Parameter Deviation Causes Consequences Action

The reactor outlet temperature was high, potentially damaging equipment, due to increased temperatures in incoming streams or decreased cooling. Actions taken included adjusting heat exchangers and compressor power. The distillation column reflux flow was low, risking dry out and reduced product quality, potentially due to pipe blockages, leaks, or pump failures. Actions included bypassing and adjusting heat exchangers. High reflux flow could flood the column and impact quality, possibly due to fully open valves or increased pumping. Actions included installing alarms and bypassing streams to control flows.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
116 views4 pages

Parameter Deviation Causes Consequences Action

The reactor outlet temperature was high, potentially damaging equipment, due to increased temperatures in incoming streams or decreased cooling. Actions taken included adjusting heat exchangers and compressor power. The distillation column reflux flow was low, risking dry out and reduced product quality, potentially due to pipe blockages, leaks, or pump failures. Actions included bypassing and adjusting heat exchangers. High reflux flow could flood the column and impact quality, possibly due to fully open valves or increased pumping. Actions included installing alarms and bypassing streams to control flows.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Reactor R-801, Reactor Outlet (Stream 9)

Parameter Deviation Causes Consequences Action

Temperature High 1) Air (Stream 1) temperature 1) Damage to Tubes in R-801/E- 1) Sensors and Alarms
2) Methanol (Stream 2) temperature 801/E-802 2) Control Heat Duty in E-801/E-
3) Recycle Methanol (Stream 14) 2) Damage to Catalysts in R-801 802 by valves on mps and hps
temperature 3) Damage to pipe stream respectively.
4) Temperature/Flow rate of mps in E- 4) Altered Conversion 3) Change power input to
801 5) Pressure Build up in R-801 Compressor
5) Temperature/Flow rate of hps in E- 6) Cavitation in P-801 A/B 4) Install redundancies
802 7) Shivering in E-801/E-802
6) Decrease in pumping power of P-801 8) Damage to Impellers in C-801
7) Valve on bfw and mps outlet fail
closed

Low 1) Air (Stream 1) temperature 1) Product quality will reduce 1) Sensors and Alarm on streams 6
2) Methanol (Stream 2) temperature 2) Increase in shell side level may and 7
3) Recycle Methanol (Stream 11) lead to leakage into tubes 2) Control Heat Duty of Exchangers
temperature by their respective utility stream
4) Temperature/Flow rate of mps/hps in 3) Change power input to
E-801/E-802 compressor
Distillation Column T-801, Reflux
Parameter Deviation Causes Consequences Action
Flow Low 1) Pipe Blockage 1) Column Dry Out 1) Bypass
2) Leakage 2) Change in Product Quality 2) Pressure Sensor and Low Pressure Alarm
3) Pump Failure 3) Damage to pipe following P-802 A/B
4) Decreased Efficiency of 4) Toxic 3) Temperature Sensor on cw outlet
E-805 5) Increase in pressure in reflux 4) Control Heat Duty by valve on cw inlet
-High Overhead Vapour drum and column
Rate
-Low flow rate of cw or
higher
5) Temperature of cw
6) Faulty LIC of V-801
7) Faulty FIC following P-
802A/B
High 1) Valve fully open 1) Flooding 1) High Level Alarm at Bottom
2) Increased Pumping 2) Change in Product Quality 2) Bypass on stream 14 with independent
Capacity 3) Rise in Bottom flow measuring element on Reflux line and
3) Faulty LIC of V-801 4) Leakage control flow of methanol to maintain stream
4) Faulty FIC following P- 3 amount
802 A/B