0% found this document useful (0 votes)
127 views

TGS 2610-C00 - : For The Detection of LP Gas

This document provides product information for the TGS2610-C00 sensor for detecting LP gas. It details the sensor's features, applications, sensitivity characteristics, gas response pattern, basic measuring circuit, specifications, structure and dimensions.

Uploaded by

Pablo Estevez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
127 views

TGS 2610-C00 - : For The Detection of LP Gas

This document provides product information for the TGS2610-C00 sensor for detecting LP gas. It details the sensor's features, applications, sensitivity characteristics, gas response pattern, basic measuring circuit, specifications, structure and dimensions.

Uploaded by

Pablo Estevez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PRODUCT INFORMATION

TGS 2610-C00 - for the detection of LP Gas


Features: Applications:
* Quick response * Portable LP gas detectors
* Low power consumption * LP gas and vapor detection
* Long life and low cost
* Uses simple electrical circuit

TGS2610-C00 is a semiconductor type gas sensor which combines very


high sensitivity to LP gas with low power consumption and long life. Due to
miniaturization of its sensing chip, TGS2610-C00 requires a heater current of
only 56mA and the device is housed in a standard TO-5 package.
TGS2610-C00 possesses small size and quick gas response, making it suitable
for gas leakage checkers.
The TGS2610-C00 is able to satisfy the requirements of performance standards
such as UL1484 and EN50194.

The figure below represents typical sensitivity characteristics, The figure below represents the typical response pattern when
all data having been gathered at standard test conditions (see the sensor is inserted into and later removed from 1800ppm
reverse side of this sheet). The Y-axis is indicated as sensor of iso-butane.
resistance ratio (Rs/Ro) which is defined as follows:
Rs = Sensor resistance at various concentrations
Ro = Sensor resistance in 1800ppm of iso-butane
Sensitivity Characteristics: Gas Response to Iso-butane:
100 100

Air
10 10
Rs (kΩ)

Rs/Ro air 1800ppm air


iso-butane
Ethanol
1 Hydrogen 1
Methane 0 2 4 6 8 10
Iso-butane Time (min.)
Propane

0.1
100 1000 10000 100000
Gas concentration (ppm)
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY
RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET
GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS
NOT BEEN SPECIFICALLY TESTED BY FIGARO.
Basic Measuring Circuit:
The sensor requires two voltage inputs: A common power supply circuit can
heater voltage (VH) and circuit voltage be used for both VC and VH to fulfill the
(VC). The heater voltage (VH) is applied sensor's electrical requirements. The
to the integrated heater in order to value of the load resistor (RL) should be
maintain the sensing element at a specific chosen to optimize the alarm threshold
temperature which is optimal for sensing. value, keeping power dissipation (PS)
Circuit voltage (VC) is applied to allow of the semiconductor below a limit of
measurement of voltage (VOUT) across 15mW. Power dissipation (PS) will be
a load resistor (RL) which is connected highest when the value of Rs is equal
in series with the sensor. to RL on exposure to gas.

Specifications: Structure and Dimensions:


Model number TGS2610-C00

Sensing principle MOS type

Standard package TO-5 metal can


Top view
Target gases Butane, LP gas

Typical detection range 1~25% LEL


ø9.2±0.2 ø9.2±0.2
Heater voltage VH 5.0±0.2V AC/DC ø8.1±0.2
ø8.1±0.2
Standard circuit Sensing
Circuit voltage VC 5.0±0.2V DC Ps≤15mW
conditions element
Load resistance RL variable 0.45kΩ min.

Heater resistance RH approx 59Ω at room temp.


7.8±0.5
Heater current IH 56±5mA Side view

Electrical Heater power


PH 280mW VH=5.0V DC
characteristics consumption
under standard test 10.0±1.0 1
conditions 1.0~10.0kΩ
Sensor resistance RS
in 1800ppm iso-butane

Sensitivity 0.45~0.62 Rs (3000ppm) ø0.55±0.05 ø0.55±0.05


(change ratio of Rs) in iso-butane Rs (1000ppm)

iso-butane in air
Test gas conditions
at 20±2˚C, 65±5%RH 3.6±0.1 3.6±0.

Standard test Vc = 5.0±0.01V DC Bottom view


Circuit conditions
conditions VH = 5.0±0.05V DC
4 1 4 1
Conditioning period 90˚ 3.6±0.1 90˚
7 days 3 2 3 2
before test ø5.1

u/m:mm

Pin connection:
1: Heater
The value of power dissipation (PS) can Sensor resistance (Rs) is calculated with 2: Sensor electrode (-)
be calculated by utilizing the following a measured value of VOUT(VRL) by using 3: Sensor electrode (+)
formula: the following formula: 4: Heater

PS = (VC - VRL)2 RS = ( VC - 1) x RL
RS VRL FIGARO USA, INC.
121 S. Wilke Rd. Suite 300
For information on warranty, please refer to Standard Terms and Conditions of Sale of Arlington Heights, Illinois 60005
Figaro USA Inc. All sensor characteristics shown in this brochure represent typical Phone: (847)-832-1701
characteristics. Actual characteristics vary from sensor to sensor. The only characteristics Fax: (847)-832-1705
warranted are those in the Specification table above. email: [email protected]

REV: 12/17