NEMA Configuration Chart Locking Devices: Indicates Page Number Where Devices Are Located. NEMA Number

This document provides a chart that lists National Electrical Manufacturers Association (NEMA) configurations for locking devices used in electrical systems. The chart specifies receptacle and plug design types for various voltages and currents ranging from 15 to 30 amps for 1-pole to 4-pole wiring systems. Device types include straight blade, twist-lock, and isolated ground receptacles and their corresponding plugs.

Uploaded by

Lily Parada
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
272 views

NEMA Configuration Chart Locking Devices: Indicates Page Number Where Devices Are Located. NEMA Number

This document provides a chart that lists National Electrical Manufacturers Association (NEMA) configurations for locking devices used in electrical systems. The chart specifies receptacle and plug design types for various voltages and currents ranging from 15 to 30 amps for 1-pole to 4-pole wiring systems. Device types include straight blade, twist-lock, and isolated ground receptacles and their corresponding plugs.

Uploaded by

Lily Parada
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NEMA Configuration Chart

Locking Devices
15 AMPERE 20 AMPERE 30 AMPERE
RECEPTA CLE PLUG RECEPTA CLE PLUG RECEPTA CLE PLUG
H-4➀ H-4
125V ML1
2-POLE 2-WIRE

ML-1R ML-1P
H-5 H-5
125V L1
L1-15R➁ L1-15P
H-6 H-6
250V L2
L2-20R L2-20P
H-7 H-7
125V ML2
ML-2R ML-2P
H-8,H-9 H-8,H-9 H-12 H-12 H-16 H-16
125V L5
L5-15R L5-15P L5-20R L5-20P L5-30R L5-30P
H-10 H-10 H-12 H-12 H-16 H-16
2-POLE 3-WIRE GROUNDING

250V L6
L6-15R L6-15P L6-20R L6-20P L6-30R L6-30P
H-11 H-11 H-12 H-12 H-16 H-16
277V A C L7
L7-15R L7-15P L7-20R L7-20P L7-30R L7-30P
H-13 H-13 H-17 H-17
480V A C L8
L8-20R L8-20P L8-30R L8-30P
H-13 H-13 H-17 H-17
600V A C L9
L9-20R L9-20P L9-30R L9-30P
H-15 H-15
28V DC FSL1
FSL1 FSL1
H-15 H-15
400Hz 120V FSL2
FSL2 FSL2
H-22 H-22
125/250V ML3
ML-3R ML-3P
H-25 H-25 H-27 H-27
3-POLE 3-WIRE

125/250V L10
L10-20R L10-20P L10-30R L10-30P
H-25 H-25 H-27 H-27
3Ø 250V L11
L11-15R L11-15P L11-20R L11-20P L11-30R L11-30P
H-25 H-25 H-28 H-28
3Ø 480V L12
L12-20R L12-20P L12-30R L12-30P
H-28 H-28
3Ø 600V L13
L13-30R L13-30P
H-30 H-30 H-31 H-31
125/250V L14
3-POLE 4-WIRE GROUNDING

L14-20R L14-20P L14-30R L14-30P


H-30 H-30 H-31 H-31
3Ø 250V L15
L15-20R L15-20P L15-30R L15-30P
H-30 H-30 H-32 H-32
3Ø 480V L16
L16-20R L16-20P L16-30R L16-30P
H-32 H-32
3Ø 600V L17
L17-30R L17-30P
400Hz 3Ø ∆ H-29 H-29
FSL3
120V
FSL3 FSL3
3ØY H-39 H-39 H-41 H-41
4-POLE 4-WIRE

120/208V L18
L18-20R L18-20P L18-30R L18-30P
3ØY H-39 H-39 H-41 H-41
277/480V L19
L19-20R L19-20P L19-30R L19-30P
3ØY H-39 H-39 H-41 H-41
347/600V L20
L20-20R L20-20P L20-30R L20-30P
3ØY H-43 H-43 H-46 H-46
4-POLE 5-WIRE GROUNDING

120/208V L21
L21-20R L21-20P L21-30R L21-30P
3ØY H-43 H-43 H-46 H-46
277/480V L22
L22-20R L22-20P L22-30R L22-30P
3ØY H-43 H-43 H-46 H-46
347/600V L23
L23-20R L23-20P L23-30R L23-30P
400Hz 3ØY H-45 H-45
120/208V FSL4
FSL4 FSL4

H c Indicates page number where devices are located.


d NEMA Number
Specifications are subject to change without notice.