH-PL/BKT.
14020 Chapter 8-4-12 Supplying and erecting Vee cross arm for 11kV HTOH line with 1,609.00 Each
7 arrangement to fix insulator at 45mm from the end & horizontal
distance between insulators 1220 mm bent at angle of 60 degree
keeping base 305 mm and the total vertical height of V cross arm
as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut
bolts,washers complete as per specification No. OH-PL/VCA
14020 Chapter 8-4-13 Supplying and erecting Vee cross arm for 22/ 33kV HTOH line with 2,171.00 Each
8 arrangement to fix insulator at 45mm from the end & horizontal
distance between insulators 1530 mm bent at angle of 60 degree
keeping base 310 mm and the total vertical height of V cross arm
as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut
bolts,washers complete as per specification No. OH-PL/VCA
14020 Chapter 8-4-14 Supplying and erecting 75x40 mm with 4.4 mm thick web and 7.3 451.00 Each
9 mm thick flange channel (top pin) with clamp of suitable length
so as to maintain vertical clearance of 1065 mm for 11 kV,1320
mm for 22 kV between insulators for erection of top pin insulators
complete as per specification No. OH-PL/VCA
14021 Chapter 8-4-15 Supplying and erecting bracket for guarding, made from 890.00 Each
0 channel iron 1600 mm in length and 75x40 mm. with 4.4 mm.
thick web and 7.3 mm thick flange erected on pole complete as
per specification no. OH-PL/VCA
14021 Chapter 8-4-16 Supplying and erecting bracket for guarding, made from 806.00 Each
1 channel iron 1600 mm in length and 65 x 65 x 6mm thick web
and 7.3 mm thick flange erected on pole as per specification no.
OH-PL/VCA
Electrical - 2018-2019 - 01/04/2018 - Page 139 of 259 05/06/18 12:15
Chapter 8
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
OH-CON/ACSR
14023 Chapter 8-5-10 Supplying and erecting ACSR conductor of size - 6/1-4.09 mm 61,993.00 KM
1 (Raccon) complete. (318.00 kg/km) as per specification No.
OH-CON/ACSR
14023 Chapter 8-5-11 Supplying and erecting ACSR conductor of size - 6/1-4.72 mm 76,347.00 KM
2 (Dog) complete. (394.00 kg/km) as per specification No.
OH-CON/ACSR
14023 Chapter 8-5-12 Supplying and erecting hard drawn G.I. wire 8 SWG complete 7,299.00 KM
3 erected for overhead line with proper size of G.I. wire for binding
with jumpering etc.
Chapter 8-6 Insulators (OH-INS)
14023 Chapter 8-6-1 Supplying and erecting pin type LT medium insulator 100 63.00 Each
4 mm x 62 mm dia. with suitable G.l. spindle, nut, bolts complete
erected.
14023 Chapter 8-6-2 Supplying and erecting porcelain shackle type LT medium 50.00 Each
5 insulator 75x115 mm dia. with G.l. strips, nuts and bolts,
complete.
14023 Chapter 8-6-3 Supplying and erecting porcelain shackle type LT medium 47.00 Each
6 insulator 50 x 89 mm dia. with G.l. strips, nuts and bolts,
complete.
14023 Chapter 8-6-4 Supplying and erecting aluminium bobbin with G.l. strip, nuts 78.00 Each
7 complete.
14023 Chapter 8-6-5 Providing and fixing earthing stud with necessary materials. 48.00 Each
8
14023 Chapter 8-6-6 Supplying and erecting porcelain disc type insulator suitable for 997.00 Each
9 11kV line, complete as per specification No. OH-INS/DI
14024 Chapter 8-6-7 Supplying and erecting porcelain disc type insulator suitable for 1,359.00 Each
0 22kV line, complete as per specification No. OH-INS/DI
14024 Chapter 8-6-8 Supplying and erecting porcelain disc type insulator suitable for 1,711.00 Each
1 33 kV line complete as per specification No. OH-INS/DI
14024 Chapter 8-6-9 Supplying and erecting porcelain pin type insulator suitable for 237.00 Each
2 11kV line, complete as per specification No. OH-INS/PN
14024 Chapter 8-6-10 Supplying and erecting porcelain pin type insulator suitable for 298.00 Each
3 22kV line, complete as per specification No. OH-INS/PN
14024 Chapter 8-6-11 Supplying and erecting porcelain pin type insulator suitable for 612.00 Each
4 33kV line, complete as per specification No. OH-INS/PN
Rate In (Rs)
Item Description Rate Unit
14024 Chapter 8-6-12 Supplying and erecting porcelain post type insulator suitable for 474.00 Each
5 11kV line, complete as per specification No. OH-INS/PST
14024 Chapter 8-6-13 Supplying and erecting porcelain post type insulator suitable for 567.00 Each
6 22kV line,complete as per specification No. OH-INS/PST
14024 Chapter 8-6-14 Supplying and erecting porcelain post type insulator suitable for 759.00 Each
7 33kV line, complete as per specification No. OH-INS/PST
14024 Chapter 8-6-15 Supplying and erecting Distribution class, 11 kV thyrite type 1,070.00 Each
8 lightening arrester, on provided cross arm as per specification No.
OH-INS/LA
14024 Chapter 8-6-16 Supplying and erecting Distribution class, 22 kV thyrite type 1,080.00 Each
9 lightening arresters, on provided cross arm as per specification
No. OH-INS/LA
Chapter 8-7 Accessories
14025 Chapter 8-7-1 Supplying and erecting G.l. stay set for poles, including loop 1,231.00 Each
0 insulators at inaccessible height complete with anchor plate
300 x 300 x 6 mm., straining screws, G.l. stay wire 7/10
SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly
erected in provided cement concrete foundation.
14025 Chapter 8-7-2 Supplying and erecting G.l. stay set for poles, including loop 1,444.00 Each
1 insulators at inaccessible height complete with anchor plate
300 x 300 x 6 mm., straining screws, G.l. stay wire 7/8 SWG,
G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected
in provided cement concrete foundation.
14025 Chapter 8-7-3 Supplying and erecting G.I. fly stay set for pole including 1,753.00 Each
2 straining screw, G.l. stay wire, 7/10 SWG (for to 15mtr. long) with
pole clamp, made of 50 x 6 mm MS flat, complete erected on
provided RSJ pole. (Add. Rs. 25/- per m for extra length beyond
15 m)
14025 Chapter 8-7-4 Supplying and erecting G.l. self stay set for pole, including 1,444.00 Each
3 anchor plate 300x 300 x 6 mm. straining screw, loop-insulator,
G.l. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m long,
erected with pole clamps along with angle iron bracket of 50 x 50
x 6 mm and one meter long fixed to pole at suitable height
with suitable MS clamps duly erected in provided C.C.
foundations.
14025 Chapter 8-7-5 Supplying and erecting G.l. wall hook, 10 to 15 mm dia and 49.00 Each
4 overall length 250 mm including grouting, cement plastering etc.
complete.
Rate In (Rs)
Item Description Rate Unit
14025 Chapter 8-7-6 Supplying and erecting pipe post made from ISI mark G.I. pipe 40 1,065.00 Each
5 mm dia 3 m overall length, with two bends, fixed to pipe at the
top & bottom, round bended, complete erected with MS flat welded
MS bolts 15 cm long duly grouted in wall with necessary clamps,
nuts and bolts etc. duly painted with two coats of aluminium paint
complete.
14025 Chapter 8-7-7 Supplying and erecting pipe post made from ISI mark G.I. pipe 25 961.00 Each
6 mm dia 3 m overall length, with two bends, fixed to pipe at the
top & bottom, round bended, complete erected with MS flat welded
MS bolts 15 cm long duly grouted in wall with necessary clamps,
nuts and bolts etc. duly painted with two coats of aluminium paint
complete.
14025 Chapter 8-7-8 Supplying and erecting guarding loop using G.l. wire No. 8 SWG 43.00 Each
7 for L.T. over head line of horizontal formation complete erected
with 20 SWG G.l. wire as binding wire and 50 mm. section on
each side, complete.
14025 Chapter 8-7-9 Supplying and erecting fibre/ PVC spacers for L.T. overhead line 3 102.00 Each
8 to 5 conductors complete erected.
14025 Chapter 8-7-10 Supplying and erecting pole clamp made from 50 x 6 mm MS 212.00 Each
9 flat for pole or pipe, post complete erected with 15 mm bolts and
nuts, complete duly painted with one coat of red oxide and two
coats of aluminium paint.
14026 Chapter 8-7-11 Supplying and erecting pole clamp made from 50 x 10 mm 235.00 Each
0 MS flat for pole or pipe, post complete erected with 15 mm bolts
and nuts, complete duly painted with one coat of red oxide and
two coats of aluminium paint. .
14026 Chapter 8-7-12 Supplying and erecting ‘D’ type pole clamps, fabricated from 50 119.00 Each
1 x 6 mm MS flat with 15 mm dia. bolts and nut fixed to steel
tubular pole duly painted with one coat of red oxide and two
coats of aluminium paint.
14026 Chapter 8-7-13 Supplying and erecting half clamps for pole made from 50 x 6 119.00 Each
2 mm flat for fixing cross arms by means of 15 mm dia. bolts and
nuts painted with one coat of red oxide and two coats of
aluminium paint.
14026 Chapter 8-7-14 Supplying and erecting half clamps for pole made from 50 x 10 151.00 Each
3 mm flat for fixing cross arms by means of 15 mm dia. bolts and
nuts painted with one coat of red oxide and two coats of
aluminium paint.
14026 Chapter 8-7-15 Supplying and fixing MS base plate 30x30x0.6 cm size fixed to 379.00 Each
4 the pole base either by welding or by set screws 12 mm. dia fixed
Electrical - 2018-2019 at position.
- 01/04/2018 - Page 146 of 259 05/06/18 12:15
Chapter 8
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
at position.
14026 Chapter 8-7-16 Supplying and fixing MS round base plate 25 cm dia meter and 376.00 Each
5 10mm. thick fixed to pole by set screws or welded and fixed at
position.
14026 Chapter 8-7-17 Supplying and fixing MS pole cap fabricated from MS pipe or 98.00 Each
6 cast iron fixed to pole by means of set screws and 75 mm deep.
14026 Chapter 8-7-18 Supplying and erecting guarding lace for H.T.O.H. line with 8 SWG 41.00 Each
7 G.l. wire to protect the H.T. over head line with binding wire of 20
SWG G.l. wire for 75 mm section on either side.
Chapter 8-8 Dismantling
14026 Chapter 8-8-1 Dismantling the existing pole up to 6 m height with brackets, 416.00 Each
8 clamps, insulators, stay from the cement concrete foundation
and making the site clear by refilling the pits with excavated
materials and bringing it to the ground level.
14026 Chapter 8-8-2 Dismantling the existing pole above 6 m height with brackets, 678.00 Each
9 clamps, insulators, stay from the cement concrete foundation
and making the site clear by refilling the pits with excavated
materials and bringing it to the ground level.
14027 Chapter 8-8-3 Dismantling the existing overhead line including G.I. wires of all 941.00 KM
0 sizes without damaging & making the coils in suitable sizes.
14027 Chapter 8-8-4 Dismantling existing lightning arrestor set, insulator complete from 79.00 Per Job
1 DP structure in an approved manner
Specification:
Rate In (Rs)
Item Description Rate Unit
14028 Chapter 9 -2-3 Supplying and erecting GI strip of required size used for earthing 178.00 kg
0 on wall and/or any other purpose with necessary GI clamps fixed
on wall painted with bituminous paint in an approved manner with
joints required. As per specification No EA-EP.
14028 Chapter 9 -2-4 Supplying and erecting Annealed bare copper wire of high purity 703.00 kg
1 of different sizes used for earthing on wall with necessary
copper clamps fixed on wall/cable/conduit with screws in an
approved manner.
14028 Chapter 9 -2-5 Supplying and erecting G. I. Earth Wire of high purity of different 143.00 kg
2 sizes used for earthing or any other purposes on wall with
necessary G. I. Clamps fixed on wall/cable/ conduit with screws in
an approved manner.
14028 Chapter 9 -2-6 Supplying and erecting aluminium strip of required sizes used 615.00 kg
3 for earthing on wall and/or any other purpose with necessary
aluminium clamps fixed on wall with insulating and non corrosive
bond in an approved manner with joints required. As per
specification No EA-EP.
14028 Chapter 9 -2-7 Supplying and erecting copper strip of required size used for 1,048.00 kg
4 earthing on wall and/or any other purpose with necessary copper
clamps fixed on wall painted with insulating and non corrosive
bond in an approved manner with joints required. As per
specification No EA-EP.
14028 Chapter 9 -2-8 Supplying and erecting GI strip of required size used for earthing 418.00 kg
5 on wall and/or any other purpose with necessary GI clamps fixed
on wall painted with insulating and non corrosive bond in an
approved manner with joints required. As per specification No
EA-EP.
Chapter 9 -3 Lightning Conductor and Accessories
14028 Chapter 9 -3-1 Supplying & erecting conventional spike type air termination 4,245.00 Each
6 suitable to carry lightning stroke made up of heavy gauge 40 mm
dia copper pipe of standard length with 5 Nos. copper spikes fixed
on copper ball as air terminals duly threaded in copper pipe
erected on provided foundation in an approved manner.
14028 Chapter 9 -3-2 Providing and Back filling earth conductivity enhancing mineral 4,955.00 Each
7 earthing compound of 25 kg Bag complete.
Specification:
Rate In (Rs)
Item Description Rate Unit
14029 Chapter 10-1-4 Supplying and Erecting approved make 200 kVA,3 phase, 50 c/s 5,21,249.00 Each
1 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 11/0.433 kV
with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 780 watts at 50% load, 2300 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14029 Chapter 10-1-5 Supplying and Erecting approved make 250 kVA,3 phase, 50 c/s 6,07,008.00 Each
2 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 11/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 980 watts at 50% load, 2930 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14029 Chapter 10-1-6 Supplying and Erecting approved make 315 kVA,3 phase, 50 c/s 6,80,899.00 Each
3 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 11/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 1025 watts at 50% load, 3100 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14029 Chapter 10-1-7 Supplying and Erecting approved make 500 kVA,3 phase, 50 c/s 8,71,985.00 Each
4 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Electrical - 2018-2019 - 01/04/2018 - Page 151 of 259 05/06/18 12:15
Exceeding 4000 C by thermometer in oil and 4500C by the
Chapter 10
resistance in winding at full load rating, voltage rating 11/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 1510 watts at 50% load, 4300 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14030 Chapter Supplying and Erecting approved make 315 kVA,3 phase, 50 c/s 7,63,944.00 Each
1 10-1-14 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 22/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 1077 watts at 50% load, 3255 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14030 Chapter Supplying and Erecting approved make 500 kVA,3 phase, 50 c/s 9,65,177.00 Each
2 10-1-15 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 22/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 1586 watts at 50% load, 4515 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14030 Chapter Supplying and Erecting approved make 630 kVA,3 phase, 50 c/s 12,58,414. Each
3 10-1-16 Oil immersed and naturally cooled outdoor type, Copper wound
transformer with Energy Efficieny Level -2 , BIS Standard with
delta connected. on HV side & star connection on LV side with
additional neutral brought out on load side,Temp rise should not
Exceeding 4000 C by thermometer in oil and 4500C by the
resistance in winding at full load rating, voltage rating 22/ 0.433
kV with HV tapping( with off load tap changer) Tappings on
Transformer For Off Load +5 to -10 in Steps of 2.5% ,with
standard accessories complete with Test Certificate with losses
below 1953 watts at 50% load, 5565 watts at 100% load as per
IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14030 Chapter Inspection of faulty distribution transformer 11kV / 22kV on HV 3,301.00 Per Job
4 10-1-17 side, 415 V on LV side upto 500 kVA capacity in workshop in
presence of authority by opening top cover, disconnecting HV & LV
studs, tap changer connections; taking out core along with winding
for inspection and carrying out necessary tests on HV, LV side, oil,
Electrical - 2018-2019 - 01/04/2018 - Page 154 of 259 05/06/18 12:15
tap-changer etc. checking breather, body condition etc. and
Chapter 10
submitting inspection report, test reports (oil, insulation,
resistance, ratio,etc.) and quotation for repairs, (excluding
transportation)
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
for inspection and carrying out necessary tests on HV, LV side, oil,
tap-changer etc. checking breather, body condition etc. and
submitting inspection report, test reports (oil, insulation,
resistance, ratio,etc.) and quotation for repairs, (excluding
transportation)
14030 Chapter Providing and maintaining distribution transformer 11kV / 22 kV on 16,413.00 Per Job
5 10-1-18 HV side 415 V on LV side up to 63 to 200 kVA Capacity for ten
days on hired basis.
14030 Chapter Providing and maintaining distribution transformer 11kV / 22 kV on 25,792.00 Per Job
6 10-1-19 HV side 415 V on LV side up to 250 to 500 kVA Capacity for ten
days on hired basis.
14030 Chapter Providing and maintaining distribution transformer 11/ 22 kV on 116.00 day
7 10-1-20 HV side 415 V on LV side upto 500 kVA capacity on hired basis
subsequent to first ten days after commissioning.
14030 Chapter Erecting 11kV / 22 kV on HV side 415 V on LV side up to 500 kVA 10,513.00 Per Job
8 10-1-21 capacity hired/provided transformer on existing plinth / DP
structure, making connections on HV & LV side in approved
manner, carrying out necessary tests before and after charging
upto full load to satisfaction.(including transportation)
14030 Chapter Supplying and Erecting approved make 15 kVA,SINGLE PHASE, 87,496.00 Each
9 10-1-22 11 kV/V3/250V Oil cooled with CSP Features outdoor type,
Alluminium wound transformer with Energy Efficieny Level -2 , BIS
Standard ,Temp rise should not Exceeding 400 0C by thermometer
in oil and 4500C by the resistance in winding at full load
rating,with 5 % continuously rated for full load with standard
accessories complete with Test Certificate with losses should be
below 82 Watt at 50% Load & 224 Watt at 100 % Load & first
filling of oil having Vector Group- DYN-11 & first filling of silica gel,
as per IS:1180 - 2014 Level II as per specification No SS-
TR.with necessary permission of Electrical Inspector
14031 Chapter Supplying and Erecting approved make 25 kVA,SINGLE PHASE, 1,06,271.00 Each
0 10-1-23 11 kV/V3/250V Oil cooled with CSP Features outdoor type,
Alluminium wound transformer with Energy Efficieny Level -2 , BIS
Standard ,Temp rise should not Exceeding 4000 C by thermometer
in oil and 4500C by the resistance in winding at full load
rating,with 5 % continuously rated for full load with standard
accessories complete with Test Certificate with losses should be
below 110 Watt at 50% Load & 300Watt at 100 % Load & first
filling of oil having Vector Group- DYN-11 & first filling of silica gel,
as per IS:1180 - 2014 Level II ) as per specification No SS-
TR.with necessary permission of Electrical Inspector
Rate In (Rs)
Item Description Rate Unit
14031 Chapter Supplying and Erecting approved make Compact Substation with 7,20,729.00 Each
1 10-1-24 63 kVA,3 phase, 50 c/s Oil immersed Copper wound transformer
having INDOOR TYPE TRANSFORMER BUSHINGS,with Energy
Efficieny Level -2 , BIS Standard voltage rating 11/ 0.433 kV with
HT side (Incoming side) LOAD BREAK SWITCH of Appropriate
Capacity and LT side (Outgoing side) MCCBs (4 Pole) of
appropriate Capacity , with Metering Cubical Inbuilt,with standard
accessories complete with Test Certificate with losses below 340
watts at 50% load, 1140 watts at 100% load for Transformer, as
per IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14031 Chapter Supplying and Erecting approved make Compact Substation with 8,03,365.00 Each
2 10-1-25 100 kVA,3 phase, 50 c/s Oil immersed Copper wound transformer
having INDOOR TYPE TRANSFORMER BUSHINGS,with Energy
Efficieny Level -2 , BIS Standard voltage rating 11/ 0.433 kV with
HT side (Incoming side) LOAD BREAK SWITCH of Appropriate
Capacity and LT side (Outgoing side) MCCBs (4 Pole) of
appropriate Capacity , with Metering Cubical Inbuilt,with standard
accessories complete with Test Certificate with losses below 475
watts at 50% load, 1650 watts at 100% load for Transformer, as
per IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14031 Chapter Supplying and Erecting approved make Compact Substation with 9,62,259.00 Each
3 10-1-26 160 kVA,3 phase, 50 c/s Oil immersed Copper wound transformer
having INDOOR TYPE TRANSFORMER BUSHINGS,with Energy
Efficieny Level -2 , BIS Standard voltage rating 11/ 0.433 kV with
HT side (Incoming side) LOAD BREAK SWITCH of Appropriate
Capacity and LT side (Outgoing side) MCCBs (4 Pole) of
appropriate Capacity , with Metering Cubical Inbuilt,with standard
accessories complete with Test Certificate with losses below 670
watts at 50% load, 1950 watts at 100% load for Transformer, as
per IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
14031 Chapter Supplying and Erecting approved make Compact Substation with 11,09,014.00 Each
4 10-1-27 200 kVA,3 phase, 50 c/s Oil immersed Copper wound transformer
having INDOOR TYPE TRANSFORMER BUSHINGS,with Energy
Efficieny Level -2 , BIS Standard voltage rating 11/ 0.433 kV with
HT side (Incoming side) LOAD BREAK SWITCH of Appropriate
Capacity and LT side (Outgoing side) MCCBs (4 Pole) of
appropriate Capacity , with Metering Cubical Inbuilt,with standard
accessories complete with Test Certificate with losses below 780
watts at 50% load, 2300 watts at 100% load for Transformer, as
per IS:1180 - 2014 Level II as per specification No SS- TR.with
necessary permission of Electrical Inspector
Electrical - 2018-2019 - 01/04/2018 - Page 156 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14033 Chapter Supplying and Erecting approved make 750 kVA,3 phase, 50 c/s, 10,43,177. Each
1 10-1-44 Referrance Standard IS:11171 & IS 2026,Vaccum Cast Coil (VCC)
Dry Type Cast Resin Transformer, Copper wound , Dyn11 Vector
Group,with delta connection on HV side & star connection on LV
side with additional neutral brought out on load side,For Indoor
Use Continuous Duty, Average Temp rise of Winding ( at Principal
Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5 Deg C at
full load rating, Voltage rating 11/ 0.433 kV with Tapping( with off
circuit Tap Links type tap changer) Tappings on Transformer For
Off Load +5 to - 5% @ 2.5% in +2/-2 Steps, HV Variation, Class
of Insulation H/H, Method of cooling AN, No Load Loss at Rated
Voltage & Frequency (+15% IS Tol) 1.90 KW, Full Load Loss at
Rated Current 6.75 KW, with 98.86 % Efficiency at Full Load &
99.05 % at 1/2 Full Load, with 75 KV peak Full Wave Lightning
Impulse withstand Voltage with Complete Enclouser having IP 21
Degree of protection, Cable Box arrangement at HV side & Busduct
at LV side ,with rating & Diagram Plate, Base Channel, Earthing
Terminals & WTI Scanner with 3 PT-100 Sensors,etc. standard
accessories complete with Test Certificate (as per IS:11171 ) as
per specification No SS- TR.with necessary permission of Electrical
Inspector
14033 Chapter Supplying and Erecting approved make 1000 kVA,3 phase, 50 12,55,881. Each
2 10-1-45 c/s, Referrance Standard IS:11171 & IS 2026, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 11/ 0.433 kV with
Tapping( with off circuit Tap Links type tap changer) Tappings on
Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps, HV
Variation, Class of Insulation H/H, Method of cooling AN, No Load
Loss at Rated Voltage & Frequency (+15% IS Tol) 2.20 KW, Full
Load Loss at Rated Current 9.25 KW, with 98.87 % Efficiency at
Full Load & 99.11 % at 1/2 Full Load, with 75 KV peak Full Wave
Lightning Impulse withstand Voltage with Complete Enclouser
having IP 21 Degree of protection, Cable Box arrangement at HV
side & Busduct at LV side ,with rating & Diagram Plate, Base
Channel, Earthing Terminals & WTI Scanner with 3 PT-100
Sensors,etc. standard accessories complete with Test Certificate
(as per IS:11171 ) as per specification No SS- TR.with necessary
permission of Electrical Inspector
Rate In (Rs)
Item Description Rate Unit
14033 Chapter Supplying and Erecting approved make 315 kVA,3 phase, 50 c/s, 13,08,638. Each
3 10-1-46 Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 22/ 0.433 kV with
Tapping( with off circuit Bolted Links type tap changer) Tappings
on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps,
HV Variation, Class of Insulation H/H, Method of cooling AN, No
Load Loss at Rated Voltage & Frequency (+15% IS Tol) 1.80 KW,
Full Load Loss at Rated Current 3.00 KW, with 98.50 % Efficiency
at Full Load & 98.41 % at 1/2 Full Load, with 125 KV peak Full
Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
14033 Chapter Supplying and Erecting approved make 400 kVA,3 phase, 50 c/s, 13,35,352. Each
4 10-1-47 Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 22/ 0.433 kV with
Tapping( with off circuit Bolted Links type tap changer) Tappings
on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps,
HV Variation, Class of Insulation H/H, Method of cooling AN, No
Load Loss at Rated Voltage & Frequency (+15% IS Tol) 2.00 KW,
Full Load Loss at Rated Current 3.60 KW, with 98.62 % Efficiency
at Full Load & 98.57 % at 1/2 Full Load, with 125 KV peak Full
Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
Electrical - 2018-2019 - 01/04/2018 - Page 163 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14033 Chapter Supplying and Erecting approved make 500 kVA,3 phase, 50 c/s, 13,72,617. Each
5 10-1-48 Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 22/ 0.433 kV with
Tapping( with off circuit Bolted Links type tap changer) Tappings
on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps,
HV Variation, Class of Insulation H/H, Method of cooling AN, No
Load Loss at Rated Voltage & Frequency (+15% IS Tol) 2.20 KW,
Full Load Loss at Rated Current 4.50 KW, with 98.68 % Efficiency
at Full Load & 98.69 % at 1/2 Full Load, with 125 KV peak Full
Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
14033 Chapter Supplying and Erecting approved make 630 kVA,3 phase, 50 c/s, 14,15,492. Each
6 10-1-49 Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 22/ 0.433 kV with
Tapping( with off circuit Bolted Links type tap changer) Tappings
on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps,
HV Variation, Class of Insulation H/H, Method of cooling AN, No
Load Loss at Rated Voltage & Frequency (+15% IS Tol) 2.50 KW,
Full Load Loss at Rated Current 5.50 KW, with 98.75 % Efficiency
at Full Load & 98.78 % at 1/2 Full Load, with 125 KV peak Full
Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
Electrical - 2018-2019 - 01/04/2018 - Page 164 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14033 Chapter Supplying and Erecting approved make 750 kVA,3 phase, 50 c/s, 14,63,142. Each
7 10-1-50 Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast Coil
(VCC) Dry Type Cast Resin Transformer, Copper wound , Dyn11
Vector Group,with delta connection on HV side & star connection
on LV side with additional neutral brought out on load side,For
Indoor Use Continuous Duty, Average Temp rise of Winding ( at
Principal Tap) 115 Deg C at Ambient Temp Max 50 Deg C & Min -5
Deg C at full load rating, Voltage rating 22/ 0.433 kV with
Tapping( with off circuit Bolted Links type tap changer) Tappings
on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2 Steps,
HV Variation, Class of Insulation H/H, Method of cooling AN, No
Load Loss at Rated Voltage & Frequency (+15% IS Tol) 2.60 KW,
Full Load Loss at Rated Current 7.00 KW, with 98.74 % Efficiency
at Full Load & 98.85 % at 1/2 Full Load, with 125 KV peak Full
Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
14033 Chapter Supplying and Erecting approved make 1000 kVA,3 phase, 50 15,91,433. Each
8 10-1-51 c/s, Referrance Standard IS 11171 & IEC 60076-11, Vaccum Cast
Coil (VCC) Dry Type Cast Resin Transformer, Copper wound ,
Dyn11 Vector Group,with delta connection on HV side & star
connection on LV side with additional neutral brought out on load
side,For Indoor Use Continuous Duty, Average Temp rise of
Winding ( at Principal Tap) 115 Deg C at Ambient Temp Max 50
Deg C & Min -5 Deg C at full load rating, Voltage rating 22/ 0.433
kV with Tapping( with off circuit Bolted Links type tap changer)
Tappings on Transformer For Off Load +5 to - 5% @ 2.5% in +2/-2
Steps, HV Variation, Class of Insulation H/H, Method of cooling AN,
No Load Loss at Rated Voltage & Frequency (+15% IS Tol) 3.20
KW, Full Load Loss at Rated Current 9.30 KW, with 98.77 %
Efficiency at Full Load & 98.91 % at 1/2 Full Load, with 125 KV
peak Full Wave Lightning Impulse withstand Voltage with Complete
Enclouser having IP 23 Degree of protection, Cable Box
arrangement at HV side & Busduct at LV side ,with rating &
Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals &
WTI Scanner with 3 PT-100 Sensors,etc. standard accessories
complete with Test Certificate (as per IS:11171) as per
specification No SS- TR.with necessary permission of Electrical
Inspector
Electrical - 2018-2019 - 01/04/2018 - Page 165 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14033 Chapter Supplying and Erecting approved make Compact Substation with 16,22,753. Each
9 10-1-52 100 kVA,3 phase, 50 c/s ONAN Type UNIPACK 21KA for 3 Sec. SF6
insulated Non-Extinsible Compact switchgear (Type DV-NE)
consisting of one No. Direct Cable madule and One No. Fixed
Manual Vacuum Circuit Breaker in SF6 insulated stainless steel
enclosure, with series trip, self powered microprocessor based
numerical over current relay (IDMTL + Inst.) protection.
Interconnection between HT switchgear and transformer shall be
using 1Cx3x95 sq.mm Al. unarmorured XLPE Cable.Copper wound
transformer 100KVA 11KV/433V Dyn11 Oil filled, INDOOR TYPE
TRANSFORMER BUSHINGS,hermatically sealed transformer with
corrugated wall,without conservator type of design & Top Normal
Porcelein Bushings for HT & LT with Off load tap switch of rating
+5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel.
Losses (Subject to IS 1180 Energy Efficiency level 2 ) - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
IS 1180 and Impedance As per IS 1180 with LV PANEL-200 AMPS
ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 200Amps 433V 4P
50Hz 35KA ICOG Fixed Manual Type Moulded case Circuit Breaker
(MCCB) with Microprocessor based release for Overload , short
circuit & earth Fault protection., Multifunctional Meter with Class
1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications,
OUTDOOR ENCLOSURE having IP54 degree of protection for HT &
LT switchgear compartment & IP23 degree of protection for
Transformer compartment, Powder /Colour Coated Enclosure, with
Interconnection Between HT switchgear & Transformer using
1Cx3x95Sq.mm XLPE AL Single core cable. Interconnection
between Transformer & LT switchgear using Al. Busbars. Internal
earthing connections by using 50x6 mm GI Strips including
Transformer Neutral, Complete as per specification No SS-
TR/COMP with necessary permission of Electrical Inspector
14034 Chapter Supplying and Erecting approved make Compact Substation with 17,93,251. Each
0 10-1-53 200 kVA,3 phase, 50 c/s ONAN Type UNIPACK 21KA for 3 Sec. SF6
insulated Non-Extinsible Compact switchgear (Type DV-NE)
consisting of one No. Direct Cable madule and One No. Fixed
Manual Vacuum Circuit Breaker in SF6 insulated stainless steel
enclosure, with series trip, self powered microprocessor based
numerical over current relay (IDMTL + Inst.) protection.
Interconnection between HT switchgear and transformer shall be
using 1Cx3x120 sq.mm Al. unarmorured XLPE Cable.Copper
wound transformer 200KVA 11KV/433V Dyn11 Oil filled, INDOOR
TYPE TRANSFORMER BUSHINGS,hermatically sealed transformer
with corrugated wall,without conservator type of design & Top
Normal Porcelein Bushings for HT & LT with Off load tap switch of
Electrical - 2018-2019 rating
- 01/04/2018
+5% to --10% @2.5%. Page 166Rise
Temp of 259
- Oil/Winding 40/45 Deg 05/06/18 12:15
Chapter 10 cel. Losses (Subject to IS 1180 Energy Efficiency level 2 - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
IS 1180 and Impedance As per IS 1180 with LV PANEL-315 AMPS
ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 315 Amps 433V
4P 50Hz 35KA ICOG Fixed Manual Type Moulded case Circuit
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Normal Porcelein Bushings for HT & LT with Off load tap switch of
rating +5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg
cel. Losses (Subject to IS 1180 Energy Efficiency level 2 - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
IS 1180 and Impedance As per IS 1180 with LV PANEL-315 AMPS
ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 315 Amps 433V
4P 50Hz 35KA ICOG Fixed Manual Type Moulded case Circuit
Breaker (MCCB) with Microprocessor based release for Overload ,
short circuit & earth Fault protection., Multifunctional Meter with
Class 1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications,
OUTDOOR ENCLOSURE having IP54 IP54 degree of protection for
HT & LT switchgear compartment & IP23 degree of protection for
Transformer compartment, Powder /Colour Caoated Enclouser, with
Interconnection Between HT switchgear & Transformer using
1Cx3x120 Sq.mm XLPE AL Single core cable. Interconnection
between Transformer & LT switchgear using Al. Busbars. Internal
earthing connections by using 50x6 mm GI Strips including
Transformer Neutral, Complete as per specification No SS-
TR/COMP with necessary permission of Electrical Inspector
14034 Chapter Supplying and Erecting approved make Compact Substation with 19,07,391. Each
1 10-1-54 315 kVA,3 phase, 50 c/s ONAN Type UNIPACK 21KA for 3 Sec. SF6
insulated Non-Extinsible Compact switchgear (Type DV-NE)
consisting of one No. Direct Cable madule and One No. Fixed
Manual Vacuum Circuit Breaker in SF6 insulated stainless steel
enclosure, with series trip, self powered microprocessor based
numerical over current relay (IDMTL + Inst.) protection.
Interconnection between HT switchgear and transformer shall be
using 1Cx3x150 sq.mm Al. unarmorured XLPE Cable.Copper
wound transformer 315 KVA 11KV/433V Dyn11 Oil filled, INDOOR
TYPE TRANSFORMER BUSHINGS,hermatically sealed transformer
with corrugated wall,without conservator type of design & Top
Normal Porcelein Bushings for HT & LT with Off load tap switch of
rating +5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg
cel. Losses (Subject to IS 1180 Energy Efficiency level 2 - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
IS 1180 and Impedance As per IS 1180 with LV PANEL-500 AMPS
ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 500 Amps 433V
4P 50Hz 35KA ICOG Fixed Manual Type Moulded case Circuit
Breaker (MCCB) with Microprocessor based release for Overload ,
short circuit & earth Fault protection., Multifunctional Meter with
Class 1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications,
OUTDOOR ENCLOSURE having IP54 IP54 degree of protection for
HT & LT switchgear compartment & IP23 degree of protection for
Electrical - 2018-2019 Transformer
- 01/04/2018 compartment,
- Powder
Page 167/Colour
of 259Coated Enclosure, with 05/06/18 12:15
Chapter 10 Interconnection Between HT switchgear & Transformer using
1Cx3x150 Sq.mm XLPE AL Single core cable. Interconnection
between Transformer & LT switchgear using Al. Busbars. Internal
earthing connections by using 50x6 mm GI Strips including
Transformer Neutral, Complete as per specification No SS-
TR/COMP with necessary permission of Electrical Inspector
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
consisting of one No. Direct Cable madule and One No. Fixed
Manual Vacuum Circuit Breaker in SF6 insulated stainless steel
enclosure, with series trip, self powered microprocessor based
numerical over current relay (IDMTL + Inst.) protection.
Interconnection between HT switchgear and transformer shall be
using 1Cx3x185 sq.mm Al. unarmorured XLPE Cable.Copper
wound transformer 630KVA 22 KV/433V Dyn11 Oil filled, INDOOR
TYPE TRANSFORMER BUSHINGS, hermatically sealed transformer
with corrugated wall,without conservator type of design & Top
Normal Porcelein Bushings for HT & LT with Off load tap switch of
rating +5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg
cel. Losses (Subject to IS 1180 Energy Efficiency level 2 ) - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
IS 1180 and Impednace As per IS 1180 with LV PANEL-1000
AMPS ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 1000Amps 433V
4P 50Hz 50KA ICOG Fixed Manual Type Air Circuit Breaker (ACB)
with Microprocessor based release for Overload , short circuit &
earth Fault protection, Multifunctional Meter with Class
1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications,
OUTDOOR ENCLOSURE having IP54 degree of protection for HT &
LT switchgear compartment & IP23 degree of protection for
Transformer compartment, Powder /Colour Coated Enclosure, with
Interconnection Between HT switchgear & Transformer using
1Cx3x185Sq.mm XLPE AL Single core cable. Interconnection
between Transformer & LT switchgear using Al. Busbars. Internal
earthing connections by using 50x6 mm GI Strips including
Transformer Neutral, Complete as per specification No SS-
TR/COMP with necessary permission of Electrical Inspector
14035 Chapter Supplying and Erecting approved make Compact Substation with 28,28,465. Each
1 10-1-64 1000 kVA,3 phase, 50 c/s ONAN Type UNIPACK 21KA for 3 Sec.
SF6 insulated Non-Extinsible Compact switchgear (Type DV-NE)
consisting of one No. Direct Cable madule and One No. Fixed
Manual Vacuum Circuit Breaker in SF6 insulated stainless steel
enclosure, with series trip, self powered microprocessor based
numerical over current relay (IDMTL + Inst.) protection.
Interconnection between HT switchgear and transformer shall be
using 1Cx3x200 sq.mm Al. unarmorured XLPE Cable.Copper
wound transformer 1000KVA 22KV/433V Dyn11 Oil filled, INDOOR
TYPE TRANSFORMER BUSHINGS, hermatically sealed transformer
with corrugated wall,without conservator type of design & Top
Normal Porcelein Bushings for HT & LT with Off load tap switch of
rating +5% to -10% @2.5%. Temp Rise - Oil/Winding 40/45 Deg
cel. Losses (Subject to IS 1180 Energy Efficiency level 2 ) - Max @
50% Loading : As per IS 1180 and Max @ 100% Loading : As per
Electrical - 2018-2019 IS 1180 and Impednace
- 01/04/2018 - As per174
Page IS of1180
259 with LV PANEL-1600 05/06/18 12:15
Chapter 10 AMPS ALUMINUM BUSBAR ( 100% for Phase and 50% for Neutral,
Current Density - 1amp/sqmm) with Outgoings 1600Amps 433V
4P 50Hz 50KA ICOG Fixed Manual Type Air Circuit Breaker (ACB)
with Microprocessor based release for Overload , short circuit &
earth Fault protection, Multifunctional Meter with Class
1.0Accuracy with RS 485 Port, RYB, ON/OFF Trip Indications,
OUTDOOR ENCLOSURE having IP54 IP54 degree of protection for
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14035 Chapter 10-2-4 Supplying and erecting approved make 33 kV out door type gang 38,548.00 Per Set
5 operated air break, triple pole switch 200A, capacity with 3
post pin type insulator double stack per phase, mounted in
horizontal position with necessary channels on provided cross arm
with adequate length of "C" class G.l. pipe for operating handle
erected on extended square shaft. The operating handle
provided with lock and key at suitable height from ground level
with necessary clamp.
14035 Chapter 10-2-5 Supplying and erecting approved make, 11 kV out door type drop 9,695.00 Per Set
6 out fuse with insulator complete with fuse holders, fuse barrel
with metal fitting, fuse element mounted on M.S. channel with
working current of 15 Amps capacity complete erected on
provided cross arm.
14035 Chapter 10-2-6 Supplying and erecting approved make, 22 kV out door type drop 16,237.00 Per Set
7 out fuse with insulator complete with fuse holders, fuse barrel
with metal fitting, fuse element mounted on M.S. channel with
working current of 15 Amps capacity complete erected on
provided cross arm.
14035 Chapter 10-2-7 Supplying and erecting approved make, 33 kV out door type drop 21,513.00 Per Set
8 out fuse with insulator complete with fuse holders, fuse barrel
with metal fitting, fuse element mounted on M.S. channel with
working current of 15 Amps capacity complete erected on
provided cross arm.
14035 Chapter 10-2-8 Supplying and erecting 11 kV fuse barrel with metal fittings. 337.00 Each
9
14036 Chapter 10-2-9 Supplying and erecting 22 kV fuse barrel with metal fittings. 537.00 Each
0
14036 Chapter Supplying and erecting hard drawn copper solid wire No.0 to 6 853.00 kg
1 10-2-10 SWG complete erected for connections on H.T. sides.
14036 Chapter Supplying and erecting extra thick alkathene pipe 10mm. dia 42.00 Meter
2 10-2-11 erected to enclose bare conductor wires. (use shall be restricted
to H.T.)
14036 Chapter Supplying operating rod, suitable for 11/22kV supply with 3,366.00 Each
3 10-2-12 clamps for removing drop out fuses at 6 meters length, 4 pieces
each with rain shade with hand grip including earthing chain 1.5
m (Light duty)
14036 Chapter Supplying Heavy duty operating rod, Outer Dia 25 mm & inner 3,587.00 Each
4 10-2-13 dia 20 mm suitable for 11 kV with brass couplings etc for
removing drop out fuses at 6 meters length, 4 pieces each
with rain shade with hand grip including earthing chain 1.5 m
Electrical - 2018-2019 - 01/04/2018 - Page 176 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14036 Chapter Supplying Heavy duty operating rod, Outer Dia 25 mm & inner 4,326.00 Each
5 10-2-14 dia 20 mm suitable for 22/33 kV with brass couplings etc for
removing drop out fuses at 6 m length, 4 pieces each with rain
shade with hand grip including earthing chain 1.5 m
14036 Chapter Supplying and erecting copper tubular bus 20mm. dia 1.6 mm (16 1,487.00 Meter
6 10-2-15 SWG) thick for the use of high tension over head bus and
erected on provided HT insulators with clamps, nuts and bolts
complete. (weight per meter of bus is about 1.7 kg.)
14036 Chapter Supplying and erecting clamps, made out of 25x3mm, copper 189.00 Each
7 10-2-16 strips to be fixed to tubular bus for connecting the bare copper
wire to other equipment, with brass nuts bolts of suitable dia.
14036 Chapter Supplying and erecting anticlimbing devices, fabricated from pole 149.00 Each
8 10-2-17 clamps of MS Flat 40x5 mm, with drooping spikes 15 cm. in
length, welded to it and erected on pole.
14036 Chapter Supplying and erecting fencing of section having size 2450 mm in 5,188.00 Each
9 10-2-18 height from ground level and 1200 mm width with angle iron
frame work erected in C C foundation and painted as per
specification No SS-AS/FSG
14037 Chapter Supplying and erecting 50 x 50 x 6 mm. angle iron as corner 1,054.00 Each
0 10-2-19 support 2m long fixed at the middle of the fencing frame and the
other side inclined at 30 degree angle, in C.C. foundation of 15 x
15 x 40cm complete duly painted with one coat of red oxide and
two coats aluminum paint.
14037 Chapter Supplying and erecting double leaf hinged door each 1500mm in 15,672.00 Each
1 10-2-20 width x 1850 mm in height using B class ,GI pipe with angle iron
supports, chain link wiremesh (jali) complete supported on channel
iron, erected in foundation, and painted as per specification no
SS-AS/DLD
14037 Chapter Supplying & erecting barbed wire two ply with 12 SWG ply and 12 103.00 kg
2 10-2-21 SWG barb with a gap between two bars of 75 mm. firmly fixed on
provided angle supports with necessary materials. (6.044
meters/kg.).
14037 Chapter Providing printed instruction chart for treating persons suffering 110.00 Each
3 10-2-22 from electric shock, printed in English & Marathi and duly
laminated.
14037 Chapter Providing pair of duly tested rubber hand gloves as per 549.00 Each
4 10-2-23 IS :47705 suitable for working upto 22kV supply.
14037 Chapter Providing Round bottom FIRE Bucket of 9 Litres capacity as per 627.00 Each
5 10-2-24 IS : 2546 made out of 24 gauge G.I. sheet with extra handle at
bottom duly painted white inside and red outside with FIRE Mark,
Electrical - 2018-2019 on
- 01/04/2018 -
provided stand/ Page 177 of 259
wall hook. 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
bottom duly painted white inside and red outside with FIRE Mark,
on provided stand/ wall hook.
14037 Chapter Providing Floor mounting stand for keeping 4 Nos. of FIRE 3,281.00 Each
6 10-2-25 buckets 1500mm in length, 900mm in height frame made out of
30x30x4 mm angle iron with cross supports for legs, welded with
4 hooks and duly painted with one coat of red lead and two
coats of silver paint.
14037 Chapter Supplying and erecting Wall hook 225mm projection for keeping 74.00 Each
7 10-2-26 fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to
a depth of minimum 15cms.
14037 Chapter Supplying standard first aid box with necessary antiseptic cream, 665.00 Each
8 10-2-27 medicine for use on wounds due burn, crepe bandage, gauge
bandage, medicated ready to use bandage (Band-aid) adhesive
tape for medicinal use, scissors, anti-septic solution (Savlon or
similar) etc. (All above contents shall be of standard makes)
14037 Chapter Supplying and fixing PVC Synthetic elastomer electrically 4,279.00 Sq.m
9 10-2-28 insulating mat with class A insulation conforming to IS: 15652 –
2006 & CPRI tested having 2 mm thickness upto 3.3 kV
14038 Chapter Supplying and fixing PVC Synthetic elastomer electrically 4,596.00 Sq.m
0 10-2-29 insulating mat with class B insulation conforming to IS: 15652 –
2006 & CPRI tested having 2.5 mm thickness upto 11 kV
14038 Chapter Supplying and fixing PVC Synthetic elastomer electrically 6,231.00 Sq.m
1 10-2-30 insulating mat with class C insulation conforming to IS: 15652 –
2006 & CPRI tested having 3mm thickness upto 33 kV
14038 Chapter Supplying shock proof leather Safety Shoes of Electrical grade of 1,625.00 pair
2 10-2-31 standard size as IS :11226, 14544 duly tested, with necessary
test certificate from manufacturer.
14038 Chapter Supplying and erecting D.C.P. type Fire Extinguisher 6 kg 3,168.00 Each
3 10-2-32 capacity cartridge type with Gun Metal cap 150 gram CO2 gas
cartridge, powder and brackets conforming to IS 2171-1985/ IS
15683 and complete erected with necessary clamps made from
50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
14038 Chapter Supplying and erecting D.C.P. type Fire Extinguisher 9 kg 4,084.00 Each
4 10-2-33 capacity cartridge type with Gun Metal cap 150 gram CO2 gas
cartridge, powder and brackets conforming to IS 2171-1985 and
complete erected with necessary clamps made from 50x6 mm
M.S. flat with nuts & bolts grouted in wall complete.
14038 Chapter Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 10,208.00 Each
5 10-2-34 kg. Capacity Cartridge type conf. To IS 2878 /15683 Complete
erected with necessary clamp made from 50x6 mm. M. S. flat
Electrical - 2018-2019 with nut & bolts
- 01/04/2018 - grouted in wall
Pagecomplete.
178 of 259 05/06/18 12:15
Chapter 10
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14039 Chapter 11-1-5 Supplying, Erecting and Commissioning of Diesel generating set 3,26,417.00 Each
9 with alternator of 20 kVA output continuous rating, 3 Phase, 415 V,
50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Acoustic enclosure as fully assembled integral unit made of 16
SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
14040 Chapter 11-1-6 Supplying, Erecting and Commissioning of Diesel generating set 3,62,028.00 Each
0 with alternator of 25 kVA output continuous rating, 3 Phase, 415 V,
50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Acoustic enclosure as fully assembled integral unit made of 16
SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
14040 Chapter 11-1-7 Supplying, Erecting and Commissioning of Diesel generating set 3,79,878.00 Each
1 with alternator of 30 kVA output continuous rating, 3 Phase, 415 V,
50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Electrical - 2018-2019 Acoustic enclosure
- 01/04/2018 - as fully Page
assembled integral unit made of 16
181 of 259 05/06/18 12:15
Chapter 11 SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14040 Chapter Supplying, Erecting and Commissioning of Diesel generating set 7,65,990.00 Each
7 11-1-14 with alternator of 125 kVA output continuous rating, 3 Phase, 415
V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Acoustic enclosure as fully assembled integral unit made of 16
SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
14040 Chapter Supplying, Erecting and Commissioning of Diesel generating set 10,23,694. Each
8 11-1-15 with alternator of 140 kVA output continuous rating, 3 Phase, 415
V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Acoustic enclosure as fully assembled integral unit made of 16
SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
14040 Chapter Supplying, Erecting and Commissioning of Diesel generating set 10,29,673. Each
9 11-1-16 with alternator of 160 kVA output continuous rating, 3 Phase, 415
V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Electrical - 2018-2019 Acoustic enclosure
- 01/04/2018 - as fully Page
assembled integral unit made of 16
184 of 259 05/06/18 12:15
Chapter 11 SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as
per specification no. GEN-DG
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
GEN-DG
14041 Chapter Supplying, Erecting and Commissioning of Diesel generating set 21,23,863. Each
5 11-1-22 with alternator of 320 kVA output continuous rating, 3 Phase, 415
V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising meters, switchgears, indicators connected
with suitable wires/cables, the complete set enclosed in composite
Acoustic enclosure as fully assembled integral unit made of 16
SWG CRCA Sheet, sound absorbing material to restrict sound level
upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and
obtaining necessary approval from Electrical Inspector as per
specification no. GEN-DG
14041 Chapter Supplying, Erecting and Commissioning of Diesel generating set 29,04,863. Each
6 11-1-23 with alternator of 500 kVA output continuous rating, 3 Phase, 415
V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled
multi-cylinder diesel engine developing suitable BHP at 1500 rpm
with 10% overload for 1 hour in 12 hours, alongwith standard
accessories, self-excited, self-regulated, screen protected
alternator with static excitation system running at 1500 RPM as
per IS 4722-2001 with voltage regulation +/- 5 %. Both the
engine and alternator direct coupled on a common fabricated steel
base frame and mounted on anti-vibrating pads with standard
control panel comprising of meters, switchgears, indicators
connected with suitable wires/cables, the complete set enclosed in
composite Acoustic enclosure as fully assembled integral unit made
of 16 SWG CRCA Sheet, sound absorbing material to restrict sound
level upto 75 dB at 1.0 m, provided with first filling of oil, diesel
etc. and obtaining necessary approval from Electrical Inspector as
per specification no. GEN-DG
Chapter 11-2 Auto Mains Failure Panels (AMF Panels) (GEN-AMF)
14041 Chapter 11-2-1 Supplying, erecting, testing and commissioning of Microprocessor 49,191.00 Each
7 based AMF panel suitable for Diesel Generating Set of upto 10 kVA
capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all
standard features, safeties etc as per specification no. GEN-AMF.
14041 Chapter 11-2-2 Supplying, erecting, testing and commissioning of Microprocessor 57,820.00 Each
8 based AMF panel suitable for Diesel Generating Set of above 10
kVA upto 15 kVA capacity Single/Three phase, 230/415 Volts,
Electrical - 2018-2019 50Hz
- 01/04/2018 -
A.C. with Page 187
all standard of 259 safeties etc as per
features, 05/06/18 12:15
Chapter 11 specification no. GEN-AMF.
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14044 Chapter 11-3-8 Supplying and erecting V-Belt of all types and lengths, adjust 19,427.00 Each
3 tension as per requirements from generator manufacturer suitable
for DG set from 320 kVA to 500 kVA
14044 Chapter 11-3-9 Supplying and erecting Lub Oil filter element along with sealing 1,157.00 Each
4 rings, gasket etc complete suitable for DG Set upto 62.5 kVA.
14044 Chapter Supplying and erecting Lub Oil filter element along with sealing 4,852.00 Each
5 11-3-10 rings, gasket etc complete suitable for DG Set from 82.5 kVA to
250 kVA.
14044 Chapter Supplying and erecting Lub Oil filter element along with sealing 7,281.00 Each
6 11-3-11 rings, gasket etc complete suitable for DG Set from 320 kVA to
500 kVA.
14044 Chapter Supplying and erecting Fuel filter along with sealing rings, gasket, 1,070.00 Each
7 11-3-12 primary filter and water separator etc complete suitable for DG Set
upto 50 kVA.
14044 Chapter Supplying and erecting Fuel filter along with sealing rings, gasket, 1,261.00 Each
8 11-3-13 primary filter and water separator etc complete suitable for DG Set
from 62.5 kVA to 125 kVA.
14044 Chapter Supplying and erecting Fuel filter along with sealing rings, gasket, 4,692.00 Each
9 11-3-14 primary filter and water separator etc complete suitable for DG Set
from 140 kVA to 200 kVA.
14045 Chapter Supplying and erecting Fuel filter along with sealing rings, gasket, 7,293.00 Each
0 11-3-15 primary filter and water separator etc complete suitable for DG Set
from 250 kVA to 500 kVA.
14045 Chapter Supplying and erecting Stop Solenoid assembly 12V/24V single coil 7,093.00 Each
1 11-3-16 energized to run with or without primary etc complete suitable for
DG set upto 125 kVA.
14045 Chapter Supplying and erecting Stop Solenoid assembly 12V/24V single coil 15,001.00 Each
2 11-3-17 energized to run with or without primary etc complete suitable for
DG set from 140 kVA to 200 kVA.
14045 Chapter Supplying and erecting Stop Solenoid assembly 12V/24V single coil 27,093.00 Each
3 11-3-18 energized to run with or without primary etc complete suitable for
DG set from 250 kVA to 500 kVA.
14045 Chapter Supplying and erecting Air Cleaner/Air Filter Element suitable for 2,697.00 Each
4 11-3-19 DG set upto 40 kVA
14045 Chapter Supplying and erecting Air Cleaner/Air Filter Element suitable for 4,993.00 Each
5 11-3-20 DG set from 50 kVA to 125 kVA
Rate In (Rs)
Item Description Rate Unit
14045 Chapter Supplying and erecting Air Cleaner/Air Filter Element suitable for 9,696.00 Each
6 11-3-21 DG set from 140 kVA to 200 kVA
14045 Chapter Supplying and erecting Air Cleaner/Air Filter Element suitable for 27,997.00 Each
7 11-3-22 DG set from 250 kVA to 500 kVA
14045 Chapter Supplying, erecting and testing permanent magnet generator 55,240.00 Each
8 11-3-23 (PMG) excited Automatic Voltage Regulator (AVR) with sensing
input voltage range: 190 V AC - 264 V AC 2/3 Phase, frequency
range 50-60 Hz and output voltage max 120 V DC continuous
current 3.7 A, transient current 6 A for 10 second with minimum
resistance of 15 ohm, AVR response time of 10 ms etc. complete
suitable for DG set as per Specification GEN-SER-AVR
14045 Chapter Supplying, erecting and testing permanent magnet generator 50,097.00 Each
9 11-3-24 (PMG) excited Automatic Voltage Regulator (AVR) with sensing
input voltage range: 190 V AC - 264 V AC 1 Phase 2 wire,
frequency range 50-60 Hz and output voltage max 120 V DC
continuous current 2.7 A, transient current 6 A for 10 second with
minimum resistance of 15 ohm, AVR response time of 10 ms etc.
complete suitable for DG set as per Specification GEN-SER-AVR
14046 Chapter Supplying, erecting and testing main stator powered excited 17,829.00 Each
0 11-3-25 Automatic Voltage Regulator (AVR) with sensing input voltage
range: 95 V - 132 V /190 V AC - 264 V AC 1 Phase 2 wire,
frequency range 50-60 Hz and output voltage max 90 V DC
continuous current 4 A, transient current 6 A for 10 second with
minimum resistance of 15 ohm, AVR response time of 20 ms etc.
complete suitable for DG set as per Specification GEN-SER-AVR
14046 Chapter Supplying, erecting and testing main stator powered excited 24,504.00 Each
1 11-3-26 Automatic Voltage Regulator (AVR) with sensing input voltage
range: 190 V AC - 264 V AC, frequency range 50-60 Hz and output
voltage max 90 V DC continuous current 10 A, transient current 16
A for 10 second with minimum resistance of 10 ohm, AVR
response time of 20 ms etc. complete suitable for DG set as per
Specification GEN-SER-AVR
14046 Chapter Supplying, erecting and testing main stator powered excited 19,791.00 Each
2 11-3-27 Automatic Voltage Regulator (AVR) with sensing input voltage
range: 170 V AC - 280 V AC 1 phase/ 270 V - 520 V AC 3 phase,
frequency range 50-60 Hz and output voltage max 63 V DC
continuous current 6 A, transient current 7 A for 10 second with
minimum resistance of 10 ohm, AVR response time of 20 ms etc.
complete suitable for DG set as per Specification no GEN-SER-AVR
14046 Chapter Supplying and erecting set of Engine Safety Unit suitable for DG 12,358.00 Each
3 11-3-28 set upto 125 kVA as per specification no
Electrical - 2018-2019 - 01/04/2018 - Page 193 of 259 05/06/18 12:15
Chapter 11
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14046 Chapter Supplying and erecting set of Engine Safety Unit suitable for DG 16,391.00 Each
4 11-3-29 set from 140 kVA to 250 kVA
14046 Chapter Supplying and erecting set of Engine Safety Unit suitable for DG 21,366.00 Each
5 11-3-30 set from 320 kVA to 500 kVA
14046 Chapter Supplying and erecting SMPS based Battery Charger input voltage 9,126.00 Each
6 11-3-31 230 V A.C. & output voltage 24 V DC, charging current 10A
suitable to charge DG set Battery
14046 Chapter Supplying and erecting SMPS based Battery Charger input voltage 15,541.00 Each
7 11-3-32 230 V A.C. & output voltage 24 V DC, charging current 20A
suitable to charge DG set Battery
14046 Chapter Supplying and erecting SMPS Battery Charger input voltage 230 V 2,477.00 Each
8 11-3-33 A.C. & output voltage 12 V DC, charging current 10A suitable to
charge DG set Battery
14046 Chapter Supplying, erecting, testing and commissioning 4 pole power 1,765.00 Each
9 11-3-34 contactor 32A with coil voltage of 220/240 V suitable to operate on
AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 4,020.00 Each
0 11-3-35 contactor 63 A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 7,203.00 Each
1 11-3-36 contactor 80-130A with coil voltage of 220/240 V suitable to
operate on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 16,194.00 Each
2 11-3-37 contactor 200A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 32,690.00 Each
3 11-3-38 contactor 325A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 41,861.00 Each
4 11-3-39 contactor 400A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 63,109.00 Each
5 11-3-40 contactor 600A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
14047 Chapter Supplying, erecting, testing and commissioning 4 pole power 95,396.00 Each
6 11-3-41 contactor 800A with coil voltage of 220/240 V suitable to operate
on AV voltage for DG set.
Rate In (Rs)
Item Description Rate Unit
14047 Chapter Supplying, erecting, testing and comissioning microcontroller 2,262.00 Each
7 11-3-42 based Digital Line Voltage Monitor 3 phase 4 wire 2 CO output
relay suitable to operate on AC voltage for DG set.
14047 Chapter Supplying & erecting 12 V 80 AH heavy duty plate type Battery 7,212.00 Each
8 11-3-43 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14047 Chapter Supplying & erecting 12 V 88 AH heavy duty plate type Battery 7,512.00 Each
9 11-3-44 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14048 Chapter Supplying & erecting 12 V 100 AH heavy duty plate type Battery 8,841.00 Each
0 11-3-45 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14048 Chapter Supplying & erecting 12 V 150 AH heavy duty plate type Battery 14,194.00 Each
1 11-3-46 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14048 Chapter Supplying & erecting 12 V 180 AH heavy duty plate type Battery 16,479.00 Each
2 11-3-47 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14048 Chapter Supplying & erecting 12 V 200 AH heavy duty plate type Battery 21,317.00 Each
3 11-3-48 with terminal wire duly charged complete suitable for DG set with
warranty for 3 years
14048 Chapter Topping up Distilled water for Battery 22.00 litre
4 11-3-49
Chapter 11-4 Dismantling
14048 Chapter 11-4-1 Dismantling unserviceable DG set upto 50 kVA capacity alongwith 1,331.00 Per Job
5 Switch gears & panel, etc. and remaking the site good as original.
14048 Chapter 11-4-2 Dismantling unserviceable DG set above 50 kVA capacity alongwith 24.00 kVA
6 Switch gears & panel, etc. and remaking the site good as original.
Specification:
Rate In (Rs)
Item Description Rate Unit
14049 Chapter 12-1-9 Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 22,069.00 Each
5 three phase 50 cycles A.C. supply of 5 HP with discharge 2/4.1
Liters per second (LPS) for head of 36/52 m and 50 mm suction/
40 mm delivery pipe on provided C.C. foundation as per
specification No. WP-CGP
14049 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 20,649.00 Each
6 12-1-10 three phase 50 cycles A.C. supply of 5 HP with discharge 5.8/8.5
Liters per second (LPS) for head of 20/36 m and 65 mm suction/
50 mm delivery pipe on provided C.C. foundation as per
specification No. WP-CGP
14049 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 26,294.00 Each
7 12-1-11 three phase 50 cycles A.C. supply of 7.5 HP with discharge
4.5/8.6 Liters per second (LPS) for head of 32/52 m and 65 mm
suction/ 50 mm delivery pipe of size or with discharge of 11.1/19.9
Liters per second (LPS) for head of 16/30 m and 80mm suction/
65mm delivery pipe of size, on provided C.C. foundation as per
specification No. WP-CGP
14049 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 31,734.00 Each
8 12-1-12 three phase 50 cycles A.C. supply of 10 HP with discharge
9.6/21.6 Liters per second (LPS) for head of 18/40 m and 80 mm
suction/ 65 mm delivery pipe of size or with discharge of 4.3/7.8
Liters per second (LPS) for head of 40/64 m and 65mm suction/
50mm delivery pipe of size, on provided C.C. foundation as per
specification No. WP-CGP
14049 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 39,206.00 Each
9 12-1-13 three phase 50 cycles A.C. supply of 12.5 HP with discharge
7/19.6 Liters per second (LPS) for head of 20/48 m and 80 mm
suction/ 65 mm delivery pipe of size or with discharge of 20/33.5
Liters per second (LPS) for head of 18/30 m and 100mm suction/
100mm delivery pipe of size, on provided C.C. foundation as per
specification No WP-CGP
14050 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 43,190.00 Each
0 12-1-14 three phase 50 cycles A.C. supply of 15 HP with discharge
10.5/19.4 Liters per second (LPS) for head of 30/54 m and 80 mm
suction/ 65 mm delivery pipe of size or with discharge of 17.5/36.8
Liters per second (LPS) for head of 18/36 m and 100mm suction/
100mm delivery pipe of size, on provided C.C. foundation as per
specification No. WP-CGP
14050 Chapter Supplying & erecting Centrifugal water pump (Monoblock), 415 V, 55,509.00 Each
1 12-1-15 three phase 50 cycles A.C. supply of 20 HP with discharge
14/33.8 Liters per second (LPS) for head of 18/52 m and 100mm
suction/ 80mm delivery pipe of size, on provided C.C. foundation
Electrical - 2018-2019 as
- 01/04/2018 -
per specification Page 197 of 259
No. WP-CGP 05/06/18 12:15
Chapter 12
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14053 Chapter Supplying and erecting submersible pumpset of required HP with 25,206.00 Each
6 12-3-33 230 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable
for 84 to 40 LPM discharge at 30 to 90 m head & (max. efficiency
at 69 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14053 Chapter Supplying and erecting submersible pumpset of required HP with 20,818.00 Each
7 12-3-34 230 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable
for 42 to 20 m head at 30 to 90LPM discharge & (max. efficiency
at 34 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14053 Chapter Supplying and erecting submersible pumpset of required HP with 16,711.00 Each
8 12-3-35 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 45 to 13 m head & (max. efficiency
at 33 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14053 Chapter Supplying and erecting submersible pumpset of required HP with 17,301.00 Each
9 12-3-36 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 54 to 15 m head & (max. efficiency
at 39 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 17,506.00 Each
0 12-3-37 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 72 to 20 m head & (max. efficiency
at 33 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 16,847.00 Each
1 12-3-38 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 85 to 170 LPM discharge at 32 to 12 m head & (max. efficiency
at 24 m head & 130 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 17,736.00 Each
2 12-3-39 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 30 to 90 LPM discharge at 42 to 20 m head & (max. efficiency
at 34 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
Electrical - 2018-2019 - 01/04/2018 - Page 203 of 259 05/06/18 12:15
Chapter 12
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 18,499.00 Each
3 12-3-40 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 30 to 90 LPM discharge at 51 to 25 m head & (max. efficiency
at 42 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 17,861.00 Each
4 12-3-41 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 32 to 12 m head & (max. efficiency
at 26 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 20,298.00 Each
5 12-3-42 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 109 to 30 m head & (max. efficiency
at 78 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 22,364.00 Each
6 12-3-43 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 127 to 35 m head & (max. efficiency
at 91 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 22,415.00 Each
7 12-3-44 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 30 to 90 LPM discharge at 84 to 40 m head & (max. efficiency
at 69 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 22,186.00 Each
8 12-3-45 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 127 to 35 m head & (max. efficiency
at 91 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14054 Chapter Supplying and erecting submersible pumpset of required HP with 24,600.00 Each
9 12-3-46 230 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 10 to 50 LPM discharge at 144 to 40 m head & (max. efficiency
at 104 m head & 30 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
Electrical - 2018-2019 WP-SMP
- 01/04/2018 - Page 204 of 259 05/06/18 12:15
Chapter 12
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14057 Chapter Supplying and erecting submersible pumpset of required HP with 28,314.00 Each
0 12-3-67 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 30 to 90 LPM discharge at 147 to 70 m head & (max. efficiency
at 119 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14057 Chapter Supplying and erecting submersible pumpset of required HP with 30,112.00 Each
1 12-3-68 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 30 to 90 LPM discharge at 168 to 80 m head & (max. efficiency
at 136 m head & 60 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14057 Chapter Supplying and erecting submersible pumpset of required HP with 27,374.00 Each
2 12-3-69 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 85 to 170 LPM discharge at 88 to 36 m head & (max. efficiency
at 68 m head & 130 lpm) discharge & delivery pipe of necessary
diameter with a necessary H type clamps as per specification No.
WP-SMP
14057 Chapter Supplying and erecting submersible pumpset of required HP with 29,680.00 Each
3 12-3-70 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 85 to 170 LPM discharge at 110 to 46 m head & (max.
efficiency at 83 m head & 130 lpm) discharge & delivery pipe of
necessary diameter with a necessary H type clamps as per
specification No. WP-SMP
14057 Chapter Supplying and erecting submersible pumpset of required HP with 32,864.00 Each
4 12-3-71 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable
for 85 to 170 LPM discharge at 133 to 55 m head & (max.
efficiency at 100 m head & 130 lpm) discharge & delivery pipe of
necessary diameter with a necessary H type clamps as per
specification No. WP-SMP
Chapter 12-4 Submersible Pumps for Open wells (WP-OSP)
14057 Chapter 12-4-1 Supplying and erecting submersible pump set suitable for erection 17,898.00 Each
5 on open well of required HP with 415 V 50 c/s.A.C. supply, having
delivery head from 21 to 7 m and discharge from 200 to 800 Itrs.
per minute (Max efficiency at 16 m head & 500 Itr discharge) &
delivery pipe of necessary diameter erected with necessary H type
clamps as per specification No. WP-OSP
14057 Chapter 12-4-2 Supplying and erecting submersible pump set suitable for erection 19,621.00 Each
6 on open well of required HP with 415 V 50 c/s.A.C. supply, having
delivery head from 24 to 13m. and discharge from 400 to 1000
Itrs. per minute (Max efficiency at 21m head & 680 Itr discharge)
& delivery pipe of necessary Page
diameterline erected with necessary H
208 of 259 05/06/18 12:15
Electrical - 2018-2019 - 01/04/2018 -
type clamps as per specification No. WP-OSP
Chapter 12
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
model.)
14058 Chapter 12-5-5 Supplying and erecting fully Automatic star/delta starter suitable 11,338.00 Each
5 for above 15 H.P. upto 25 H.P. squirrel cage motor totally enclosed
with overload and no volt relay complete erected on provided
angle iron frame.(Similar to L & T make ML-1.5 FASD Model)
14058 Chapter 12-5-6 Supplying and erecting fully Automatic star / delta starter suitable 17,881.00 Each
6 for above 25 H. P. to 35 H. P. squirrel cage motor totally enclosed
with overload and no volt relay complete erected on provided
angle iron frame. (similar to L & T make MN 32 FASD model .)
14058 Chapter 12-5-7 Supplying and erecting pump protection relay comprising current 2,513.00 Each
7 sensing phase failure and UV+OV relay with dry run and overload
protection suitable for 3 phase pumps.(Similar to Minilec -D2 MPR
2 model)
14058 Chapter 12-5-8 Supplying and erecting flat flexible 3 core 2.5 sq mm PVC 110.00 Meter
8 sheathed submersible type copper cable suitably clamped at fixed
intervals with column pipe assembly complete.
14058 Chapter 12-5-9 Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed 150.00 Meter
9 submersible type copper cable suitably clamped at fixed intervals
with column pipe assembly complete.
14059 Chapter Supplying and erecting flat flexible 3 core 6 sq mm PVC sheathed 209.00 Meter
0 12-5-10 submersible type copper cable suitably clamped at fixed intervals
with column pipe assembly complete.
14059 Chapter Supplying and erecting flat flexible 3 core 1.5 sq mm PVC 78.00 Meter
1 12-5-11 sheathed submersible type copper cable suitably clamped at fixed
intervals with column pipe assembly complete.
14059 Chapter Supplying & erecting Water level controller 230/415 V AC., Two 1,324.00 Each
2 12-5-12 way for under ground tank operation only.
14059 Chapter Supplying & erecting Water lavel controller 230/ 415V AC., Four 1,374.00 Each
3 12-5-13 way for under ground & Over head tank operation.
14059 Chapter Supplying & erecting PVC coated 5 mm dia Brass Sensor/ electrode 237.00 Each
4 12-5-14 duly wired with nut & bolts complete
14059 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 5,887.00 Each
5 12-5-15 A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of
DOL starter having relay range 9-14 AMP,S.P.P., Combined
ammeter/voltmeter, phase indicating lamp enclosed in CRCA
powder coated Vibration proof encloser with IP 54 protection.
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G6/ CAT NO. SS97756 )
Rate In (Rs)
Item Description Rate Unit
14059 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 5,953.00 Each
6 12-5-16 A.c. Submersible/centrifugal pump set upto 7.5- 10 HP consisting
of DOL starter having relay range 13-21 AMP,S.P.P., Combined
ammeter/voltmeter, phase indicating lamp enclosed in CRCA
powder coated Vibration proof encloser with IP 54 protection.
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G10 / CAT NO.
SS95983 )
14059 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 6,839.00 Each
7 12-5-17 A.c. Submersible/centrifugal pump set upto 7.5- 10 HP consisting
of DOL starter having relay range 28-42 AMP,S.P.P., Combined
ammeter/voltmeter, phase indicating lamp enclosed in CRCA
powder coated Vibration proof encloser with IP 54 protection.
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G10 H / CAT NO.
SS95974 )
14059 Chapter Supplying & erecting automatic control panel for 1 Ph, 230 volt, 4,399.00 Each
8 12-5-18 A.c. Submersible/centrifugal pump set upto 2 HP consisting of DOL
starter Of suitable relay range S.P.P., Combined ammeter/
voltmeter, phase indicating lamp enclosed in CRCA powder coated
Vibration proof encloser with IP 54 protection. Control Panel should
offer single phasing, phase reversal, phase inbalence etc ( Similar
to LT model no.MR G2)
14059 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 11,248.00 Each
9 12-5-19 A.c. Submersible/centrifugal pump set upto 20 HP consisting of
Star Delta starter having relay range 13-21Amp,S.P.P., Combined
ammeter/ voltmeter, phase indicating lamp enclosed in CRCA
powder coated Vibration proof encloser with IP 54 protection.
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G20 / CAT NO. SS
95984 )
14060 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 13,639.00 Each
0 12-5-20 A.c.Submersible/centrifugal pump set upto 20 HP consisting of
Star Delta starter having relay range 28-42 Amp, S.P.P., Combined
ammeter/ voltmeter, phase indicating lamp enclosed in CRCA
powder coated Vibration proof encloser with IP 54 protection.
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G20H / CAT NO. SS
95975 )
14060 Chapter Supplying & erecting automatic control panel for 3 Ph, 415 volt, 22,781.00 Each
1 12-5-21 A.c.Submersible/ centrifugal pump set upto 30 HP consisting of
Star Delta starter having relay range 30-50 Amp, S.P.P., Combined
ammeter/ voltmeter, phase indicating lamp enclosed in CRCA
Electrical - 2018-2019 - 01/04/2018 - Page 211 of 259 05/06/18 12:15
powder coated Vibration proof encloser with IP 54 protection.
Chapter 12
Control Panel should offer single phasing, phase reversal, phase
inbalence etc ( Similar to LT model no.MU G30 / CAT NO. CS
96008 )
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14061 Chapter 12-8-4 Dismantling the existing ejecto pump with GI pipeline upto 10 m 2,133.00 Each
7 depth.
14061 Chapter 12-8-5 Dismantling the existing Submersible pump with PVC pipeline 814.00 Each
8
14061 Chapter 12-8-6 Dismantling the existing submersible pump with GI pipeline upto 2,133.00 Each
9 10m depth. (For additional depth of each 3 m or part thereof add
Rs.50/- per 3 m, in the rates)
14062 Chapter 12-8-7 Attending breakdown of water pump & accossiated ancliries for 814.00 Each
0 fault finding includung minor repairs & put in working condition &
submit the report of inspection to the engineer in-charge.
Specification:
Rate In (Rs)
Item Description Rate Unit
14062 Chapter 13-4-2 Supplying installing, testing, commissioning of Jockey Pump of 1,14,500.00 Each
7 240 LPM at 105 mtr. head 3 ph. 415 A.C., 20 HP (18.5 kW) or of
suitable HP with suitable Stages as per specification No.
FF-MFP/JP
Chapter 13-5 Booster Pump (FF-MFP/BP)
14062 Chapter 13-5-1 Supplying installing, testing, commissioning of Booster Pump of 31,797.00 Each
8 450 LPM at 35 m head single stage (mono block) 3 ph. 415 A.C.
7.5 HP or of suitable HP with suitable Stages as per specification
No. FF-MFP/BP
14062 Chapter 13-5-2 Supplying installing, testing, commissioning of Booster Pump of 38,307.00 Each
9 468 LPM at 40m head, 10 HP or of suitable HP with suitable Stages
as per specification No. FF-MFP/BP
14063 Chapter 13-5-3 Booster Pump of 180 LPM at average 40 m Head, 5 HP or of 23,008.00 Each
0 suitable HP with suitable Stages.
14063 Chapter 13-5-4 Booster Pump of 900 LPM at average 40 m Head, 12.5 HP either 48,256.00 Each
1 Monoblock or of suitable HP with suitable Stages.
Chapter 13-6 Pipes (FF-PP)
14063 Chapter 13-6-1 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 236.00 Meter
2 size 20 mm dia with necessary fittings as per specification No.
FF-PP
14063 Chapter 13-6-2 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 305.00 Meter
3 size 25 mm dia with necessary fittings as per specification no.
FF-PP
14063 Chapter 13-6-3 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 574.00 Meter
4 size 50 mm dia with necessary fittings as per specification No.
FF-PP
14063 Chapter 13-6-4 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 911.00 Meter
5 size 75/80 mm dia with necessary fittings as per specification No.
FF-PP
14063 Chapter 13-6-5 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 1,251.00 Meter
6 size 100 mm dia with necessary fittings as per specification no.
FF-PP
14063 Chapter 13-6-6 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 1,790.00 Meter
7 size 150 mm dia with necessary fittings as per specification no.
FF-PP
14063 Chapter 13-6-7 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of 2,412.00 Meter
8 size 200 mm dia with necessary fittings as per specification no.
FF-PP
Electrical - 2018-2019 - 01/04/2018 - Page 216 of 259 05/06/18 12:15
Chapter 13
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14063 Chapter 13-6-8 Providing coating of Bitumen Paint & 4mm thick Wrapping as per 304.00 Meter
9 IS 10221 for underground 100 mm Ring Main of Fire Fighting
System.
14064 Chapter 13-6-9 Providing coating of Bitumen Paint & 4mm thick Wrapping as per 405.00 Meter
0 IS 10221 for underground 150 mm Ring Main of Fire Fighting
System.
14064 Chapter Providing coating of Bitumen Paint & 4mm thick Wrapping as per 562.00 Meter
1 13-6-10 IS 10221 for underground 200 mm Ring Main of Fire Fighting
System.
Chapter 13-7 Foot Valve (FF-FV)
14064 Chapter 13-7-1 Supplying and installing cast iron foot valve ball type/flap type of 4,007.00 Each
2 size 80 mm dia with strainer for negative suction as per
specification No. FF-VL/FV
14064 Chapter 13-7-2 Supplying and installing cast iron foot valve ball type/flap type of 5,786.00 Each
3 size 100 mm dia with strainer for negative suction as per
specification No. FF-VL/FV
14064 Chapter 13-7-3 Supplying and installing cast iron foot valve ball type/flap type of 14,978.00 Each
4 size150 mm dia with strainer for negative suction as per
specification No. FF-VL/FV
14064 Chapter 13-7-4 Supplying and installing cast iron foot valve ball type/flap type of 25,283.00 Each
5 size200 mm dia with strainer for negative suction as per
specification No. FF-VL/FV
Chapter 13-7-5 End Line Strainer (+ve suction) (ELS)
14064 Chapter Supplying and installing 75/80 mm dia end line strainer for +ve 3,936.00 Each
6 13-7-5-1 suction as per specification No. FF-VL/ELS
14064 Chapter Supplying and installing 100 mm dia end line strainer for +ve 5,474.00 Each
7 13-7-5-2 suction as per specification No. FF-VL/ELS
14064 Chapter Supplying and installing 150 mm dia end line strainer for +ve 8,084.00 Each
8 13-7-5-3 suction as per specification No. FF-VL/ELS
14064 Chapter Supplying and installing 200 mm dia end line strainer for +ve 11,451.00 Each
9 13-7-5-4 suction as per specification No. FF-VL/ELS
Chapter 13-7-6 Sluice Valve
14065 Chapter Supplying and installing cast iron double flange sluice valve 4,684.00 Each
0 13-7-6-1 75/80 mm dia.as per specification No. FF-VL/SV
14065 Chapter Supplying and installing cast iron double flange sluice valve 6,852.00 Each
1 13-7-6-2 100 mm dia. as per specification No. FF-VL/SV
Rate In (Rs)
Item Description Rate Unit
14065 Chapter Supplying and installing cast iron double flange sluice valve 10,562.00 Each
2 13-7-6-3 150 mm dia. as per specification No. FF-VL/SV
14065 Chapter Supplying and installing cast iron double flange sluice valve 18,023.00 Each
3 13-7-6-4 200 mm dia.as per specification No. FF-VL/SV
Chapter 13-7-7 Butterfly Valves BFV)
14065 Chapter Supplying & Installing cast iron double flange butterfly valve of 2,588.00 Each
4 13-7-7-1 size 75/80 mm dia. as per specification No. FF-VL/BFV
14065 Chapter Supplying & Installing cast iron double flange butterfly valve of 3,310.00 Each
5 13-7-7-2 size 100 mm dia. as per specification No. FF-VL/BFV
14065 Chapter Supplying & Installing cast iron double flange butterfly valve of 5,104.00 Each
6 13-7-7-3 size 150 mm dia. as per specification No. FF-VL/BFV
14065 Chapter Supplying & Installing cast iron double flange butterfly valve of 8,182.00 Each
7 13-7-7-4 size 200 mm dia.as per specification No. FF-VL/BFV
Chapter 13-7-8 Non Return Valves (NRV)
14065 Chapter Supplying and installing double flange NRV of size 75/80 mm dia 5,610.00 Each
8 13-7-8-1 as per specification No. FF-VL/NRV
14065 Chapter Supplying and installing double flange ball type NRV of size 75/80 6,332.00 Each
9 13-7-8-2 mm dia as per specification No. FF-VL/NRV
14066 Chapter Supplying and installing double flange NRV of size 100 mm dia as 7,962.00 Each
0 13-7-8-3 per specification No. FF-VL/NRV
14066 Chapter Supplying and installing double flange NRV of size 150 mm dia as 17,396.00 Each
1 13-7-8-4 per specification No. FF-VL/NRV
14066 Chapter Supplying and installing double flange Ball type NRV of size 150 22,547.00 Each
2 13-7-8-5 mm dia as per specification No. FF-VL/NRV
14066 Chapter Supplying and installing double flange NRV of size 200 mm dia as 24,910.00 Each
3 13-7-8-6 per specification No. FF-VL/NRV
14066 Chapter Supplying and installing double flange Ball type NRV of size 200 41,656.00 Each
4 13-7-8-7 mm dia as per specification No. FF-VL/NRV
Chapter 13-7-9 Gate / Wheel Valves (GV)
14066 Chapter Supplying & installing gun metal gate valve of size 20mm dia 828.00 Each
5 13-7-9-1 as per specification No. FF-VL/GV
14066 Chapter Supplying & installing gun metal gate valve of size 25mm dia 1,067.00 Each
6 13-7-9-2 as per specification No. FF-VL/GV
14066 Chapter Supplying & installing gun metal gate valve of size 50mm dia 1,083.00 Each
7 13-7-9-3 as per specification No. FF-VL/GV
Electrical - 2018-2019 - 01/04/2018 - Page 218 of 259 05/06/18 12:15
Chapter 13
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14067 Chapter Supplying G.M. branch pipe of 63 mm Ø fitted with 20 mm Ø 1,583.00 Each
8 13-8-4-1 detachable hexagonal nozzle as per specification No. FF-FFA/NZ
14067 Chapter Supplying Stainless Steel branch Pipe 63 mm Ø fitted with 20 mm 1,613.00 Each
9 13-8-4-2 dia detachable hexagonal nozzle as per specifications No.
FF-FFA/NZ
14068 Chapter Supplying & erecting Gun Metal Chrome plated Nozzle, 19 mm Ø 876.00 Each
0 13-8-4-3 complete as per specification No. FF-FFA/NZ
Chapter 13-8-5 Fire Brigade Connection (FBC)
14068 Chapter Supplying and installing fire brigade Header of 150 mm Ø, for 8,158.00 Each
1 13-8-5-1 supplying water in fire tank as per specification No. FF-FA/FBC
Chapter 13-8-6 Siamese Connection (SMC)
14068 Chapter Supplying and installing fire brigade Header (Siamese Connection) 9,771.00 Each
2 13-8-6-2 of 150 mm Ø for supplying water to wet riser system as per
specification No. FF-FFA/SMC
Chapter 13-8-7 Air Cushion Tank (Air Vessel) (ACT)
14068 Chapter Supplying and installing Air Vessel of 300 mm Ø 1.5m in height 10,266.00 Each
3 13-8-7-1 M.S. tank installed inside pump house as per specification No.
FF-FFA/ACT
Chapter 13-8-8 Air Release Valve (ARV)
14068 Chapter Supplying and erecting 20/25mm Ø G.M.air release cock, with 683.00 Each
4 13-8-8-1 necessary G.I. coupling to be fitted on top of Air vessel or on wet
riser as per specification No. FF-FFA/ARV
Chapter 13-8-9 Pressure Guage (PG)
14068 Chapter Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI 652.00 Each
5 13-8-9-1 or 0-14 kg per cm square fitted with 12/15 mm Ø. pad cock valve,
and G.I. pipe, elbow etc. as per requirement in an approved
manner as per specification No. FF-FFA/PG
Chapter Pressure Switch(PS)
13-8-10
14068 Chapter Supplying and installing DANFOSS make pressure switch with 1,539.00 Each
6 13-8-10-1 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an
approved manner as per specification No. FF-FFA/PS
Chapter Orifice Plate(OP)
13-8-11
14068 Chapter Supplying and erecting one no. Brass orifice plate having 6 mm. 846.00 Each
7 13-8-11-1 thickness, 140 mm outer dia of 140 mm at every single outlet
hydrant valve as per specification No. FF-FFA/OP
Electrical - 2018-2019 - 01/04/2018 - Page 220 of 259 05/06/18 12:15
Chapter 13
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14069 Chapter Supplying, erecting, testing and commissioning Manual Call Point 486.00 Each
7 13-10-1 (Pill box) with break glass push button in metal enclosure complete
as per specification No. FF-FAAS/MCP
14069 Chapter Supply and erecting hooters with CRCA enclosure complete as per 569.00 Each
8 13-10-2 specification No. FF-FAAS/HTR
14069 Chapter Supplying, erecting and testing remote response indicators as 183.00 Each
9 13-10-3 per specification No. FF-FAAS/RRI
14070 Chapter Supplying and erecting XLPE armoured cable 2 core 1.5 92.00 Meter
0 13-10-4 sq.mm. copper conductor complete erected on wall/ ceiling as
per specification No. CB-LT/CU
14070 Chapter Supplying and erecting XLPE armoured cable 4 core 1.5 107.00 Meter
1 13-10-5 sq.mm. copper complete erected on wall/ ceiling as per
specification No. CB-LT/CU
14070 Chapter Supplying and erecting XLPE armoured cable 8 core 1.5 215.00 Meter
2 13-10-6 sq.mm. copper complete erected on wall/ ceiling as per
specification No. CB-LT/CU
14070 Chapter Supplying and erecting XLPE armoured cable 12 core 1.5 295.00 Meter
3 13-10-7 sq.mm. copper complete erected on wall/ ceiling as per
specification No. CB-LT/CU
14070 Chapter Supplying, erecting, testing and commissioning the 2 Zones 15,870.00 Each
4 13-10-8 Microprocessor based conventional Fire Alarm Control Panel (FACP)
with standard accessories complete as per specification No.
FF-FAAS/FACP
14070 Chapter Supplying, erecting, testing and commissioning 2 Zone, local 4,798.00 Each
5 13-10-9 signal control panel (LCP) with standard accessories complete as
per specification No. FF-FAAS/LCP
Chapter 13-11 P A System (FF-PAS)
14070 Chapter Supplying, erecting, testing and commissioning amplifier 120 W 15,526.00 Each
6 13-11-1 for Public address system suitable to operate on 230 Volts A.C. /
12 Volts D.C. supply as per specification No. FF-PA/AFR
14070 Chapter Supplying, erecting, testing and commissioning sound column 2,359.00 Each
7 13-11-2 15 Watts complete as per specification No. FF-PA/SOC
14070 Chapter Supplying, erecting, testing and commissioning microphone as 4,501.00 Each
8 13-11-3 per specification No. FF-PA/MIC
14070 Chapter Supplying & erecting, stand for microphone. (Similar to 1,596.00 Each
9 13-11-4 AHUJA make model DGN)
Rate In (Rs)
Item Description Rate Unit
14071 Chapter Supplying & erecting, Table stand for microphone. (Similar to 1,000.00 Each
0 13-11-5 AHUJA make model DGT)
14071 Chapter Supplying erecting, testing to 2 core shielded Microphone cable as 122.00 Meter
1 13-11-6 per specification No. FF-PA/MCC
Chapter 13-12 Sprinklers (FF-SPR)
14071 Chapter Supplying and erecting 15 mm (½") dia. NBCM Body chrome 381.00 Each
2 13-12-1 finished quartzoid bulb sprinkler having 68º C fixed temperature
rating with deflector disc of conventional construction as per
specification No. FF-SPR
14071 Chapter Supplying & erecting vane type water flow detector suitable for 6,061.00 Each
3 13-12-2 detecting flow of water in wet sprinkler pipe of main line or branch
lines of 75/80 mm dia having following features 1) Visual Switch
Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium
pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure
Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised
Switches 7) Serviceable Without Draining Pipes
14071 Chapter Supplying & erecting vane type water flow detector suitable for 6,923.00 Each
4 13-12-3 detecting flow of water in wet sprinkler pipe of main line or branch
lines of 100 mm dia having following features 1) Visual Switch
Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium
pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure
Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised
Switches 7) Serviceable Without Draining Pipes
Chapter 13-13 FIRE SEALANT SYSTEM (FF-FRM)
14071 Chapter Supplying and erecting Fire resistant Mortar (20 kg) with fire 7,823.00 Per Job
5 13-13-1 resistance class S90 as per National Electrical Code (NEC)
SP30-2011 suitable to seal the openings with all kinds of cables,
pipes and cable support system in steel and aluminium and plastic
profiles ( Except hollow core conductors). The residual openings
shall be closed with filler, as per specification No. FF-FRM
14071 Chapter Supplying & Erecting four wire conventionally single ended 31,452.00 Each
6 13-13-2 reflected type beam smoke detector with 8 “ receiver . The range
of smoke detector is max 164feet.
Chapter 13-14 FIRE SAFETY AUDIT
14071 Chapter Providing/Conducting Complete Fire audit inculding submission of 6.00 Sq.m
7 13-14-1 building wise audit/complaince Report
Specification:
Rate In (Rs)
Item Description Rate Unit
14072 Chapter Temporary illumination consisting of white/colour series lights 50 1,100.00 Per
7 14-1-10 Nos. with miniature lamps of 6.2 to 16V with holders, bulbs, Thousan
mains and Switchgears erected and dismantled with rotor effect as d
approved with scaffolding upto three days
14072 Chapter Temporary illumination consisting of 2000W sungun or colour 398.00 Each
8 14-1-11 tran light fitting complete with stand cutter & strainer alongwith
mains, tube & Switchgears with continuous earth wire erected
& dismantled without scaffolding upto three days.
14072 Chapter Providing & fixing Electronic rotating machine to give running 369.00 Each
9 14-1-12 effect to strips lights & miniature lights upto a load of 5000 W
either mechanical cum electrical or electronics complete with
mains & Switchgears with continuous earth wire and dismantling
upto three days.
14073 Chapter Temporary illumination wrapping of coloured gelatin paper to 6.00 Each
0 14-1-13 36/40 W, fluorescent tube light/500 W flood light fitting complete
with rubber boards and dismantling upto three days.
14073 Chapter Providing oscillating type pedestal air circulators 600/900 mm or 293.00 Each
1 14-1-14 air cooler connected with necessary mains, Switchgears with
continuous earthing maintaining the same during the function
& including dismantling upto three days.
14073 Chapter Providing oscillating type pedestal fan 16" (400 mm) or 140.00 Each
2 14-1-15 ceiling fan connected with necessary mains, Switchgears with
continuous earthing maintaining the same during the function
& including dismantling upto three days.
14073 Chapter Providing evaporator air cooler connected with necessary mains, 347.00 Each
3 14-1-16 Switchgears with continuous earthing maintaining the same
during the function & including dismantling upto three days.
14073 Chapter Providing heavy duty Exhaust fan 18" or 24" connected with 342.00 Each
4 14-1-17 necessary mains, Switchgears with continuous earthing
maintaining the same during the function and including
dismantling for three days.
14073 Chapter Providing temporary plug point with 3 pin 6A/16A with necessary 27.00 Each
5 14-1-18 mains & Switchgears & continuous earth connection upto three
days.
14073 Chapter Providing 1.5 Ton capacity window Air conditioning unit 3,015.00 Each
6 14-1-19 complete with temporary frame and fabrication work and
required material to achieve cooling temperature connected
along with necessary mains, switchgear and continuous earthing
maintaining the same during the function and including
dismantling; for three days.
Electrical - 2018-2019 - 01/04/2018 - Page 225 of 259 05/06/18 12:15
Chapter 14
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14073 Chapter Providing 280 liters capacity Refrigerator complete with M.S. stand 635.00 Each
7 14-1-20 if necessary connected with main switchgear and continuous
earthing maintaining the same during the function and including
dismantling; for three days.
14073 Chapter Providing 120/150 liter capacity water cooler with water filter 1,333.00 Each
8 14-1-21 (Candle type or UV tube) with M.S. stand complete with minor
plumbing work if necessary connected with mains switchgear and
continuous earthing maintaining the same during the function and
including dismantling; for three days.
14073 Chapter Providing 20"/24" colour Television with multi channel tuner, 332.00 Each
9 14-1-22 connected with necessary mains switchgear with continuous
earthing maintaining the same during the function and including
dismantling; for three days.
14074 Chapter Providing 6V/10V with 20/40 Watt fluorescent emergency lamp 136.00 Each
0 14-1-23 connected with necessary mains switchgear and continuous
earthing maintaining the same during the function and including
dismantling; for three days.
14074 Chapter Providing Digital projector with spring loaded white screen 4,647.00 Each
1 14-1-24 connected with necessary mains, switchgear and maintaining
the same during the function including dismantling.
14074 Chapter Temporary illumination consisting of Round LED/ neon flex LED/ 12.00 Meter
2 14-1-25 flexible strip LED having 2 to 5 W capacity per meter and
consisting suitable power adaptor with mains, Switchgears erected
and dismentled without using scaffolding and maintaining the
same upto 3 days
14074 Chapter Temporary illumination consisting of Round LED/ neon flex LED/ 14.00 Meter
3 14-1-26 flexible strip LED having 2 to 5 W capacity per meter and
consisting suitable power adaptor with mains, Switchgears erected
and dismentled with using scaffolding and maintaining the same
upto 3 days
14074 Chapter Providing & maintaining temporary 2 Ton capacity split type Air 5,160.00 Each
4 14-1-27 conditioning unit complete with temporary stand and fabrication
work and required material to achieve cooling temperature
connected along with necessary mains, switchgear and continuous
earthing maintaining the same during the function and including
dismantling. for three day.
14074 Chapter Providing & maintaining temporary 2 Ton capacity window type 3,716.00 Each
5 14-1-28 Air conditioning unit complete with temporary stand and
fabrication work and required material to achieve cooling
temperature connected along with necessary mains, switchgear
and continuous earthing maintaining the same during the function
Electrical - 2018-2019 and
- 01/04/2018 -
including dismantling; Page
for 226day.
three of 259 05/06/18 12:15
Chapter 14
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14075 Chapter Providing & maintaining All in one Desktop PC with following 1,012.00 Each
4 14-1-37 configuration Intel TM second generation core i3 G630, 2GB DDR3
RAM, 1TB HARD DISK, DVDR W optical drive 20'' LED screen, Web
camera, wifi, bluetooth, keyboard & mouse, Media card reader etc
for three day.
14075 Chapter Providing & maintaining Laser Printer, Resolution (in dpi) Mono 290.00 Each
5 14-1-38 600, paper size A4, print speed in PPM (A4 size) 25, Port : 1 USB,
Memory (in MB): NA Network card 10/100:YES, Duplexing: YES
etc on hire basis for three day.
14075 Chapter Providing & maintaining 1 KVA, On line UPS pure sine wave on hire 2,107.00 Each
6 14-1-39 basis suitable for 30 minutes battery backup to provided computer
with necessary interconnecting cabling, wiring etc for three days.
14075 Chapter Providing & maintaining 600 VA Digital Pure Sine wave Invertor 437.00 Each
7 14-1-40 based on IGBT technology on hire basis suitable for 120 minutes
battery backup to electrical installation with necessary
interconnecting cabling, wiring etc for one days.
14075 Chapter Providing & maintaining 1400 VA Digital Pure Sine wave Invertor 767.00 Each
8 14-1-41 based on IGBT technology on hire basis suitable for 120 minutes
battery backup to electrical installation with necessary
interconnecting cabling, wiring etc for one days.
14075 Chapter Providing & maintaining 2500 VA Digital Pure Sine wave Invertor 1,537.00 Each
9 14-1-42 based on IGBT technology on hire basis suitable for 120 minutes
battery backup to electrical installation with necessary
interconnecting cabling, wiring etc for one days.
14076 Chapter Temporary illumination Consisting of LED flood light fitting 100w to 836.00 Each
0 14-1-43 115w Metal Halide Flood light fitting 250watt complete erected
with lamp,holders, mains,switchgears with continuous earth wire
erected & dismentaled without using Scaffolding upto Three days
14076 Chapter Temporary Illumniation Consisting of LED flood light fitting 100w to 848.00 Each
1 14-1-44 115w Metal Halide Flood light fitting 250watt complete erected
with lamp,holders, mains,switchgears with continuous earth wire
erected & dismentaled with using Scaffolding upto Three days
14076 Chapter Providing Temporary Plug point with 3 phase industrial socket 100.00 Each
2 14-1-45 having CRCA sheet metal enclosure with 30A, 3 pin plug & earth
socket and 30A, 3 pin, plug top with 30A, triple pole MCB,
mains,switchgears with continuous earth wire upto three days
14076 Chapter Providing Temporary PVC Armoured Cable 4 core 50 sq mm 19.00 Meter
3 14-1-46 Aluminium conductor with continuous 12 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
Electrical - 2018-2019 - 01/04/2018 - Page 228 of 259 05/06/18 12:15
Chapter 14
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14076 Chapter Providing Temporary PVC Armoured Cable 4 core 95 sq mm 24.00 Meter
4 14-1-47 Aluminium conductor with continuous 10 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
14076 Chapter Providing Temporary PVC Armoured Cable 3.5 core 150 sq mm 37.00 Meter
5 14-1-48 Aluminium conductor with continuous 8 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
14076 Chapter Providing Temporary PVC Armoured Cable 3.5 core 240 sq mm 51.00 Meter
6 14-1-49 Aluminium conductor with continuous 8 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
14076 Chapter Providing Temporary PVC Armoured Cable 3.5 core 300 sq mm 60.00 Meter
7 14-1-50 Aluminium conductor with continuous 8 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
14076 Chapter Providing Temporary PVC Armoured Cable 3.5 core 400 sq mm 65.00 Meter
8 14-1-51 Aluminium conductor with continuous 8 SWG G.I. Earth wire
complete erected with gland and lugs and switchgears upto three
days
14076 Chapter Temporary Illumniation Consisting of water proof LED Par Light, 54 1,064.00 Each
9 14-1-52 pieces with RGBW Controller complete erected with
mains,switchgears with continuous earth wire erected &
dismentaled without using Scaffolding upto Three days
14077 Chapter Temporary Illumniation Consisting of water proof LED Par Light, 54 2,143.00 Each
0 14-1-53 pieces with RGBW Controller complete erected with
mains,switchgears with continuous earth wire erected &
dismentaled with using Scaffolding upto Three days
14077 Chapter Temporary Illumniation Consisting of water proof HMI Par Light, 3,966.00 Each
1 14-1-54 4000 watts complete erected with mains,switchgears with
continuous earth wire erected & dismentaled without using
Scaffolding upto Three days
14077 Chapter Temporary Illumniation Consisting of water proof HMI Par Light, 4,186.00 Each
2 14-1-55 4000 watts complete erected with mains,switchgears with
continuous earth wire erected & dismentaled with using Scaffolding
upto Three days
14077 Chapter Providing, commissioning & maintaining CCTV system with 8 9,875.00 Per Job
3 14-1-56 chanel NVR, IP video/audio input - 1 no, IP based 2.0 MP, Full HD,
IR IP Dome Camra - 2 nos, IP based 2.0 MP, Full HD, IR IP PTZ
camera - 2 nos, 2TB Hard Disk - 2 no, 32'' Full H D professinal
Electrical - 2018-2019 Display - 1 no,- 8 port PoE Page
- 01/04/2018 Switch
229- of
1 no,
259 Power supply unit to 05/06/18 12:15
Chapter 14 camera - 1 no, On Line UPS UPS - 1 no with necessary mains,
switchgears on hire basis for one day
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14080 Chapter 16-2-3 Supplying & arranging burnt cured Bricks properly for various 597.00 Per Job
7 purposes (size 9”x4.25”x3”) at work for 100 Bricks
14080 Chapter 16-2-4 Providing and spreading stone metal 25 mm size for 100 mm 73.00 Sq.m
8 depth above the ground level.
14080 Chapter 16-2-5 Supplying and erecting RCC chamber cover of size 750 mm x 750 2,826.00 Each
9 mm x 50mm thick with lifting arrangement including laying of
angle iron frame of angle size as 50 x 50 x6 mm to be fixed /
embedded on top of chamber
Chapter 16-3 C.C. Foundation
14081 Chapter 16-3-1 Providing cement concrete foundation including excavation for the 1,260.00 Each
0 poles (45 cm x 45 cm x 1.2 m) deep in 1:3:6 cement concrete (20
to 25 mm stone metal) and 45 cm x 45 cm x 45 cm / 45 cm dia. x
45 cm height plinth duly plastered and with necessary curing and
finishing in an approved manner. (for 6 m pole)
14081 Chapter 16-3-2 Providing cement concrete foundation including excavation for the 2,548.00 Each
1 poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x
25 mm stone metal) and 45 cm x 45 cm x 45 cm /45 cm dia. x 45
cm height plinth duly plastered and with necessary curing and
finishing in an approved manner. (for 8.5 to 9 m poles)
14081 Chapter 16-3-3 Providing cement concrete foundation including excavation for the 3,017.00 Each
2 poles 60 cm x 60 cm x deep 1/6 of pole length in 1:3:6 cement
concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45
cm /45 cm dia. x 45 cm. height plinth duly plastered and with
necessary curing and finishing in an approved manner. (for above
9 m poles)
14081 Chapter 16-3-4 Providing Cement concrete foundation for pump in 1:2:4 with 4,860.00 Cu.M
3 required size and length of foundation bolts and nuts (cost with
wooden box is included).
14081 Chapter 16-3-5 Providing Cement Concrete foundation including excavation for 2,413.00 Each
4 stay 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete
(20x25mm stone metal) with necessary curing and finishing in an
approved manner.
14081 Chapter 16-3-6 Providing cement concrete for foundation or for concrete filling in 4,614.00 Cu.M
5 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with
necessary curing for pole muffing or any other purposes.
14081 Chapter 16-3-7 Providing & casting of M- 20 grade reinforced cement concrete 3,983.00 Each
6 (RCC) foundation suitable for 3m to 5m high octagonal / conical
G.I. pole considering the safe soil bearing capacity at site as 10
T/sq m at 1.5 m depth including supply of steel, concrete,
excavation and fixing provided nut bolts with the help of template
Electrical - 2018-2019 as
- 01/04/2018 Page
- an approved
per design in 234 of 259
manner. 05/06/18 12:15
Chapter 16
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
excavation and fixing provided nut bolts with the help of template
as per design in an approved manner.
14081 Chapter 16-3-8 Providing & casting of M- 20 grade reinforced cement concrete 6,544.00 Each
7 (RCC) foundation suitable for 6m to 8m high octagonal /conical
G.I. pole considering the safe soil bearing capacity at site as 10
T/sq m at 1.5 m depth including supply of steel, concrete,
excavation and fixing provided nut bolts with the help of template
as per design in an approved manner.
14081 Chapter 16-3-9 Providing & casting of M- 20 grade reinforced cement concrete 8,581.00 Each
8 (RCC) foundation suitable for 9m & 10m high octagonal /conical
G.I. pole considering the safe soil bearing capacity at site as 10
T/sq m at 1.5 m depth including supply of steel, concrete,
excavation and fixing provided nut bolts with the help of template
as per design in an approved manner.
14081 Chapter Providing & casting of M- 20 grade reinforced cement concrete 11,811.00 Each
9 16-3-10 (RCC) foundation suitable for 11m & 12.5m high octagonal /conical
G.I. pole considering the safe soil bearing capacity at site as 10
T/sq m at 1.5 m depth including supply of steel, concrete,
excavation and fixing provided nut bolts with the help of template
as per design in an approved manner
14082 Chapter Providing & casting M- 20 cement concrete foundation suitable for 35,327.00 Each
0 16-3-11 12.5 m raising lowering high mast considering the safe soil bearing
capacity at site as 10 T/sq m at 2 m depth including excavation
and fixing provided nut bolts with the help of template as per
design in an approved manner.
14082 Chapter Providing & casting M- 20 cement concrete foundation suitable for 44,098.00 Each
1 16-3-12 16 m raising lowering high mast considering the safe soil bearing
capacity at site as 10 T/sq m at 2 m depth including excavation
and fixing provided nut bolts with the help of template as per
design in an approved manner
14082 Chapter Providing & casting M- 20 cement concrete foundation suitable for 55,006.00 Each
2 16-3-13 20 m raising lowering high mast considering the safe soil bearing
capacity at site as 10 T/sq m at 2 m depth including excavation
and fixing provided nut bolts with the help of template as per
design in an approved manner.
14082 Chapter Providing & casting M- 20 cement concrete foundation suitable for 62,966.00 Each
3 16-3-14 25 m high mast considering the safe soil bearing capacity at site
as 10 T/sq m at 2 m depth including excavation and fixing
provided nut bolts with the help of template as per design in an
approved manner.
Chapter 16-4 Painting (CW-PTG)
Electrical - 2018-2019 - 01/04/2018 - Page 235 of 259 05/06/18 12:15
Chapter 16
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14082 Chapter 16-4-1 Scrapping existing paint & Spray painting the table fan / pedestal 114.00 Each
4 fan / cabin fan / ceiling fan / exhaust fan including guards etc As
per specification No. CW-PTG/PTF
14082 Chapter 16-4-2 Scrapping the existing paint and painting of pipe pole upto 6 m 50.00 Meter
5 length along with street light / pole brackets / clamps completely
as per specification No CW -PTG/PTP.
14082 Chapter 16-4-3 Scrapping the existing paint and painting of steel tubular / rail / 68.00 Meter
6 RSJ pole above 6.0 m length along with street light / pole
brackets / clamps completely as per specification No CW -PTG/PTP.
14082 Chapter 16-4-4 Scrapping existing paint & Spray painting of fluorescent fitting with 69.00 Each
7 flat reflector for 1x4' FTL completely. As per specification No.
CWPTG/ PFT
14082 Chapter 16-4-5 Scrapping existing paint & Spray painting of fluorescent fitting with 76.00 Each
8 flat reflector for 2x4' FTL completely. As per specification No.
CWPTG/ PFT
14082 Chapter 16-4-6 Spray Painting of Panel type lift doors of MS complete. As per 749.00 Each
9 specification no. CW-PTG/PLD1
14083 Chapter 16-4-7 Painting lift door of collapsible type complete. As per specification 608.00 Each
0 No. CW-PTG/PLD2
14083 Chapter 16-4-8 Spray painting of distribution transformer upto 200 kVA capacity 2,058.00 Per Job
1 complete. As per specification No. CW-PTG/PDT
14083 Chapter 16-4-9 Spray painting of distribution transformer above 200 kVA capacity 2,843.00 Per Job
2 complete. As per specification No. CW-PTG/PDT
14083 Chapter Painting fencing of transformer sub station including all supports, 93.00 Sq.m
3 16-4-10 iron work and doors from both sides with one coat of red oxide &
two coats of aluminium paint, in an approved manner as per
direction.
14083 Chapter Scrapping existing paint of feeder pillar / switchgears and frame of 208.00 Sq.m
4 16-4-11 panel board completely without damaging and painting the same
with single coat of Red oxide & two coats of approved quality
enamel paint in an approved manner. (The square meter area of
angle iron frame on which the switchgears are erected shall be
considered for measurement purpose)
14083 Chapter Providing powder coating of approved color shade on both sides of 318.00 Sq.m
5 16-4-12 provided iron work / MS / CRCA sheet steel work complete
including anti-rust treatment in an approved manner.
14083 Chapter Providing Epoxy painting on both side of approved color shade of 441.00 Sq.m
6 16-4-13 provided iron work / MS / CRCA sheet steel work complete along
with anti-rust treatment in an approved manner.
Electrical - 2018-2019 - 01/04/2018 - Page 236 of 259 05/06/18 12:15
Chapter 16
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14085 Chapter Supplying and erecting ISI mark G.I. pipe 100 mm dia ‘C” class 1,530.00 Meter
3 16-5-15 position with accessories. As per specification No. CW-PLB/GP
14085 Chapter Supplying and erecting high density polythene pipe ISI mark 32 66.00 Meter
4 16-5-16 mm dia. suitable for pressure of 6 kg/cm2 connected to
Jet/Submersible pump with required material complete.
14085 Chapter Supplying and erecting high density polythene pipe ISI mark 40 100.00 Meter
5 16-5-17 mm dia. suitable for pressure of 6 kg/cm2 connected to
Jet/Submersible pump with required material complete.
14085 Chapter Supplying and erecting high density polythene pipe ISI mark 50 125.00 Meter
6 16-5-18 mm. dia. suitable for pressure of 6 Kg. / Cm2 connected to
Jet/Submersible pump with required material complete.
Chapter 16-6 Plumbing Accessories
14085 Chapter 16-6-1 Supplying and erecting 25mm dia. Gun metal foot valve position 389.00 Each
7 with necessary materials.
14085 Chapter 16-6-2 Supplying and erecting 40mm dia. Gun metal foot valve at position 752.00 Each
8 with necessary materials.
14085 Chapter 16-6-3 Supplying and erecting 50mm dia. Gun metal foot valve at position 982.00 Each
9 with necessary materials.
14086 Chapter 16-6-4 Supplying and erecting 65mm dia. Gun metal foot valve at position 1,808.00 Each
0 with necessary materials.
14086 Chapter 16-6-5 Supplying and erecting 75/80mm dia. Gun metal foot valve at 2,377.00 Each
1 position with necessary materials.
14086 Chapter 16-6-6 Supplying and erecting 100mm dia. Gun metal foot valve at 3,652.00 Each
2 position with necessary materials.
14086 Chapter 16-6-7 Supplying and erecting 25mm dia. cast iron foot valve at position 275.00 Each
3 with necessary materials.
14086 Chapter 16-6-8 Supplying and erecting 40mm dia. cast iron foot valve at position 453.00 Each
4 with necessary materials.
14086 Chapter 16-6-9 Supplying and erecting 50mm dia. cast iron foot valve at position 566.00 Each
5 with necessary materials.
14086 Chapter Supplying and erecting 65mm dia. cast iron foot valve at position 915.00 Each
6 16-6-10 with necessary materials.
14086 Chapter Supplying and erecting 75/80mm dia. cast iron foot valve at 1,341.00 Each
7 16-6-11 position with necessary materials.
14086 Chapter Supplying and erecting 100mm dia. cast iron foot valve at position 2,788.00 Each
8 16-6-12 with necessary materials.
Electrical - 2018-2019 - 01/04/2018 - Page 238 of 259 05/06/18 12:15
Chapter 16
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
14086 Chapter Supplying and erecting 25mm dia. gun metal sluice valve at 783.00 Each
9 16-6-13 position with necessary materials.
14087 Chapter Supplying and erecting 40 mm. dia. gun metal sluice valve at 1,508.00 Each
0 16-6-14 position with necessary materials
14087 Chapter Supplying and erecting 50mm dia. gun metal sluice valve at 2,162.00 Each
1 16-6-15 position with necessary materials.
14087 Chapter Supplying and erecting 65mm dia. gun metal sluice valve at 4,029.00 Each
2 16-6-16 position with necessary materials.
14087 Chapter Supplying and erecting 75/80mm dia. gun metal sluice valve at 5,679.00 Each
3 16-6-17 position with necessary materials.
14087 Chapter Supplying and erecting 100mm dia. gun metal sluice valve at 11,030.00 Each
4 16-6-18 position with necessary materials.
14087 Chapter Supplying and erecting Non return valve 25mm dia in position 496.00 Each
5 16-6-19 made of gun metal
14087 Chapter Supplying and erecting Non return valve 40mm dia in position 943.00 Each
6 16-6-20 made of gun metal.
14087 Chapter Supplying and erecting Non return valve 50mm dia in position 1,378.00 Each
7 16-6-21 made of gun metal.
14087 Chapter Supplying and erecting Non return valve 65mm dia in position 3,114.00 Each
8 16-6-22 made of gun metal.
14087 Chapter Supplying and erecting Non return valve 75/80mm dia in position 4,045.00 Each
9 16-6-23 made of gun metal.
14088 Chapter Supplying and erecting Non return valve 100mm dia in position 7,610.00 Each
0 16-6-24 made of gun metal.
14088 Chapter Supplying and erecting C.I. flange 25mm dia with necessary nuts 141.00 Each
1 16-6-25 bolts and washers with rubber seal in position.
14088 Chapter Supplying and erecting C.I. flange 40mm dia with necessary nuts 150.00 Each
2 16-6-26 bolts and washers with rubber seal in position.
14088 Chapter Supplying and erecting C.I. flange 50mm.dia with necessary nuts 179.00 Each
3 16-6-27 bolts and washers with rubber seal in position.
14088 Chapter Supplying and erecting C.I. flange 65mm. dia with necessary nuts 226.00 Each
4 16-6-28 bolts and washers with rubber seal in position.
14088 Chapter Supplying and erecting C.I. flange 75/80mm. dia with necessary 384.00 Each
5 16-6-29 nuts bolts and washers with rubber seal in position.
Rate In (Rs)
Item Description Rate Unit
14088 Chapter Supplying and erecting C.I. flange 100mm. dia with necessary nuts 403.00 Each
6 16-6-30 bolts and washers with rubber seal in position.
14088 Chapter Supplying and erecting 0-100 lb/sq. inch pressure gauge having 4" 666.00 Each
7 16-6-31 dia complete with socket for 1/2" G.I. pipe.
14088 Chapter Supplying and erecting 40mm dia. ball type foot valve having C.I. 1,103.00 Each
8 16-6-32 body lined from inside with FRP and synthetic rubber coated
reinforced) /Nitrile Rubber ball, leaded fin bronze (IS:318) FRP
sheet, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer
Complete
14088 Chapter Supplying and erecting 50mm dia. ball type foot valve having C.I. 1,564.00 Each
9 16-6-33 body lined from inside with FRP and synthetic rubber coated
(reinforced)/Nitrile Rubber ball, leaded fin bronze (IS:318) FRP
sheet, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer
Complete
14089 Chapter Supplying and erecting 65mm dia. ball type foot valve having C.I. 2,262.00 Each
0 16-6-34 body lined from inside with FRP and synthetic rubber coated
(reinforced)/ Nitrile Rubber ball, leaded fin bronze (IS:318) FRP
sheet, carbon steel (IS:1363 class 4) fastners, C.I./M.S.Stainer
Complete
Specification:
Rate In (Rs)
Item Description Rate Unit
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14089 Chapter 17-1-9 Rewinding of electric motor upto 2 H.P. three phase upto 1400 1,652.00 Each
9 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 3 H.P. three phase upto 1400 2,013.00 Each
0 17-1-10 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 5 H.P. three phase upto 1400 3,022.00 Each
1 17-1-11 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 7.5 H.P. three phase upto 1400 3,659.00 Each
2 17-1-12 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 10 H.P.three phase upto 1400 4,114.00 Each
3 17-1-13 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 12.5 H.P. three phase upto 1400 4,514.00 Each
4 17-1-14 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 15 H.P. three phase upto 1400 5,276.00 Each
5 17-1-15 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
consumption with guarantee for one year
14090 Chapter Rewinding of electric motor upto 20 H.P. three phase upto 1400 6,380.00 Each
6 17-1-16 RPM of all types and makes with copper wire, overhauling with
minor repairs, lubricating of ball bearings & bush bearing, and
replacing screws etc. testing for the original speed and no load
Electrical - 2018-2019 consumption
- 01/04/2018with
- guaranteePagefor one
242year
of 259 05/06/18 12:15
Chapter 17
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
Rate In (Rs)
Item Description Rate Unit
14091 Chapter 17-2-7 Replacing the existing Bush/ rubber, ring, washers of table/ cabin/ 87.00 Each
7 pedestal/ ceiling/ exhaust fan complete with alignment of shaft &
tested.
14091 Chapter 17-2-8 Replacing the existing bearing of approved make for electric motor 2,095.00 Each
8 of 25 H.P. of all types with due alignment of the shaft and tested.
14091 Chapter 17-2-9 Replacing the existing bearing of approved make for electric motor 2,255.00 Each
9 of 30 H.P. of all types with due alignment of the shaft and tested.
Chapter 17-3 Accessories
14092 Chapter 17-3-1 Filtration of Transformer oil on site till satisfactory test results. 22.00 litre
0
14092 Chapter 17-3-2 Supplying and topping up filtered transformer oil of approved 132.00 litre
1 make with test certificate.
14092 Chapter 17-3-3 Supplying and erecting No-Volt-Coil similar to L&T make for 236.00 Each
2 motor having DOL starters of MK-1 Type upto 7.5 H.P.
14092 Chapter 17-3-4 Supplying and erecting No-Volt-Coil similar to L&T make for 463.00 Each
3 motor having DOL starters of MU-1 Type from 7.5 H.P. to 10 H.P.
14092 Chapter 17-3-5 Supplying and erecting No-Volt-Coil similar to L&T make for motor 446.00 Each
4 having Star-Delta Starter of type MK-1/MU for 12.5 H.P. to 15 H.P.
motor.
14092 Chapter 17-3-6 Supplying and erecting No-Volt-Coil similar to L&T make for motor 565.00 Each
5 having Star-Delta Starter of type ML-1.5 for 15 H.P. to 25 H.P.
motor.
14092 Chapter 17-3-7 Supplying and erecting No-Volt-Coil similar to L&T make for motor 463.00 Each
6 having Star-Delta Starter of type MU for 20 H.P. to 30 H.P. motor.
14092 Chapter 17-3-8 Supplying and erecting No-Volt-Coil similar to L&T make for motor 899.00 Each
7 having Star-Delta Starter of type ML-2 for 25 H.P. to 35 H.P. motor.
14092 Chapter 17-3-9 Supplying and erecting No-Volt-Coil similar to L&T make of type 1,215.00 Each
8 MNX for 30 H.P.to 90 H.P.motor
14092 Chapter Supplying and erecting No-Volt-Coil similar to L&T make of type 2,045.00 Each
9 17-3-10 MNX for 90 H.P. to 125 H.P. motor
14093 Chapter Supplying and erecting thermal Overload Relay similar to L&T 1,184.00 Each
0 17-3-11 make for MU motor starter suitable for up to 12.5 HP
14093 Chapter Supplying and erecting thermal Overload Relay similar to L&T 765.00 Each
1 17-3-12 make for MK 1 motor starter suitable for up to 15 HP
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 1,003.00 Each
2 17-3-13 make MN-2 for motor starter 10 H.P. to 17.5 H.P.
Rate In (Rs)
Item Description Rate Unit
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 1,148.00 Each
3 17-3-14 make MN-2 for motor starter 20 H.P. to 25 H.P.
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 1,614.00 Each
4 17-3-15 make MN2 for motor starter 30 H.P to 35 H.P.
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 2,092.00 Each
5 17-3-16 make MN-5 for motor starter 40 H.P. to 50 H.P.
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 2,729.00 Each
6 17-3-17 make MN-5 for motor starter 60 H.P. to 90 H.P.
14093 Chapter Supplying and erecting thermal over load relay similar to L&T 3,124.00 Each
7 17-3-18 make MN-5 for motor starter from 100 H.P. to 125 H.P.
14093 Chapter Supplying & erecting similar to L&T make timer for MK-1 (For 561.00 Each
8 17-3-19 STAR/DELTA) motor starter upto 12.5 H.P.
14093 Chapter Supplying & erecting L&T make Timer with Combination Coil for 1,705.00 Each
9 17-3-20 ML-2 motor starter suitable from 15 H.P to 30 H.P.
14094 Chapter Supplying & erecting Electronic timer ST 100 similar to L&T make 1,165.00 Each
0 17-3-21 above 30 H.P.
14094 Chapter Supplying & erecting contactor MK-1 similar to L&T make for DOL 962.00 Each
1 17-3-22 motor starter from 7.5 H.P. to 10 H.P.
14094 Chapter Supplying & erecting contactor MU-1 similar to L&T make for DOL 1,461.00 Each
2 17-3-23 motor starter from 7.5 H.P. to 10 H.P.
14094 Chapter Supplying & erecting contactor MU-1H similar to L&T make for 1,588.00 Each
3 17-3-24 DOL motor starter from 7.5 H.P. to 10 H.P.
14094 Chapter Supplying & erecting contactor similar to L&T make for MK-2 Star 971.00 Each
4 17-3-25 Delts motor starter from 12.5 H.P. to 15 H.P.
14094 Chapter Supplying & erecting contactor similar to L&T make MU-2 Type for 1,950.00 Each
5 17-3-26 motor starter suitable from 12.5 H.P to 20 H.P.
14094 Chapter Supplying & erecting contactor similar to L&T make for ML-1.5 2,117.00 Each
6 17-3-27 Star Delts motor starter from 15 H.P. to 25 H.P.
14094 Chapter Supplying & erecting contactor similar to L&T make for ML-2 Star 3,839.00 Each
7 17-3-28 Delts motor starter from 25 H.P. to 30 H.P.
14094 Chapter Supplying and erecting contactor similar to L&T make MU-3 Type 2,330.00 Each
8 17-3-29 for motor starter suitable from 25 H.P. to 30 H.P.
14094 Chapter Supplying and erecting contactor similar to L&T make MNX series 5,352.00 Each
9 17-3-30 for motor starter suitable for above 30 H.P. to 40 H.P.
Rate In (Rs)
Item Description Rate Unit
14095 Chapter Supplying and erecting contactor similar to L&T make MNX series 7,044.00 Each
0 17-3-31 for motor starter suitable for above 45 H.P. to 50 H.P.
14095 Chapter Supplying and erecting contactor similar to L&T make MNX series 8,854.00 Each
1 17-3-32 for motor starter suitable from 55 HP to 60 HP.
14095 Chapter Supplying and erecting contactor similar to L&T make MNX series 14,049.00 Each
2 17-3-33 for motor starter suitable for 75 H.P. to 90 H.P.
14095 Chapter Supplying and erecting contactor similar to L&T make MNX series 18,593.00 Each
3 17-3-34 for motor starter suitable for 100 H.P. to 125 H.P.
14095 Chapter Dismantling the existing ceiling fan of various sizes and replacing 128.00 Each
4 17-3-35 the bolt and nuts at reel insulator and at bottom of the down rod
with half threaded bolt of 3/8” dia 2-1/2” to 3-1/2” long and 5/16”
dia 1-3/4” to 2-1/4” long respectively required sizes with 2 plate
washers with oiling, greasing and painting the date of repair and
re-erecting at position.
14095 Chapter Replacing suitable capacity motor of water pump of air cooler of 487.00 Each
5 17-3-36 any capacity and type in lieu of old one.
14095 Chapter Checking the existing Indoor faulty fitting, finding the fault, 39.00 Each
6 17-3-37 repairing by provided necessary material, if any, and putting into
beneficial use with necessary Tools & Tackles.
14095 Chapter Checking the existing outdoor faulty fitting, finding the fault, 77.00 Each
7 17-3-38 repairing by provided necessary material, if any, and putting into
beneficial use with necessary Tools & Tackles.
Specification:
Rate In (Rs)
Item Description Rate Unit
14101 Chapter All types of accessories such as Tube starter / Bell / Holder/ Ceiling 15.00 kg
9 18-1-17 Rose / MCB etc.
14102 Chapter All types of Chokes / condenser / small coils / motor starter etc. 33.00 kg
0 18-1-18
14102 Chapter Lift Ropes / Belt types / Appliances & equipments 17.00 kg
1 18-1-19
14102 Chapter All types of Hot water Boilers 283.00 Each
2 18-1-20
14102 Chapter All types of Electric motor 367.00 HP
3 18-1-21
14102 Chapter All types of Water pump set. 383.00 HP
4 18-1-22
14102 Chapter All types of A.C compressor 450.00 TR
5 18-1-23
14102 Chapter All types of A.C. unit.(Window) 1,700.00 TR
6 18-1-24
14102 Chapter All types of A.C. unit.(Split) 1,733.00 TR
7 18-1-25
14102 Chapter All types of Indoor unit of split A.C. 600.00 Each
8 18-1-26
14102 Chapter Copper piping of A.C. 257.00 kg
9 18-1-27
14103 Chapter Water cooler instant type 617.00 Each
0 18-1-28
14103 Chapter Water cooler storage type 27.00 litre
1 18-1-29
14103 Chapter Refrigerator up to 165 ltr. 633.00 Each
2 18-1-30
14103 Chapter Refrigerator above 165 ltr. 1,067.00 Each
3 18-1-31
14103 Chapter Exhaust fan 9" sweep. 98.00 Each
4 18-1-32
14103 Chapter Exhaust fan 12" sweep 145.00 Each
5 18-1-33
Rate In (Rs)
Item Description Rate Unit
Chapter 19-1 Supply of traffic signal pole assembly complete with 100mm inner
dia. G.I. Pipe (B'class ) including providing M.S. base plate of size
200 mm x200mm x 10 mm thick welded with bottom of the pole
flanged FRP cap at top the pole painted with 2 coat
14107 Chapter 19-1-1 6.00 m long pole 5,500.00 Per No
5
14107 Chapter 19-1-2 9 m long candilever pole (Including parabolic arm 5 m long) 12,000.00 Per No
6
14107 Chapter 19-1-3 11 m long candilever pole (Including "L" type arm 3 m long) 14,000.00 Per No
7
Chapter 19-2 Supply of 300mm dia. Polycarbonate lamp head assembly unit
completely transperent polycarbonate lense & HDPE visor to avoid
sunphantum effect
14107 Chapter 19-2-1 Polycarbonate lamp head Housing 2,000.00 Per No
8
14107 Chapter 19-2-2 Retrofit Red LED (Vehicular ) light output 265 cd & power 10w. 3,000.00 Per No
9
14108 Chapter 19-2-3 Retrofit Amber LED (Vehicular ) light output 385 cd & power 10w. 3,000.00 Per No
0
14108 Chapter 19-2-4 Retrofit Green LED (Vehicular ) light output 105 cd & power 4w. 3,500.00 Per No
1
14108 Chapter 19-2-5 Retrofit Red LED (Pedstrian ) light output 105 cd & power 4w 3,000.00 Per No
2
14108 Chapter 19-2-6 Retrofit Green LED (Pedstrian ) light output 105 cd & power 4w 3,400.00 Per No
3
14108 Chapter 19-2-7 Retrofit Red / Green / Amber ( BRT LETTERS) light output 105 cd & 3,400.00 Per No
4 power 4w
14108 Chapter 19-3 Supply of advanced 32 bit microprocessor GPS based 60,000.00 Per No
5 RF-WIRELESS automatic traffic signal controller housed in M.S.
SWG fribrication wether proof, vandel proof, dust and splash proof
M.steel 16 gauge cabinatepassivated and painted with appropriate
colour, separate access for police control incoporating for special
features 16 signal groups and capable to directly communicate
with higher form of traffic control systems such as cordinated with
adjacent controller with interface to INTERNET via GPRS for
REMOTE MONITORING & CONTROL through web interface.
Rate In (Rs)
Item Description Rate Unit
14108 Chapter 19-4 Supply of ATCS controller compatiable with CDAC Technology with 1,25,000.00 Per No
6 GPS , Key board , CPU card and power supply , vehicle acctuated ,
microprocessor & GPS based automatic traffic signals controller
including providing and fixing of cabinejunction box for power
supply termination and other accessories like 1 no. of cabinet ,
power supply LCD display , key board , CPU card , DO card , Di
card , 12 channel , inductive loop detector , router , ethernet
convertor , 8 port switch , lamp card driver ( AC or DC ) , detector
interface card , earth connection to electrode earth station etc. As
per specification with the Un inturptable power back up for 2 hours
for total junction traffic signal system
14108 Chapter 19-5 Installing the controller on C.C. 1:2:4 pedestial, 60 cm above G.L. 5,000.00 Per No
7 of suitable size, testing & commissioning with any number of
phases including providing earth station as per I.S. rules etc.
complete - 32 bit microprocessor controller
14108 Chapter 19-6 Installing the controller on C.C. 1:2:4 pedestial, 60 cm above G.L. 6,500.00 Per No
8 of suitable size, testing & commissioning with any number of
phases including providing earth station as per I.S. rules etc.
complete - ATCS controller
14108 Chapter 19-7 Supply of microprocessor based node controller to be installed on 7,000.00 Per No
9 each pole housed in MS SWG fabrication weather proof, vadal
proof , dust & splash proof M. Steel 16 gauge cabinet
passivated & painted with appropriate colour, with solid state
output
14109 Chapter 19-8 Providing & Fixing junction box on street light pole for cable 900.00 Per No
0 connection including looping, taking cable through G.I. Pipe upto
junction box from ground level etc. complete A) M S Junction Box
14109 Chapter 19-9 Providing & fixing M.S. 16 Gauge junction box with removable base 6,000.00 Per No
1 plate with wooden plank inside for single /3 phase M.S.E.B. service
connection with main swithes distribution board indicators with
necessary fixing accessories including providing proper earthing
14109 Chapter 19-10 Providing & fixing M.S. 16 Gauge junction box with removable base 3,000.00 Per No
2 plate with wooden plank inside for single /3 phase M.S.E.B. service
connection with main swithes distribution board indicators with
necessary fixing accessories including providing proper earthing
with M.S.E.B. meter
14109 Chapter 19-11 Erection of traffic signal pole in 60 cm x 60 cm x 1.20 m deep pit 3,000.00 Per No
3 with 1:1:5:3 cement, concrete & providing coping jof 30 cm. dia in
C.C., plastering, finishing, curing. (Normal Pole)
Rate In (Rs)
Item Description Rate Unit
14109 Chapter 19-12 Erection of traffic signal pole in 60 cm x 60 cm x 1.20 m deep pit 4,000.00 Per No
4 with 1:1:5:3 cement, concrete & providing coping jof 30 cm. dia in
C.C., plastering, finishing, curing. (Cantiliver Pole)
14109 Chapter 19-13 Local earthing of signal/ street light pole when used as traffic 350.00 Per No
5 signal pole with 10 m length of 10 swg G.I. wire loop being kept at
minimum of 2 m belowG.L. etc. complete as per IS rules.
Chapter 19-14 Painting of signal pole with 2 coats of synthetic enamel paint of
approved colour.
14109 Chapter Painting of Normal pole 300.00 Per No
6 19-14-1
14109 Chapter Painting of cantilever pole-9mtr long 1,000.00 Per No
7 19-14-2
14109 Chapter Painting of cantilever pole-11mtr long 1,300.00 Per No
8 19-14-3
14109 Chapter 19-15 Supply & Installation, commissioning 2 ½ digit signal balance time 8,000.00 Per No
9 indicator / countdown times with red – amber and green phase
timing in seconds with super bright having red and green LED’s
(total 480 Nos.) to show respective colour displays according to
red/Green time interval in process with font size of minimum 115 x
260 mm height alternate “STOP” alphabetical message and
numeric message of count in red interval and ‘GO’ alphabetical
message and numerical count alternate in green colour in green
interval and dash in message in amber interval having 250 CD
luminous output with clear transparent acrylic in front side of MS
18 SWG box size 24” x 18” along with suitable length sun visor
also water and dust, weather proof (IP 65) etc. complete interface
with any make traffic signal controller, with 5cx0.5mm2 wiring up
to Junction box the countdown timer has to work on 3 lamp cores
only and no separate core will be provided for giving supply to
countdown timer. It shall compile with suitable hardware &
Software.
14110 Chapter 19-16 Mounting of single Lampheads of any type 150.00 Per No
0
14110 Chapter 19-17 supply of Blinker controlkler all solid state complete with metalic 2,000.00 Per No
1 box water proof & dust proof painted with synthetic enamel paint
of approved colour, self locking & outer locking arrangement with
lock & keys in duplicate having frquency contro
14110 Chapter 19-18 Installing testing & commisioning of the above 1,500.00 Per No
2
Rate In (Rs)
Item Description Rate Unit
Chapter 19-19 Supply of low maintenance tabular patery EXIDE make wirh
necessary connectors, links terminals etc. as per IS 1651:1991.
14110 Chapter 12 volts DC 66 AH 7,000.00 Per No
3 19-19-1
Chapter 19-20 Supply of photo voltaic solar panels of
14110 Chapter 12 Volts DC 50 W 6,000.00 Per No
4 19-20-1
14110 Chapter 12 Volts DC 70 W 8,000.00 Per No
5 19-20-2
14110 Chapter 19-21 Battery charger charging unit with Battery overcharge 2,000.00 Per No
6 protection,battery deep discharge protection, reverse polarity
protection, charging on (Green) & battery 10W (Red) indication,
reverse current protection and it should be able to handle 5 Amp
of curre
14110 Chapter 19-22 Supply and erection at site of ATS,elevated slanting structure for 1,500.00 Per No
7 mounting frame should be of M.S angles of size 30 mm X 30 mm X
5 mm
14110 Chapter 19-23 Supply & Fixing of jointing kit 1,500.00 Per No
8
14110 Chapter 19-24 Removal of 6 mtr.signal pole with foundation 1,500.00 Per No
9
14111 Chapter 19-25 Removal of Cantilever Pole with foundation 1,500.00 Per No
0
14111 Chapter 19-26 Removal of Lamphead for normal pole 1) Singal Aspect 150.00 Per No
1
14111 Chapter 19-27 Removal o LH for Cantilever pole 1) Single Aspect 150.00 Per No
2
14111 Chapter 19-28 Removal of old cable safety 3,4,6 & 14 Core 150.00 Per No
3
14111 Chapter 19-29 Plastic unbrekable polycarbonate signal lens any colour for 300 350.00 Per No
4 mm dia lamphead
14111 Chapter 19-30 M.S.Box for controller 2,500.00 Per No
5
14111 Chapter 19-31 Shed for main controller 1,500.00 Per No
6
14111 Chapter 19-32 Door for main controller 2,000.00 Per No
7
Electrical - 2018-2019 - 01/04/2018 - Page 253 of 259 05/06/18 12:15
Chapter 19
Rate Card PMC Effective Date 01/04/2018
Rate In (Rs)
Item Description Rate Unit
7
14111 Chapter 19-33 Rewiring of controller 4,000.00 Per No
8
14111 Chapter 19-34 Providing & fixing or replace CPU /Mother board card for 8,000.00 Per No
9 microprocessor controller
14112 Chapter 19-35 Providing & fixing or replace LDS/Driver/RTC card for 6,500.00 Per No
0 microprocessor controller
14112 Chapter 19-36 Providing & fixing or replace Power supply unit / SMPS Card for 2,500.00 Per No
1 microprocessor controller
14112 Chapter 19-37 Providing & fixing or replace Glass fuse 3A / 4A 100.00 Per No
2
14112 Chapter 19-38 Controller lock 250.00 Per No
3
14112 Chapter 19-39 30 A main switch with indication lamp with anchor make 400.00 Per No
4
14112 Chapter 19-40 Replace hood for 300 mm dia size polycarbonate make lamphead 350.00 Per No
5
14112 Chapter 19-41 Pole clamp with hardware 250.00 Per No
6
14112 Chapter 19-42 Annual maintenance of signals with programming ,spare parts for 1,800.00 per
7 controller, coordination with police, MSEB, digging permission month
authority (without necessary deposits )
14112 Chapter 19-43 Providing & operating 4 wheeler including GPS tracking, fuel, 75,000.00 per
8 driving arrangement & maintenance for 4 wheeler ( Maurti ECHO month
or equivalent ) with wooden ladder & necessary safety devices
tools, helmets & trackels with one engineer , one technician, 2
helpers with necessary licenses ( if required ) & electronics tools
such as multimeter, meger, solidering iron, hand tools etc.
14112 Chapter 19-44 Providing & operating 4 wheeler including GPS tracking, fuel, 30,000.00 per
9 driving arrangement & maintenance for 4 wheeler (Maurti Ertiga or month
equivalent) for PMC staff movement
14113 Chapter 19-45 supply and laying of multicore aFlexible copper conductor, PVC 39.00 Meter
0 insulated and sheathed, ISI wire of 0.5 sq mm A) 3core wire
Make: Polycab, Finolex, Diamond and Havells
14113 Chapter 19-46 supply and laying of multicore aFlexible copper conductor, PVC 80.00 Meter
1 insulated and sheathed, ISI wire of 0.5 sq mm A) 6 core wire
Make: Polycab, Finolex, Diamond and Havells
Rate In (Rs)
Item Description Rate Unit
14113 Chapter 19-47 supply and laying of multicore aFlexible copper conductor, PVC 130.00 Meter
2 insulated and sheathed, ISI wire of 0.5 sq mm A) 14 core wire
Make: Polycab, Finolex, Diamond and Havells
Chapter 19-48 supplying and laying of multicore armoured solid core copper
conductor, PVC insulated & sheated, cable of 1.5 sq.mm - ISI mark
14113 Chapter 4 Core 90.00 Rmt
3 19-48-1
14113 Chapter 7 Core 150.00 Rmt
4 19-48-2
14113 Chapter 14 Core 225.00 Rmt
5 19-48-3
Chapter 19-49 supplying and laying of multicore unarmoured flexible copper
conductor, PVC insulated & sheated, cable of 1.5 sq.mm for
overhead
14113 Chapter 4 Core 38.00 Rmt
6 19-49-1
14113 Chapter 7 Core 75.00 Rmt
7 19-49-2
14113 Chapter 14 Core 90.00 Rmt
8 19-49-3
14113 Chapter 19-50 Supply & Installation of 32-bit advance microprocessor controller 35,000.00 Per No
9 with GPS and GPRS facility to connect with web server for
monitoring signals remotely for access by police and municipal
staff by retrofitting arrangement of existing signal controller,
testing, commission all complete with web connectivity including
daily reports generation with 3 years’ warranty on any
manufacturing defects including capital sim card monthly charges
of one year housed in IP 65 protected engineering plastic
enclosures and hand held remote controller for putting signal on
manual mode for policeman.
Specification:
14115 Chapter 21-1 Pole numbering - Pole identifying and numbering with stainless 150.00 Per No
4 steel tag plate embossed. Characters of 4 mm font size embossed
with computerized embossing machine and fixing with bright
annealed stainless clamp, tightened with machine and ear lock
buckle. Material - Stainless steel tag plate SS 304 and bright
annealed stainless clamp SS 304 Plate Size - Length 90mm +/-
5%, width - 19 mm+/- 5%, thickness 0.38 mm Clamp size -
Length as per requirement, width 9mm +/-:5%. Thickness 10 .38
mm. Above job included survey of poles and preparing report
Specification:
14527 Chapter 23-1 Street Light fitting repair - A Testing of street light fitting, 150.00 per no
8 replacement of faulty accessories, doing fitting connections as
before and testing and starting of fitting of fitting. Spares will be
provided by PMC or removing of street light fitting safely &
handling over all the accessories to PMC.
14527 Chapter 23-2 Transporting pole from one place to other as per instructions. 150.00 per no
9
14528 Chapter 23-3 Disconnecting cable / service wore, removing of junction box and 225.00 per no
0 fitting with bracket safely on ground. Cutting of pole from base
with the help of gas cutter – 2A, Cleaning of Site.
14528 Chapter 23-4 For 7m / 8m Pole: - Disconnecting cable / service wore, removing 375.00 per no
1 of junction box and fitting with bracket safely on ground and
removal of pole.
14528 Chapter 23-5 For 9m / 10m Pole: - Disconnecting cable / service wore, removing 450.00 per no
2 of junction box and fitting with bracket safely on ground and
removal of pole.
14528 Chapter 23-6 Pole Painting (6m/ 7m / 8m Pole): - Painting of pole, bracket, pole 113.00 per no
3 cap, clamps etc. with two layers of red oxide & silver aluminium
paint. Painting of bracket before fixing on pole & giving pole
number as per instructions of Officer.
14528 Chapter 23-7 Pole Erection & Concreting: - For 6m / 7m pole excavation in soft 1,125.00 per no
4 soil & murum of size 60 cm x 60cm x 1.25m (In this doing
foundation using 0.5 Cum mixture of cement, sand & Metal in
1:3:6 proportion etc. complete. Doing excavation using
compressor if required & Cleaning of site.
Specification: