0% found this document useful (0 votes)
787 views

Cross Drain Drawing

The document provides notes and details for a structural design drawing for a cross drainage project. It includes notes on dimensions, design principles, soil bearing capacity, scale, reinforcement steel specifications, concrete cover, development lengths, waterproofing, admixtures, and lapping of reinforcement bars. The contractor is responsible for adhering to the drawings on site.

Uploaded by

Manoj Batra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
787 views

Cross Drain Drawing

The document provides notes and details for a structural design drawing for a cross drainage project. It includes notes on dimensions, design principles, soil bearing capacity, scale, reinforcement steel specifications, concrete cover, development lengths, waterproofing, admixtures, and lapping of reinforcement bars. The contractor is responsible for adhering to the drawings on site.

Uploaded by

Manoj Batra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE NOTED.


2. THIS STRUCTURAL DESIGN AND DRAWINGS HAS BEEN PREPARED ON
THE BASIS OF ACCEPTED ANALYSIS AND DESIGN PRINCIIPLES OF I.S.
CODES. THE RESPONSIBILITY OF ADHERING TO DRAWING ON SITE WILL
WILL BE OF CONTRACTOR.
3. SBC IS 10 T / SQ. M. THE SAME IS TO BE VERIFIED / ASCERTAINED BY SOIL
INVESTIGATION AGENCY PRIOR TO FOUNDATION CONCRETE WORKS.
4. DO NOT SCALE THE DRAWING, ONLY WRITTEN DIMENSIONS ARE TO BE
FOLLOWED.

300
REINFORCING STEEL:
UNLESS NOTED OTHERWISE ALL REINFORCEMENT SHALL BE OF T.M.T OF GRADE
Fe500 CONFIRMING TO INDIAN STANDARD.
ALL REINFORCING STEEL SHALL BE OF TESTED QUALITY.
1000
UNLESS NOTED OTHERWISE CLEAR COVER TO NOMINAL COVER TO MAIN
REINFORCEMENT SHALL BE 25MM.
DEVELOPMENT LENGTH IN TENSION : 67D (M20 GRADE CONCRETE, STEEL FE500)
DEVELOPMENT LENGTH IN COMPRESSION: 56D (M20 GRADE CONCRETE, STEEL FE500)

300
WATERPROOF PAINT SHALL BE PROVIDED TO WALLS AND RAFT OF DRAINS.

100
ADMIXTURE KP 200 (@2KG/CUM) TO BE MIXED WITH CONCRETE FOR UG SEPTIC AND
WATER TANKS.
CONSTRUCTION DETAILS
300 300
NOT MORE THAN 50% OF BARS SHALL BE ULAPPED AT ANY SECTION LAP LENGTH

1200

1600
PROJECT: XXXX CONTRACTOR : xxx xxx xxx xxx
XXXX
7, Narayan Niwas, 2nd Khetwadi Lane, Mumbai - 400 004 DRG. TITLE : CROSS DRAINAGE DETAILS
e: [email protected] , t: 022 23861906 CLIENT: MUNICIPAL CORPORATION OF GREATER
DRG. NO. S-01
MUMBAI (MCGM) JOB NO. DRAWN: CH REV . NO. : R0 DATE: 13-11-2019