The
MCS-MAGNUM-N
MCS-MAGNUM-N
Specifications
Description & Specifications
& Description
Part # MCS-MAGNUM-N
Description Specifications
The MCS-MAGNUM is a durable microprocessor based Controller
controller designed for the hostile environments in the Dimensions............................. 12.0”w, 8.0”h, 2.0”d
HVAC/R industry. It is designed to be the primary manager of Mounting Holes Mounts on a backplane or in
the package it is controlling.
your enclosure
Operating Temperature...............-40°F to +158°F (-40°C to +70°C)
The Magnum provides flexibility with setpoints and control
options that can be selected prior to commissioning a system or Operating Humidity....................0-95% Non-Condensing
when the unit is live and functioning. Displays, alarms and other Storage Temperature............... -40°F to +158°F (-40°C to +70°C)
interfaces are accomplished in a clear and simple language that Microprocessor....................... Zilog eZ80 Acclaim! @ 50mhz
informs the user as to the status of the controller. Sensor Inputs (SI).................. 12 inputs 0-5vdc (10-bit A/D)
Digital Inputs........................... 4 inputs 0 or 5vdc only
The MCS-MAGNUM-OEM consists of a master micro Relay Outputs (RO)................ 10 outputs 6.3amps @ 230vac
controller along with a keypad and display. Complementing the Analog Outputs (AO).............. 4 outputs 0-10vdc
Magnum micro controller are the MCS-RO10 and MCS- Printed Circuit Board.............. Six layer with separate power
SI16-AO4 expansion boards. This allows for system expansion and ground planes
to a maximum of 112 inputs and 108 outputs. Communication Input Power (Standard).............115 or 230vac ±10% 50/60Hz @
with these units occurs at 38,400 baud over the MCS-I/O
77°F (25°C) ambient, 20VA max
port, which is dedicated to this purpose.
(Voltage is field selectable)
A RS-485 port is also provided for communication with other MCS-I/O Comm Port.............. 1 @ 38,400 baud
manufacturers systems. Other new features include the RS-485 Comm Port................ 1 @ 19,200 baud
integration of BACnet IP, Modbus IP and Modbus RTU into Ethernet.................................. 10/100 Mbps Ethernet
the Magnum. A MCS-BMS-GATEWAY is also available that Real Time Clock..................... Battery backup
allows communication via BACnet MSTP and LonWorks, or Power Detection..................... Automatic power fail reset
the data format is available to allow the user to communicate
directly.
Options
-MCS-MAG MOUNT KIT - consists of 8 - #6 Sheet Metal
A complete software support package is available for your Screws, 5 - Standoffs for Lexan
PC, allowing for system configuration, dynamic on-line Cover and 1 Lexan cover
display screens, remote communication, graphing and more. -24 24vac input power ±10%
Optional mounting kit available, see under options. 50/60Hz @ 77°F (25°C) ambient
Revision - 2018-05-22
5580 Enterprise
5580 Enterprise Pkwy.,
Pkwy., Fort
Fort Myers,
Myers, FLFL 33905
33905
For complete
For complete temperature
temperature chart,
chart, refer
refer to
to the
the MCS-T100
MCS-T100 spec
spec sheet
sheet
Office: 239-694-0089 • Fax: 239-694-0031 www.mcscontrols.com