0% found this document useful (0 votes)
2K views

Battery Discharge Test Procedure

This document describes a battery discharge test procedure. It involves connecting a battery to an 8 ohm resistor and measuring the voltage every 15 minutes until it drops below 5.8V. For one battery, this took 250 minutes. A graph shows the connected and disconnected voltage over time declined steadily for both batteries tested. The results passed the test requirements.

Uploaded by

yasir javed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views

Battery Discharge Test Procedure

This document describes a battery discharge test procedure. It involves connecting a battery to an 8 ohm resistor and measuring the voltage every 15 minutes until it drops below 5.8V. For one battery, this took 250 minutes. A graph shows the connected and disconnected voltage over time declined steadily for both batteries tested. The results passed the test requirements.

Uploaded by

yasir javed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

P12441: Thermoelectric Stove for Haiti 1

Battery Discharge Test Procedure

1. Test Name: Battery Discharging


Test Author: Andrew and Xiaolong
Battery is connected to a decade resistor box, the resistance is set to 8 ohms (6.5V and 750mA)
to simulate the current draw, voltage across the terminal of the battery is measured every 15
minutes with the resistor box is connected. The results are collected and a scatter graph can be
created to show the relationship of battery discharging. Then high voltage and low voltage
disconnected voltages can be determined based on the resulting curve.

2. Required Equipment
Equipment Description Quantity Settings
1 Multimeter 1 Measure voltage
2 Decade resistor box 1 8 ohms
3
Table 1: Required equipment and its settings.

3. Test Procedure
Step 1: Set the decade box as close as possible to 8 ohms

Step 2: Connect the decade resistor box across the battery terminals.

Step 3: Measure the voltages across the terminals of the battery every 15 minutes when the
resistor box is connected. Record the value is MS Excel.

Step 4: When the battery terminal voltage drops below 5.8V disconnect the decade box and
battery.

4. Test Results
Step # Description Spec Measurement
1 Length of time for the battery
terminal voltage to drop 4 Hours Time (Minutes): 250 Minutes
below 5.8V
Table 2: The results of the test procedure.
P12441: Thermoelectric Stove for Haiti 2
Battery Discharge Test Procedure

Xiaolong (Battery B) Andrew (Battery A)


Time (min) Connected Voltage (V) Disconnected Voltage (V) Minutes Voltage (V)
0 6.23 6.5 0 6.492
15 6.23 6.38 15 6.376
30 6.22 6.34 30 6.360
45 6.19 6.32 45 6.330
60 6.17 6.27 60 6.300
75 6.14 6.25 75 6.290
90 6.11 6.21 90 6.255
105 6.08 6.18 105 6.235
120 6.05 6.16 120 6.200
135 6.01 6.13 135 6.178
150 5.97 6.09 150 6.145
165 5.93 6.06 180 6.070
180 5.88 6.02 195 6.032
195 5.83 5.97 210 6.012
210 5.75 5.92 225 5.900
225 5.66 5.86 240 5.800
240 5.46 5.73 255 5.000
255 5.11 5.41
Table 3: Terminal Voltage vs. Time

Battery Test
6.6

6.4

6.2

6
Voltage (V)

5.8

5.6
Battery B (Connected)
5.4
Battery B (Disconnected)
5.2
Battery A
5
0 50 100 150 200 250 300
Time (Minutes)

Figure 1: Battery Terminal voltage vs. Time


P12441: Thermoelectric Stove for Haiti 3
Battery Discharge Test Procedure

5. Pass/Fail
Did the unit pass or fail the test? Defend your decision.

PASS FAIL
Pass
Table 4: PASS/FAIL

You might also like